Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Climate Zones”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Model America - data and models of every U.S. building

The 5-year goal of the 'Model America' concept was to generate a model of every building in the United States. This data repository delivers on that goal. Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM). There were 125,714,640 buildings detected in the United States and this dataset contains 122,930,327 (97.8%) buildings which resulted in a successful simulation. Future, annual updates have been proposed that may include additional buildings, data improvements, or other algorithmic enhancements. This dataset of 122.9 million buildings includes: Models (state_county.zip) - OpenStudio (v3.1.0) and EnergyPlus (v9.4) building energy models. Please note that the download requires the free Globus Connect Personal (https://www.globus.org/globus-connect-personal); Each model has approximately 3,000 building input descriptors that can be extracted. Please see the EnergyPlus(v9.4) 2,784-page Input/Output Reference Guide (https://energyplus.net/sites/all/modules/custom/nrel_custom/pdfs/pdfs_v9.4.0/InputOutputReference.pdf) for everything that can be retrieved or simulated from these models. These models were derived from the following metadata, which is not included in this dataset: 1. ID - unique building ID 2. County - county name 3. State - state name 4. CZ - ASHRAE Climate Zone designation 5. Clim_Zone - text label of climate zone 6. est_year - estimated year of construction 7. est_commercial - estimated building type (0=residential, 1=commercial) 8. Centroid - building center location in latitude/longitude (from Footprint2D) 9. Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) 10. Height - building height (meters) 11. Area2D - footprint area (ft2) 12. BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards 13. WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) 14. NumFloors - number of floors (above-grade) 15. Area - estimate of total conditioned floor area (ft2) 16. Standard - building vintage. These models are made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD), U.S. Dept. of Energy's (DOE) Building Technologies Office (BTO), Office of Electricity (OE), Biological and Environmental Research (BER), and National Nuclear Security Administration (NNSA). This research used resources of the Argonne Leadership Computing Facility, which is a DOE Office of Science User Facility supported under Contract DE-AC02-06CH11357. Please cite as: New, Joshua R., Adams, Mark, Bass, Brett, Berres, Anne, and Clinton, Nicholas (2021). 'Model America - data and models of every U.S. building. [Data set].' Constellation, doi.ccs.ornl.gov/ui/doi/339, April 14, 2021

24 POWER TRANSMISSION AND DISTRIBUTION↗

Water desalination through the dewpoint evaporative system

This paper presents the first numerical analysis of a novel Dew Point Desalination unit (DPD), which utilizes the phenomenon of the evaporative cooling process to minimize energy consumption. The proposed solution is based on a modular structure, which allows it to obtain any required water production capacity. The analyses for various operational parameters and various climatic conditions are based on the numerical simulations conducted using a validated mathematical model. The system performance was described with different factors, including specific energy consumption (SEC) and daily water production rate respected to 1 m^3*s^-1 of passing air stream (DWP). It is shown that the DPD system can operate in almost every climate zone, and the desalinated water production consumes less than 1.5 kWh*m^-3 of electric energy It is noted the best performance of the DPD system is achieved in the semi-arid, desert and subtropical climate zones. In these climate zones, the 2-stage DPD system allows the production of desalinated water with an electric energy consumption SEC lower than 0.5 kWh*m^-3. The additional benefit of the DPD system is its modularity. The presented DPD system stands as a module, that can be multiplied as needed to achieve the desired size of the desalination plant.

