Integration and commissioning plan of Full Flow Purifier at Muon Campus

The Full Flow Purifier for Fermilab's Muon Campus uses a charcoal bed surrounded by a liquid nitrogen jacket to purify up to 240 g/s of helium gas. Fabrication by Ability Engineering Technology Inc. has been completed and the purifier delivered to Fermilab. It is the largest purifier to be used at Fermilab based on both capacity and size. A previous paper discussed the design of purifier for various operational conditions and horizontal shipping. The purifier is designed to withstand 5g force in vertical and 2g force in lateral and longitudinal directions. Transportation experience from vendor to Fermilab and within site is discussed. Integration of the purifier involved design and fabrication of a liquid nitrogen transfer line, regeneration system, and helium piping to connect it to Muon Campus cryogenic system. It also involved establishing electrical, instrumentation and controls connections to the system. Integration of the purifier is discussed in detail. The purifier is to be commissioned using up to 4 MYCOM helium compressors to supply helium and liquid nitrogen supplied by a 60,000-liter tank. Actual effectiveness of the 3-stream heat exchanger is to be estimated based on measured temperatures and flow rate. Impurity levels will be monitored at inlet and outlet of the purifier. Theoretical adsorption capacity of the purifier is calculated based on the measured temperatures and flowrates and is compared to actual adsorption capacity over time.

Subedi, J. [Fermilab] (ORCID:0009000185837576)

Design and Commissioning of a Deuterium-Tritium Gas Delivery System for Muon Catalyzed Fusion in a Diamond Anvil Cell

We report the design, commissioning, and operation of deuterium-deuterium (DD) and deuterium-tritium (DT) gas delivery systems developed to load a diamond anvil cell (DAC) beam target for muon-catalyzed fusion (muCF). The DAC approach enables DT fuel to be compressed to GPa pressures at more than twice the liquid density and heated from cryogenic temperatures through 500 K, opening access to a substantially expanded parameter range for muCF kinetics and yield measurements. In this approach, DT is cryo-condensed to a liquid in a minichamber and then compressed in the DAC using a helium-driven pneumatic membrane, achieving high pressures in a millimeter-scale DT sample volume. A DD gas delivery system was designed and used to validate the experimental apparatus, measure the gas quantities needed for filling, develop operational experience, and collect kinetics and yield data with DD targets. The DT gas delivery system adds tritium-specific capabilities for inventory minimization, secondary containment, and activity monitoring. The DT system integrates depleted uranium storage beds and a liquid helium cryogenic condenser used for pressure building and cryopumping. High-purity delivery is provided by a rapid-response palladium permeator. The system is housed in a helium-atmosphere glovebox held at negative pressure with continuous cleanup. We present the process and instrumentation design, a failure modes and effects analysis (FMEA), and data from the experiment's in situ Raman spectrometer, which provides direct confirmation of target loading and composition through the optically clear diamond anvils. The 2024 and 2025 DT campaigns achieved repeatable target fills and operation with no measurable tritium releases to the stack, demonstrating safe, high-purity DT loading at novel density-temperature conditions for muCF studies.

Koukina, Elena [Acceleron Fusion]

Commissioning of the neutron irradiation station at the University of Notre Dame

Cross section data for neutron-induced reactions are needed for applications in nuclear astrophysics, stockpile stewardship, and nuclear reactor design but often contain discrepancies and gaps. A neutron source with a high neutron flux, a well-characterized neutron energy distribution, and a wide range of available neutron energies is ideal for studying such reactions in order to improve on existing data and provide new experimental results. For this purpose, the Neutron Irradiation Station (NIS) was developed using the 7 Li(p,n) 7 Be reaction. Neutron energy profiles were obtained using 3 He spectrometers and neutron standards were used to determine the neutron flux using the activation method. The neutron energy profile was found to be quasi-monoenergetic and neutrons were produced at energies from 1 keV to 1 MeV. Finally, the flux at the production target was found to be (1.42 ± 0.20) x 10 8 s −1 cm −2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Design and commissioning of readout electronics for a $K$$^{0}_{L}$ and $μ$ detector at the Belle II experiment

The K-long and muon detector (KLM) constitutes the outer-most volume of the Belle II spectrometer at the interaction region of the SuperKEKB collider in Tsukuba, Japan. The KLM detector was partially upgraded since the Belle experiment by replacing many of its resistive-plate chambers with scintillators containing wavelength-shifting fibers and instrumenting it with silicon photomultipliers. Here, we describe the readout electronics, firmware, and software created to control and acquire data from the scintillators and resistive-plate chambers.

