Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Magnetic resonance imaging of the calcaneus: preliminary assessment of trabecular bone-dependent regional variations in marrow relaxation time compared with dual X-ray absorptiometry

RATIONALE AND OBJECTIVES: Marrow transverse relaxation time (T2*) in magnetic resonance (MR) imaging may be related to the density and structure of the surrounding trabecular network. We investigated regional variations of T2* in the human calcaneus and compared the findings with bone mineral density (BMD), as measured by dual X-ray absorpiometry (DXA). Short- and long-term precisions were evaluated first to determine whether MR imaging would be useful for the clinical assessment of disease status and progression in osteoporosis. METHODS: Gradient-recalled echo MR images of the calcaneus were acquired at 1.5 T from six volunteers. Measurements of T2* were compared with BMD and (for one volunteer) conventional radiography. RESULTS: T2* values showed significant regional variation; they typically were shortest in the superior region of the calcaneus. There was a linear correlation between MR and DXA measurements (r = .66 for 1/T2* versus BMD). Differences in T2* attributable to variations in analysis region-of-interest placement were not significant for five of the six volunteers. Sagittal MR images had short- and long-term precision errors of 4.2% and 3.3%, respectively. For DXA, the precision was 1.3% (coefficient of variation). CONCLUSION: MR imaging may be useful for trabecular bone assessment in the calcaneus. However, given the large regional variations in bone density and structure, the choice of an ROI is likely to play a major role in the accuracy, precision, and overall clinical efficacy of T2* measurements.

Non-NASA Center↗

Globular-cluster stars - Results of theoretical evolution and pulsation studies compared with the observations.

Survey of recently published studies on globular clusters, and comparison of stellar evolution and pulsation theory with reported observations. The theory of stellar evolution is shown to be capable of describing, in principle, the behavior of a star through all quasi-static stages. Yet, as might be expected, estimates of bulk properties obtained by comparing observations with results of pulsation and stellar atmosphere theory differ somewhat from estimates of these same properties obtained by comparing observations with results of evolution theory. A description is given of how such estimates are obtained, and suggestions are offered as to where the weak points in each theory may lie.

Iben, I., Jr.↗

Comparative cut-bar thermal conductivity apparatus.

Construction details, error analysis, and typical data for a rapid comparative device for thermal conductivity measurements are presented. The apparatus consists of a comparative cut-bar arrangement contained in a bell-jar. The cylinder shaped specimen is placed between two ARMCO-iron meter bars of the same diameter. The upper bar is equipped with a heater, while the lower one is terminated in a heat sink. The temperature gradient along the bars is measured with a series of copper/constantan microthermocouples, spot welded to them. The assembly is held together by loading the bars to a desired pressure, via a pneumatic cylinder. Contact resistance at the boundaries between the specimen and the meter bars is minimized by using a Hg/In/Ga alloy film at the interface and sufficient loading force. The gradients determined for the meter bars then may be extrapolated to the boundaries yielding the temperature drop along the specimen. Using two different length specimens, the magnitude of the temperature drop across the interface can be computed, or the true gradient along the specimen can be obtained from the difference in overall temperature drops and lengths.

Gaal, P. S.↗

Comparative evaluation of solar, fission, fusion, and fossil energy resources, part 3

The role of nuclear fission reactors in becoming an important power source in the world is discussed. The supply of fissile nuclear fuel will be severely depleted by the year 2000. With breeder reactors the world supply of uranium could last thousands of years. However, breeder reactors have problems of a large radioactive inventory and an accident potential which could present an unacceptable hazard. Although breeder reactors afford a possible solution to the energy shortage, their ultimate role will depend on demonstrated safety and acceptable risks and environmental effects. Fusion power would also be a long range, essentially permanent, solution to the world's energy problem. Fusion appears to compare favorably with breeders in safety and environmental effects. Research comparing a controlled fusion reactor with the breeder reactor in solving our long range energy needs is discussed.