Desalination↗

Linear and Nonlinear Trend Analyzes in Global Satellite‐Based Precipitation, 1998–2017

Precipitation varies spatio‐temporally in amount, intensity, and frequency. Although, much research has been conducted on analyzing precipitation patterns and variation at the global scale, trend types have still not received much attention. This study developed a new polynomial‐based model for detecting nonlinear and linear trends in a satellite precipitation product (TRMM 3B43) for the 1998–2017 period at a near‐global scale. We used an automated trend classification method that detects significant trends and classifies them into linear and nonlinear (cubic, quadratic, and concealed) trend types in satellite‐based precipitation at near‐global, continental, and climate zone scales. We found that 12.3% of pixel‐based precipitation time series across the globe have significant trend at 0.05 significance level (50% positive and 50% negative trends). In all continents except Asia, decreasing trends were found to cover larger areas than corresponding increasing trends. Regarding climate zone and precipitation trend change, our results indicate that a linear trend is dominant in the warm temperate (77.7%) and equatorial climates (80.4%) while the least linear change was detected in the polar climate (68.9%). The combined results of continental and climate zone scales indicate significant increasing trends in Asia and arid climate over the last 20 yr. Furthermore, positive trends were found to be more significant at the continental scale, particularly, in Asia relative to the climate zone scale. Linear change in precipitation (80%) was the most dominant trend observed as opposed to nonlinear (quadratic [11%] and cubic [9%]) trend types at the global scale.

Majid Kazemzadeh↗

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An interactive method for digitizing zone maps

A method is presented for digitizing maps that consist of zones, such as contour or climatic zone maps. A color-coded map is prepared by any convenient process. The map is then read into memory of an Image 100 computer by means of its table scanner, using colored filters. Zones are separated and stored in themes, using standard classification procedures. Thematic data are written on magnetic tape and these data, appropriately coded, are combined to make a digitized image on tape. Step-by-step procedures are given for digitization of crop moisture index maps with this procedure. In addition, a complete example of the digitization of a climatic zone map is given.

Giddings, L. E.↗

Detecting the Greatest Changes in Global Satellite-Based Precipitation Observations

In recent years, the analysis of abrupt and non-abrupt changes in precipitation has received much attention due to the importance of climate change-related issues (e.g., extreme climate events). In this study, we used a novel segmentation algorithm, DBEST (Detecting Breakpoints and Estimating Segments in Trend), to analyze the greatest changes in precipitation using a monthly pixel-based satellite precipitation dataset (TRMM 3B43) at three different scales: (i) global, (ii) continental, and (iii) climate zone, during the 1998–2019 period. We found significant breakpoints, 14.1%, both in the form of abrupt and non-abrupt changes, in the global scale precipitation at the 0.05 significance level. Most of the abrupt changes were observed near the Equator in the Pacific Ocean and Asian continent, relative to the rest of the globe. Most detected breakpoints occurred during the 1998–1999 and 2009–2011 periods on the global scale. The average precipitation change for the detected breakpoint was ±100 mm, with some regions reaching ±3000 mm. For instance, most portions of northern Africa and Asia experienced major changes of approximately +100 mm. In contrast, most of the South Pacific and South Atlantic Ocean experienced changes of −100 mm during the studied period. Our findings indicated that the larger areas of Africa (23.9%), Asia (22.9%), and Australia (15.4%) experienced significant precipitation breakpoints compared to North America (11.6%), South America (9.3%), Europe (8.3%), and Oceania (9.6%). Furthermore, we found that the majority of detected significant breakpoints occurred in the arid (31.6%) and polar (24.1%) climate zones, while the least significant breakpoints were found for snow-covered (11.5%), equatorial (7.5%), and warm temperate (7.7%) climate zones. Positive breakpoints’ temporal coverage in the arid (54.0%) and equatorial (51.9%) climates were more than those in other climates zones. Here, the findings indicated that large areas of Africa and Asia experienced significant changes in precipitation (−250 to +250 mm). Compared to the average state (trend during a specific period), the greatest changes in precipitation were more abrupt and unpredictable, which might impose a severe threat to the ecology, environment, and natural resources.

