NDE of advanced turbine engine components and materials by computed tomography

Computed tomography (CT) is an X-ray technique that provides quantitative 3D density information of materials and components and can accurately detail spatial distributions of cracks, voids, and density variations. CT scans of ceramic materials, composites, and engine components were taken and the resulting images will be discussed. Scans were taken with two CT systems with different spatial resolution capabilities. The scans showed internal damage, density variations, and geometrical arrangement of various features in the materials and components. It was concluded that CT can play an important role in the characterization of advanced turbine engine materials and components. Future applications of this technology will be outlined.

Yancey, R. N.↗

Thermoregulatory effects of caffeine ingestion during rest and exercise in men

Body temperatures and thermoregulatory responses were measured at rest and during submaximal exercise under normal ambient conditions in 11 aerobically-conditioned men (age = 29.2 +/- 6.2 yr, VO2(max) = 3.73 +/- 0.46 min(sup -1), relative body fat = 12.3 +/- 3.7 percent, mean +/- SD) with (CT) and without (NCT) the ingestion of 10 mg of caffeine per kg of body weight. Oxygen uptake (VO2), heart rate (HR), and rectal (T(sub re)) and mean skin (T-bar(sub sk)) temperatures were recorded for 100 minutes starting one minute after ingestion of caffeine or a placebo. Data were collected throughout 30 minutes of rest (sitting) and the following 70 minutes of sitting leg ergometer exercise using the same constant load (1,088 +/- 153 kgm/min) in both NCT and CT. The load resulted in a mean relative exercise intensity equal to approximately 68 percent of VO2(sub max). Skin heat conductance (H(sub sk)) and sweat rate were calculated. Two-way analysis of covariance revealed no significant (P greater than 0.05) differences between NCT and CT in VO2, HR, T(sub re), T-bar(sub sk), or H(sub sk). A dependent t-test indicated no significant difference between NCT and CT in sweat rate. Thus, a high level of caffeine ingestion has no detrimental effects on body temperatures and thermoregulatory responses during moderately heavy exercise in normal ambient conditions.

Dunagan, Nancy↗

Quantitative Computer Tomography for Determining Composition of Microgravity and Ground Based Solid Solutions

Advances in x-ray Computer Tomography (CT) have been led by the medical profession, and by evaluation of industrial products, particularly castings. Porosity can readily be determined as a function of the density of a material, and CT is thus an industrially important NDE tool. Providing high purity, 100% dense standards of pure elements and compounds can be fabricated, the composition of solid solution alloys can be determined by measuring the CT number, which is a function of the absorption of the sample. Average densities across slices 1 mm thick can generally be determined to better than 1 percent. With present technology this spatial sensitivity is less than ideal, but important benefits can nevertheless be obtained by using CT, particularly single crystals, prior to making any destructive assault upon the sample. The sample can in fact be examined prior to removal from the mold within which it has been grown and, in the cases of microgravity flight samples, before removal from the cartridge assembly. This greatly assists the researcher in the characterization of the products, particularly as a guide to cutting and sampling. Examples of work with germanium-silicon alloys and mercury cadmium telluride taken with a radioactive cobalt source will be demonstrated.

Gillies, D. C.↗

MOLA Topography of the Crustal Dichotomy Boundary Zone, Mars

Mars Orbiter Laser Altimeter (MOLA) profiles frequently cross the crustal dichotomy boundary where the transition zone (TZ) between cratered highland terrain (CT) and lowland smooth plains (SP) is marked by mesas and knobby terrain. The detailed topographic character of the boundary zone is longitudinally variable, as is the geomorphology of the TZ. Some portions of the boundary are associated with an outer ring of the Utopia impact basin; MOLA topography is consistent with this. The regional character of the boundary topography is a 2-4 km step function from nearly flat SP to almost as flat CT. This rise has a regional slope of 1-2 degrees, 50-100 times that of the Cr and SP away from TZ, which suggests a significant change in crustal properties (thickness, composition or both) across the TZ. The overall topography is very similar to that at some passive continent-oceanic crustal margins on the Earth, with the seafloor allowed to adjust upward after removal of the overlying water. A possible temporal constraint on the CT/SP elevation difference comes from two MOLA profiles which pass through two large (150 km diameter) craters located at the boundary in Aeolis. The N and S rims of the more degraded crater are at the same elevation; north of the N rim the topography drops by greater than 2 km to the floor of the TZ. This crater predates the elevation offset between CT and TZ floor. The better preserved crater (Gale) has a N rim 2 km lower than its S rim, and appears to have been emplaced on a pre-existing regional slope of about I degree. Gale probably post- dates the elevation difference between CT and TZ floor. Based on the stratigraphy of the units in which these craters are found, the elevation difference appears to have been in place in the Mid to Late Noachian.

