Assessing residential PM 2.5 concentrations and infiltration factors with high spatiotemporal resolution using crowdsourced sensors

Building conditions, outdoor climate, and human behavior influence residential concentrations of fine particulate matter (PM 2.5 ). To study PM 2.5 spatiotemporal variability in residences, we acquired paired indoor and outdoor PM 2.5 measurements at 3,977 residences across the United States totaling >10,000 monitor-years of time-resolved data (10-min resolution) from the PurpleAir network. Time-series analysis and statistical modeling apportioned residential PM 2.5 concentrations to outdoor sources (median residential contribution = 52% of total, coefficient of variation = 69%), episodic indoor emission events such as cooking (28%, CV = 210%) and persistent indoor sources (20%, CV = 112%). Residences in the temperate marine climate zone experienced higher infiltration factors, consistent with expectations for more time with open windows in milder climates. Likewise, for all climate zones, infiltration factors were highest in summer and lowest in winter, decreasing by approximately half in most climate zones. Large outdoor–indoor temperature differences were associated with lower infiltration factors, suggesting particle losses from active filtration occurred during heating and cooling. Absolute contributions from both outdoor and indoor sources increased during wildfire events. Infiltration factors decreased during periods of high outdoor PM 2.5 , such as during wildfires, reducing potential exposures from outdoor-origin particles but increasing potential exposures to indoor-origin particles. Time-of-day analysis reveals that episodic emission events are most frequent during mealtimes as well as on holidays (Thanksgiving and Christmas), indicating that cooking-related activities are a strong episodic emission source of indoor PM 2.5 in monitored residences.

54 ENVIRONMENTAL SCIENCES↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How will United States commercial building energy use be impacted by IPCC climate scenarios?

Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Studies and Energy Modeling for Evaluating Performance of Various Deep Wall Retrofits

The Pacific Northwest National Laboratory, Oak Ridge National Laboratory, and the University of Minnesota conducted a three-year, multipart study on residential retrofit wall assemblies. The project, which was funded by the U.S. Department of Energy’s Building Technology Office, aimed to compare a range of residential wall retrofit systems that prioritized affordability, durability, and energy savings potential. The research team identified, constructed, tested, simulated, and analyzed the feasibility and economics of 16 wall retrofit assemblies (14 test configurations and two baseline configurations) that can be applied to the exterior side of existing walls (either with or without the existing cladding). The 16 wall assemblies were installed in an in-situ laboratory environment, to evaluate the ease of construction and study the thermal and hygrothermal performance of the walls. This paper presents the methodology used to evaluate the thermal performance of the walls and discusses the energy modeling results of the study. The results from the experiments were used to calibrate a THERM model of each wall assembly, which was then applied to a whole building using the EnergyPlus 8.6 simulation engine. A residential prototype building was used to extrapolate whole-building energy savings in each U.S. climate zone. To capture the conditions of the largest number of homes in the United States, the most frequent building characteristics (e.g., attic insulation level, window specifications, foundation insulation, etc.) were extracted from ResStock data and applied to the prototype model. Results from the energy modeling showed that the climate zones with the highest potential for retrofit savings are those which are heating-dominated (i.e., Cold and Very Cold climate designations). In these climate zones, heating and cooling energy savings due to the wall retrofits alone ranged from 21.5% to 38.2%.

Nagda, Harshil↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Approach to Real-World Degradation of Backsheets

