Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacitance Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Recent Advancements in Electrical Capacitance Mass Gauging for Cryogenic PropellantTanks

The current lack of unsettled mass gauging is a key roadblock for many space activities, such as orbital refueling, missions to the Moon and Mars, and nuclear thermal and nuclear electric propulsion technologies. Liquid can form any one of an infinite number of configurations in microgravity, such as floating in globs or accumulating on tank surfaces in discontiguous volumes, or both. Capacitive sensing requires no moving parts and dissipates close to zero heat, making it an ideal candidate for cryogenic fluid mass gauging in settled and unsettled configurations. Capacitive sensing has a history of proven use in space propellant tanks, including tanks on the space shuttle, Saturn V, and the Apollo Lunar Excursion Module. Modern capacitive sensor technology allows using the entire tank as the capacitor volume by placing electrodes on the tank walls and propellant management surfaces. Capacitance is directly related to density, and therefore to mass for fixed volumes. In this presentation, we discuss the concepts behind whole-tank capacitance mass gauging and associated engineering challenges. We describe recent efforts to develop a micro-g unsettled cryogenic mass gauge using whole-tank capacitance sensing, including the development of test beds, electronics, and algorithms. We describe several mathematical processing techniques, including empirical-based averaging, electrical capacitance volume tomography, and spatial regularization. A modeling study, performed using settled configurations in gravity and no gravity, and with a set of 100 random fluid configurations, has indicated that spatial regularization, in which capacitance measurements are weighted to account for non-uniform electric fields, yields a mass fraction accuracy of 8% for any fluid configuration. Such a sensor is expected to operate in real time with a sampling frequency of at least 1 kHz.

cryogenic↗

Inductive Non-Contact Position Sensor

Optical hardware has been developed to measure the depth of defects in the Space Shuttle Orbiter's windows. In this hardware, a mirror is translated such that its position corresponds to the defect's depth, so the depth measurement problem is transferred to a mirror-position measurement problem. This is preferable because the mirror is internal to the optical system and thus accessible. Based on requirements supplied by the window inspectors, the depth of the defects needs to be measured over a range of 200 microns with a resolution of about 100 nm and an accuracy of about 400 nm. These same requirements then apply to measuring the position of the mirror, and in addition, since this is a scanning system, a response time of about 10 ms is needed. A market search was conducted and no sensor that met these requirements that also fit into the available housing volume (less than one cubic inch) was found, so a novel sensor configuration was constructed to meet the requirements. This new sensor generates a nearly linearly varying magnetic field over a small region of space, which can easily be sampled, resulting in a voltage proportional to position. Experiments were done with a range of inductor values, drive voltages, drive frequencies, and inductor shapes. A rough mathematical model was developed for the device that, in most aspects, describes how it operates and what electrical parameters should be chosen for best performance. The final configuration met all the requirements, yielding a small rugged sensor that was easy to use and had nanometer resolution over more than the 200-micron range required. The inductive position sensor is a compact device (potentially as small as 2 cubic centimeters), which offers nanometer-position resolution over a demonstrated range of nearly 1 mm. One of its advantages is the simplicity of its electrical design. Also, the sensor resolution is nearly uniform across its operational range, which is in contrast to eddy current and capacitive sensors whose sensitivity is dependent upon position.

Youngquist, Robert↗

Avoiding space robot collisions utilizing the NASA/GSFC tri-mode skin sensor

A capacitance based proximity sensor, the 'Capaciflector' (Vranish 92), has been developed at the Goddard Space Flight Center of NASA. We had investigated the use of this sensor for avoiding and maneuvering around unexpected objects (Mahalingam 92). The approach developed there would help in executing collision-free gross motions. Another important aspect of robot motion planning is fine motion planning. Let us classify manipulator robot motion planning into two groups at the task level: gross motion planning and fine motion planning. We use the term 'gross planning' where the major degrees of freedom of the robot execute large motions, for example, the motion of a robot in a pick and place type operation. We use the term 'fine motion' to indicate motions of the robot where the large dofs do not move much, and move far less than the mirror dofs, such as in inserting a peg in a hole. In this report we describe our experiments and experiences in this area.