Breakpoint↗

Characterizing photovoltaic backsheet adhesion degradation using the wedge and single cantilever beam tests, Part I: Field Modules

Photovoltaic backsheets are exposed to harsh outdoor weathering conditions throughout their service lives that can compromise their protective function, through adhesive debonding between their constituent layers and between the backsheet and the module. We report a large-scale study on adhesive degradation was conducted on 37 field-exposed modules, that spanned 19 different module manufacturers, that were deployed among six Köppen–Geiger climatic zones, and that were fielded between 0 and 28 years. Six outer layer polymer classes were identified among the backsheets: polyamide (PA), polyethylene terephthalate (PET), polyvinyl fluoride (PVF), polyvinylidene fluoride (PVDF), fluoroethylene vinyl ether copolymer (FEVE), and tetrafluoroethylene hexafluoropropylene vinylidene fluoride copolymer (THV). Two adhesion tests were used to measure the adhesive strength: the wedge test and the width-tapered single-cantilever beam (SCB) test. Adhesion energies were compared across exposure time and Köppen–Geiger climatic zone. Many of the PET-, PVF-, and PVDF-based backsheets experienced degradation of the adhesive layer between the backsheet outer and core layers. A consistent trend of decreasing adhesion energy with exposure time was observed in five out of the six backsheet types. Trends among adhesion energy and climatic zone, while expected, were not observed, possibly due to broad ranges in temperature, humidity, and precipitation defining Köppen–Geiger climatic zones. The cantilever beam measurements produced an upper cutoff of approximately 100 J/m 2 , above which no modules exhibited field delamination. The results are part of a two-part study quantifying adhesion in both field-weathered and indoor-exposed PV backsheets.

14 SOLAR ENERGY↗

Assessing residential PM 2.5 concentrations and infiltration factors with high spatiotemporal resolution using crowdsourced sensors

Building conditions, outdoor climate, and human behavior influence residential concentrations of fine particulate matter (PM 2.5 ). To study PM 2.5 spatiotemporal variability in residences, we acquired paired indoor and outdoor PM 2.5 measurements at 3,977 residences across the United States totaling >10,000 monitor-years of time-resolved data (10-min resolution) from the PurpleAir network. Time-series analysis and statistical modeling apportioned residential PM 2.5 concentrations to outdoor sources (median residential contribution = 52% of total, coefficient of variation = 69%), episodic indoor emission events such as cooking (28%, CV = 210%) and persistent indoor sources (20%, CV = 112%). Residences in the temperate marine climate zone experienced higher infiltration factors, consistent with expectations for more time with open windows in milder climates. Likewise, for all climate zones, infiltration factors were highest in summer and lowest in winter, decreasing by approximately half in most climate zones. Large outdoor–indoor temperature differences were associated with lower infiltration factors, suggesting particle losses from active filtration occurred during heating and cooling. Absolute contributions from both outdoor and indoor sources increased during wildfire events. Infiltration factors decreased during periods of high outdoor PM 2.5 , such as during wildfires, reducing potential exposures from outdoor-origin particles but increasing potential exposures to indoor-origin particles. Time-of-day analysis reveals that episodic emission events are most frequent during mealtimes as well as on holidays (Thanksgiving and Christmas), indicating that cooking-related activities are a strong episodic emission source of indoor PM 2.5 in monitored residences.

54 ENVIRONMENTAL SCIENCES↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Olivine Dissolution and Formation of Secondary phases in Ultramafic Soils

