Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Centrifugation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Gender Differences in Cardiovascular Tolerance to Short Arm Centrifugation

In preparation for the NASA Artificial Gravity (AG) pilot study, the tolerability of the proposed AG parameters was tested in 11 ambulatory human subjects (6m, 5w) by exposing each to a short arm centrifuge trial. Subjects were oriented in the supine position (but inclined 6deg head down) on one arm of the centrifuge, and the rotation rate (30.6-33.4 rpm) and radial position of the feet were set to produce 2.5G of equivalent gravitational load at the force plate directly beneath the feet, 1G at the level of the mediastinum, and approximately 0.55G at the labyrinth. Amongst the 6 men participating in this preliminary study, 5 completed at least 60 minutes of the trial successfully with no adverse sequelae. However, amongst the female cohort the test was stopped by the medical monitor before 60 min in all but one case, with pre-syncope listed as the reason for termination in all cases. Mean time before abort of the centrifuge run amongst the women was 33.2 +/- 20.97 min. It is known that women have a greater predisposition to syncope during orthostatic stress, under normal tilt table conditions, during LBNP, and following space flight. The reasons for this difference are the subject of some debate, but anthropometric factors, the vasoactive effects of sex hormones, gender differences in susceptibility to motion sickness, catecholamine levels, ability to augment total peripheral resistance in response to orthostatic stress, and structural differences in cardiac anatomy and physiology have all been suggested. This finding led to the exclusion of women from the AG pilot study. Clearly if AG is to be employed as a multi-system countermeasure it must provide physiological protection at rotation rates within the tolerance limits of all potential astronauts. Further investigation of the responses of women to centrifugation will be necessary to determine how to adjust AG parameters for tolerance by female subjects before a more detailed investigation of the appropriate dose in terms of G load, rotation rate, exposure duration and frequency can be performed.

Fong, Kevin J.↗

Centrifugal Adsorption Cartridge System

The centrifugal adsorption cartridge system (CACS) is an apparatus that recovers one or more bioproduct(s) from a dilute aqueous solution or suspension flowing from a bioreactor. The CACS can be used both on Earth in unit gravity and in space in low gravity. The CACS can be connected downstream from the bioreactor; alternatively, it can be connected into a flow loop that includes the bioreactor so that the liquid can be recycled. A centrifugal adsorption cartridge in the CACS (see figure) includes two concentric cylinders with a spiral ramp between them. The volume between the inner and outer cylinders, and between the turns of the spiral ramp is packed with an adsorbent material. The inner cylinder is a sieve tube covered with a gas-permeable, hydrophobic membrane. During operation, the liquid effluent from the bioreactor is introduced at one end of the spiral ramp, which then constrains the liquid to flow along the spiral path through the adsorbent material. The spiral ramp also makes the flow more nearly uniform than it would otherwise be, and it minimizes any channeling other than that of the spiral flow itself. The adsorbent material is formulated to selectively capture the bioproduct(s) of interest. The bioproduct(s) can then be stored in bound form in the cartridge or else eluted from the cartridge. The centrifugal effect of the spiral flow is utilized to remove gas bubbles from the liquid. The centrifugal effect forces the bubbles radially inward, toward and through the membrane of the inner cylinder. The gas-permeable, hydrophobic membrane allows the bubbles to enter the inner cylinder while keeping the liquid out. The bubbles that thus enter the cylinder are vented to the atmosphere. The spacing between the ramps determines rate of flow along the spiral, and thereby affects the air-bubble-removal efficiency. The spacing between the ramps also determines the length of the fluid path through the cartridge adsorbent, and thus affects the bioproduct-capture efficiency of the cartridge. Depending on the application, several cartridges could be connected in a serial or parallel flow arrangement. A parallel arrangement can be used to increase product-capturing and flow capacities while maintaining a low pressure drop. A serial arrangement can be used to obtain high product-capturing capacity; alternatively, series-connected cartridges can be packed with different adsorbents to capture different bioproducts simultaneously.

