Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configuration planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Tensor-to-scalar ratio forecasts for extended LiteBIRD frequency configurations

LiteBIRD is a planned JAXA-led cosmic microwave background (CMB) B-mode satellite experiment aiming for launch in the late 2020s, with a primary goal of detecting the imprint of primordial inflationary gravitational waves. Its current baseline focal-plane configuration includes 15 frequency bands between 40 and 402 GHz, fulfilling the mission requirements to detect the amplitude of gravitational waves with the total uncertainty on the tensor-to-scalar ratio, δr, down to δr < 0.001. A key aspect of this performance is accurate astrophysical component separation, and the ability to remove polarized thermal dust emission is particularly important. In this paper we note that the CMB frequency spectrum falls off nearly exponentially above 300 GHz relative to the thermal dust spectral energy distribution, and a relatively minor high frequency extension can therefore result in even lower uncertainties and better model reconstructions. Specifically, we compared the baseline design with five extended configurations, while varying the underlying dust modeling, in each of which the High-Frequency Telescope (HFT) frequency range was shifted logarithmically toward higher frequencies, with an upper cutoff ranging between 400 and 600 GHz. In each case, we measured the tensor-to-scalar ratio r uncertainty and bias using both parametric and minimum-variance component-separation algorithms. When the thermal dust sky model includes a spatially varying spectral index and temperature, we find that the statistical uncertainty on r after foreground cleaning may be reduced by as much as 30–50% by extending the upper limit of the frequency range from 400 to 600 GHz, with most of the improvement already gained at 500 GHz. We also note that a broader frequency range leads to higher residuals when fitting an incorrect dust model, but also it is easier to discriminate between models through higher χ 2 sensitivity. Even in the case in which the fitting procedure does not correspond to the underlying dust model in the sky, and when the highest frequency data cannot be modeled with sufficient fidelity and must be excluded from the analysis, the uncertainty on r increases by only about 5% for a 500 GHz configuration compared to the baseline.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Planning Quality and Efficiency Between Conventional and Knowledge-based Algorithms in Nasopharyngeal Cancer Patients Using Intensity Modulated Radiation Therapy

Purpose: Intensity modulated radiation therapy (IMRT) is widely used to achieve a highly conformal dose and improve treatment outcome. However, plan quality and planning time are institute and planner dependent, and no standardized tool exists to recognize an optimal plan. RapidPlan, a knowledge-based algorithm, can generate constraints to assist optimization and produce high-quality IMRT plans. This report evaluated the quality and efficiency of using RapidPlan in nasopharyngeal carcinoma (NPC) IMRT planning. Methods and Materials: RapidPlan was configured using 79 radical IMRT plans for NPC; 20 consecutive NPC patients indicated for radical radiation therapy between October 2014 and May 2015 were then recruited to assess its performance. The ability of RapidPlan to produce acceptable plans was evaluated. For plans that could not achieve clinical acceptance, manual touch-up was performed. The IMRT plans produced without RapidPlan (manual plans) and with RapidPlan (RP-2 plans, including those with manual touch-up) were compared in terms of dosimetric quality and planning efficiency. Results: RapidPlan by itself could produce clinically acceptable plans for 9 of the 20 patients; manual touch-up increased the number of acceptable plans (RP-2 plans) to 19. The target dose coverage and conformity were very similar. No difference was found in the maximum dose to the brainstem and optic chiasm. RP-2 plans delivered a higher maximum dose to the spinal cord (46.4 Gy vs 43.9 Gy, P=.002) but a lower dose to the parotid (mean dose to right parotid, 37.3 Gy vs 45.4 Gy; left, 34.4 Gy vs 43.1 Gy; P<.001) and the right cochlea (mean dose, 48.6 Gy vs 52.6 Gy; P=.02). The total planning time for RP-2 plans was significantly less than that for manual plans (64 minutes vs 295 minutes, P<.001). Conclusions: This study shows that RapidPlan can significantly improve planning efficiency and produce quality IMRT plans for NPC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-55: Dosimetric Evaluation of Centrally Located Lung Tumors: A Monte Carlo (MC) Study of Lung SBRT Planning

