Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Skeletal dosimetry in cone beam computed tomography

Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12x0.12x0.12 cm{sup 3}, with 17x17x17 {mu}m{sup 3} microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens ({approx}8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only {approx}50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners

Purpose: Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and models of multidetector row CT (MDCT) scanners. Methods: Physical measurements were collected using nine CT scanners (three scanners each of GE VCT, GE LightSpeed 16, and Siemens Sensation 64 CT). Measurements were made using various combinations of technical factors, including kVp, type of bowtie filter, and x-ray beam collimation, for several dosimetry-related quantities, including (a) free-in-air CT dose index (CTDI{sub 100,air}); (b) calculated half-value layers and quarter-value layers; and (c) weighted CT dose index (CTDI{sub w}) calculated from exposure measurements collected in both a 16 and 32 cm diameter CTDI phantom. Data collection was repeated at several different time intervals, ranging from seconds (for CTDI{sub 100,air} values) to weekly for 3 weeks and then quarterly or triannually for 1 yr. Precision of the data was quantified by the percent coefficient of variation (%CV). Results: The maximum relative precision error (maximum %CV value) across all dosimetry metrics, time periods, and scanners included in this study was 4.33%. The median observed %CV values for CTDI{sub 100,air} ranged from 0.05% to 0.19% over several seconds, 0.12%-0.52% over 1 week, and 0.58%-2.31% over 3-4 months. For CTDI{sub w} for a 16 and 32 cm CTDI phantom, respectively, the range of median %CVs was 0.38%-1.14% and 0.62%-1.23% in data gathered weekly for 3 weeks and 1.32%-2.79% and 0.84%-2.47% in data gathered quarterly or triannually for 1 yr. Conclusions: From a dosimetry perspective, the MDCT scanners tested in this study demonstrated a high degree of within-run, between-run, and between-scanner precision (with relative precision errors typically well under 5%).

60 APPLIED LIFE SCIENCES↗

A fully 3D approach for metal artifact reduction in computed tomography

Purpose: In computed tomography imaging metal objects in the region of interest introduce inconsistencies during data acquisition. Reconstructing these data leads to an image in spatial domain including star-shaped or stripe-like artifacts. In order to enhance the quality of the resulting image the influence of the metal objects can be reduced. Here, a metal artifact reduction (MAR) approach is proposed that is based on a recomputation of the inconsistent projection data using a fully three-dimensional Fourier-based interpolation. The success of the projection space restoration depends sensitively on a sensible continuation of neighboring structures into the recomputed area. Fortunately, structural information of the entire data is inherently included in the Fourier space of the data. This can be used for a reasonable recomputation of the inconsistent projection data. Methods: The key step of the proposed MAR strategy is the recomputation of the inconsistent projection data based on an interpolation using nonequispaced fast Fourier transforms (NFFT). The NFFT interpolation can be applied in arbitrary dimension. The approach overcomes the problem of adequate neighborhood definitions on irregular grids, since this is inherently given through the usage of higher dimensional Fourier transforms. Here, applications up to the third interpolation dimension are presented and validated. Furthermore, prior knowledge may be included by an appropriate damping of the transform during the interpolation step. This MAR method is applicable on each angular view of a detector row, on two-dimensional projection data as well as on three-dimensional projection data, e.g., a set of sequential acquisitions at different spatial positions, projection data of a spiral acquisition, or cone-beam projection data. Results: Results of the novel MAR scheme based on one-, two-, and three-dimensional NFFT interpolations are presented. All results are compared in projection data space and spatial domain with the well-known one-dimensional linear interpolation strategy. Conclusions: In conclusion, it is recommended to include as much spatial information into the recomputation step as possible. This is realized by increasing the dimension of the NFFT. The resulting image quality can be enhanced considerably.

60 APPLIED LIFE SCIENCES↗

Measuring Weld Profiles By Computer Tomography

Noncontacting, nondestructive computer tomography system determines internal and external contours of welded objects. System makes it unnecessary to take metallurgical sections (destructive technique) or to take silicone impressions of hidden surfaces (technique that contaminates) to inspect them. Measurements of contours via tomography performed 10 times as fast as measurements via impression molds, and tomography does not contaminate inspected parts.

Pascua, Antonio G.↗

Using Multiplicative Algebraic Reconstruction Techniques (MART) to Derive Instrument Requirements for Computed Tomography Imaging Spectrographs

Computed Tomography Imaging Spectrographs (CTISs), which are generally slitless or large-aperture spectrographs that observe a wide, dispersed field of view in multiple dispersion angles or diffraction orders, provide a unique opportunity to capture spectral information over an extended source, such as the Sun, but require software reconstruction techniques to be fully utilized. A useful data product that can be recovered from CTIS observations is intensity maps of solar features in single spectral lines. These intensity maps can then be used to determine temperature, density, abundance, and equilibrium properties of the emitting plasma. We apply the multiplicative algebraic reconstruction technique (MART) to example data from a variety of CTIS configurations to determine the capability and limitations of the method to return spectrally-pure maps. By completing this study, we aim to establish a path to derive requirements for CTIS instruments that rely on reconstruction techniques to meet their science objectives.

