Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Centroid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Demonstration of biased membrane static figure mapping by optical beam subpixel centroid shift

The measurement of Casimir forces by means of condenser microphones has been shown to be quite promising since its early introduction almost half-a-century ago. However, unlike the remarkable progress achieved in characterizing the vibrating membrane in the dynamical case, the accurate determination of the membrane static figure under electrostatic bias remains a challenge. In this paper, we discuss our first data obtained by measuring the centroid shift of an optical beam with subpixel accuracy by charge coupled device (CCD) and by an extensive analysis of noise sources present in the experimental setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE VELOCITY CENTROID PERIODICITY OF L2 PUPPIS' SiO MASER EMISSION

We report the first short term velocity centroid (VC) periodicity derived from SiO maser emission. L2 Puppis, a semi-regular AGB star, was observed using the Mopra radio telescope of the Australia Telescope National Facility in the SiO v = 1, J = 1-0 and v = 1, J = 2-1 transitions. It exhibits a 139 day period in its SiO maser VC based on a period folding analysis and a Lomb Scargle analysis. L2 Pup's SiO maser emission has an unusually large velocity range and an unusual three-peaked spectrum. To create the change in VC the entire spectrum does not shift in velocity, but changes in the relative emission of the peaks generate the variation. The changes in the VC may be due to differential illumination, an asymmetric circumstellar distribution of material, or a mixture of causes. The unusual velocity structure, similar to that observed in Orion source 1, may be due to revolution of the circumstellar material or asymmetries in the circumstellar environment.

79 ASTRONOMY AND ASTROPHYSICS↗

Time delay and magnification centroid due to gravitational lensing by black holes and naked singularities

We model the massive dark object at the center of the Galaxy as a Schwarzschild black hole as well as Janis-Newman-Winicour naked singularities, characterized by the mass and scalar charge parameters, and study gravitational lensing (particularly time delay, magnification centroid, and total magnification) by them. We find that the lensing features are qualitatively similar (though quantitatively different) for Schwarzschild black holes, weakly naked, and marginally strongly naked singularities. However, the lensing characteristics of strongly naked singularities are qualitatively very different from those due to Schwarzschild black holes. The images produced by Schwarzschild black hole lenses and weakly naked and marginally strongly naked singularity lenses always have positive time delays. On the other hand, strongly naked singularity lenses can give rise to images with positive, zero, or negative time delays. In particular, for a large angular source position the direct image (the outermost image on the same side as the source) due to strongly naked singularity lensing always has a negative time delay. We also found that the scalar field decreases the time delay and increases the total magnification of images; this result could have important implications for cosmology. As the Janis-Newman-Winicour metric also describes the exterior gravitational field of a scalar star, naked singularities as well as scalar star lenses, if these exist in nature, will serve as more efficient cosmic telescopes than regular gravitational lenses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

4D tumor centroid tracking using orthogonal 2D dynamic MRI: Implications for radiotherapy planning