Belle II

Design and commissioning of the Correlated Gamma-Neutron Array for sCattering (CoGNAC)

The Correlated Gamma-Neutron Array for sCattering (CoGNAC) is a dual $n$-$γ$ detector array fielded at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center. Here, the detector array utilizes elpasolite detectors and liquid scintillators to perform measurements of neutron elastic and inelastic scattering cross sections and emitted particle angular distributions. This manuscript details the design and experimental setup of CoGNAC as well as some of the preliminary studies performed to select the elpasolite detectors deployed in the array. Examples of the analysis methods available to CoGNAC are given in the context of past CoGNAC measurements of neutron scattering reactions on 28 Si and 56 Fe.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Deuterium Extraction from Helium with a Vanadium Vacuum Permeator: Commissioning of the Tritium Extraction eXperiment (TEX)

Here, the Tritium Extraction eXperiment (TEX) is a forced-convection lead-lithium (PbLi) loop in the Safety and Tritium Applied Research (STAR) facility at Idaho National Laboratory (INL) with the purpose of providing validation data for the vacuum permeator tritium extraction concept. A vanadium tube of 1000 mm length, 12.7 mm outside diameter, and 0.50 mm wall thickness is installed in the test section of TEX. The installed vanadium tube is characterized to quantify impurity concentrations, surface chemistry, and microstructure to elucidate permeation phenomena observed in experimentation. Herein, the permeation properties of the vanadium tube are characterized by measuring deuterium permeation at 300 °C, 325 °C, and 350 °C at 100 kPa, 125 kPa, and 150 kPa total pressures with 5000 ppm deuterium in helium gas mixture in a once-through flow configuration. The hydrogen isotope permeation through the vanadium tube in the test section is measured with quadrupole mass spectrometers and the hydrogen isotope concentration in the feed and retentate gas stream is measured with gas chromatography. The transient permeation results are modeled with MELCOR-TMAP, a thermal-hydraulic tritium transport code, and compared well with literature data.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY

Rapid Commissioning of Large Machine Tools Using Finite Element-Based Correction of Geometric Errors

Large computer numerical control (CNC) machine tools derive their stiffness from monolithic cast iron bases or weldments that are sometimes integral to machine motion systems like box ways or guideways. However, the sheer size of castings and even floor flatness deviations result in dimensional errors in these systems, which manifest as machine motion errors. Typical geometric alignment processes rely on an iterative approach, where measurements are taken to assess alignment (straightness, squareness, and parallelism), followed by adjustment of the machine supports (fixators or leveling pads), which can take weeks even for an experienced operator. Conversely, a novel method is proposed to shorten the correction time by eliminating the trial-and-error process in favor of a more deterministic approach guided by a finite element (FE) method. A feasibility study is conducted on a CNC polymer hybrid machine, with a steel weldment frame, supported by six leveling pads. An FE model of the frame is utilized to obtain recommended leveling pad adjustments, based on measurement of machine errors taken using a laser tracker. After a single adjustment cycle, measurements reveal that geometric errors of the machine tool are reduced from 2.22 mm of flatness deviation to 0.32 mm, achieving an 85.6% reduction. Furthermore, the entire process including measurement, adjustment, and assessment is completed in just 6 h by two operators who are not professional service engineers. In conclusion, this methodology demonstrates feasibility for scaling up, especially to large, high-precision CNC machine tools with bases mounted by fixators, offering the capability for bidirectional adjustment.

42 ENGINEERING

Platform for Remote Deployment and Training for Enhanced Building Operation Practices (Building Re-Tuning and On-going Commissioning)