Amy Winebarger↗

Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

60 APPLIED LIFE SCIENCES↗

Surface Roughness Calculations of Additively Manufactured Cylinders via X-Ray Computed Tomography

X-ray Computed Tomography (X-ray CT) is an analytical technique used in materials science to non–destructively characterize features in variety of materials like polymers, metals, composites, and explosives. It also has the capability of imaging additively manufactured, machined and assembled parts and processes. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of material characteristics. Additionally, X-ray CT can obtain accurate measurements of dimensional and topographic variations as a result of different stimuli, and assess accuracy of material production. This study will focus on parts manufactured via metal additive manufacturing (AM). Although, AM produces parts faster and easier, the printing process can produce defects (pores and surface roughness) that undermine the part’s mechanical properties. The analysis of 3D printed objects has a strength in analysis in that the material has an STL file from which the item was printed, which is not available in many manufactured materials (i.e. foams) due to stochastic structures. For this study, the print accuracy of several 3D printed cylinders will be assessed via X-ray CT to determine optimal printing parameters for parts with less defects and stronger mechanical properties. This will be accomplished by having the original STL file serve as the baseline surface to compute difference in the CT rendering to calculate surface roughness for each cylinders.

36 MATERIALS SCIENCE↗

Terahertz Computed Tomography of NASA Thermal Protection System Materials

A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

Roth, D. J.↗

Incorporating Quantitative Single Photon Emission Computed Tomography into Radiation Therapy Treatment Planning for Lung Cancer: Impact of Attenuation and Scatter Correction on the Single Photon Emission Computed Tomography-Weighted Mean Dose and Functional Lung Segmentation

Purpose: To assess the impact of attenuation and scatter corrections on the calculation of single photon emission computed tomography (SPECT)-weighted mean dose (SWMD) and functional volume segmentation as applied to radiation therapy treatment planning for lung cancer. Methods and Materials: Nine patients with lung cancer underwent a SPECT lung perfusion scan. For each scan, four image sets were reconstructed using the ordered subsets expectation maximization method with attenuation and scatter corrections ranging from none to a most comprehensive combination of attenuation corrections and direct scatter modeling. Functional volumes were segmented in each reconstructed image using 10%, 20%, ..., 90% of maximum SPECT intensity as a threshold. Systematic effects of SPECT reconstruction methods on treatment planning using functional volume were studied by calculating size and spatial agreements of functional volumes, and V{sub 20} for functional volume from actual treatment plans. The SWMD was calculated for radiation beams with a variety of possible gantry angles and field sizes. Results: Functional volume segmentation is sensitive to the particular method of SPECT reconstruction used. Large variations in functional volumes, as high as >50%, were observed in SPECT images reconstructed with different attenuation/scatter corrections. However, SWMD was less sensitive to the type of scatter corrections. SWMD was consistent within 2% for all reconstructions as long as computed tomography-based attenuation correction was used. Conclusion: When using perfusion SPECT images during treatment planning optimization/evaluation, the SWMD may be the preferred figure of merit, as it is less affected by reconstruction technique, compared with threshold-based functional volume segmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose From Megavoltage Computed Tomography Imaging

Purpose: Megavoltage computed tomography (MVCT) can be used daily for imaging with a helical tomotherapy unit for patient alignment before treatment delivery. The purpose of this investigation was to show that the MVCT dose can be computed in phantoms, and further, that the dose can be reported for actual patients from MVCT on a helical tomotherapy unit. Methods and Materials: An MVCT beam model was commissioned and verified through a series of absorbed dose measurements in phantoms. This model was then used to retrospectively calculate the imaging doses to the patients. The MVCT dose was computed for five clinical cases: prostate, breast, head/neck, lung, and craniospinal axis. Results: Validation measurements in phantoms verified that the computed dose can be reported to within 5% of the measured dose delivered at the helical tomotherapy unit. The imaging dose scaled inversely with changes to the CT pitch. Relative to a normal pitch of 2.0, the organ dose can be scaled by 0.67 and 2.0 for scans done with a pitch of 3.0 and 1.0, respectively. Typical doses were in the range of 1.0-2.0 cGy, if imaged with a normal pitch. The maximal organ dose calculated was 3.6 cGy in the neck region of the craniospinal patient, if imaged with a pitch of 1.0. Conclusion: Calculation of the MVCT dose has shown that the typical imaging dose is approximately 1.5 cGy per image. The uniform MVCT dose delivered using helical tomotherapy is greatest when the anatomic thickness is the smallest and the pitch is set to the lowest value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computer-Assisted Diagnosis System for Breast Cancer in Computed Tomography Laser Mammography (CTLM)

