Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Buildings Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Integration of Wi-Fi Location-Based Services to Optimize Energy Efficient Commercial Building Operations

This project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at commercial buildings located in Saint Paul, MN; Madison, WI; New York City; and Fort Worth, TX.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large-Scale Simulation of Regional Demand Flexibility Implementation and Customer Economic Impact

The Distribution System Operator with Transactive (DSO+T) study conducted a large-scale simulation of over 60,000 customers in a region the size of Texas to demonstrate the effective coordination of distributed energy resources (DERs) in commercial and residential buildings. The integrated simulation included both the bulk (wholesale generation and transmission) and distribution systems. The DERs (including batteries, electric vehicles, air conditioning, and water heaters) participated in a transactive energy retail market that was integrated into an existing competitive wholesale market. The engineering and economic performance of the resulting demand flexibility was evaluated over annual simulations for both moderate and high renewable generation scenarios. A detailed parametric cost model was developed to enable detailed economic analysis of key stakeholders. In addition, fixed and dynamic customer tariffs were designed and applied to the customer population. This allowed the impact on annual customer bills to be analyzed for various building types (residential versus commercial; single- versus multi-family). This paper presents results showing the relative flexibility of batteries, electric vehicles, and building loads throughout the year and under different renewable scenarios. This feeds a detailed breakdown of the impact this flexibility has on the operating costs of the grid and the resulting net economic benefit. Finally, the study showed that practically all customer classes (including non-participating customers) save money under the proposed demand flexibility scheme. The study found overall net annual economic savings of $3.3-5.0B for a region the size of Texas equating to average customer bill savings of 10-16%.

Reeve, Hayden M.↗

Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings

Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Artificial Intelligence for Enhancing Multiscale Analysis: Buildings Focus

This project aims to develop multi-scale building energy data, potentially improving the representation of the U.S. buildings sector in GCAM-USA, an U.S.-focused human-energy-Earth systems model. Existing building energy datasets are typically limited to national or regional levels, which constrains the ability of models to capture fine-scale human-energy-Earth systems interactions and reduces their relevance for decision-making on issues such as energy security, resilience, and energy planning. By leveraging AI and advanced data integration methods, this work fuses multiple existing datasets to enhance the physical and geographic representation of both residential and commercial building energy use. So far, progress includes processing residential building data, designing the data structure for commercial buildings, and testing AI approaches for integrating datasets and addressing spatial-temporal gaps. This effort can not only advances GCAM-USA’s capability in modeling the buildings sector but also supports broader DOE missions, such as developing digital testbeds, enhancing grid resilience analysis, and improving building–energy system modeling at decision-relevant scales.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Savings Results from Small Commercial Building Retrofits in the US

Small commercial buildings, or those comprising less than 50,000 square feet of floor area, represent 94% of U.S commercial buildings by count and consume approximately 8% of the nation’s primary energy; as such, they represent a largely unexploited opportunity for energy savings. Small commercial buildings also represent a large economic market—the National Institute of Building Sciences (NIBS) estimated the small commercial retrofit market at USD 35.6 billion. Despite the prominence of small commercial buildings and the economic opportunity for energy retrofits, many energy efficiency programs focus on large commercial buildings, and create efficiency solutions that do not meet the needs of the small commercial market. This paper presents an analysis of 34 small commercial case study projects that implemented energy efficiency retrofits. This paper contributes to the existing building retrofit body of knowledge in the following ways: (1) it identifies the decision criteria used by small commercial building stakeholders that decided to complete an energy retrofit; (2) it identifies the most commonly implemented efficiency measures in small commercial buildings, and discusses why this is the case; and (3) it provides empirical evidence about the efficacy of installing single energy efficiency measures (EEMs) compared to packages of EEMs in small commercial buildings by reporting verified energy savings. To the authors’ knowledge, this paper is the first to catalog decision criteria and energy savings for the existing small commercial buildings market, and this research illustrates that small commercial building decision-makers seem most motivated to retrofit their spaces by energy cost savings and operational concerns. Furthermore, small commercial building decision-makers opted to implement single-system retrofits in fifteen (15) of the thirty-four cases studied. Finally, this research documents the improved savings, in the small commercial buildings market, associated with a more integrated package of EEMs compared to a single-system approach, achieving approximately 10% energy savings for a single-system approach and more than 20% energy savings for integrated approaches. These savings translate to CO2 savings of 1,324,000 kgCO2/year to 2,647,000 kgCO2/year, respectively, assuming small commercial buildings are retrofit at a rate of 0.95% of the stock annually.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY20 Third Milestone Report for Advanced Techno-Economic Modeling for Geothermal Heat Pump Applications in Residential, Commercial, and Industry Buildings