Gonda, Steve R.↗

Space-Cent: Studying the Physiological and Anatomical Effects of Centrifugation and Head Down Tilt: 2021 Update

BACKGROUND The objective of this study was to evaluate the cerebral and ocular physiological and anatomical effects of head-down tilt bedrest (HDBR) with and without daily artificial gravity (AG) in healthy subjects to provide novel insights into possible countermeasures for the Spaceflight Associated Neuro-ocular Syndrome (SANS). Previous long-term studies using the spaceflight analog of strict 6° HDBR for 30 days revealed changes in ocular structure, including optic disc edema. The effects of an AG countermeasure using intermittent centrifugation to restore upright hydrostatic gradients and reduce the ocular and brain anatomical effects has not been explored. METHODS The effects of 60-day exposure to simulated microgravity (6° HDBR) on the cerebral, ocular and vestibular systems with and without the intervention of daily 30 minute exposure to AG (short-arm centrifugation) was evaluated in 24 healthy subjects. Non-invasive measurements of cerebral blood flow, intracranial blood volume (near infrared spectroscopy, NIRS), cerebral and ocular structure (MRI and optical coherence tomography), internal jugular vein area (ultrasound), lateral ventricular volumes (MRI), intraocular pressure, and sensorimotor/vestibular (i.e. balance and coordination) systems were made during various time-points during the bedrest study. Additional measures with ultrasound and NIRS were made during centrifugation. RESULTS The study began in Spring 2019 and all 24 subjects completed the testing by end of 2019. Data analysis continues. We report the following updated results for 2021. MRI showed significant decreases in carotid artery flow, increases in brain and CSF volumes, and aqueductal flow velocities in all subjects in HDT compared to baseline supine, but no effects of the short duration AG. All groups showed increased posterior globe flattening during bedrest compared to baseline, without protection from AG. As previously reported we observed chorioretinal folds for the first time in a bedrest analog, as well as optic disc edema, with no protection from the short-term AG. Data from the study is now being transmitted to the NASA LSDA which will allow for future research. CONCLUSIONS The 6 degree HDBR analog produced significant changes in the anatomical and physiological functions of the brain and eye in healthy subjects. Daily 30 minute exposure to AG with short-arm centrifugation had significant transient effects on physiology of the cerebrovascular system, but was not sufficient to prevent the anatomical effects of HDBR on the brain and eye.

E M Bershad↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

Orientation illusions and heart-rate changes during short-radius centrifugation

Intermittent short-radius centrifugation is a promising countermeasure against the adverse effects of prolonged weightlessness. To assess the feasibility of this countermeasure, we need to understand the disturbing sensory effects that accompany some movements carried out during rotation. We tested 20 subjects who executed yaw and pitch head movements while rotating at constant angular velocity. They were supine with their main body axis perpendicular to earth gravity. The head was placed at the centrifuge's axis of rotation. Head movements produced a transient elevation of heart-rate. All observers reported head-contingent sensations of body tilt although their bodies remained supine. Mostly, the subjective sensations conform to a model based on semicircular canal responses to angular acceleration. However, some surprising deviations from the model were found. Also, large inter-individual differences in direction, magnitude, and quality of the illusory body tilt were observed. The results have implications for subject screening and prediction of subjective tolerance for centrifugation.

NASA Discipline Neuroscience↗

High Efficiency Centrifugal Compressor for Rotorcraft Applications

A centrifugal compressor research effort conducted by United Technologies Research Center under NASA Research Announcement NNC08CB03C is documented. The objectives were to identify key technical barriers to advancing the aerodynamic performance of high-efficiency, high work factor, compact centrifugal compressor aft-stages for turboshaft engines; to acquire measurements needed to overcome the technical barriers and inform future designs; to design, fabricate, and test a new research compressor in which to acquire the requisite flow field data. A new High-Efficiency Centrifugal Compressor stage -- splittered impeller, splittered diffuser, 90 degree bend, and exit guide vanes -- with aerodynamically aggressive performance and configuration (compactness) goals were designed, fabricated, and subquently tested at the NASA Glenn Research Center.