The objectives of this project are as follows: • The population behavior of fielded modules in various conditions of use • Predictions of materials in specific climatic zones • Understanding of a module’s local environment in the field on its degradation It aims to understand how and what backsheet materials of photovoltaic modules degrade in the real world field. • Field Survey Protocol This project is started from the protocol, because all the data, information, domain knowledge are from experience of the real world field surveys, which is based on the protocol. The Protocol is explored from the experience of the field survey observations. With the increasing of the field surveys, it is refined for three versions, which are Task 1.0 (Section 3.1), Task 6.0 (Section 3.6), Task 10.0 (Section 3.10) respectively. It includes a document and a training video, which is able to direct other teams to follow the same procedure with the sites surveyed during this project. The documents include the detailed information but is not limited to the terminology definition, instruments SOP, preparation items for the surveys, form for the data collections, the order of the information collection. The final version of the protocol can be found at Appendix A, see Section 5. Additional, It can also be found at Open Science Framework (OSF), see Section 3.18 for detail. • Written Waiver Request Before staring the field surveys, the request of the waiver for international surveys is completed, because the limitation of climate zone in the United States, see Appendix B in Section 6 for the request documents. Unfortunately, only 1 international site from Taiwan, China can be finished, due to the COVID-19. • Field Survey According to the protocol we built in Section 3.1, 3.6 and 3.10, 41 sites have been surveyed across seven different climate zones (Cfa, Csa, Csb, BSk, Dfa, Dfb, Am). A variety of materials, including Polyethylene Naphthalate (PEN), Polyethylene Terephthalate (PET), Polyvinyl Fluoride (PVF), Polyvinylidene Fluoride (PVDF), Acrylic PVDF, Fluoroethylene Vinyl Ether (FEVE), and Glass, were identified. These sites are located in various states including California, South Carolina, New Mexico, Maryland, Ohio, Tennessee, Florida, Massachusetts, Illinois, Minnesota, Oregon, Colorado, and Taiwan, Republic of China. The ages of the sites ranged from 2 - 38 years in service and the field size varied from 1 MW - 25 MW. All requirements for the modeling have been satisfied. Some observations like ’Edge Effect’ for the rows and Junction box heating will also be a useful knowledge to build the model. Section 3.7 provides detailed information on the sites visited during this reporting period.

14 SOLAR ENERGY↗

The role of air sealing while ground source heat pump system retrofits in the U.S. single-family houses

Widespread commercial adoption of ground source heat pumps (GSHP) is hindered by the relatively high initial cost associated with drilling boreholes in the ground to deploy ground heat exchangers. Reducing the energy demand of buildings has the potential to reduce the required borehole length and the associated drilling costs. In single-family residential buildings, air sealing can significantly lower heating energy usage, according to recent studies and reports. Thus, air sealing in conjunction with GSHP retrofits can lower the required GSHP system's capacity and borehole length to meet the thermal demands of the buildings. In order to understand the role of combining air sealing with GSHP retrofit quantitatively, the current study employs a whole building energy simulation tool integrated with an advanced design tool for the ground heat exchanger to determine changes in required GSHP capacity, total borehole length, and building energy consumption for with- and without-air sealing in single-family houses in 3 climate zones in the United States. The study considers one representative city for each climate zone, Phoenix, AZ for a hot climate, Seattle, WA for a moderate climate, and Minneapolis, MN for a cold climate. The results from this study show that reducing air infiltration from 0.8 ACH to the minimum ventilation requirement (0.35 ACH) can reduce borehole length requirement by up to 24% in Phoenix, 32% in Seattle, and 70% in Minneapolis. A similar magnitude of reduction can be seen for GSHP capacity and total building energy usage as well.

Prem Anand Jayaprabha, Jyothis Anand↗

Mitigating Moisture with High-R Walls

Energy-efficient building enclosures are key to decreasing energy load demand and enabling advanced space-conditioning systems for high-performance homes. One efficient enclosure design solution is high-R walls, which feature increased insulation levels as an effective solution for reducing air leakage and permeance of material layers. To increase builder confidence and encourage greater market adoption of high-R walls, Home Innovation Research Labs sought to demonstrate the long-term moisture performance of several high-R wall configurations in cold climate zones. The team monitored 22 newly constructed, occupied homes located throughout climate zones 4–7, where a substantial vapor drive to the exterior is present during the winter.

buildings↗

Low-temperature solar thermal-power systems for residential electricity supply under various seasonal and climate conditions

In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.

14 SOLAR ENERGY↗

End-Use Savings Shapes: Measure Documentation: Add Exhaust Air Heat/Energy Recovery

This documentation focuses on a single end-use savings shape measure—Add Exhaust Air Heat/Energy Recovery. This measure adds exhaust air energy recovery or heat recovery to existing air handling units (AHU) with outdoor air. Systems that already have energy/heat recovery are not modified. Furthermore, food service building types are also not modified by this measure due to the added complication of integrating cooking hood exhaust that could cause heat exchanger fouling from kitchen exhaust. In total, this measure is applicable airloops serving ~70% of the floor area in ComStock. In practice, energy/heat recovery systems are retrofitted to existing air delivery systems either as separate systems that provide outdoor air to the AHUs or are directly integrated to an AHU; the modeling approach used in this study is agnostic of the energy recovery type and simply accounts recovery effectiveness, added static pressure, and other controls which are described further in this document. Energy recovery with sensible and latent exchange gets added in humid climate zones, while heat recovery with sensible-only exchange gets added in drier climate zones. Energy recovery is modeled as a fixed membrane plate counterflow heat exchanger, while heat recovery is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and electric resistance preheat coil for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential energy savings benefits and limitations of radiative cooling coatings for U.S. residential buildings