This report summarizes the developments of an integrated simulation program for enabling simulation, auto-sizing, and optimization of geothermal heat pump systems. This work fulfills the following FY20 third milestone for WBS 2.5.5.3: Advanced Techno-Economic Modeling for Geothermal Heat Pump Applications in Residential, Commercial, and Industry Building.

15 GEOTHERMAL ENERGY↗

Commercial Building Planning and Retrofitting Strategy for Grid Services

The increasing integration of distributed energy resources (DERs) plays an important role in improving energy consumption efficiency. In September 2020, the Federal Energy Regulatory Commission (FERC) approved Order 2222 which opens wholesale electricity markets to small capacity DERs. The benefit of this new FERC Order 2222 is that DERs, such as rooftop solar panels and batteries, will be able to participate in regional electricity markets and provide grid services. Meanwhile, the planning and operation strategies of DERs are facing new challenges to account for the impact of the wholesale market with numerous uncertainty factors. Therefore, in this paper, we propose a new planning and retrofitting model for long-term commercial buildings that considers both DER investment and market participation. Specifically, we explore the capability of implementing DERs for grid services. The effectiveness of the proposed model is validated using real-world data. Simulation results also validate that participating in grid services can significantly increase revenues through appropriate building energy management and shorten the payback period of DER investments.

building energy management↗

Next Day Building Load Predictions based on Limited Input Features Using an On-Line Laterally Primed Adaptive Resonance Theory Artificial Neural Network.

Optimal integration of thermal energy storage within commercial building applications requires accurate load predictions. Several methods exist that provide an estimate of a buildings future needs. Methods include component-based models and data-driven algorithms. This work implemented a previously untested algorithm for this application that is called a Laterally Primed Adaptive Resonance Theory (LAPART) artificial neural network (ANN). The LAPART algorithm provided accurate results over a two month period where minimal historical data and a small amount of input types were available. These results are significant, because common practice has often overlooked the implementation of an ANN. ANN have often been perceived to be too complex and require large amounts of data to provide accurate results. The LAPART neural network was implemented in an on-line learning manner. On-line learning refers to the continuous updating of training data as time occurs. For this experiment, training began with a singe day and grew to two months of data. This approach provides a platform for immediate implementation that requires minimal time and effort. The results from the LAPART algorithm were compared with statistical regression and a component-based model. The comparison was based on the predictions linear relationship with the measured data, mean squared error, mean bias error, and cost savings achieved by the respective prediction techniques. The results show that the LAPART algorithm provided a reliable and cost effective means to predict the building load for the next day.

25 ENERGY STORAGE↗

Analysis & Tools to Spur Increased Deployment of “Waste Heat” Rejection/Recycling Hybrid Ground-source Heat Pump Systems in Hot, Arid or Semiarid Climates Like Texas