Clement, J. D.↗

Comparative Evaluation of Phase 1 Results from the Energy Conversion Alternatives Study (ECAS)

Ten advanced energy conversion systems for central-station, based-load electric power generation using coal and coal-derived fuels which were studied by NASA are presented. Various contractors were selected by competitive bidding to study these systems. A comparative evaluation is provided of the contractor results on both a system-by-system and an overall basis. Ground rules specified by NASA, such as coal specifications, fuel costs, labor costs, method of cost comparison, escalation and interest during construction, fixed charges, emission standards, and environmental conditions, are presented. Each system discussion includes the potential advantages of the system, the scope of each contractor's analysis, typical schematics of systems, comparison of cost of electricity and efficiency for each contractor, identification and reconciliation of differences, identification of future improvements, and discussion of outside comments. Considerations common to all systems, such as materials and furnaces, are also discussed. Results of selected in-house analyses are presented, in addition to contractor data. The results for all systems are then compared.

Source record↗

Geologic guide to the island of Hawaii: A field guide for comparative planetary geology

With geological data available for all inner planets except Venus, we are entering an era of true comparative planetary geology, when knowledge of the differences and similarities for classes of structures (e.g., shield volcanoes) will lead to a better understanding of general geological processes, regardless of planet. Thus, it is imperative that planetologists, particularly those involved in geological mapping and surface feature analysis for terrestrial planets, be familiar with volcanic terrain in terms of its origin, structure, and morphology. One means of gaining this experience is through field trips in volcanic terrains - hence, the Planetology Conference in Hawaii. In addition, discussions with volcanologists at the conference provide an important basis for establishing communications between the two fields that will facilitate comparative studies as more data become available.

Greeley, R.↗

An initial comparative assessment of orbital and terrestrial central power systems

Orbital solar power plants, which beam power to earth by microwave, are compared with ground-based solar and conventional baseload power plants. Candidate systems were identified for three types of plants and the selected plant designs were then compared on the basis of economic and social costs. The representative types of plant selected for the comparison are: light water nuclear reactor; turbines using low BTU gas from coal; central receiver with steam turbo-electric conversion and thermal storage; silicon photovoltaic power plant without tracking and including solar concentration and redox battery storage; and silicon photovoltaics.

Caputo, R.↗

Comparative orthostatic responses - Standing vs. head-up tilt

In both physiologic and clinical studies, standing is often loosely equated with head-up tilt (HUT) although the cardiovascular effects of these variants of orthostasis have not been formally compared, except for heart rate. The effects of HUT and standing were measured noninvasively in male volunteers satisfying identical criteria for age and normal status. In both postures, there were significant increases in heart rate, pre-ejection period, isovolumic contraction time, and the ratio of pre-ejection to ejection period, and significant decreases in ejection period and ejection time index. All of these changes were greater for standing than for tilt. Pulse transmission time changed significantly (-14%) only with tilt. We conclude that head-up tilt and standing are rather comparable but not physiologically identical forms of orthostasis.

Spodick, D. H.↗

The effect of technology advancements on the comparative advantages of electric versus chemical propulsion for a large cargo orbit transfer vehicle

Techniques for sizing electrically or chemically propelled orbit transfer vehicles and analyzing fleet requirements are used in a comparative analysis of the two concepts for various levels of traffic to geosynchronous orbit. The vehicle masses, fuel requirements, and fleet sizes are determined and translated into launch vehicle payload requirements. Technology projections beyond normal growth are made and their effect on the comparative advantages of the concepts is determined. A preliminary cost analysis indicates that although electric propulsion greatly reduces launch vehicle requirements substantial improvements in the cost and reusability of power systems must occur to make an electrically propelled vehicle competitive.

Rehder, J. J.↗

Comparative vibration environments of transportation vehicles

Measured vibration data are presented for a number of air and surface vehicles. Consideration is given to the importance of direction effects; of vehicle operating modes such as takeoff, cruise, and landing; and of measurement location on the level and frequency of the measurements. Various physical measurement units or descriptors are used to quantify and compare the data. Results suggest the range of vibration associated with a particular mode of transportation and illustrate the comparative levels in terms of each of the descriptors. Collectively, the results form a data base which may be useful in assessing the ride of existing or future systems relative to vehicles in current operation. In addition, subjective response data obtained from vibration simulator studies are presented to illustrate human response characteristics as well as to indicate a laboratory approach for the development of ride-quality criteria.