Purpose: Current pretreatment, 4D imaging techniques are suboptimal in that they sample breathing motion over a very limited “snapshot” in time. Heretofore, long-duration, 4D motion characterization for radiotherapy planning, margin optimization, and validation have been impractical for safety reasons, requiring invasive markers imaged under x-ray fluoroscopy. To characterize 3D tumor motion and associated variability over durations more consistent with treatments, the authors have developed a practical dynamic MRI (dMRI) technique employing two orthogonal planes acquired in a continuous, interleaved fashion.Methods: 2D balanced steady-state free precession MRI was acquired continuously over 9–14 min at approximately 4 Hz in three healthy volunteers using a commercial 1.5 T system; alternating orthogonal imaging planes (sagittal, coronal, sagittal, etc.) were employed. The 2D in-plane pixel resolution was 2 × 2 mm{sup 2} with a 5 mm slice profile. Simultaneous with image acquisition, the authors monitored a 1D surrogate respiratory signal using a device available with the MRI system. 2D template matching-based anatomic feature registration, or tracking, was performed independently in each orientation. 4D feature tracking at the raw frame rate was derived using spline interpolation.Results: Tracking vascular features in the lung for two volunteers and pancreatic features in one volunteer, the authors have successfully demonstrated this method. Registration error, defined here as the difference between the sagittal and coronal tracking result in the SI direction, ranged from 0.7 to 1.6 mm (1σ) which was less than the acquired image resolution. Although the healthy volunteers were instructed to relax and breathe normally, significantly variable respiration was observed. To demonstrate potential applications of this technique, the authors subsequently explored the intrafraction stability of hypothetical tumoral internal target volumes and 3D spatial probability distribution functions. The surrogate respiratory information allowed the authors to show how this technique can be used to study correlations between internal and external (surrogate) information over these prolonged durations. However, compared against the gold standard of the time stamps in the dMRI frames, the temporal synchronization of the surrogate 1D respiratory information was shown to be likely unreliable.Conclusions: The authors have established viability of a novel and practical pretreatment, 4D tumor centroid tracking method employing a commercially available dynamic MRI sequence. Further developments from the vendor are likely needed to provide a reliably synchronized surrogate 1D respiratory signal, which will likely broaden the utility of this method in the pretreatment radiotherapy planning context.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of the beam centroid of an obstructed focused Gaussian laser beam

Diffraction of an obstructed focused Gaussian laser beam has been treated theoretically using the Huygens-Fresnel diffraction integral and was found to be in good agreement with experimental measurements. The obstruction is a vertically oriented opaque cylinder treated as a flat hard aperture. Measurements and calculations are compared for the diffracted irradiance profile and the beam centroid as a function of cylinder diameter and lateral and longitudinal placement along the optic axis. The cylinders used were gauge pins and/or wires with diameters from 0.5 to 100 mil.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GPU Acceleration of Volume Fraction and Centroid Computation from General Shapes on Unstructured Mesh

One important requirement for coupling multi-physics models is a means to remap fields between meshes in an accurate and conservative manner. Since the remapping algorithm is embarrassingly parallel, this motivates the use of Graphical Processing Units (GPU) for such routine. However, since our remapping code, portage, is fairly complex, we explore the use of GPUs through a simpler problem of generating material’s volume fraction and centroid inside each cell of the mesh. We use the same programming structure that is used in portage, namely, on-node parallelism via NVIDIA’s thrust library. Using a similar programming structure enables us to draw lessons from this study that can be applied to the more complex problem. We have found that while the speed-up is pronounced (10-100 times), significant effort is required to re-factor the code so that thrust can be used with a CUDA backend. Moreover, thrust takes away the fine grain control that vanilla CUDA programming gives us.

97 MATHEMATICS AND COMPUTING↗

Centroids, moments, and radii of gyration

Computer program finds area, centroid, moments of inertia, product of inertia, and radii of gyration of closed curve given in graphical form such as on engineering drawing or strip chart. System is applicable when finding volume and center of gravity for liquid tanks, or for detecting buoyancy of hull sections.

Patch, R. W.↗

Wedge-and-strip anodes for centroid-finding position-sensitive photon and particle detectors

The paper examines geometries employing position-dependent charge partitioning to obtain a two-dimensional position signal from each detected photon or particle. Requiring three or four anode electrodes and signal paths, images have little distortion and resolution is not limited by thermal noise. An analysis of the geometrical image nonlinearity between event centroid location and the charge partition ratios is presented. In addition, fabrication and testing of two wedge-and-strip anode systems are discussed. Images obtained with EUV radiation and microchannel plates verify the predicted performance, with further resolution improvements achieved by adopting low noise signal circuitry. Also discussed are the designs of practical X-ray, EUV, and charged particle image systems.

Martin, C.↗

Optimal Doppler centroid estimation for SAR data from a quasi-homogeneous source

This correspondence briefly describes two Doppler centroid estimation (DCE) algorithms, provides a performance summary for these algorithms, and presents the experimental results. These algorithms include that of Li et al. (1985) and a newly developed one that is optimized for quasi-homogeneous sources. The performance enhancement achieved by the optimal DCE algorithm is clearly demonstrated by the experimental results.

