Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capillary waves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Real-time observation of dynamic structure of liquid-vapor interface at nanometer resolution in electron irradiated sodium chloride crystals

The dynamics and structure of the liquid and vapor interface has remained elusive for decades due to the lack of an effective tool for directly visualization beyond micrometer resolution. Here, we designed a simple liquid-cell for encapsulating the liquid state of sodium for transmission electron microscopic (TEM) observation. The real-time dynamic structure of the liquid-vapor interface was imaged and videoed by TEM on the sample of electron irradiated sodium chloride (NaCl) crystals, a well-studied sample with low melting temperature and quantum super-shells of clusters. The nanometer resolution images exhibit the fine structures of the capillary waves, composed of first-time observed three zones of structures and features, i.e. flexible nanoscale fibers, nanoparticles/clusters, and a low-pressure area that sucks the nanoparticles from the liquid to the interface. Although the phenomenons were observed based on irradiated NaCl crystals, the similarities of the phenomenons to predictions suggest our real-time ovserved dynamic structure might be useful in validating long-debated theoretical models of the liquid-vapor interface, and enhancing our knowledge in understanding the non-equilibrium thermodynamics of the liquid-vapor interface to benefit future engineering designs in microfluidics.

36 MATERIALS SCIENCE↗

Transient dynamics in drop impact on a superheated surface

When a drop impinges on a superheated surface, a Leidenfrost vapor layer forms between the drop and the surface. Transient dynamics of the layer can play a critical role for cooling in power plants but is not fully understood. Here we successfully visualize transient dynamics of the layer using ultrafast X-ray imaging. We reveal that a vapor disk with a homogeneous thickness, developed during drop impact, grows in thickness following the Fourier law. At a certain thickness (12 ± 2 μm in this study) of the vapor disk, ripples generate at its periphery due to capillary waves, resulting in significant enhancement of drop vaporization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiphysics modeling of mesh piezoelectric atomizers

An ultrasonic clothes dryer was developed by researchers at Oak Ridge National Laboratory based on a novel approach of using high-frequency mechanical vibration instead of heat to extract moisture as a cold mist. This technology is based on direct mechanical coupling between mesh piezoelectric (PZT) transducers and wet fabric. The vibration introduces sufficient momentum to the droplets trapped in the fabric pores to atomize them and leave the garment in a cold state. In the vibrating transducer, deformation followed by the effects of boundary layer acoustic streaming results in ejection of the atomized droplets. The research presented bridges the vibration of a PZT mesh transducer to the induced acoustic field and to capillary-wave theory. Mathematical modeling studies free and forced vibrations of a mesh-like PZT structure, using the structural parameters identified by actuation testing in several case studies. Computational fluid–structure interaction modeling is performed to couple the vibrations of a PZT transducer with an in-contact droplet. The results obtained are used to investigate (1) the transverse deformation of the vibrating mesh transducer in contact with a droplet, (2) the resultant boundary layer acoustic streaming in the fluid surrounding the vibrating surface, and (3) the droplet deformation and fluid ejection. The physics of atomization are linked to the level of the near-wall droplet vibrations induced by the surface deformation of the transducer. Then the surface deformation is linked to the properties of the PZT mesh transducer and input actuation frequency and power.

Dupuis, Eric↗

Detection of oil spills using 13.3 GHz radar scatterometer

The results of an analysis of 13.3-GHz single polarized scatterometer data collected during NASA/MSC Mission 135, flown on March 16, 1970 are reported. Data were gathered over a crude oil spill on the Gulf of Mexico off the Mississippi Delta. With the aid of RC-8 camera photographs, the scattering cross section was correlated with the extent of the oil spill. The scattering cross section at higher incidence angles decreased by 5 db to 10 db in the presence of the oil spill. This was attributed to oil's damping of small gravity and capillary waves. The composite scattering theory and the scatterometer acquired data were used to obtain an expression of radar scattering over ocean surfaces with oil spills. The study demonstrates that the presence and extent of oil spills can be detected using high frequency radar systems.

Krishen, K.↗

Laboratory investigations related to microwaves

The investigation in a laboratory controlled environment was of the structure of the water surface and the immediate layers above and below the surface. The scope included: (1) the investigation of the capillary waves and their interaction with gravity waves, (2) the formation of whitecaps at different wind speeds and the influence of gravity waves on whitecaps, and (3) the wind-generated spray under different wind and wave conditions.

