Summary report on the Nimbus II satellite.
Nimbus 2 meteorological satellite observations, discussing circulation associated with synoptic scale systems obtained by correlating water vapor and carbon dioxide pictures
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Nimbus 2 meteorological satellite observations, discussing circulation associated with synoptic scale systems obtained by correlating water vapor and carbon dioxide pictures
The vertical distribution of local and remote sources of water for precipitation and total column water over the United States are evaluated in a general circulation model simulation. The Goddard Earth Observing System (GEOS) general circulation model (GCM) includes passive constituent tracers to determine the geographical sources of the water in the column. Results show that the local percentage of precipitable water and local percentage of precipitation can be very different. The transport of water vapor from remote oceanic sources at mid and upper levels is important to the total water in the column over the central United States, while the access of locally evaporated water in convective precipitation processes is important to the local precipitation ratio. This result resembles the conceptual formulation of the convective parameterization. However, the formulations of simple models of precipitation recycling include the assumption that the ratio of the local water in the column is equal to the ratio of the local precipitation. The present results demonstrate the uncertainty in that assumption, as locally evaporated water is more concentrated near the surface.
Speleothem records from the South Asian summer monsoon (SASM) region display variability in the ratio of O-18 and O-16 (δ O-18) in calcium carbonate at orbital frequencies. The dominant mode of variability in many of these records reflects cycles of precession. There are several potential explanations for why SASM speleothem records show a strong precession signal, including changes in temperature, precipitation, and circulation. Here we use an Earth system model with water isotope tracers and water-tagging capability to deconstruct the precession signal found in SASM speleothem records. Our results show that cycles of precession-eccentricity produce changes in SASM intensity that correlate with local temperature, precipitation, and δ O-18. However, neither the amount effect nor temperature differences are responsible for the majority of the SASM δ O-18 variability. Instead, changes in the relative moisture contributions from different source regions drive much of the SASM δ O-18 signal, with more nearby moisture sources during Northern Hemisphere summer at aphelion and more distant moisture sources during Northern Hemisphere summer at perihelion. Further, we find that evaporation amplifies the δ O-18 signal of soil water relative to that of precipitation, providing a better match with the SASM speleothem records. This work helps explain a significant portion of the long-term variability found in SASM speleothem records.
A representative cooling system for a nuclear reactor control rod drive mechanism (CRDM) includes an evaporation section located within or next to the CRDM and a condensation section fluidly coupled to the evaporation section. The cooling system includes a set of heat fins coupled to drive coils in the CRDM and heat pipes that extend through the drive coils and heat fins. A fluid evaporates while in the evaporation section of the heat pipes from heat generated by the CRDM and moves out of the evaporation section into the condensation section in the heat fins. The fluid cools and condensates while in the condensation section, recirculating back into the evaporation section. This passive natural circulation cooling system reduces or eliminates the number of water hoses, piping, and other water pumping equipment typically used for cooling a CRDM thereby increasing nuclear reactor reliability and simplifying nuclear reactor operation and maintenance.
A system for continuous, rapid deaeration of hydraulic oil has been built to replace a prior system that effected deaeration more slowly in a cyclic pressure/ vacuum process. Such systems are needed because (1) hydraulic oil has an affinity for air, typically containing between 10 and 15 volume percent of air and (2) in the original application for which these systems were built, there is a requirement to keep the proportion of dissolved air below 1 volume percent because a greater proportion can lead to pump cavitation and excessive softness in hydraulic-actuator force-versus-displacement characteristics. In addition to overcoming several deficiencies of the prior deaeration system, the present system removes water from the oil. The system (see figure) includes a pump that continuously circulates oil at a rate of 10 gal/min (38 L/min) between an 80-gal (303-L) airless reservoir and a tank containing a vacuum. When the circulation pump is started, oil is pumped, at a pressure of 120 psi (827 kPa), through a venturi tube below the tank with a connection to a stand-pipe in the tank. This action draws oil out of the tank via the standpipe. At the same time, oil is sprayed into the tank in a fine mist, thereby exposing a large amount of oil to the vacuum. When the oil level in the tank falls below the lower of two level switches, a vacuum pump is started, drawing a hard vacuum on the tank through a trap that collects any oil and water entrained in the airflow. When the oil level rises above higher of the two level switches or when the system is shut down, a solenoid valve between the tank and the vacuum pump is closed to prevent suction of oil into the vacuum pump. Critical requirements that the system is designed to satisfy include the following: 1) The circulation pump must have sufficient volume and pressure to operate the venturi tube and spray nozzles. 2) The venturi tube must be sized to empty the tank (except for the oil retained by the standpipe) and maintain a vacuum against the vacuum pump. 3) The tank must be strong enough to withstand atmospheric pressure against the vacuum inside and must have sufficient volume to enable exposure of a sufficiently large amount of sprayed oil to the vacuum. 4) The spray nozzles must be sized to atomize the oil and to ensure that the rate of flow of sprayed oil does not exceed the rate at which the venturi action can empty the tank. 5) The vacuum pump must produce a hard vacuum against the venturi tube and continue to work when it ingests some oil and water. 6) Fittings must be made vacuum tight (by use of O-rings) to prevent leakage of air into the system. The system is fully automatic, and can be allowed to remain in operation with very little monitoring. It is capable of reducing the air content of the oil from 11 to less than 1 volume percent in about 4 hours and to keep the water content below 100 parts per million.