Jin, M. Y.↗

Centroid position measurements and subpixel sensitivity variations with the MAMA detector

Initial measurements of the position sensitivity of a visible-light multianode microchannel array detector show that centroid calculations for image spots are accurate to better than 0.04 pixels even with sources that are essentially delta functions at the photocathode.Subpixel sensitivity variations of 10-15 percent are typically found for pixels in the array. Variations as large as 30 percent are possible in the worst conditions. These variations limit the photometric accuracy of the detector when very small scale features are observed. The photometric accuracy and the position sensitivity of the detector appear to be limited by cross-coupling effects within the anode array. Initial measurements with more recent designs of the detector show that most or all of this cross-coupling has been eliminated.

Morgan, Jeffrey S.↗

Ambiguity Of Doppler Centroid In Synthetic-Aperture Radar

Paper discusses performances of two algorithms for resolution of ambiguity in estimated Doppler centroid frequency of echoes in synthetic-aperture radar. One based on range-cross-correlation technique, other based on multiple-pulse-repetition-frequency technique.

Chang, Chi-Yung↗

ACE: Automatic Centroid Extractor for real time target tracking

A high performance video image processor has been implemented which is capable of grouping contiguous pixels from a raster scan image into groups and then calculating centroid information for each object in a frame. The algorithm employed to group pixels is very efficient and is guaranteed to work properly for all convex shapes as well as most concave shapes. Processing speeds are adequate for real time processing of video images having a pixel rate of up to 20 million pixels per second. Pixels may be up to 8 bits wide. The processor is designed to interface directly to a transputer serial link communications channel with no additional hardware. The full custom VLSI processor was implemented in a 1.6 mu m CMOS process and measures 7200 mu m on a side.

Cameron, K.↗

Centroid Detector Assembly for the AXAF-I Alignment Test System

The High Resolution Mirror Assembly (HRMA) of the Advanced X-ray Astrophysics Facility (imaging) (AXAF-I) consists of four nested paraboloids and four nested hyperboloids, all of meter-class size, and all of which are to be assembled and aligned in a special 15 meter tower at Eastman Kodak Company in Rochester, NY. The goals of the alignment are (1) to make the images of the four telescopes coincident; (2) to remove coma from each image individually; and (3) to control and determine the final position of the composite focus. This will be accomplished by the HRMA Aligment Test System (HATS) which is essentially a scanning Hartmann test system. The scanning laser source and the focal plane of the HATS are part of the Centroid Detector Assembly (CDA) which also includes processing electronics and software. In this paper we discuss the design and the measured performance of the CDA.

Glenn, Paul↗

Rapid Centroids and the Refined Position Accuracy of the Swift Gamma-ray Burst Catalogue

The Swift X-ray Telescope autonomously refines the Burst Alert Telescope positions (approx.1-4' uncertainty) to better than 5 arcsec, within 5 seconds of target acquisition by the observatory for typical bursts. The results of the rapid positioning capability of the XRT are presented here for both known sources and newly discovered GRBs, demonstrating the ability to automatically utilize one of two integration times according to the burst brightness, and to correct the position for alignment offsets caused by the fast pointing performance and variable thermal environment of the satellite as measured by the Telescope Alignment Monitor. We present an evaluation of the position accuracy for both the onboard centroiding software and the ground software for the calibration targets and show that a significant improvement in position accuracy is obtained if the boresight detector position is optimized relative to the spacecraft pointing. Finally, we present an updated catalogue of Swift GRB X-ray positions obtained in Photon Counting Mode using the improved, calibrated boresight.

Hill, J. E.↗

Method for measuring centroid algorithm accuracy

This paper will describe such a method for measuring the accuracy of centroid algorithms using a relatively inexpensive setup consisting of a white light source, lenses, a CCD camea, an electro-strictive actuator, and a DAC (Digital-to-Analog Converter), and employing embedded PowerPC, VxWorks, and Solaris based software.

technical keywords↗