Computed tomography laser mammography (Eid et al. Egyp J Radiol Nucl Med, 37(1): p. 633–643, 1) is a non-invasive imaging modality for breast cancer diagnosis, which is time-consuming and challenging for the radiologist to interpret the images. Some issues have increased the missed diagnosis of radiologists in visual manner assessment in CTLM images, such as technical reasons which are related to imaging quality and human error due to the structural complexity in appearance. The purpose of this study is to develop a computer-aided diagnosis framework to enhance the performance of radiologist in the interpretation of CTLM images. The proposed CAD system contains three main stages including segmentation of volume of interest (VOI), feature extraction and classification. A 3D Fuzzy segmentation technique has been implemented to extract the VOI. The shape and texture of angiogenesis in CTLM images are significant characteristics to differentiate malignancy or benign lesions. The 3D compactness features and 3D Grey Level Co-occurrence matrix (GLCM) have been extracted from VOIs. Multilayer perceptron neural network (MLPNN) pattern recognition has developed for classification of the normal and abnormal lesion in CTLM images. The performance of the proposed CAD system has been measured with different metrics including accuracy, sensitivity, and specificity and area under receiver operative characteristics (AROC), which are 95.2, 92.4, 98.1, and 0.98%, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probing water distribution in compressed fuel-cell gas-diffusion layers using X-ray computed tomography

X-ray computed tomography was used to investigate geometrical land and channel effects on spatial liquid-water distribution in gas-diffusion layers (GDLs) of polymer-electrolyte fuel cells under different levels of compression. At low compression, a uniform liquid-water front was observed due to water redistribution and uniform porosity; however, at high compression, the water predominantly advanced at locations under the channel for higher liquid pressures. Lastly, at low compression, no apparent correlation between the spatial liquid water and porosity distributions was observed, whereas at high compression, a strong correlation was shown, indicating a potential for smart GDL architecture design with modulated porosity.

25 ENERGY STORAGE↗

EVALUATION OF BALLISTIC DAMAGE IN AN ENCAPSULATED CERAMIC PANEL VIA X-RAY COMPUTED TOMOGRAPHY

X-ray computed tomography (XCT) is an important non-destructive evaluation technique for revealing the spatial distribution of ballistically-induced damage in ceramics. The level of detection and resolution of damage depends on the size of the sample and the parameters of the XCT approach (e.g., focal spot size, magnification, etc.). Previous and ongoing work in this area includes assessment of ballistically induced damage in both individual ceramic targets and ceramic armor panels. Ballistic damage in an encapsulated ceramic armor panel with a metal backing has been scanned and extensively evaluated using XCT 2-D and 3-D analysis. The purpose of using XCT evaluation in this study was to better characterize and understand all of the detectable damage. This information can be used to correlate damage features and types with the physical processes of damage initiation and growth. XCT scans and analyses of damage in the panel will be shown and discussed. This will include virtual 3-D solid visualizations and some quantitative analysis of damage features.

36 MATERIALS SCIENCE↗

Dimensional Control of Micro Components with Synchrotron Computed Tomography

An advantage of Computed Tomography (CT) is the coordinate measurement capability of small inner structures, which are not accessible with classical measurement techniques. Using the advantages of synchrotron radiation CT measurements of parts with sizes of a few millimeters are performed at BAMline of BESSY II and are expected to be used as references for further dimensional measurements with micro CT. Previous investigations were focused on external gears, which are accessible with standard Coordinate Measurement Machines (CMMs). To obtain information about the accuracy of dimensional measurements of internal gears with CT, reference data have been measured by a tactile-optical CMM. This information is used to evaluate the performance of the CT. In addition to the first results for the evaluation of internal gear flanks, new measurements of different gear materials (steel and zirconium dioxide) will be presented. For functional evaluation, gear flanks are a matter of particular interest. Form deviations are analyzed with respect to the different gear materials to establish CT measurements as technology in the field of quality assurance and to compare the different manufacturing processes.

07 ISOTOPE AND RADIATION SOURCES↗

Ultrafast three-dimensional x-ray computed tomography

X-ray computed tomography (CT) is a well established visualization technique in medicine and nondestructive testing. However, since CT scanning requires sampling of radiographic projections from different viewing angles, common CT systems with mechanically moving parts are too slow for dynamic imaging, for instance of multiphase flows or live animals. Here, we introduce an ultrafast three-dimensional x-ray CT method based on electron beam scanning, which achieves volume rates of 500 s{sup -1}. Primary experiments revealed the capability of this method to recover the structure of phase boundaries in gas-solid and gas-liquid two-phase flows, which undergo three-dimensional structural changes in the millisecond scale.

42 ENGINEERING↗