Purpose: To compare dose distributions calculated using the iPlan XVMC algorithm and heterogeneities corrected/uncorrected Pencil Beam (PB-hete/PB-homo) algorithms for SBRT treatments of lung tumors. Methods: Ten patients with centrally located solitary lung tumors were treated using MC-based SBRT to 60Gy in 5 fractions for PTVV100%=95%. ITV was delineated on MIP-images based on 4D-CT scans. PTVs(ITV+5mm margins) ranged from 10.1–106.5cc(mean=48.6cc). MC-SBRT plans were generated with a combination of non-coplanar conformal arcs/beams using iPlan-XVMC-algorithm (BrainLABiPlan ver.4.1.2) for Novalis-TX consisting of HD-MLCs and 6MV-SRS(1000MU/min) mode, following RTOG 0813 dosimetric criteria. For comparison, PB-hete/PB-homo algorithms were used to re-calculate dose distributions using same beam configurations, MLCs/monitor units. Plans were evaluated with isocenter/maximal/mean doses to PTV. Normal lung doses were evaluated with V5/V10/V20 and mean-lung-dose(MLD), excluding PTV. Other OAR doses such as maximal spinal cord/2cc-esophagus/max bronchial tree (BT/maximal heart doses were tabulated. Results: Maximal/mean/isocenter doses to PTV calculated by PB-hete were uniformly larger than MC plans by a factors of 1.09/1.13/1.07, on average, whereas they were consistently lower by PB-homo by a factors of 0.9/0.84/0.9, respectively. The volume covered by 5Gy/10Gy/20Gy isodose-lines of the lung were comparable (average within±3%) when calculated by PB-hete compared to XVMC, but, consistently lower by PB-homo by a factors of 0.90/0.88/0.85, respectively. MLD was higher with PB-hete by 1.05, but, lower by PB-homo by 0.9, on average, compared to XVMC. XVMC max-cord/max-BT/max-heart and 2cc of esophagus doses were comparable to PB-hete; however, PB-homo underestimates by a factors of 0.82/0.89/0.88/0.86, on average, respectively. Conclusion: PB-hete significantly overestimates dose to PTV relative to XVMC -hence underdosing the target. MC is more complex and accurate with tissue-heterogeneities.The magnitude of variation significantly varies with ‘small-island-tumor’ surrounded by low-density lung tissues -PB algorithms lacks later electron scattering. Dose calculation with XVMC for lung SBRT is routinely performed in our clinic, its performance for head'neck/sinus cases will also be investigated.

60 APPLIED LIFE SCIENCES↗

Clinical Study of the Necessity of Replanning Before the 25th Fraction During the Course of Intensity-Modulated Radiotherapy for Patients With Nasopharyngeal Carcinoma

Purpose: To quantify the target and normal structures on dose distributing variations during intensity-modulated radiotherapy (IMRT) and to assess the value of replanning for nasopharyngeal carcinoma (NPC) patients. Methods and Materials: Twenty-eight NPC patients treated with IMRT were recruited. The IMRT was delivered in 33 fractions, to 70 to 76Gy, to the gross tumor volume (GTV). Before the 25th fraction of IMRT, a new simulation computed tomography (CT) scan was acquired for all patients. According to the dose constraint criterion in the Radiation Therapy Oncology Group (RTOG) 0225 protocol, the replanning was generated on the new simulation CT. With the Quality Assessment Center of a CORVUS 6.3 treatment planning system, a phantom plan was generated for each patient by applying the beam configurations of the initial plan to the anatomy of the new simulation CT. The dose-volume histograms of the phantom plan were compared with the replanning. Results: The percentage of prescription dose delivered to the clinical target volume (CTV1) was significantly increased by 4.91% +- 10.89%, whereas the maximum dose to the spinal cord, mean dose to the left parotid, and V30 to the right parotid were significantly decreased by 5.00 +- 9.23Gy, 4.23 +- 10.03Gy, and 11.47% +- 18.89% respectively in the replanning, compared with the phantom plan (p < 0.05). Based on the dose constraint criterion in the RTOG0225 protocol, 50% of phantom plans (14/28) were out of limit for the dose to the normal critical structures, whereas no plan was out of limit in replanning (p < 0.001). Conclusion: Replanning for patients with NPC before the 25th fraction during IMRT helps to ensure adequate dose to the target volumes and safe doses to critical normal structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Considerations for Managing DOE Standard Canisters within an Over-canister as Part of an Integrated Waste Management System PPT