Centrifugal compressor↗

Development of a Computational Fluid Dynamics Model for a High-Speed Centrifugal Compressor

Computational fluid dynamics (CFD) has become widely used in the design and analysis of turbomachinery components such as centrifugal compressors. However, CFD is only a limited representation of experimental cases and struggles to model complex flows or can lack small model details to increase computation speed. To make advancements in compressor technology, designers need tools like CFD that can help them predict flow behavior in new designs. The High Efficiency Centrifugal Compressor (HECC) was designed by United Technologies Research Center (UTRC) for NASA to investigate the difficulties behind improving centrifugal compressor technology and to provide an open case to the turbomachinery research community. CFD analysis was completed by UTRC to aid in the design process. The pre-test study significantly overpredicted the compressor’s performance, and while post-test analysis was more representative, its results have yet to be publicly available. CFD technology has also since improved in recent years. In this study, a high-fidelity computational model for the vaneless configuration of HECC operating at its design point was developed and compared to an equivalent experimental case. This model incorporated GPU versions of mesh generation and solver codes from AeroDynamic Solutions, Inc. The development of such a model is significant since there has yet to be a published numerical simulation of HECC’s vaneless configuration. Additionally, the use of GPU codes decreases computation times for the model, which has allowed for the inclusion of impeller blade fillets. Initial results showed a general overprediction of compressor performance by the model. Predictions were more accurate for the impeller compared to predictions for the full compressor stage. Spanwise analyses showed that the model tended to follow flow behavior patterns exhibited in the experiment. Beyond this study, this model will be iterated upon and experimentally validated to further examine HECC performance.

centrifugal compressor↗

GT2024-139262: Development of a Computational Fluid Dynamics Model for a High-Speed Centrifugal Compressor

Computational fluid dynamics (CFD) has become widely used in the design and analysis of turbomachinery components such as centrifugal compressors. However, CFD is only a limited representation of experimental cases and struggles to model complex flows or lack model details to increase computation speed. The High Efficiency Centrifugal Compressor (HECC) was designed by United Technologies Research Center for NASA to investigate the difficulties behind improving centrifugal compressor technology and to provide an open case to the turbomachinery research community. The CFD technology seen in previous numerical models of the compressor have improved since then. In this study, a high-fidelity computational model for the vaneless configuration of HECC operating at its design point was developed and compared to an equivalent experimental case. This model incorporated GPU versions of mesh generation code WAND and solver code LEO from AeroDynamic Solutions, Inc. Blade sections extracted from the solid model formed the basis of the impeller mesh, while the remainder of the stage was modeled as ducts. Standard day aerodynamic conditions, design rotational speed, design mass flow rate, and inlet flow angles served as additional inputs. A mesh sensitivity study was performed prior to using the model for analysis. The accuracy of the model’s predictions of impeller and stage performance were assessed by comparing the total pressure ratio, total temperature rise ratio, and adiabatic efficiency to the corresponding parameters observed in the experimental case. Results showed a general overprediction of compressor performance by the model. Predictions were more accurate for the impeller performance compared to those for the full compressor stage. Spanwise analyses showed that the model tended to follow flow behavior patterns exhibited in the experiment. Beyond this study, this model was used to examine HECC aerodynamics and performance in research following thereafter.

centrifugal compressor↗

Enhancing Molecular Isotope Detection with a Chirp Tuned Optical Centrifuge

This paper gives a brief experimental overview on creating a chirp-tunable optical centrifuge with the goal of amplifying the isotope shift of a given molecule. Results for this experiment were recorded with a CO 2 plume as the probed material. Beyond amplification of the isotope shift, this technology could be modified to alter magnetic field characteristics of common molecules as well as simulating high temperature gases found in combustion environments. Our specific design uses double mirror and grating stretcher and will include a unique tuning feature for customization of the beam’s red and blue components' temporal chirp, allowing for quick reactivity to varying task requirements. The design and parameters will be discussed, as well as the methods used to model the optical centrifuge. Although this experiment is ongoing, results have been gathered previously that display the efficacy of the optical centrifuge. For the probed CO 2 sample, Raman Shifts centered around a wavenumber of 60 and 275 were recorded with durations of 1000 and 800 picoseconds, respectively.