Introduction: Olivine has been proposed as an indicator for the duration of water-rock interaction within Martian rocks and sediments [1-3]. The use of olivine as a mineralogical indicator for past aqueous alteration on Mars requires interpretation of a complex combination of factors including pH, temperature, and composition [5,6]. Here, we examine the persistence of natural olivine within terrestrial ultramafic soils (Fe/Mg-rich, Al-poor) developing under different climatic conditions and the incipient dissolution of emplaced forsterite (Fo) and fayalite (Fa) surfaces to investigate environmental effects on incipient olivine dissolution, olivine persistence in soils, and formation of secondary phases. Methods: Field Sites. We examined olivine weathering and secondary material formation in ultramafic soils at 6 sites in the Klamath Mountains (KM) of northern California with a mean annual temperature of ~12.8℃ and precipitation of ~55.7-95.4 cm/year [7], and soil pH of ~6.5-7.3; 4 sites in the Tablelands (TB) of Newfoundland, Canada with a mean annual temperature of <3.9℃ and precipitation of ~120.0 cm/year [8], and soil pH of ~7.7; and at 3 sites at Pickhandle Gulch (PG), Nevada with a mean annual temperature of ~14.4℃ and precipitation of ~14.1 cm/year [7], and soil pH of ~8.5. Sampling sites span an age range of ~12.1-50+ kya in the Klamath Mountains [9,10] and ~13-30 kya in the Tablelands [11]. Pickhandle Gulch sites are undated. Parent Material and Soil Analyses. Polished thin sections of bulk soil prepared by Wagner Petrographic, Inc were carbon-coated and analyzed on a JEOL 2100 SEM in back-scattered electron mode in the EMIL lab at UNLV and at the 13-ID-E synchrotron beamline at Argonne National Laboratory using µXRF, µXRD, and XAS. Soil and parent material samples were powdered in a Fritsch pulverisette and analyzed by XRD and soil by VNIR. Soil preparation is further described in [12]. Disk Preparation, Burial, and Collection. Fo disks were cut from a column prepared via hot-pressing and Fa disks by sintering synthetic fayalite powder, see [13] for detail. Disks were polished to a 0.25-micron level with diamond grit. Disks were buried in 3 KM soils, 4 TB soils, and 3 PG soils, collected after exactly 365 days, and washed gently with 100% reagent grade ethanol to remove potential adhered soil material. Weathered disks and soil samples were stored in a -20℃ freezer until analysis. Unaltered control disks prepared identically to the buried disks were stored at -20℃ for the duration of the experiment. Disk Analyses. One Fo and Fa disk from each climate zone was analyzed on a variable pressure Zeiss Supra 40VP SEM at Northern Arizona University. A separate Fo and Fa disk from each climate zone was analyzed by XPS using a Physical Electronics VersaProbe II at the Penn State Univ. Materials Characterization Lab after a Na-dodecyl sulfate wash and ozonation to remove carbon contamination as in [14]. VNIR measurements were conducted at Johnson Space Center using an ASD FieldSpec3 under ambient lab conditions on a separate Fo and Fa disk from each climate zone. One separate Fo and Fa control sample was analyzed for each technique for comparison with weathered samples. XPS uncertainty was determined from 5 repeat measurements on controls. Results: Bedrock and Soil Results Olivine is present in the parent material in the KM and TB. Olivine is found in ~12.1 ka KM soils but is absent from all older soils, while persisting into the oldest (>20 ka) TB soil (Figure 1). In both locations, olivine is found as cores surrounded by a serpentine rind (Figure 2). VNIR spectra from the analyzed soils possess strong OH-associated spectral features at ~2.33 µm indicating the presence of Mg-rich phyllosilicates as well as ferric-oxide features at ~0.92 µm in the KM (Figure 3). Primary crystalline silicate grains mostly incorporate Fe2+, while poorly crystalline weathering rinds are best fit by ferric oxide XAS standards (Figure 4). µXRF also shows that Fe and Ni concentrate in weathering rinds and Cr remains within interior silicate grains (Figure 4). Buried Sample Results All Fo surfaces exhibited formation of dissolution features including shallow pitting not observed on controls. Dissolution features were most visually widespread on the KM disk (Figure 5). Leaching of Mg from KM and TB Fo disks was evident from <1.6 Mg/Si ratios measured by XPS (Figure 6). Fe-rich precipitates in SEM (Figure 5) and Fe presence in XPS scans (Figure 6) indicate Fe deposition onto KM and TB Fo disk surfaces. The appearance of a spectral feature at 0.55 µm in the VNIR spectra from the TB Fo suggests this Fe is ferric (Figure 7). The PG Fo appears least altered, with minimal formation of dissolution features in SEM (Figure 5), a Mg/Si ratio inconsistent with leaching (~2) (Figure 6), and VNIR spectra almost identical to the control sample. Analysis of Fa surfaces is ongoing. The higher temperatures and more acidic pH in the KM soils likely drive the faster dissolution of the Fo disks described above. While the TB soils experience greater precipitation than in the KM, the cooler temperatures and more basic soil pH facilitate observable but more limited alteration. The dry climate and basic soil pH at PG lead to minimal dissolution of the PG disk surfaces.