To better enable informed decision making regarding the back-end of the nuclear fuel cycle, the Integrated Waste Management Program within the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) has been sponsoring research into a comprehensive integrated waste management system (IWMS) that considers all major back-end aspects of the nuclear fuel cycle (i.e., transportation, storage, and disposal). An important aspect of the IWMS is DOE-managed Spent Nuclear Fuel (SNF). DOE and its predecessor agencies have generated, transported, received, stored, and reprocessed SNF at DOE facilities nationwide, and DOE is responsible for managing the SNF currently in its possession. These fuels come from a wide range of reactor types that employ various cladding materials, fuel materials, and enrichments. To enable interim, road-ready dry storage (RRDS) of the wide variety of SNF types found in the DOE inventory, a standardized canister system (i.e., the DOE Standard Canister) was proposed for the packaging demonstration. This robust, welded canister system is designed to confine radionuclides, prevent criticality by precluding content moderation, and satisfy other requirements as part of a larger storage, transportation, and disposal system. While SNF has yet to be loaded into a DOE Standard Canister, DOE Standard Canister designs were included in past storage facility and disposal facility design licensing endeavors. In a renewed effort to evaluate packaging SNF at Idaho National Laboratory (INL) in a RRDS configuration, researchers are planning the RRDS Packaging Demonstration. This demonstration is supplemented by analytical structural, criticality, and material compatibility evaluations that support management of SNF in DOE Standard Canisters, taking advantage of past analysis work to the extent possible. One of the largest differences between the current Packaging Demonstration and past analytical evaluations is the inclusion of an over-canister containing multiple DOE Standard Canisters. For the Packaging Demonstration, DOE Standard Canisters loaded with SNF are planned to be placed in a larger diameter over-canister. The sealed over-canister could then be placed in a storage overpack for onsite storage, or in a transportation overpack for shipment to an offsite storage location or disposal site once one becomes available. This paper examines the relevant considerations and provides a preliminary evaluation of integrating the over-canister configuration into the storage, transportation, and disposal processes of the overall waste management system. For storage and transportation, the over-canister can be considered analogous to a multi-purpose canister (MPC) for commercial SNF. For disposal, the DOE Standard Canisters could be removed from the over-canister and placed in a co-disposal waste package with canisters containing vitrified high-level radioactive waste (HLW) similar to configurations examined previously, or the sealed over-canisters might be capable of direct disposal in a waste package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Considerations for Managing DOE Standard Canisters within an Over-canister as Part of an Integrated Waste Management System

To better enable informed decision making regarding the back end of the nuclear fuel cycle, the Integrated Waste Management Program within the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) has been sponsoring the research into a comprehensive integrated waste management system (IWMS) that considers all major back-end aspects of the nuclear fuel cycle (i.e., transportation, storage, and disposal). An important aspect of the IWMS is DOE-managed SNF. DOE and its predecessor agencies have generated, transported, received, stored, and reprocessed SNF at DOE facilities nationwide, and DOE is responsible for managing the SNF currently in its possession. These fuels come from a wide range of reactor types that employ various cladding materials, fuel materials, and enrichments. To enable interim, road-ready dry storage (RRDS) of the wide variety of SNF types found in the DOE inventory, a standardized canister system (i.e., the DOE Standard Canister) was proposed. This robust, welded canister system is designed to confine radionuclides, prevent criticality by precluding content moderation, and satisfy other requirements as part of a larger storage, transportation, and disposal system. While SNF has yet to be loaded into a DOE Standard Canister, DOE Standard Canister designs were included in past storage facility and disposal facility design licensing endeavors. In a renewed effort to evaluate packaging SNF at Idaho National Laboratory (INL) in a RRDS configuration, researchers are planning the RRDS Packaging Demonstration. This demonstration is supplemented by analytical structural, criticality, and material compatibility evaluations that support management of SNF in DOE Standard Canisters, taking advantage of past analysis work to the extent possible. One of the largest differences between the current Packaging Demonstration and past analytical evaluations is the inclusion of an over-canister containing multiple DOE Standard Canisters. For the Packaging Demonstration, DOE Standard Canisters loaded with SNF are planned to be placed in a larger diameter over-canister. The sealed over-canister could then be placed in a storage overpack for onsite storage, or in a transportation overpack for shipment to an offsite storage location or disposal site once one becomes available. This paper examines the relevant considerations and provides a preliminary evaluation of integrating the over-canister configuration into the storage, transportation, and disposal processes of the overall waste management system. For storage and transportation, the over-canister can be considered analogous to a multi-purpose canister (MPC) for commercial SNF. For disposal, the DOE Standard Canisters could be removed from the over-canister and placed in a co-disposal waste package with canisters containing vitrified HLW similar to configurations examined previously, or the sealed over-canisters might be capable of direct disposal in a waste package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