Frey, Herbert V.↗

Computer Tomography Analysis of Fastrac Composite Thrust Chamber Assemblies

Computed tomography (CT) inspection has been integrated into the production process for NASA's Fastrac composite thrust chamber assemblies (TCAs). CT has been proven to be uniquely qualified to detect the known critical flaw for these nozzles, liner cracks that are adjacent to debonds between the liner and overwrap. CT is also being used as a process monitoring tool through analysis of low density indications in the nozzle overwraps. 3d reconstruction of CT images to produce models of flawed areas is being used to give program engineers better insight into the location and nature of nozzle flaws.

Beshears, Ronald D.↗

Three Dimensional Characterization of the Mundrabilla Meteorite

The differentiated meteorite, Mundrabilla, exhibits a rare structure of primary kamacite/taenite, and at least 25 volume % of sulfide (troilite and daubreelite). The structure has been investigated in three dimensions using the technique of gamma-ray computed tomography (CT) with a radioactive (60)Co isotope as the source of the flux. Using CT, a 50 kg slab with dimensions 12.6 x 8.2 x approx. 70 cm has been sectioned at 1 mm intervals over 50 cm length, and the three dimensional structure is at present being evaluated. These data revealed, in addition to the metallic and troilite-rich phases, the presence and distribution of graphite-rich cones (up to 5 cm long), and small (1-2 mm), low density particles. The graphite cones are readily visible on the surfaces of many of the sections of Mundrabilla, while the smaller phases have a density (determined from CT) of approximately 2.9 g/cc, and are assumed to be silicate inclusions. CT spatial resolution is not adequate to elucidate the shapes of these particles. One can only state that they show no directionality and are equiaxed.

Gillies, Donald C.↗

Modeling of polychromatic attenuation using computed tomography reconstructed images

This paper presents a procedure for estimating an accurate model of the CT imaging process including spectral effects. As raw projection data are typically unavailable to the end-user, we adopt a post-processing approach that utilizes the reconstructed images themselves. This approach includes errors from x-ray scatter and the nonidealities of the built-in soft tissue correction into the beam characteristics, which is crucial to beam hardening correction algorithms that are designed to be applied directly to CT reconstructed images. We formulate this approach as a quadratic programming problem and propose two different methods, dimension reduction and regularization, to overcome ill conditioning in the model. For the regularization method we use a statistical procedure, Cross Validation, to select the regularization parameter. We have constructed step-wedge phantoms to estimate the effective beam spectrum of a GE CT-I scanner. Using the derived spectrum, we computed the attenuation ratios for the wedge phantoms and found that the worst case modeling error is less than 3% of the corresponding attenuation ratio. We have also built two test (hybrid) phantoms to evaluate the effective spectrum. Based on these test phantoms, we have shown that the effective beam spectrum provides an accurate model for the CT imaging process. Last, we used a simple beam hardening correction experiment to demonstrate the effectiveness of the estimated beam profile for removing beam hardening artifacts. We hope that this estimation procedure will encourage more independent research on beam hardening corrections and will lead to the development of application-specific beam hardening correction algorithms.

NASA Discipline Musculoskeletal↗

Muscle fatigue in frog semitendinosus: alterations in contractile function

The purpose of this study was to characterize the contractile properties of the frog semitendinosus (ST) muscle before and during recovery from fatigue, to relate the observed functional changes to alterations in specific steps in the crossbridge model of muscle contraction, and to determine how fatigue affects the force-frequency relationship. The frog ST (22 degrees C) was fatigued by direct electrical stimulation with 100-ms 150-Hz trains at 1/s for 5 min. The fatigue protocol reduced peak twitch (Pt) and tetanic (Po) force to 32 and 8.5% of initial force, respectively. The decline in Pt was less than Po, in part due to a prolongation in the isometric contraction time (CT), which increased to 300% of the initial value. The isometric twitch duration was greatly prolonged as reflected by the lengthened CT and the 800% increase in the one-half relaxation time (1/2RT). Both Pt and Po showed a biphasic recovery, a rapid initial phase (2 min) followed by a slower (40 min) return to the prefatigue force. CT and 1/2RT also recovered in two phases, returning to 160 and 265% of control in the first 5 min. CT returned to the prefatigue value between 35 and 40 min, whereas even at 60 min 1/2RT was 133% of control. The maximal velocity of shortening, determined by the slack test, was significantly reduced [from 6.7 +/- 0.5 to 2.5 +/- 0.4 optimal muscle length/s] at fatigue. The force-frequency relationship was shifted to the left, so that optimal frequency for generating Po was reduced.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Musculoskeletal↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗

Space Shuttle Transportation (Roll-Out) Loads Diagnostics

The Space Transportation System (STS) consists of three primary components; an Orbiter Vehicle, an External Fuel Tank, and two Solid Rocket Boosters. The Orbiter Vehicle and Solid Rocket Boosters are reusable components, and as such, they are susceptible to durability issues. Recently, the fatigue load spectra for these components have been updated to include load histories acquired during the rollout phase of the STS processing for flight. Using traditional program life assessment techniques, the incorporation of these "rollout" loads produced unacceptable life estimates for certain Orbiter structural members. As a result, the Space Shuttle System Engineering and Integration Office has initiated a program to re-assess the method used for developing the "rollout" loads and performing the life assessments. In the fall of 2003 a set of tests were preformed to provide information to either validate existing load spectra estimation techniques or generate new load spectra estimation methods. Acceleration and strain data were collected from two rollouts of a partial-stack configuration of the Space Shuttle. The partial stack configuration consists of two Solid Rocket Boosters tied together at the upper External Tank attachment locations mounted on the Mobile Launch Platform carried by a Crawler Transporter (CT). In the current analysis, the data collected from this test is examined for consistency in speed, surface condition effects, and the characterization of the forcing function. It is observed that the speed of the CT is relatively stable. The dynamic response acceleration of the partial-stack is slightly sensitive to the surface condition of the road used for transport, and the dynamic response acceleration of the partial-stack generally increases as the transport speed increases. However, the speed sensitivity is dependent on the measurement location. Finally, the character of the forcing function is narrow-banded with the primary drivers being harmonics of two CT speed dependent excitations. One source is an excitation due to the CT treads striking the road surface, and the second is unknown.

Elliott, Kenny B.↗

X-Ray Computed Tomography Inspection of the Stardust Heat Shield

The "Stardust" heat shield, composed of a PICA (Phenolic Impregnated Carbon Ablator) Thermal Protection System (TPS), bonded to a composite aeroshell, contains important features which chronicle its time in space as well as re-entry. To guide the further study of the Stardust heat shield, NASA reviewed a number of techniques for inspection of the article. The goals of the inspection were: 1) to establish the material characteristics of the shield and shield components, 2) record the dimensions of shield components and assembly as compared with the pre-flight condition, 3) provide flight infonnation for validation and verification of the FIAT ablation code and PICA material property model and 4) through the evaluation of the shield material provide input to future missions which employ similar materials. Industrial X-Ray Computed Tomography (CT) is a 3D inspection technology which can provide infonnation on material integrity, material properties (density) and dimensional measurements of the heat shield components. Computed tomographic volumetric inspections can generate a dimensionally correct, quantitatively accurate volume of the shield assembly. Because of the capabilities offered by X-ray CT, NASA chose to use this method to evaluate the Stardust heat shield. Personnel at NASA Johnson Space Center (JSC) and Lawrence Livermore National Labs (LLNL) recently performed a full scan of the Stardust heat shield using a newly installed X-ray CT system at JSC. This paper briefly discusses the technology used and then presents the following results: 1. CT scans derived dimensions and their comparisons with as-built dimensions anchored with data obtained from samples cut from the heat shield; 2. Measured density variation, char layer thickness, recession and bond line (the adhesive layer between the PICA and the aeroshell) integrity; 3. FIAT predicted recession, density and char layer profiles as well as bondline temperatures Finally suggestions are made as to future uses of this technology as a tool for non-destructively inspecting and verifying both pre and post flight heat shields.

McNamara, Karen M.↗

Metallurgical Design and Development of NASA Crawler/Transporter Tread Belt Shoe Castings