Prinz, F. B. S.↗

Early Warning Signs

Developed under an SBIR contract with Goddard Space Flight Center, Jentek Sensors, Inc.'s GridStation Measurement System provides thermal spray coating thickness, porosity, and age degradation monitoring capability using comformable inductive and capacitative sensors and model-based grid measurement methods for data interpretation.

Source record↗

Predicting critical heat flux using localized sensing at invisible vapor-liquid interfaces

Predicting critical heat flux (CHF) in two-phase electronics cooling systems remains a significant challenge due to the sudden onset of boiling crisis and the difficulty in directly visualizing vapor-liquid interfaces. Existing sensing methods rely on lagging temperature measurements, optically accessible systems, or spatially averaged signals that cannot pinpoint CHF initiation at localized high-heat-flux regions. Here, we report a planar capacitive sensing approach that enables real-time, localized detection of vapor-liquid interface dynamics for CHF prediction in boiling heat transfer. The capacitive sensor exploits the dielectric constant difference between liquid and vapor phases to capture bubble nucleation, growth, and departure dynamics with a temporal resolution down to 2 ms. The capacitive sensing reveals distinct signals across boiling regimes: from high-frequency fluctuations during strong nucleate boiling to low-frequency fluctuations with increased amplitudes when approaching CHF. The multi-sensor array experiments demonstrate real-time localized sensing, where each sensor responds exclusively to boiling in its immediate vicinity without crosstalk from neighboring regions. This non-intrusive sensing approach provides predictive rather than lagging sensing signals of CHF occurrence, offering predictive diagnosis of two-phase liquid cooling for the thermal management of high-power-density electronics.

CHF↗

A figure control sensor for the Large Deployable Reflector (LDR)

A sensing and control system is required to maintain high optical figure quality in a segmented reflector. Upon detecting a deviation of the segmented surface from its ideal form, the system drives segment mounted actuators to realign the individual segments and thereby return the surface to its intended figure. When the reflector is in use, a set of figure sensors will determine positions of a number of points on the back surface of each of the reflector's segments, each sensor being assigned to a single point. By measuring the positional deviations of these points from previously established nominal values, the figure sensors provide the control system with the information required to maintain the reflector's optical figure. The optical lever, multiple wavelength interferometer, and electronic capacitive sensor, the most promising technologies for the development of the figure sensor, are illustrated. It is concluded that to select a particular implementation of the figure sensors, performance requirement will be refined and relevant technologies investigated further.

Bartman, R.↗

The trade-off characteristics of acoustic and pressure sensors for the NASP

Results of a trade study for the development of pressure and acoustic sensors for use on the National Aerospace Plane (NASP) are summarized. Pressure sensors are needed to operate to 100 psia; acoustic sensors are needed that can give meaningful information about a 200 dB sound pressure level (SPL) environment. Both sensors will have to operate from a high temperature of 2000 F down to absolute zero. The main conclusions of the study are the following: (1) Diaphragm materials limit minimum size and maximum frequency response attainable. (2) No transduction is available to meet all the NASP requirements with existing technology. (3) Capacitive sensors are large relative to the requirement, have limited resolution and frequency response due to noise, and cable length is limited to approximately 20 feet. (4) Eddy current sensors are large relative to the requirement and have limited cable lengths. (5) Fiber optic sensors provide the possibility for a small sensor, even though present developments do not exhibit that characteristic. The need to use sapphire at high temperature complicates the design. Present high temperature research sensors suffer from poor resolution. A significant development effort will be required to realize the potential of fiber optics. (6) Short-term development seems to favor eddy current techniques with the penalty of larger size and reduced dynamic range for acoustic sensors. (7) Long-term development may favor fiber optics with the penalties of cost, schedule, and uncertainty.