National Plan for the Disposal of Existing and Future TRU Wastes - 18616

Now that the Waste Isolation Pilot Plant (WIPP) has re-opened, after being down for three years due to an accident the DOE National TRU Program has re-developed a plan for the disposal of existing and future TRU wastes. The National TRU Waste Management Plan (NTWMP) is an integrated plan to address the needs of DOE sites across the DOE Weapons Complex that create and store TRU waste, and is centered on the capability of WIPP to receive and dispose of TRU waste. The WIPP capability is planned as a weekly shipping rate and is defined by emplacement and receipt rate capabilities since WIPP is not permitted for long-term storage. And, shipping rates may be constrained by new WIPP Waste Acceptance Criteria (WAC) and future plans for repository configurations and disposal package capabilities over the next 30 years. Since WIPP is the only disposal system available to the DOE for TRU waste disposal, DOE has a newly projected life-cycle need for WIPP to remain open and available up to 2050. It is projected that the need for WIPP will continue up to the year 2050 for the disposition of the remaining legacy TRU inventories and for the disposal of TRU waste continuing to be generated at DOE's National Laboratories. In addition, there are several other potential new waste streams in which WIPP is being considered an alternative solution for their disposition. The NTWMP has been updated to reflect the short-term and long-term plans for TRU waste disposal at WIPP. The short-term plan is used by DOE for budget projection and integration purposes to facilitate and inform budget planning, both in DOE's Environmental Management (EM) and National Nuclear Security Administration (NNSA) organizations. Most legacy TRU waste (generated in the past and stored at DOE sites today) is owned and managed by EM. And, EM submits integrated budget requests for DOE sites, including the integration of resources for TRU waste management. NNSA and DOE's Office of Science (OS) funds TRU waste management as part of their mission funding and NNSA should eventually be the primary user of the WIPP resources as EM's legacy TRU waste is cleaned-up. Prior to the unexpected shutdown of WIPP in 2014, there was a small back-log of waste certified for WIPP disposal and shipments of TRU waste to WIPP were 'just-in-time' as waste was certified. After three years of WIPP being down, DOE sites have built significant back-logs of TRU waste to be certified for WIPP. That back-log built up to over 25,000 containers of TRU waste during that three-year period (Table 1). The backlog included both Contact-Handled (CH) TRU waste and Remote-Handled (RH) TRU waste, and even though WIPP re-opened in April of 2017, it is only open for TRU waste containers that can be stacked on disposal room floors. Plans for changing RH waste disposal packages and methods are in-the-works, but are not yet mature enough for significant planning. In addition, the WIPP underground facilities are now partially contaminated with radioactive particulate, which significantly reduces the WIPP operational efficiencies as compared to 2014. With a large back-log of waste ready for WIPP disposal and limited throughput for WIPP disposal rates, the focus of the NTWMP is to prioritize the selection of TRU wastes from the various sites based on WIPP waste emplacement rates and shipping rates to WIPP. Some TRU waste sites have a significant need to be top priority for shipments to WIPP, and that must be balanced with the need for all TRU waste sites to have some shipments to deplete their back-log of TRU wastes. Storage and management of TRU waste is very costly for DOE and many of those resources could be used to optimize the overall disposition of TRU waste and save DOE significant funding. In addition, the plan will show the possible transition of TRU Waste Management from primarily being an EM function to being an NNSA function in the coming years. As legacy TRU waste inventories are removed, and as NNSA mission-related TRU waste inventories are produced, DOE will be faced with deciding where the primary responsibility for TRU waste management should reside. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-337: Treatment Planning Study of Craniospinal Irradiation with Spot Scanning Proton Therapy