Shemdin, O. H.↗

The extrapolation of laboratory and aircraft radar sea return data to spacecraft altitudes

Laboratory measurements show that the spectra of capillary waves grow with wind speed over six orders of magnitude. The scatter in the data can be partially understood and predicted from a combination of turbulence theory, radar theory, and the small sample theory of statistical inference. When these results are applied to a prediction of the sea return values to be obtained by S193 on Skylab, it can be shown that the size of the illuminated patch effectively averages out the horizontal scales of gustiness, so that the measurement will correspond to the synoptic scale wind.

Pierson, W. J.↗

The composite scattering model for radar sea return

A composite scattering model, suitable for explaining the behavior of measured scattering cross sections of the ocean surface, is presented. Furthermore, utilizing this scattering model, the spectrums of the small gravity, gravity-capillary, waves will be predicted for MSA/MSC, 13.3 GHz Scatterometer data.

Krishen, K.↗

Detection of oil spills using a 13.3-GHz radar scatterometer.

This paper describes the results of an analysis of 13.3-GHz single-polarized scatterometer data collected during NASA/MSC mission 135, flown on March 16, 1970. Data were gathered over a crude oil spill on the Gulf of Mexico (test site 128) off the Mississippi delta. With the aid of RC-8 camera photographs the scattering cross section was correlated with the extent of the oil spill. The scattering cross section at higher incidence angles (25 to 50 deg) decreased by 5-10 db in the presence of the oil spill. This was attributed to the damping by oil of small gravity and capillary waves. The composite scattering theory and the scatterometer-acquired data were used to obtain an expression of radar scattering over ocean surfaces with oil spills. The study demonstrates that the presence and extent of oil spills can be detected with high-frequency radar systems.

Krishen, K.↗

Studies of rotating liquid floating zones on Skylab IV

Liquid zones of water, soap solution and soap foam were deployed between two aligned circular disks which were free to rotate about the zone axis in the microgravity environment of Skylab IV. Such a configuration is of interest in the containerless handling of melts for possible future space processing crystal growth experiments. Three basic types of zone surface deformation and instability were observed for these rotational conditions; axisymmetric shape changes under single disk rotation, nonaxisymmetric, whirling, C-modes for long zones with equal rotation of both disks, and capillary wave phenomena for short zones with equal rotation of both disks. The sources of these instabilities and the conditions promoting them are analyzed in detail from video tape recordings of the Skylab experiments.

Carruthers, J. R.↗

Dynamics of superfluid helium in zero gravity

The Spacelab 2 superfluid helium experiment was designed to: (1) examine the behavior of capillary waves and measure their velocity and dampling; (2) study the sloshing motion of bulk superfluid helium in near-zero gravity in order to determine its effects on sensors and attitude control systems for far infrared telescopes; and (3) determine the temperature distributions in the liquid and their correlation with bulk motion. The experiment system includes a helium cryostat with a sensor head and a microcomputer to provide electrical excitation and gather and transmit resultant responses to the experiment teams on the ground. Astronaut intervention is possible.

Mason, P. V.↗

Liquid drop technique for generation of organic glass and metal shells

It was found that liquid drop techniques are very useful in several diverse areas. For producing very uniform metallic, organic, inorganic and, on particular, glassy shells, the liquid jet method is the most reproducible and exceptionally useful of all the techniques studied. The technique of capillary wave synchronization of the break-up of single and multiple component jets was utilized to produce uniform sized liquid drops and solid particles, and hollow liquid and solid shells. The technique was also used to encapsulate a number of liquids in impermeable spherical shells. Highly uniform glass shells were made by generating uniform drops of glass forming materials in an aqueous solution, subsequently evaporating the water, and then fusing and blowing the remaining solids in a high temperature vertical tube furnace. Experimental results are presented and the critical problems in further research in this field are discussed.