A D Feldman↗

How will United States commercial building energy use be impacted by IPCC climate scenarios?

Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Studies and Energy Modeling for Evaluating Performance of Various Deep Wall Retrofits

The Pacific Northwest National Laboratory, Oak Ridge National Laboratory, and the University of Minnesota conducted a three-year, multipart study on residential retrofit wall assemblies. The project, which was funded by the U.S. Department of Energy’s Building Technology Office, aimed to compare a range of residential wall retrofit systems that prioritized affordability, durability, and energy savings potential. The research team identified, constructed, tested, simulated, and analyzed the feasibility and economics of 16 wall retrofit assemblies (14 test configurations and two baseline configurations) that can be applied to the exterior side of existing walls (either with or without the existing cladding). The 16 wall assemblies were installed in an in-situ laboratory environment, to evaluate the ease of construction and study the thermal and hygrothermal performance of the walls. This paper presents the methodology used to evaluate the thermal performance of the walls and discusses the energy modeling results of the study. The results from the experiments were used to calibrate a THERM model of each wall assembly, which was then applied to a whole building using the EnergyPlus 8.6 simulation engine. A residential prototype building was used to extrapolate whole-building energy savings in each U.S. climate zone. To capture the conditions of the largest number of homes in the United States, the most frequent building characteristics (e.g., attic insulation level, window specifications, foundation insulation, etc.) were extracted from ResStock data and applied to the prototype model. Results from the energy modeling showed that the climate zones with the highest potential for retrofit savings are those which are heating-dominated (i.e., Cold and Very Cold climate designations). In these climate zones, heating and cooling energy savings due to the wall retrofits alone ranged from 21.5% to 38.2%.

Nagda, Harshil↗

Delineation of cold-prone areas using nighttime SMS/GOES thermal data Effects of soils and water

Infrared digital data from geostationary satellites were used to demonstrate the usefulness of remotely sensed surface temperature data to delineate microscale and mesoscale climates. Nocturnal winter data (December-February) from 1976-77 to 1978-79 over Florida revealed noticeable contrasts in surface temperature patterns. Colder areas were associated with low soil moisture content in the upper layers of excessively drained and well drained sandy soils, whereas warmer areas were associated with bodies of water, wetlands, or poorly drained soils. An unexpected surface temperature pattern for one night where the north-central Florida climatic zone was colder than the north Florida climatic zone was found to be caused by differences in antecedent frontal rainfall. Differences in surface radiant energy fluxes over these two areas at 0200 EST 20 December 1977, based on average satellite-sensed surface temperatures, were compared with differences in soil heat fluxes that were computed from 1.5 m climatological temperatures and soil thermal properties by use of a simplified surface energy balance equation.