Purpose: To develop a treatment planning technique that achieves optimal robustness against systematic position and range uncertainties, and interfield position errors for craniospinal irradiation (CSI) using spot scanning proton radiotherapy. Methods: Eighteen CSI patients who had previously been treated using photon radiation were used for this study. Eight patients were less than 10 years old. The prescription dose was 23.4Gy in 1.8Gy fractions. Two different field arrangement types were investigated: 1 posterior field per isocenter and 2 posterior oblique fields per isocenter. For each field type, two delivery configurations were used: 5cm bolus attached to the treatment table and a 4.5cm range shifter located inside the nozzle. The target for each plan was the whole brain and thecal sac. For children under the age of 10, all plan types were repeated with an additional dose of 21Gy prescribed to the vertebral bodies. Treatment fields were matched by stepping down the dose in 10% increments over 9cm. Robustness against 3% and 3mm uncertainties, as well as a 3mm inter-field error was analyzed. Dose coverage of the target and critical structure sparing for each plan type will be considered. Ease of planning and treatment delivery was also considered for each plan type. Results: The mean dose volume histograms show that the bolus plan with posterior beams gave the best overall plan, and all proton plans were comparable to or better than the photon plans. The plan type that was the most robust against the imposed uncertainties was also the bolus plan with posterior beams. This is also the plan configuration that is the easiest to deliver and plan. Conclusion: The bolus plan with posterior beams achieved optimal robustness against systematic position and range uncertainties, as well as inter-field position errors.

60 APPLIED LIFE SCIENCES↗

A multi-layer SEU mitigation strategy to improve FPGA design robustness for the ATLAS muon spectrometer upgrade

We present a multi-layer single-event upset mitigation strategy implemented in a low-cost Xilinx Artix-7 FPGA. The implementation is targeted for a trigger data router for the ATLAS muon spectrometer upgrade. The mitigation strategy employs three layers of protection to improve overall FPGA design robustness: use of triple-modular redundancy for FPGA fabric logic and embedded soft-error mitigation in the first layer; further enhancement with multi-boot FPGA reconfiguration across multiple copies of configuration memory in the second layer; and FPGA power cycling and configuration memory re-initialization in the third layer. Here, the effectiveness of this scheme has been evaluated at two different neutron facilities, LANSCE and NCSR ‘‘Demokritos’’, with 800 MeV and 25 MeV beam energies, respectively. Testing was performed with a similar configuration to that planned for final operation. We discuss the testing strategy and summarize the test results to estimate the expected data loss over 10 years of operation in the ATLAS experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac

Purpose: Linac-magnetic resonance (MR) systems have been proposed in order to achieve real-time image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to achieve better quality images while reducing hot and cold spots in treatment planning. An investigation of linac's performance in the longitudinal fringe magnetic fields of the MR imager is given. Methods: The open MR imager fringe magnetic field was modeled using the analytic solution of the magnetic field generated from current carrying loops. The derived solution was matched to the magnetic fringe field isolines provided for a 0.5 T open MR imager through Monte Carlo optimization. The optimized field solution was then added to the previously validated 6 MV linac simulation to quantify linac's performance in the fringe magnetic field of a 0.5 T MR imager. To further the investigation, linac's performance in large fringe fields expected from other imagers was investigated through the addition of homogeneous longitudinal fields. Results: The Monte Carlo optimization of the analytic current loop solution provided good agreement with the magnetic fringe field isolines supplied by the manufacturer. The range of magnetic fields the linac is expected to experience when coupled to the 0.5 T MR imager was determined to be from 0.0022 to 0.011 T (as calculated at the electron gun cathode). The effect of the longitudinal magnetic field on the electron beam was observed to be only in the electron gun. The longitudinal field changed the electron gun optics, affecting beam characteristics, such as a slight increase in the injection current and beam diameter, and an increasingly nonlaminar transverse phase space. Although the target phase space showed little change in its energy spectrum from the altered injection phase space, a reduction in the target current and spatial distribution peak intensity was observed. Despite these changes, the target phase space had little effect on the depth dose curves or dose profiles calculated for a 40x40 cm{sup 2} field at 1.5 cm depth. At longitudinal fields larger than 0.012 T, a drastic reduction in the injection current from the electron gun was observed due to a large fraction of electrons striking the anode. This further reduced the target current, which reached a minimum of 28{+-}2 mA at 0.06 T. A slow increase in the injection and target currents was observed at fields larger than 0.06 T due to greater beam collimation in the anode beam tube. Conclusions: In an effort to achieve higher quality images and a reduction in hot and cold spots in the treatment plan, a parallel configuration linac-MR system is presented. The longitudinal magnetic fields of the MR imager caused large beam losses within the electron gun. These losses may be eliminated through a redesign of the electron gun optics incorporating a longitudinal magnetic field, or through magnetic shielding, which has already been proven successful for the transverse configuration.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-511: Feasibility Study of Using Flattening-Filter-Free Photon Beams to Deliver Conventional Flat Beam

Purpose: Various dosimetric benefits such as increased dose rate, and reduced leakage and out of field dose has led to the growth of FFF technology in the clinic. In this study, we concentrate on investigating the feasibility of using flattening-filter-free (FFF) beams to deliver conventional flat beams (CFB), since completely getting rid of the flattening-filter module from the gantry head can not only simplify the gantry design but also decrease the workload on machine maintain and quality assurance. Methods: The sliding window based IMRT technique was utilized to generate the CFB from the FFF beam for various beam configurations on the Elekta Versa HD. The flat beam reproducibility and MU efficiency were compared for each beam configuration among FFF planning, delivery and CFB planning. Results: Compared to the CFB plan, the 3%3mm passing rates of the FFF beams from both measurement and plan are 100% and 95%(or better) for 15×15 cm{sup 2} or smaller field size and for any field size greater than 15×15 cm{sup 2}at 10 cm depth, respectively. The largest discrepancy is about 5% and typically appears at the field shoulder area. The MU increase average was 80% for FFF compared to CFB, however has a minimal impact on treatment delivery time. Conclusion: The ability to deliver conventional flat treatments is not absent when operating in FFF mode. With proper TPS manipulation and beam modulation, FFF mode can achieve reasonable flat profiles and comparable dose coverage as CFB does for various conventional treatment techniques, such as four field box, or long spine treatment techniques. The ability to deliver most clinical treatments from the same treatment unit, will allow for less quality assurance as well as maintenance, and completely eliminate the need for the flattening filter on modern linacs.

60 APPLIED LIFE SCIENCES↗

CMB-S4 Decadal Survey APC White Paper

We provide an overview of the science case, instrument configuration and project plan for the next-generation ground-based cosmic microwave background experiment CMB-S4, for consideration by the 2020 Decadal Survey.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optical Stochastic Cooling Program at Fermilab's Integrable Optics Test Accelerator

Beam cooling enables an increase of peak and average luminosities and significantly expands the discovery potential of colliders. Optical Stochastic Cooling (OSC) is a high-bandwidth cooling technique that will advance the present state-of-the-art, stochastic-cooling rate by more than three orders of magnitude. A proof-of-principle demonstration with protons or heavy ions involves prohibitive costs, risks and technological challenges; however, exploration of OSC with electrons is a cost-effective alternative for studying the beam-cooling physics, optical systems and diagnostics. The ability to demonstrate OSC was a key requirement in the design of Fermilab's Integrable Optics Test Accelerator (IOTA) ring. The IOTA program will explore the physics and technology of OSC in amplified and non-amplified configurations. We also plan to investigate the cooling and manipulation of a single electron stored in the ring. The OSC apparatus is currently being fabricated, and installation will begin in the fall of 2019. In this contribution, we will describe the IOTA OSC program, the upcoming passive-OSC experimental runs and ongoing preparations for an amplified-OSC experiment