We report radiative coatings are a promising strategy to implement passive cooling that provides an eco-friendly pathway to achieve energy efficiency in buildings. This study investigates the benefits and limitations of implementing radiative coatings on the building envelope, particularly the roof, of residential buildings in the United States. The analysis compares the performance of an ideal radiative coating with broadband surface properties to a realistic radiative coating with diffuse and semitransparent properties. To enhance the net energy efficiency of buildings, we carried out a comprehensive parametric analysis comprising key radiation surface properties to maximize cooling energy savings while minimizing heating energy penalties. A countrywide assessment for 68 locations across the United States showed that net energy savings are a strong function of the climatic and atmospheric conditions. Broadly, southern locations showed high overall energy savings whereas northern locations exhibited high overall energy penalties. Locations in International Energy Conservation Code (IECC) climate zones 1A, 2A, and 2B showed a net annual energy savings above 5%, whereas locations in IECC climate zones 5B, 6B, and 7 showed a net annual energy penalty greater than 3%. The hot and dry climate of Phoenix, Arizona, showed the highest overall energy savings of 426 kWh (6.2%). Additionally, the mathematical correlation reveals that the net energy savings of a location is positive only when its average cooling degree days is greater than 5.5 or its average heating degree days is less than 10.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ship-based measurements of ice nuclei concentrations over the Arctic, Atlantic, Pacific and Southern oceans

Ambient concentrations of ice-forming particles measured during ship expeditions are collected and summarised with the aim of determining the spatial distribution and variability in ice nuclei in oceanic regions. The presented data from literature and previously unpublished data from over 23 months of ship-based measurements stretch from the Arctic to the Southern Ocean and include a circumnavigation of Antarctica. In comparison to continental observations, ship-based measurements of ambient ice nuclei show 1 to 2 orders of magnitude lower mean concentrations. To quantify the geographical variability in oceanic areas, the concentration range of potential ice nuclei in different climate zones is analysed by meridionally dividing the expedition tracks into tropical, temperate and polar climate zones. We find that concentrations of ice nuclei in these meridional zones follow temperature spectra with similar slopes but vary in absolute concentration. Typically, the frequency with which specific concentrations of ice nuclei are observed at a certain temperature follows a log-normal distribution. A consequence of the log-normal distribution is that the mean concentration is higher than the most frequently measured concentration. Finally, the potential contribution of ship exhaust to the measured ice nuclei concentration on board research vessels is analysed as function of temperature. We find a sharp onset of the influence at approximately -36 °C but none at warmer temperatures that could bias ship-based measurements.

54 ENVIRONMENTAL SCIENCES↗

Influence of urban extent discrepancy on the estimation of surface urban heat island intensity: A global-scale assessment in 892 cities

The estimation of surface urban heat island intensity (SUHII) is crucial for studying the urban thermal environment, which is influenced not only by the commonly known definition of rural reference but also by the delineation of urban extent. Existing studies relies on various urban extent products defined in different ways, and the influence of urban extent discrepancy (UED) on SUHII estimates still remains unclear. In this study, we collected five open-source global urban extent products (GUEPs) for the year 2015 and corresponding daily land surface temperature (LST) observations (MYD11A1). Based on these products, we quantified the UED-induced uncertainty in SUHII estimates by comparing absolute difference (ΔSUHII AD ) and relative difference (ΔSUHII RD ) in SUHII among GUEPs across 892 global cities. Additionally, we introduced an ISF-constrained (ISF–C) method to reduce SUHII differences among GUEPs by constraining the impervious surface fraction (ISF) within urban and rural extents. The results show that urban extents delineated by different GUEPs are not consistent, leading to their difference in ISF as well as LST, which in turn causes uncertainties in the estimated SUHII. On average for global cities, the annual daytime and nighttime ΔSUHII AD are 0.46 ± 0.02 °C (mean ± 95% confidence interval) and 0.24 ± 0.01 °C, with corresponding ΔSUHII RD of 42.0 ± 2.7% and 35.2 ± 2.3%, respectively. The UED-induced uncertainty in SUHII estimates varies among climate zones, and the annual daytime ΔSUHII RD averaged for cities located in the arid zone reaches up to 60.8 ± 6.6%, which is nearly twice as high as that in other climate zones. More importantly, both ΔSUHII AD and ΔSUHII RD show lower values when using the ISF-C method, implying the effectiveness of this method. This study highlights the non-negligible impact of UED on the estimation of SUHII, which requires more attention due to the inconsistency of urban extents among current products.