Chen, E.↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Approach to Real-World Degradation of Backsheets

The objectives of this project are as follows: • The population behavior of fielded modules in various conditions of use • Predictions of materials in specific climatic zones • Understanding of a module’s local environment in the field on its degradation It aims to understand how and what backsheet materials of photovoltaic modules degrade in the real world field. • Field Survey Protocol This project is started from the protocol, because all the data, information, domain knowledge are from experience of the real world field surveys, which is based on the protocol. The Protocol is explored from the experience of the field survey observations. With the increasing of the field surveys, it is refined for three versions, which are Task 1.0 (Section 3.1), Task 6.0 (Section 3.6), Task 10.0 (Section 3.10) respectively. It includes a document and a training video, which is able to direct other teams to follow the same procedure with the sites surveyed during this project. The documents include the detailed information but is not limited to the terminology definition, instruments SOP, preparation items for the surveys, form for the data collections, the order of the information collection. The final version of the protocol can be found at Appendix A, see Section 5. Additional, It can also be found at Open Science Framework (OSF), see Section 3.18 for detail. • Written Waiver Request Before staring the field surveys, the request of the waiver for international surveys is completed, because the limitation of climate zone in the United States, see Appendix B in Section 6 for the request documents. Unfortunately, only 1 international site from Taiwan, China can be finished, due to the COVID-19. • Field Survey According to the protocol we built in Section 3.1, 3.6 and 3.10, 41 sites have been surveyed across seven different climate zones (Cfa, Csa, Csb, BSk, Dfa, Dfb, Am). A variety of materials, including Polyethylene Naphthalate (PEN), Polyethylene Terephthalate (PET), Polyvinyl Fluoride (PVF), Polyvinylidene Fluoride (PVDF), Acrylic PVDF, Fluoroethylene Vinyl Ether (FEVE), and Glass, were identified. These sites are located in various states including California, South Carolina, New Mexico, Maryland, Ohio, Tennessee, Florida, Massachusetts, Illinois, Minnesota, Oregon, Colorado, and Taiwan, Republic of China. The ages of the sites ranged from 2 - 38 years in service and the field size varied from 1 MW - 25 MW. All requirements for the modeling have been satisfied. Some observations like ’Edge Effect’ for the rows and Junction box heating will also be a useful knowledge to build the model. Section 3.7 provides detailed information on the sites visited during this reporting period.

14 SOLAR ENERGY↗

The role of air sealing while ground source heat pump system retrofits in the U.S. single-family houses

Widespread commercial adoption of ground source heat pumps (GSHP) is hindered by the relatively high initial cost associated with drilling boreholes in the ground to deploy ground heat exchangers. Reducing the energy demand of buildings has the potential to reduce the required borehole length and the associated drilling costs. In single-family residential buildings, air sealing can significantly lower heating energy usage, according to recent studies and reports. Thus, air sealing in conjunction with GSHP retrofits can lower the required GSHP system's capacity and borehole length to meet the thermal demands of the buildings. In order to understand the role of combining air sealing with GSHP retrofit quantitatively, the current study employs a whole building energy simulation tool integrated with an advanced design tool for the ground heat exchanger to determine changes in required GSHP capacity, total borehole length, and building energy consumption for with- and without-air sealing in single-family houses in 3 climate zones in the United States. The study considers one representative city for each climate zone, Phoenix, AZ for a hot climate, Seattle, WA for a moderate climate, and Minneapolis, MN for a cold climate. The results from this study show that reducing air infiltration from 0.8 ACH to the minimum ventilation requirement (0.35 ACH) can reduce borehole length requirement by up to 24% in Phoenix, 32% in Seattle, and 70% in Minneapolis. A similar magnitude of reduction can be seen for GSHP capacity and total building energy usage as well.

Prem Anand Jayaprabha, Jyothis Anand↗

Mitigating Moisture with High-R Walls

Energy-efficient building enclosures are key to decreasing energy load demand and enabling advanced space-conditioning systems for high-performance homes. One efficient enclosure design solution is high-R walls, which feature increased insulation levels as an effective solution for reducing air leakage and permeance of material layers. To increase builder confidence and encourage greater market adoption of high-R walls, Home Innovation Research Labs sought to demonstrate the long-term moisture performance of several high-R wall configurations in cold climate zones. The team monitored 22 newly constructed, occupied homes located throughout climate zones 4–7, where a substantial vapor drive to the exterior is present during the winter.

buildings↗