Processes to remove and recover carbon dioxide (CO2) and water vapor from air are essential for successful long-duration space missions. This paper presents results of a developmental program focused on the use of a liquid-sorbent/membrane-contactor (LSMC) system for removal of CO2 and water vapor from air. In this system, air from the spacecraft cabin atmosphere is circulated through one side of a hollow-fiber membrane contactor. On the other side of the membrane contactor is flowed a liquid sorbent, which absorbs the CO2 and water vapor from the feed air. The liquid sorbent is then heated to desorb the CO2 and water vapor. The CO2 is subsequently removed from the system as a concentrated gas stream, whereas the water vapor is condensed, producing a water stream. A breadboard system based on this technology was designed and constructed. Tests showed that the LSMC breadboard system can produce a CO2 stream and a liquid-water stream. Details are presented on the operation of the system, as well as the effects on performance of variations in feed conditions.
Solar Fundamentals, Inc.'s hot water system employs space-derived heat pipe technology. It is used by a meat packing plant to heat water for cleaning processing machinery. Unit is complete system with water heater, hot water storage, electrical controls and auxiliary components. Other than fans and a circulating pump, there are no moving parts. System's unique design eliminates problems of balancing, leaking, corroding, and freezing.
Antarctic coastal polynyas produce dense shelf water, a primary source of Antarctic Bottom Water that contributes to the global overturning circulation. This paper investigates Antarctic dense water formation in the high-resolution version of the Energy Exascale Earth System Model (E3SM-HR). The model is able to reproduce the main Antarctic coastal polynyas, although the polynyas are smaller in area compared to observations. E3SM-HR also simulates several occurrences of open-ocean polynyas (OOPs) in the Weddell Sea at a higher rate than what the last 50 years of the satellite sea ice observational record suggests, but similarly to other high-resolution Earth system model simulations. Furthermore, the densest water masses in the model are formed within the OOPs rather than on the continental shelf as is typically observed. Biases related to the lack of dense water formation on the continental shelf are associated with overly strong atmospheric polar easterlies, which lead to a strong Antarctic Slope Front and too little exchange between on- and off-continental shelf water masses. Strong polar easterlies also produce excessive southward Ekman transport, causing a build-up of sea ice over the continental shelf and enhanced ice melting in the summer season. This, in turn, produces water masses on the continental shelf that are overly fresh and less dense relative to observations. Our results indicate that high resolution alone is insufficient for models to properly reproduce Antarctic dense water; the large-scale polar atmospheric circulation around Antarctica must also be accurately simulated.
Moist convective processes and related circulations are key components of the Earth’s climate system. Improving our understanding of moisture and cloud processes over oceans is especially challenging due to observational limitations, but also important due to the large radiative effects of cloud over ocean as well as the ties to local and global-scale circulations. A unique dataset for addressing these topics was collected over 5 flights with the NASA HALO (water vapor DIAL and aerosol HSRL) and DAWN (Doppler wind) lidar systems onboard the NASA DC-8 aircraft during the spring 2019 ADM-Aeolus Cal/Val test flight campaign. High-resolution water vapor, aerosol/cloud, and wind profiles were simultaneously collected and complimented with in situ high-resolution dropsonde measurements of temperature, relative humidity, and wind profiles. Airborne lidar measurements of these key variables captured both large-scale spatial variability across different cloud and atmospheric conditions as well as finer features, providing insight into processes from large-scale circulations down to aerosol/cloud interactions. The 5 flights spanned the northeast Pacific and southwest U.S. from 6 N to 52 N and 112 W to 157 W and captured several features of interest including moist layers from the ascending region of the Hadley circulation, very dry layers above midlatitude marine stratocumulus and cloud-free planetary boundary layers, and cloud top height and spatial variability. High covariance of aerosol and water vapor in the free troposphere was also observed for the first time. Preliminary analysis of these data sets will be presented as they apply to clouds and circulations, supplemented by model reanalysis to inform how regional water vapor structure and large-scale motion may contribute to observed shallow cloud formations and other meteorological processes that underpin our current understanding of how these state variables couple to impact the Earth’s weather and climate systems. The potential of complementary measurements in future field campaigns will also be mentioned.