47 OTHER INSTRUMENTATION↗

Effects of bedrest and centrifugation of humans on serum thyroid function tests.

Changes in plasma volume and protein concentration have been reported when normal subjects are bedrested or centrifuged. Since thyroid hormones are transported by specific plasma proteins, each of these procedures could be expected to change plasma levels of these hormones. In this study centrifugation of normal healthy human subjects produced an increased concentration of total protein and albumin. When these same subjects were bedrested for six days, no change in total protein, albumin or thyroxine binding globulin were found although there was an eight per cent decrease in plasma volume. Centrifugation and, to a lesser extent, bedrest produced changes in serum T-4 levels and the T-3 test results. The direction of these changes (decreased % T-3 values and increased T-4 levels) indicate that these two situations produce an increased plasma concentration of thyroxine binding sites.

Leach, C. S.↗

Erosion in radial inflow turbines. Volume 2: Balance of centrifugal and radial drag forces on erosive particles

The particle motion in two-dimensional free and forced inward flowing vortices is considered. A particle in such a flow field experiences a balance between the aerodynamic drag forces that tend to drive erosive particles toward the axis, and centrifugal forces that prevent these particles from traveling toward the axis. Results predict that certain sizes of particles will achieve a stable orbit about the turbine axis in the inward flowing free vortex. In this condition, the radial drag force is equal to the centrifugal force. The sizes of particles that will achieve a stable orbit is shown to be related to the gas flow velocity diagram at a particular radius. A second analysis yields a description of particle sizes that will experience a centrifugal force that is greater than the radial component of the aerodynamic drag force for a more general type of particle motion.

Clevenger, W. B., Jr.↗

Morphology of Arabidopsis grown under chronic centrifugation and on the clinostat

Morphological measurements were made on populations of Arabidopsis thaliana grown from seed for 21 days under essentially constant environmental conditions except for the influence of gravitational or centrifugal accelerations. Growth conditions were what had been proposed for experiments in an artificial satellite. Observations are reported for plants grown at normal 1-g upright or on horizontal clinostats and for plants grown on a centrifuge. Increased g-force, up to 15 times normal, was found to have significant but small effects on some morphological end points. The plants' sensitivity to the magnitude of the g-force was much less than to its vector direction. Data from centrifuge experiments were extrapolated to zero-g to predict a set of morphological characteristics of a plant developing in the satellite environment. As an alternative means of predicting properties of a zero-g plant, characteristics of plants grown on horizontal clinostats were measured. The results of these two predictive methods were not in agreement. Clinostat grown plants were morphologically distinct from upright stationary controls.

Brown, A. H.↗

Microvascular pressure responses of second-generation rats chronically exposed to 2 g centrifugation

Preliminary results are presented for a study aimed at a quantitative comparison of microvascular dynamics in second-generation rats reared in a 2-g force field produced by centrifugation with similar data from animals reared in a centrifuge that produced only a 1-g force. It is shown that the pressure distribution in the mesenteric microvasculature of the second generation of rats reared in a 2-g environment, as well as the animals' blood pressure response to epinephrine, are significantly different compared to their 1-g counterparts. In particular, 1-g and 2-g chronic centrifugation enhances the arterial blood pressure, and the 2-g force field attenuates the pressor effects of norepinephrine.