Winkler, Martin↗

Method and Apparatus for Non-Destructive Evaluation of Materials

Methods and apparatus for characterizing composite materials for manufacturing quality assurance (QA), periodic inspection during the useful life, or for forensic analysis/material testing. System are provided that relate eddy-current sensor responses to the fiber layup of a composite structure, the presence of impact damage on a composite structure with or without a metal liner, volumetric stress within the composite, fiber tow density, and other NDE inspection requirements. Also provided are systems that determine electromagnetic material properties and material dimensions of composite materials from capacitive sensor inspection measurements. These properties are related to the presence of buried defects in non-conductive composite materials, moisture ingress, aging of the material due to service or environmental/thermal exposure, or changes in manufacturing quality.

Goldfine, Neil J.↗

Method and Apparatus for Non-Destructive Evaluation of Materials

Methods and apparatus for characterizing composite materials for manufacturing quality assurance (QA), periodic inspection during the useful life, or for forensic analysis/material testing. System are provided that relate eddy-current sensor responses to the fiber layup of a composite structure, the presence of impact damage on a composite structure with or without a metal liner, volumetric stress within the composite, fiber tow density, and other NDE inspection requirements. Also provided are systems that determine electromagnetic material properties and material dimensions of composite materials from capacitive sensor inspection measurements. These properties are related to the presence of buried defects in non-conductive composite materials, moisture ingress, aging of the material due to service or environmental/thermal exposure, or changes in manufacturing quality.

Goldfine, Neil J.↗

High-efficiency frost and ice control via sensing-assisted nanovibrational slippery surfaces

Frost and ice accretions on surfaces pose persistent challenges across numerous industrial, residential and transportation systems. While various removal strategies exist, they often suffer from limited effectiveness or high energy consumption, such as frosting delay, ice crack generation, and Joule heating. Here, in this work, we report a novel integrated approach combining vibrational quasi-liquid surface (QLS) and capacitive sensing for efficient condensate, frost, and ice management. Compared to Joule heating, our approach does not rely on complete melting and evaporation for removal, resulting in 68% and 95% energy savings for frost and ice removal, respectively. Our QLS coating significantly reduces surface retention forces, achieving 91% and 87% less residual mass compared to hydrophilic surfaces for frost and ice removal through surface nanovibration, respectively. The integrated capacitive sensor provides real-time detection of different phase states, enabling on-demand removal in precise timeframes. This sensor-assisted approach showed 3.8 times lower energy consumption compared to conventional Joule heating for defrosting. This synergistic integration of surface engineering, nanovibration, and intelligent sensing represents a significant advancement in phase change processes, offering an energy-efficient solution for frost and ice mitigation in energy-intensive systems.

Shen, Yuchen [Univ. of Texas at Dallas, Richardson↗

Shuttle propellant loading instrumenation development

A continuous capacitance sensor was developed and an analog signal conditioner was evaluated to demonstrate the acceptability of these items for use in the space shuttle propellant loading system. An existing basic sensor concept was redesigned to provide capability for cryogenic operation, to improve performance, and to minimize production costs. Sensor development verification consisted of evaluation of sensor linearity, cryogenic performance, and stability during vibration. The signal conditioner evaluation consisted mainly of establishing the effects of the variations in temperature and cable parameters and evaluating the stability. A sensor linearity of 0.04 in. was achieved over most of the sensor length. The sensor instability caused by vibration was 0.04 percent. The cryogenic performance data show a maximum instability of 0.19 percent at liquid hydrogen temperature; a theoretical calibration can be computed a within 1 percent. The signal conditioner evaluation showed that, with temperature compensation, all error sources typically contribute much less than 1 percent. An estimate of the accuracy achievable with the sensor and signal conditioner shows an rss estimate of 0.75 in. for liquid oxygen and 1.02 in. for liquid hydrogen. These are approximately four times better than the shuttle requirements. Comparison of continuous sensor and discrete sensor performance show the continuous sensor to be significantly better when there is surface activity due to sloshing, boiling, or other disturbances.