Predictive models for tides, hydrodynamics, and bio-optical properties affecting the visibility and buoyancy of coastal waters are needed to evaluate the safety of personnel and equipment engaged in maritime operations under potentially hazardous conditions. Predicted currents can be markedly different for two-layer systems affected by terrestrial runoff than for well-mixed conditions because the layering decouples the surface and bottom Ekman layers and rectifies the current response to oscillatory upwelling-and downwelling-favorable winds. Standard ocean models (e.g. Princeton Ocean Model) require initial-and boundary data on the physical and optical properties of the multilayered water column to provide accurate simulations of heat budgets and circulation. Two observational systems are designed to measure vertically structured conditions on the West Florida Shelf (WFS): a tethered buoy network and an autonomous underwater vehicle (AUV) observational system. The AUV system is described with a focus on the observational systems that challenge or limit the communications command and control network for various types of measurement programs. These include vertical oscillatory missions on shelf transects to observe the optical and hydrographic properties of the water column, and bottom-following missions for measuring the bottom albedo. Models of light propagation, absorption, and conversion to heat as well as determination of the buoyancy terms for physical models require these measurements. High data rates associated with video bottom imagery are the most challenging for the real-time, command and control communications system, but they are met through a combination of loss-less and lossy data-compression methods, depending upon the data-rate of the radio links.
The possibilities and problems of extracting energy from geothermal reservoirs which do not spontaneously yield useful amounts of steam or hot water are discussed. The system for accomplishing this which is being developed first is a pressurized-water circulation loop intended for use in relatively impermeable hot rock. It will consist of two holes connected through the hot rock by a very large hydraulic fracture and connected at the surface through the primary heat exchanger of an energy utilization system. Preliminary experiments in a hole 2576 ft (0.7852 km) deep, extending about 470 ft (143 m) into the Precambrian basement rock underlying the Jemez Plateau of north-central New Mexico, revealed no unexpected difficulties in drilling or hydraulically fracturing such rock at a temperature of approximately 100 C, and demonstrated a permeability low enough so that it appeared probable that pressurized water could be contained by the basement rock. Similar experiments are in progress in a second hole, now 6701 ft (2.043 km) deep, about 1.5 miles (2.4 km) south of the first one.
A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.
Many meteoric-recharged, fault-hosted geothermal systems in amagmatic orogenic belts have been active through the Pleistocene glacial/interglacial climate fluctuations. The effects of such climate-induced recharge variations on fluid flow patterns and residence times of the thermal waters are complex and may influence how the geothermal and mineralization potential of the systems are evaluated. We report systematic thermal–hydraulic simulations designed to reveal the effects of recharge variations, using a model patterned on the orogenic geothermal system at Grimsel Pass in the Swiss Alps. Fault-bound circulation of meteoric water through the Grimsel fault is driven to depths of ~10 km by the high alpine topography. Simulations suggest that the current single pass flow is typical of interglacial periods, during which 1) meteoric recharge into the fault is high (above tens of centimeters per year), 2) conditions are at or somewhat below the critical Rayleigh number, and 3) the hydraulic connectivity along the fault plane is extensive (an extent of at least 10 km into increasingly higher terrain is required to explain the 10 km penetration depth). The subcritical condition constrains the bulk fault permeability to < 1e-14 m2. In contrast, the limited recharge during the numerous Pleistocene glaciation events likely induced a layered flow system with single pass flow confined to shallow depths while non-Rayleigh convection occurred in the deep fault. The same layering can be observed at low aspect ratios (length/depth) of the fault plane, when the available recharge area limits the flux through the fault.
Report is made of the cost analysis of four leading oxygen recovery subsystems which include two carbon dioxide reduction subsystems and two water electrolysis subsystems, namely, the solid polymer electrolyte and the circulating KOH electrolyte. The four oxygen recovery systems were quantitatively evaluated. System characteristics, including process flows, performance, and physical characteristics were also analyzed. Additionally, the status of development of each of the systems considered and the required advance technology efforts required to bring conceptual and/or pre-prototype hardware to an operational prototype status were defined. Intimate knowledge of the operations, development status, and capabilities of the systems to meet space mission requirements were found to be essential in establishing the cost estimating relationships for advanced life support systems.
Experimental and mathematical models were developed for describing and testing temperature and humidity parameters for plant production in bioregenerative life support systems. A factor was included for analyzing systems operating at low (10-101.3 kPa) pressure to reduce gas leakage and structural mass (e.g., inflatable greenhouses for space application). The expected close relationship between temperature and relative humidity was observed, along with the importance of heat exchanger coil temperature and air circulation rate. The presence of plants in closed habitats results in increased water flux through the system. Changes in pressure affect gas diffusion rates and surface boundary layers, and change convective transfer capabilities and water evaporation rates. A consistent observation from studies with plants at reduced pressures is increased evapotranspiration rates, even at constant vapor pressure deficits. This suggests that plant water status is a critical factor for managing low-pressure production systems. The approach suggested should help space mission planners design artificial environments in closed habitats.
Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.
Advanced district thermal energy systems, also known as thermal microgrids, can meet the energy needs of urban districts in a highly efficient way, but adoption of such systems, especially in the United States, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degrees F; 15-25 degrees C) temperatures, and water-source heat pumps at connected buildings are used to boost or lower the temperature for space conditioning and service hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to accelerating their adoption. This paper aims to contribute to that by reporting preliminary results from a feasibility study of a thermal microgrid at a U.S. Department of Defense installation and illustrating the process of conceptual design to seek the best possible performance within the many constraints of existing buildings. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for resilience and energy savings.
The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.