54 ENVIRONMENTAL SCIENCES↗

Expanded Energy Credits in Energy Codes (Technical Brief)

This technical brief provides additional energy efficiency measures that go beyond the current prescriptive commercial energy codes. It demonstrates relative savings for multiple measures and shows a base cost effective package by building type and climate zone. An advanced savings package is also shown. Potential building savings for the base package for different building types across climate zones range from 3.9% to 22% of building energy cost, while the advanced package building savings range from 8.4% to 44%. In addition to measure descriptions, this technical brief includes code language that can be adopted by local jurisdictions to implement these measures for new buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Alaska's Rural Building Stock: a Validation Study Using ResStock and Field Data

The availability of accurate national data on demographics, building stock, and energy use is vital for modeling residential buildings and evaluating decarbonization strategies. However, rural and Indigenous populations, including those in rural Alaska, are typically underrepresented in these datasets. These communities face unique challenges due to their remote locations, severe weather conditions, and limited access to resources, resulting in high energy burden. This report examines how rural Alaskan communities are underrepresented in the ResStock housing model and highlights the need for improved data to address their unique housing and energy challenges. Thus, this report examines the representation of rural Alaskan communities within the national housing stock model, ResStock. A validation study was conducted, considering ResStock, Field Data and Aerial and 3D-view data collection (A3DDC) datasets. The validation process started by using the down selecting approach on the ResStock building stock dataset. For the purpose of this study, only the rural Alaska Boroughs and Census areas located in ASHRAE IECC Climate Zone 8 were considered to ensure a more accurate and fair comparison with the field data, which was collected in rural areas located in climate zone 8, specifically within the Nome Census area. While ResStock may accurately represent several characteristics of the building stock for rural Alaska, some differences between modeled, field data, and aerial and 3D-view data collection datasets were identified. The following building characteristics have a high impact on modeled energy consumption and demonstrated large differences: Revisit heating setpoints and consider a substantially higher setpoint distribution, it could potentially address "missing loads" if this is the case. Develop and include Toyo heating in future modeling for ResStock and EnergyPlus. Remove natural gas as a water heater fuel type outside of North Slope County. Foundation type updated to have more crawlspaces rather than basements. Infiltration rates need reexamination for a larger distribution toward higher infiltration rates. Include more vinyl and less brick in exterior wall type and revise wall color for greater proportion of light rather than dark color. Roof material revised from majority shingles to majority metal. Update number of occupants to higher number of occupant count. Building orientation represents a higher proportion of south facing buildings rather than relatively equal. The findings suggest that updating ResStock's probability logic could better represent rural Alaskan buildings. ResStock can be utilized to identify the best upgrades or energy efficiency and energy efficiency improvements, helping community leaders in making more informed decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-term carbon intensity reduction potential of K-12 school buildings in the United States

School buildings have a great potential for carbon emission reduction since their annual emission is about 72 million metric tons. Currently, more than 30% of school buildings were built before 1960 and are underperforming. To effectively reduce carbon emissions via school building retrofits, it is critical for policymakers to understand the carbon intensity reduction potential of retrofitting school buildings in different regions. Hence, this study develops a method to comprehensively assess the long-term carbon intensity reduction potential of aggregated commercial buildings on a county-by-county basis in the continental U.S. We apply this method to the K-12 school buildings including primary and secondary school buildings. Here, this paper predicts the carbon intensity reduction potential of K-12 school buildings with eight building retrofit measures from 2022 to 2050 in the continental U.S. The results reveal several interesting findings: (1) In the approximately 3,000 counties of the U.S. from 2022 to 2050, the carbon intensity reduction potential of retrofitting K-12 school buildings in each county ranges from 0.41 kg/m 2 to 40.00 kg/m 2 . (2) Even in the same climate zone, the trends of carbon intensity reduction potential from 2022 to 2050 are different depending on their electricity sources. For example, in a hot and humid climate zone, the carbon intensity reduction potential in Florida will decrease from 2044 to 2048. However, in Mississippi, the carbon intensity reduction potential from 2044 to 2046 will increase due to the termination of the nuclear energy usage. (3) Generally, reducing lighting power density leads to more carbon intensity reduction in most states, but it might not be applicable for states with high clean energy penetration, such as Washington.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Growth modeling to evaluate alternative cultivation strategies to enhance national microalgal biomass production