This project team analyzed supplemental heat rejection/recovery (SHR) devices or systems that could be used in hybrid ground source heat pump (HGHP) systems located in arid or semi-arid regions in southwestern U.S. Identification of effective SHR solutions would enhance the deployment of ground source heat pumps (GHP) in these regions. In a parallel effort, the team developed integrated GHP models that coupled the building load, heat pump, and ground loop subsystems and which could be applied to residential and commercial office buildings. Then GHP and HGHP performances could be compared in terms of operational performance and life-cycle costs. Several potential SHR devices were analyzed by applying two strategies: 1) to remove heat directly from the water in the ground loop before it enters the ground and 2) to remove heat in the refrigerant loop of the vapor compression cycle (VCC) of the heat pump so less heat is transferred to the water loop at the condenser of the VCC. Cooling towers, adsorption coolers, and thermoelectric liquid coolers were included in strategy 1, and expanded desuperheaters, thermosyphons, and an optimized VCC were included in strategy 2. Of all SHR devices analyzed, only the cooling tower provided a cost-effective performance enhancement. For the integrated GHP model, the project team selected the building load model HAMBASE and its powerful computational Simulink/MatLab platform, empirical performance map models of the heat pumps based upon manufacturers’ performance data, and a ground loop model developed by Oklahoma State University and rewritten for this project in Simulink/MatLab. The design process used GLHEPRO, also from Oklahoma State University, to size the borehole fields. The building load and ground loop models were compared with simulations from eQuest, ASHRAE 140-2008 standards, EnergyPlus, and GLHEPRO and were found to predict those subsystems’ performance well. The integrated GHP model was applied to a 195m 2 (2100ft 2 ) residential building and a 4,982m 2 (53,628ft 2 ) three-story commercial office building, and it ran 10-15 year simulations. The integrated GHP model and its Simulink platform provided residential data, ranging from seconds to years, and commercial office building data, ranging from minutes to years. A cooling tower model was coupled to the base case integrated GHP model for the residential building and the resulting HGHP system provided a cost-effective solution for the Austin, TX location. Simulations for both the residential and commercial building models were run with varying degrees of SHR (device/system not identified) and the results were found to significantly decrease installation costs, increase heat pump efficiency (lower entering water temperature), and prolong the lifetime of the borehole field. Lifetime cycle costs were estimated from the simulation results. Sensitivity studies on system operating performance and lifetime costs were performed on design parameters, such as construction materials, borehole length, borehole configuration and spacing, grout conductivity, and effects of SHR. While some of the results are intuitive, these studies provided quantitative estimates of improved performance and cost. One of the most important results of this sensitivity study is that overall system performance is very sensitive to these design parameters and that modeling and simulation are essential tools to design cost-effective systems.

15 GEOTHERMAL ENERGY↗

Dynamic Decarbonization through Autonomous Physics-Centric Deep Learning and Optimization of Building Operations (Abstract only)

This project directly addresses the primary goal of Area of Interest 2 in the CRADA call: to advance optimization-based integrated energy management systems in commercial and residential buildings. Pacific Northwest National Laboratory (PNNL) and its industry partner PassiveLogic aim to accomplish this by reaching three key objectives. First, to ensure a broad impact in the building controls industry, PNNL will extend its open-source library for predictive control synthesis by augmenting its capabilities with data-driven self-learning of building models and auto-calibration of predictive controllers. The effort will focus on building use cases selected in collaboration with PassiveLogic. The team will specifically address the development of methods for data-driven adaptation of building models, investigation of model architectures that best address specific building types, and automated synthesis of differentiable predictive controllers that optimize diverse objectives. Second, PNNL will collaborate with PassiveLogic to integrate the aforementioned methods with PasiveLogic’s advanced controls platform. The collaborative integration effort will inform the developments under the first objective by providing specific data on the attainable performance of model learning on resource-constrained edge computing platforms. This software integration effort will increase the technical maturity of the developed libraries by exploring the use of software integration tools and methods. Third, PNNL and PassiveLogic will work to improve the technology readiness of the developed predictive controllers by testing their performance in relevant test environments, such as high-fidelity simulation, hardware in the loop, and actual test buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The BayREN Integrated Commercial Retrofits (BRICR) Project: An Introduction and Preliminary Results