Stephens, D. G.↗

Window comparator for voltages

Circuit determines whether voltage is within preselected range of voltage levels.Device requires fewer components than previous window comparators and is less susceptible to errors from reference drift. Comparator is useful in process-control circuitry, measuring instruments, and checkout equipment.

Black, J. M.↗

Optical comparator uses holographic subtraction

Integrated optical comparator compares reference and signal voltages by their effects on coherent light beam. If both voltages are same, beam is essentially unperturbed. If voltages differ, light is deflected by previously recorded hologram to detector.

Vahey, D. W.↗

Earth-to-orbit reusable launch vehicles: A comparative assessment

A representative set of space systems, functions, and missions for NASA and DoD from which launch vehicle requirements and characteristics was established as well as a set of air-breathing launch vehicles based on graduated technology capabilities corresponding to increasingly higher staging Mach numbers. The utility of the air-breathing launch vehicle candidates based on lift-off weight, performance, technology needs, and risk was assessed and costs were compared to alternative concepts. The results indicate that a fully reusable launch vehicle, whether two stage or one stage, could potentially reduce the cost per flight 60-80% compared to that for a partially reusable vehicle but would require advances in thermal protection system technology. A two-stage-to-orbit, parallel-lift vehicle with an air-breathing booster would cost approximately the same as a single-stage-to-orbit vehicle, but the former would have greater flexibility and a significantly reduced developmental risk. A twin-booster, subsonic-staged, parallel-lift vehicle represents the lowest system cost and developmental risk. However, if a large supersonic turbojet engine in the 350,000-N thrust class were available, supersonic staging would be preferred, and the investment in development would be returned in reduced program cost.

Chase, R. L.↗

Thermal-conductivity measurements of tungsten-fiber-reinforced superalloy composites using a thermal-conductivity comparator

The thermal conductivity (TC) of tungsten-fiber-reinforced superalloys was determined for two composite systems by using a thermal conductivity standard from the National Bureau of Standards and a comparator and technique developed for that purpose. The results were compared with TC data for the nickel-base alloy MAR-M200. The technique lends itself to applications involving thin specimens, such as thin-walled turbine blades. The TC's of the composite systems were considerably higher in both the longitudinal and transverse directions than that of the monolithic superalloys used as the matrices.

Westfall, L. J.↗

Comparative evaluation of woven graphite-epoxy composites

A comparative evaluation of some of the mechanical properties of woven graphite-epoxy composites are discussed. In particular, the types of weaves and the resin contents were chosen for comparison. The types of weaves selected are plain weave, satin weave, and tridirectional weave. The composites made of the fabrics are compared to composites made from unidirectional tapes under static and fatigue loading. During static loading, acoustic emission events were monitored. Also, examinations of fracture surfaces and polished sections both away from the fracture surface, and of virgin specimens under an electron microscope are discussed.

Hanagud, S.↗

Comparative evaluation of woven graphite-epoxy composites

A comparative evaluation of some of the mechanical properties of woven graphite-epoxy composites have been discussed in this report. In particular the types of weaves and the resin contents have been chosen for comparison. The types of weaves selected are plain weaves, satin weave and tri-directional weave. The composites made of these fabrics have been compared to composites made from unidirectional tapes under static and fatigue loading. During static loading acoustic emission events have been monitored. Also, examinations of fracture surface and polished sections of specimens away from the fracture surface under an electron microscope have been discussed.

Hanagud, S.↗

A study of the comparative performance of six lightning warning systems

An analysis of mining explosive accident reports indicates a need for clear and ample warning of approaching electrical storms to reduce injuries/fatalities due to lightning induced premature detonation. Six lightning warning devices were comparatively evaluated at three test sites. The devices tested were: (1) flash counter, (2) corona point, (3) radioactive probe, (4) field mill, (5) azimuth/range locator, and (6) triangulation locator. The test sites were chosen to provide system evaluation under varied thunderstorm conditions. The devices were tested at San Antonio, Texas, Kennedy Space Center, Florida and Langmuir Laboratory, New Mexico. Comparative performance is reviewed in terms of alarm reliability, false alarm, and failure to alarm probabilities. Lightning warning system requirements and methods of relating warning criteria to explosive hazard are discussed.

Johnson, R. L.↗