43 PARTICLE ACCELERATORS↗

Optical Stochastic Cooling Program at Fermilab's Integrable Optics Test Accelerator

Beam cooling enables an increase of peak and average luminosities and significantly expands the discovery potential of colliders. Optical Stochastic Cooling (OSC) is a high-bandwidth cooling technique that will advance the present state-of-the-art, stochastic-cooling rate by more than three orders of magnitude. A proof-of-principle demonstration with protons or heavy ions involves prohibitive costs, risks and technological challenges; however, exploration of OSC with electrons is a cost-effective alternative for studying the beam-cooling physics, optical systems and diagnostics. The ability to demonstrate OSC was a key requirement in the design of Fermilab's Integrable Optics Test Accelerator (IOTA) ring. The IOTA program will explore the physics and technology of OSC in amplified and non-amplified configurations. We also plan to investigate the cooling and manipulation of a single electron stored in the ring. The OSC apparatus is currently being fabricated, and installation will begin in the fall of 2019. In this contribution, we will describe the IOTA OSC program, the upcoming passive-OSC experimental runs and ongoing preparations for an amplified-OSC experiment.

43 PARTICLE ACCELERATORS↗

Figure-of-Merit for a Cold Coupled Moderator at the SNS Second Target Station suited for Direct Geometry Inelastic Spectrometers

The suite of moderators for the Second Target Station (STS) at the Spallation Neutron Source (SNS) in Oak Ridge is currently undergoing the planning stage at which various options and configurations are being considered. The current plans for the instrument suite include two direct geometry inelastic spectrometers, CHESS and HERTZ, which will receive beam from cold moderators and work mostly in the 1-20 meV incident energy range. CHESS will be a relatively short (wide bandwidth) instrument that is dedicated to studying small samples (∼mm3) with coarse energy resolution (2.5 – 5% of Ei). HERTZ on the other hand will be designed to achieve very good energy resolution, 1 – 3% of Ei, using a long secondary flightpath with a ∼ 4 × 4 cm2 beam on sample. In this contribution, we will discuss the implications of these design requirements for the optimal moderator pulse width, and for the repetition rate that would be best suited for the spectrometers.

Ehlers, Georg↗

Implementation of Fiducial-Based Image Registration in the Cyberknife Robotic System

Fiducial-based image registration methodology as implemented in the Cyberknife system is explored. The Cyberknife is a radiosurgery system that uses image guidance technology and computer-controlled robotics to determine target positions and adjust beam directions accordingly during the dose delivery. The image guidance system consists of 2 x-ray sources mounted on the ceiling and a detection system mounted on both sides of the treatment couch. Two orthogonal live radiographs are taken prior to and during patient treatment. Fiducial markers are identified on these radiographs and compared to a library of digital reconstructed radiographs (DRRs) using the fiducial extraction software. The fiducial extraction software initially sets an intensity threshold on the live radiographs to generate white areas on black images referred to as 'blobs.' Different threshold values are being used and blobs at the same location are assumed to originate from the same object. The number of blobs is then reduced by examining each blob against a predefined set of properties such as shape and exposure levels. The remaining blobs are further reduced by examining the location of the blobs in the inferior-superior patient axis. Those blobs that have the corresponding positions are assumed to originate from the same object. The remaining blobs are used to create fiducial configurations and are compared to the reference configuration from the computed tomography (CT) image dataset for treatment planning. The best-fit configuration is considered to have the appropriate fiducial markers. The patient position is determined based on these fiducial markers. During the treatment, the radiation beam is turned off when the Cyberknife changes nodes. This allows a time window to acquire live radiographs for the determination of the patient target position and to update the robotic manipulator to change beam orientations accordingly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