Hamlet, J.↗

The experimental computer control of a two-dimensional hyperbolic system

The experimental computer control of a two-dimensional hyperbolic system is described. The system consists of a 5-foot gold-coated rubber membrane mounted on a circular cylindrical drum. Seven electrodes reside on a command surface located behind the membrane inside the drum. These electrodes served as capacitive sensors and electrostatic force actuators of transverse membrane deflection. The membrane was modelled as flat, isotropic and uniformly tensioned. Transverse membrane deflections were expanded in normal modes. Controllers regulating membrane deflection are designed using aggregation and design procedures based upon sensor and actuator influence functions. The resulting control laws are implemented on a minicomputer in two sets of experiments. The experimental study confirms the theoretically predicted behavior of the system, usefulness of the aggregation and design procedures, and the expectation that spillover can be made a beneficial source of damping in residual systems.

Yam, Y.↗

Magnetic bearings for cryogenic turbomachines

Magnetic bearings offer a number of advantages over gas bearings for the support of rotors in cryogenic turboexpanders and compressors. Their performance is relatively independent of the temperature or pressure of the process gas for a large range of conditions. Active magnetic bearing systems that use capacitive sensors have been developed for high speed compressors for use in cryogenic refrigerators. Here, the development of a magnetic bearing system for a miniature ultra high speed compressor is discussed. The magnetic bearing has demonstrated stability at rotational speeds exceeding 250,000 rpm. This paper describes the important features of the magnetic bearing and presents test results demonstrating its performance characteristics.

Iannello, Victor↗

Strain Gage Measurement System to Determine Cryogenic Propellant Tank Level

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult proposition. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. This paper describes a simple, but effective method to determine propellant volume by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a very good quality signal even during pressurization.

Figueroa, Fernando↗

Fiber-Optic Strain-Gage Tank Level Measurement System for Cryogenic Propellants

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult problem. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. These methods are designed to measure tank-level, but when the fluids are in supercritical state, the liquid-gas interface disappears. Furthermore, there is a need for a non-intrusive measurement system; that is, the sensors should not require tank modifications and/or disturb the fluids. This paper describes a simple, but effective method to determine propellant mass by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a much better quality signal across all regimes during an engine test. Experimental results also show that the use of fiber optic strain gages (FOSG) over classic foil strain gages extends the operation time (before the system becomes uncalibrated), and increases accuracy. Finally, a procedure is defined whereby measurements from the FOSG mounted on the tank supporting structure are compensated using measurements of a FOSG mounted on a reference plate and temperature measurements of the structure. Results describing the performance of a deployed system that measures tank level during propulsion tests are included.

Figueroa, Fernando↗

An extensometer for global measurement of bone strain suitable for use in vivo in humans

An axial extensometer able to measure global bone strain magnitudes and rates encountered during physiological activity, and suitable for use in vivo in human subjects, is described. The extensometer uses paired capacitive sensors mounted to intraosseus pins and allows measurement of strain due to bending in the plane of the extensometer as well as uniaxial compression or tension. Data are presented for validation of the device against a surface-mounted strain gage in an acrylic specimen under dynamic four-point bending, with square wave and sinusoidal loading inputs up to 1500 mu epsilon and 20 Hz, representative of physiological strain magnitudes and frequencies. Pearson's correlation coefficient (r) between extensometer and strain gage ranged from 0.960 to 0.999. Mean differences between extensometer and strain gage ranged up to 15.3 mu epsilon. Errors in the extensometer output were directly proportional to the degree of bending that occurs in the specimen, however, these errors were predictable and less than 1 mu epsilon for the loading regime studied. The device is capable of tracking strain rates in excess of 90,000 mu epsilon/s.

Non-NASA Center↗