Hendricks, C. D.↗

Surface fluctuation spectroscopy - A novel technique for characterizing liquid interfaces

Surface fluctuation spectroscopy is a dynamic light scattering technique which involves the detection of thermal fluctuations (capillary waves) that cover every liquid interface. The advantages of this technique over conventional mechanical methods are discussed. The signal resolution and precision are improved by using a grating heterodyne technique coupled with a digital correlator. Detailed calculations showed that, for the measured power spectrum (the Fourier transform of the correlation function) to take the Lorentzian shape, it is necessary that certain optical conditions be met. These conditions are demonstrated with experimental data collected for ethanol at the ambient temperature as a function of the wave number. Once the optical parameters are adjusted correctly, the experimental results show excellent agreement with the literature values. It is also demonstrated that, using microcomputer technology, the entire system can be automated.

Shih, L. B.↗

Structure of a fluid interface near the critical point

The structure of the liquid-liquid interface of three very different mixtures (carbon disulfide + methanol, methanol + cyclohexane + deuterated cyclohexane, and nitrobenzene + n-decane) has been studied using ellipsometry in the reduced temperature range between 0.0009 and 0.042. Although the elliptical thickness varies by an order of magnitude between these mixtures, the data from all three mixtures can be scaled to the same universal constant by a combined mean-field plus capillary-wave model of the interface. The universal constant determined experimentally is significantly less than the theoretical value.

Schmidt, James W.↗

On the temperature of surfaces

The concept of the temperature of a surface is introduced from the viewpoint of the physical chemistry of surfaces. The surface, near surface and microlayer regions of the interface are defined. Most methods measure the temperature of the microlayer or at best the near surface region and may err in representing the surface temperature. Methods based on capillary ripples actually measure the surface temperature since surface tension (or surface tension tensor when a monolayer has been spread or absorbed at the interface) is the main restoring force that controls their propagation. Light scattering methods are described for determining the elevation of very small amplitude capillary waves through the computation of various correlation functions from which the surface tension can be estimated. Procedures for estimating the surface temperature are described.

Mann, J. Adin, Jr.↗

Cryogenic liquid-jet breakup in two-fluid atomizers

A two-fluid atomizer was used to study the breakup of liquid-nitrogen jets in nitrogen, argon, and helium atomizing gas flows. A scattered-light scanner particle sizing instrument previously developed at NASA Lewis Research Center was further developed and used to determine characteristic drop diameters for the cryogenic sprays. In the breakup regime of aerodynamic-stripping, i.e., sonic-velocity conditions, the following correlation of the reciprocal Sauter mean diameter, D(sub 32)exp -1, with the atomizing-gas flowrate, W(g), was obtained: D(sub 32)exp -1 = k(sub c)(W(g)exp 1.33), where k(sub c) is a proportionality constant evaluated for each atomizing gas. Values of k(sub c) = 120, 220, and 1100 were obtained for argon, nitrogen, and helium gasflows, respectively. The reciprocal Sauter mean diameter and gas flowrate have the units of 1/cm and g/sec, respectively. In the regime of capillary-wave breakup, or subsonic conditions, it was found that D(sub 32)exp -1 = k(g)(W(g)exp 0.75), where k = 270, 390, and 880 for argon, nitrogen, and helium gasflows, respectively.

Ingebo, Robert D.↗

Jet-A fuel evaporation analysis in conical tube injectors

A simple one-dimensional drop-life-history analysis and a multidimensional spray calculation using KIVA-II code are applied to the vaporization of Jet-A fuel in multiple tube injectors. Within the assumptions of the analysis, the one-dimensional results are useful for design purposes. The pressure-atomizer breakup models do not accurately predict the dropsize measured experimentally or deduced from the one-dimensional analysis. Cold flow visualization and dropsize measurements show that capillary wave breakup mechanism plays an important role in the spray angle and droplet impingement on the tube wall.

Lai, M.-C.↗

Static shape and instability of an acoustically levitated liquid drop

Dynamical aspects of a drop drastically flattened by acoustic radiation stress are considered. Its static equilibrium has been studied, starting with a dislike shape and modeling the sound field and the associated radiation stress according to this geometry. It is suggested that, at low viscosity, the ripples are capillary waves generated by the parametric instability excited by the membrane vibration, which is driven by the sound pressure. Atomization occurs whenever the membrane becomes so thin that the vibration is sufficiently intense. Buckling occurs when an existent equilibrium is unstable to a radial oscillation of the membrane because of the Bernoulli effect. The radiation stress at the rim of the flattened drop is also destabilizing and leads to horizontal expansion and subsequent breakup.

Lee, C. P.↗