While a building’s energy usage is driven largely by its design and use, building operator behavior has a strong influence on its energy consumption. This project developed and piloted a specific, data-driven coaching methodology to help operators understand how they can adjust operations and/or affect no/low-cost repairs or upgrades to their specific building HVAC systems to reduce energy consumption. Named BuildingCoach, the operational optimization method used is based on the Building Re-tuning approach developed by the Pacific Northwest National Laboratory. A building operations analytics market has matured over the past decade, though its potential to affect energy-saving changes has not been fully realized. Training operators to understand the methods for operational optimization with the explicit approach of using building-system performance data is hypothesized to create a more effective, longer lasting result in building energy efficiency, and this strategy is the fundamental premise of this project. With the support of an Industry Advisory Board, the project succeeded in developing materials and recruiting for and delivering three pilot cohorts. Deliverables included twenty-two self-paced training modules (accessed via a Learning Management System) and a web-based platform that includes access to real-time building system data and a repository for building system documentation. The project set out to have 100 participants from 50 buildings in three pilot cohorts. In the end, there were 28 participants from 17 buildings, i.e., a significant shortfall. The first two pilot cohorts had only two buildings in each, and this was partially due to difficulties in deploying the Building Operator Coaching Solution (“the BOCS”), which is technology that extracts the data from the controls network and presents it as prescribed for coaching. In the third cohort, the project team deployed the BOCS successfully to 13 buildings, the methodology was piloted as intended, and numerous opportunities for optimization were identified. The BuildingCoach business plan charts a path to an economically sustainable effort. However, even with a licensing model captured in the final version of the business plan, the scalability is still limited to keeping less than 1,000 buildings affected by 2033. Even so, there are unexplored paths to greater scalability that are being considered. CUNY BPL is working to perpetuate and grow the use of BuildingCoach. As of this writing, about twenty buildings have either been connected or will be connected with operators coached / to be coached in the NYC municipal portfolio, twelve buildings across four campuses in NY State will use BuildingCoach, a NY upstate county wishes for six or seven buildings to participate with the support of funding from NYSERDA, and others have also expressed interest. In the decades to come, there will be an increasing percentage of large and mid-sized buildings that incorporate automated system optimization (ASO), and the building operators’ role will shift to spend more time on maintenance and monitoring. Meanwhile, programs such as BuildingCoach will play a critical role in optimizing operations. And, regardless of the emergence of ASO, operators will still need to understand how their systems operate so that they can monitor them properly. Within that context, BuildingCoach is an important step towards operators’ understanding of efficient building system operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Installation and Commissioning of the SBC-LAr10 Detector at Fermilab

This report describes the progress towards a scalable detector capable of quasi-background-free detection of sub-keV nuclear recoils under DOE award DE-SC0024254. Work supported by this award follows two distinct thrusts: (1) the first calibration of sensitivity to sub-keV nuclear recoils in a liquid-noble bubble chamber, based on data taken in a prototype liquid xenon bubble chamber run previously at Northwestern University, and (2) the successful assembly and installation of the 10-kg liquid argon bubble chamber SBC-LAr10 in the MINOS underground area at Fermilab. These accomplishments have paved the way for the precision calibration of SBC-LAr10 in the MINOS underground area at Fermilab in the coming year, which will use novel calibration techniques to measure the potential of the liquid noble bubble chamber technology for the detection of GeV-scale dark matter particles and the measurement of coherent elastic nuclear scattering by reactor anti-neutrinos (CEvNS).

47 OTHER INSTRUMENTATION

State Spotlight on Resilience: The Washington Utilities and Transportation Commission’s Wildfire Mitigation Plans

Wildfires present a significant risk to critical infrastructure, endangering energy systems by damaging transmission lines and imposing a variety of costs on utilities and their customers. Wildfires have increased nationally in both extent and intensity as vegetation conditions become drier and wind patterns become more turbulent. Aging infrastructure may also cause transmission lines to ignite vegetation.

24 POWER TRANSMISSION AND DISTRIBUTION

National Laboratory of the Rockies: Pennsylvania Public Utility Commission/ Technical Utility Services Bureau Distribution System Resilience Deep Dive 2025

The following is a summary of the National Laboratory of the Rockies (NLR) - Pennsylvania PUC/ Technical Utility Services Bureau (TUS) Distribution System Resiliency Deep-Dive project. This is work that NLR performed to provide the support that the TUS requested under the Resources and Support for State Energy Offices & Regulators (RASOR) program.

29 ENERGY PLANNING, POLICY, AND ECONOMY

A Guide for Public Utility Commissions: Building Internal Technical Capacity and Recruiting Talent for Grid Resilience

This guide offers insight into how PUCs can strategically expand their technical workforce to meet evolving gird resilience demands. It outlines critical skill sets needed to support informed regulatory decision-making around resilience, such as modeling and weather forecasting, electric power systems analysis, and advanced data interpretation. In addition, it provides strategies for developing technical talent both internally and through additional recruitment efforts. Two appendices provide a list of grid resilience training resources and a compendium of sample job descriptions that reflect grid resilience technical expertise for PUC consideration.

24 POWER TRANSMISSION AND DISTRIBUTION