Richardson, D. R.↗

Femoral development in chronically centrifuged rats

Groups of 30-d-old male and female rats were centrifuged at 2.00 G (RE, Rotation Experimental), 1.05 G (RC, Rotation Control) or exposed to the noise and wind of the centrifuge at 1.00 G (EC, Earth Control) for periods of 1, 2, 4, 8, and 16 weeks. Measurements of their femurs indicated that exposure to centrifugation a) decreased femoral length in RE animals, b) increased femoral length in RC animals, c) reduced femoral diameter in RE and RC animals, d) increased L/D ratios in RC animals, e) decreased L/D ratios in RE animals, f) increased femur length/body weight in RE animals, g) decreased cortical thickness (CT) in RE animals, h) increased relative CT in RE animals, and decreased it in RC animals, i) accelerated ossification in RC femoral heads, j) thinned and distorted RE epiphyseal plates, and k) thickened condylar cartilage in RE females. The effects tended to be strongly sexually dimorphic, with females more severely affected by the stress than males.

Smith, S. D.↗

Laminar flow effects in the coil planet centrifuge

The coil planet centrifuge designed by Ito employs flow of a single liquid phase, through a rotating coiled tube in a centrifugal force field, to provide a separation of particles based on sedimentation rates. Mathematical solutions are derived for the linear differential equations governing particle behavior in the coil planet centrifuge device. These solutions are then applied as the basis of a model for optimizing particle separations.

Herrmann, F. T.↗

Effects of chronic centrifugation on mice

Previous studies have shown that exposure to excess gravity in vitro alters the developmental sequence in embryonic mouse limbs and palates (Duke, Janer and Campbell, 1984; Duke, 1983). The effects of excess gravity on in vivo mammalian development was investigated using a small animal centrifuge. Four-week old female mice exposed to excess gravities of 1.8-3.5 G for eight weeks weighed significantly less than controls. Mice were mated after five weeks of adaptation to excess G, and sacrificed either at gestational day 12 or 18. There were fewer pregnancies in the centrifuged group (4/36) than in controls (9/31), and crown rump lengths (CRL) of embryos developing in the centrifuge were less than CRLs of 1-G embryos. These results show that although immersed in amniotic fluid, embryos are responsive to Delta-G.

Janer, L.↗

The influence of centrifugal forces on the B field structure of an axially symmetric equilibrium magnetosphere

A model is presented of an axially symmetric pole-on magnetosphere in MHD force balance, in which both plasma thermal pressure gradients and centrifugal force are taken into account. Assuming that planetary rotation leads to differentially rotating magnetotail field lines, the deformation of magnetotail field lines under the influence of both thermal plasma pressure and centrifugal forces was calculated. Analytic solutions to the Grad-Shafranov equation are presented, which include the centrifugal force term. It is shown that the nonrotational magnetosphere with hot thermal plasma leads to a field configuration without a toroidal B(phi) component and without field-aligned Birkeland currents. The other extreme, a rapidly rotating magnetosphere with cold plasma, leads to a configuration in which plasma must be confined within a thin disk in a plane where the radial magnetic field component B(r) vanishes locally.

Ye, Gang↗

NASA low-speed centrifugal compressor for 3-D viscous code assessment and fundamental flow physics research

A low speed centrifugal compressor facility recently built by the NASA Lewis Research Center is described. The purpose of this facility is to obtain detailed flow field measurements for computational fluid dynamic code assessment and flow physics modeling in support of Army and NASA efforts to advance small gas turbine engine technology. The facility is heavily instrumented with pressure and temperature probes, both in the stationary and rotating frames of reference, and has provisions for flow visualization and laser velocimetry. The facility will accommodate rotational speeds to 2400 rpm and is rated at pressures to 1.25 atm. The initial compressor stage being tested is geometrically and dynamically representative of modern high-performance centrifugal compressor stages with the exception of Mach number levels. Preliminary experimental investigations of inlet and exit flow uniformly and measurement repeatability are presented. These results demonstrate the high quality of the data which may be expected from this facility. The significance of synergism between computational fluid dynamic analysis and experimentation throughout the development of the low speed centrifugal compressor facility is demonstrated.

Hathaway, M. D.↗