BayREN Integrated Commercial Retrofits (BRICR) is a DOE-funded project which aims to enhance the capacity of energy efficiency programs to recruit participants, develop retrofits, and measure outcomes in small and medium-sized commercial buildings, a sector notoriously hard to reach and expensive to serve, that accounts for 2/3 of US commercial floor space. To address these barriers, BRICR leverages existing incentives, financing, data, and open source software to facilitate two paths for comprehensive improvements: a deep energy retrofit, or serial upgrades integrated into capital improvement and maintenance cycles. BRICR is developing an integrated workflow for iterative energy modeling of commercial buildings for city energy program managers and auditors - starting with mass building-scale simulation based on public records and proceeding through audit, retrofit, and measurement and verification stages. BRICR builds on existing tools including LBNL’s CBES, NREL’s OpenStudio, PNNL’s Audit Template, and DOE’s BuildingSync and SEED PlatformTM. At each stage, BRICR uses available information to inform simulations (starting with public records but iteratively augmented with observations from energy program staff) to improve the quality of the models that inform decision making. This paper presents initial results from energy models of 1699 office and retail buildings in San Francisco. Building stock data from public records were translated to create a BuildingSync file for each building which was stored in SEED. Each BuildingSync file was then translated to multiple OpenStudio Workflow files for EnergyPlus simulation to estimate energy savings of energy conservation measures (ECM). Energy savings predictions for each ECM were written back to an updated BuildingSync file for each building and re-uploaded to SEED. The distribution of baseline energy simulations was calibrated against the publicly disclosed distribution of energy benchmarking data to increase confidence in results.

Piette, M↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost estimates of production scale semitransparent organic photovoltaic modules for building integrated photovoltaics

Building integrated photovoltaics (BIPVs) are attached to commercial and residential structures to enable solar energy harvesting. While conventional Si photovoltaics (PVs) are dominant in the current market, second and third generation thin film solar cells based on amorphous Si, CdTe, CIGS, perovskites or organic photovoltaics (OPVs) are often considered as an alternative for BIPV applications since they may offer reduced costs compared to Si PVs. Indeed, recent advances in performance suggest that lightweight, flexible and visibly transparent OPVs can potentially be integrated into windows or other applications to which Si PVs are less well suited. Here, we estimate the cost of high efficiency, semitransparent OPVs (ST-OPVs) based on solution processing in a roll-to-roll (R2R) manufacturing line. Assuming modules with 10% power conversion efficiency (PCE), a 70% geometric fill factor (GFF), and 95% inverter efficiency, we anticipate a %1.6 per Wp module manufacturing cost that includes the cost of the microinverter to condition the OPV dc output to be compatible with the ac line voltage of the building. The materials and inverter cost comprise ~90% of the total module cost. Hence, with simplified material synthesis and a lower inverter cost, including marginally improved PCE and GFF, we expect the cost can be as low as $0.47 per Wp. Here, while the module costs ~60% of the average (uninstalled) double-pane window, we expect the payback period can be as short as 2 to 6 years, suggesting that OPVs can be an economic and attractive candidate for BIPV applications.

14 SOLAR ENERGY↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Small Business Voucher CRADA Report: Natural Gas Powered HVAC System for Commercial and Residential Buildings

Be Power Tech is commercializing BeCool, the first integrated electricity-producing heating, ventilation, and air conditioning (HVAC) system using a non-vapor compression cycle (VCC), packaged rooftop HVAC unit that also produces base-load electricity, heating, ventilation, and air conditioning. BeCool is a distributed energy resource with energy storage that eliminates the tremendous peak electricity demand associated with commonly used electricity-powered vapor compression air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Low Voltage DC Power Electronic Hub to Support Buildings

This paper presents the communication, control, and architecture, for a low voltage (nominal 480V) hybrid AC/DC microgrid for supporting small commercial buildings with critical data center loads. The proposed system is based on a dc-power electronic hub (PEH) that seamlessly integrates renewable energy resources, energy storage, and back-up generation to support commercial building economical energy management and reliability. This PEH concept provides a parallelization of critical power to the commercial and industrial buildings leading to increased efficiency and reliability compared to traditional uninterruptable power supplies. The demonstration of the proposed PEH architecture and controls is conducted through a controller hardware in the loop validation.

Starke, Michael↗