In this paper, we present a model-based assessment of alternative cultivation strategies on algal biomass production within the conterminous United States. Our assessment focuses on two basic cultivation strategies: 1) seasonal rotation of three representative freshwater algal strains that are well suited for warm weather, cold weather, and all-season diverse weather conditions, respectively; and 2) variation between three open pond water depths (15cm, 20cm, and 25cm). The enhanced Biomass Assessment Tool (BAT) is applied on a site-specific, hourly basis at 5,832 North American Land Data Assimilation System Phase 2 1/8° meteorological model grid cells over a 30-year period (1980-2009) to evaluate the operational strategies. Recognizing that resource management decisions may also consider scales beyond the individual site, we also conduct a regional assessment of focused on 7 representative climate zones in the conterminous United States. Results demonstrate that the spatial variability of algal productivity is largely affected by the strain-specific growth response to light and temperature that vary significantly by climate zone and latitude. Therefore, with a limited set of alternative cultivation strategies, the BAT identified the best performing combination of cultivation strategies on a site-specific basis that considerably enhances national annual biomass productivity. Specifically, the appropriate choice of seasonal strain rotation is able to significantly dampen climate-driven seasonal and spatial variability.

59 BASIC BIOLOGICAL SCIENCES↗

Methodology to evaluate design modifications intended to eliminate frosting and high discharge temperatures in air-source heat pumps (ASHPs) in cold climates

Air-source heat pumps (ASHPs) operating in cold climates experience problems with frosting and high refrigerant temperatures. These problems increase energy consumption, and their severity depends on the climatic conditions. In the present paper, a methodology for identifying the prevailing problem between frosting and high discharge temperatures is presented. Three performance indices, the frosting index (FI), the discharge index (DI), and the total loss index (TLI), are proposed to quantify the impacts of frosting and high discharge temperatures on the annual performance of ASHPs in different climatic conditions. The FI and DI show which problem (frosting or high discharge temperature) dominates, and the TLI indicates the combined effect of frosting and high discharge temperatures on the performance of an ASHP. A thermodynamic model of an ASHP coupled with the TRNSYS building simulation tool is used to estimate the performance of an ASHP and the proposed loss indices to estimate the impact of both frosting and high discharge temperatures for 45 cities in Canada. The results can be extended to other parts of the world that experience similar climatic conditions The results reveal that in cities in ASHRAE climatic zones 5 and 6 (classified as cold regions) where the ambient air temperatures are predominantly between -15 °C to 6 °C, ASHPs are heavily impacted by frosting. The problem of high discharge temperatures in ASHPs is predominant in cities in climate zones 7 and 8 (classified as very cold and subarctic regions) where the temperatures are frequently below -20 °C in winter. Among the cities considered, St. John, NL has the highest fraction of heating hours experiencing frosting (90 %), where the annual increase in energy consumption due to frosting is 13.5 % of the annual heating energy consumption. The highest annual increase in energy consumption due to high discharge temperatures is in Isachsen, NU (zone 8), where the increase is 30 % of the annual heating energy consumption. Based on the proposed indices, another index called the performance gain index (PGI) is created, which can be used as a first step to assess the energy-saving potential of design modifications applied to ASHPs to solve the problems of frosting and high discharge temperatures. The PGI will aid in developing climate specific ASHPs. One possible design modification is the use of a two-stage ASHP with an economizer. It is observed that the two-stage ASHP with economizer can mitigate high discharge temperatures and improve performance in very cold and subarctic regions (zones 7 and 8). However, it is not as beneficial in zones 5 and 6, where the impact of high discharge temperatures on performance is minimal and frosting dominates. Finally, a case study, using the PGI to evaluate the economic and environmental effectiveness of a two-stage ASHP with economizer is presented for the city of Saskatoon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