The NASA Crawler/Transporters (CT-1 and CT-2) used to transport the Space Shuffles are one of the largest tracked vehicles in existence today. Two of these machines have been used to move space flight vehicles at Kennedy Space Center since the Apollo missions of the 1960's and relatively few modifications have been made to keep them operational. In September of 2003 during normal Crawler/Transporter operations cracks were observed along the roller pad surfaces of several tread belt shoes. Further examination showed 20 cracked shoes on CT-1 and 40 cracked shoes on CT-2 and a formal failure analysis investigation was undertaken while the cracked shoes were replaced. Six shoes were cross-sectioned with the fracture surfaces exposed and it was determined that the cracks were due to fatigue that initiated on the internal casting web channels at pre-existing casting defects and propagated through thickness both transgranularly and intergranularly between internal shrinkage cavities, porosity, and along austenitic and ferritic grain boundaries. The original shoes were cast during the 1960's using a modified 861330 steel with slightly higher levels of chromium, nickel and molybdenum followed by heat treatment to achieve a minimum tensile strength of 11 Oksi. Subsequent metallurgical analysis of the tread belt shoes after multiple failures showed excessive internal defects, alloy segregation, a nonuniform ferritic/ bainitic/martensitic microstructure, and low average tensile properties indicative of poor casting and poor heat-treatment. As a result, NASA funded an initiative to replace all of the tread belt shoes on both crawler/transporters along with a redesign of the alloy, manufacturing, and heat-treatment to create a homogeneous cast structure with uniform mechanical and metallurgical properties. ME Global, a wholly owned subsidiary of ME Elecmetal based in Minneapolis, MN was selected as manufacturing and design partner to develop the new shoes and this paper describes the research, development, and manufacturing that resulted in the successful delivery of 1044 new Crawler/Transporter tread belt shoes all meeting rigid metallurgical and mechanical design criteria derived from finite element modeling of the stress loads required for safe space shuttle transport.

Parker, Donald S.↗

Comparison of Intralaminar and Interlaminar Mode-I Fracture Toughness of Unidirectional IM7/8552 Graphite/Epoxy Composite

The intralaminar and interlaminar mode-I fracture-toughness of a unidirectional IM7/8552 graphite/epoxy composite were measured using compact tension (CT) and double cantilever beam (DCB) test specimens, respectively. Two starter crack geometries were considered for both the CT and DCB specimen configurations. In the first case, starter cracks were produced by 12.5 micron thick, Teflon film inserts. In the second case, considerably sharper starter cracks were produced by fatigue precracking. For each specimen configuration, use of the Teflon film starter cracks resulted in initially unstable crack growth and artificially high initiation fracture-toughness values. Conversely, specimens with fatigue precracks exhibited stable growth onset and lower initiation fracture toughness. For CT and DCB specimens with fatigue precracks, the intralaminar and interlaminar initiation fracture toughnesses were approximately equal. However, during propagation, the CT specimens exhibited more extensive fiber bridging, and rapidly increasing R-curve behavior as compared to the DCB specimens. Observations of initiation and propagation of intralaminar and interlaminar fracture, and the measurements of fracture toughness, were supported by fractographic analysis using scanning electron microscopy.

Czabaj, Michael W.↗

Software Method for Computed Tomography Cylinder Data Unwrapping, Re-slicing, and Analysis

A software method has been developed that is applicable for analyzing cylindrical and partially cylindrical objects inspected using computed tomography (CT). This method involves unwrapping and re-slicing data so that the CT data from the cylindrical object can be viewed as a series of 2D sheets (or flattened onion skins ) in addition to a series of top view slices and 3D volume rendering. The advantages of viewing the data in this fashion are as follows: (1) the use of standard and specialized image processing and analysis methods is facilitated having 2D array data versus a volume rendering; (2) accurate lateral dimensional analysis of flaws is possible in the unwrapped sheets versus volume rendering; (3) flaws in the part jump out at the inspector with the proper contrast expansion settings in the unwrapped sheets; and (4) it is much easier for the inspector to locate flaws in the unwrapped sheets versus top view slices for very thin cylinders. The method is fully automated and requires no input from the user except proper voxel dimension from the CT experiment and wall thickness of the part. The software is available in 32-bit and 64-bit versions, and can be used with binary data (8- and 16-bit) and BMP type CT image sets. The software has memory (RAM) and hard-drive based modes. The advantage of the (64-bit) RAM-based mode is speed (and is very practical for users of 64-bit Windows operating systems and computers having 16 GB or more RAM). The advantage of the hard-drive based analysis is one can work with essentially unlimited-sized data sets. Separate windows are spawned for the unwrapped/re-sliced data view and any image processing interactive capability. Individual unwrapped images and un -wrapped image series can be saved in common image formats. More information is available at http://www.grc.nasa.gov/WWW/OptInstr/ NDE_CT_CylinderUnwrapper.html.

Roth, Don J.↗

Reflection-dominated Nuclear X-Ray Emission in the Early-Type Galaxy ESO 565 G019

We present the discovery of a reflection-dominated active galactic nucleus (AGN) in the early-type radio-quietgalaxy ESO 565G019 with Suzaku and SwiftBurst Alert Telescope. The source X-ray spectrum below 10 keVis characteristic of other Compton-thick (CT) AGNs, clearly showing an inverted continuum and prodigiousfluorescence iron emission above 3 keV. A Compton shoulder to the neutral Fe K line also appears to be present.There is evidence for long-term hard X-ray flux variability that we associate with changes in the intrinsic AGNpower law. More of such reflection-dominated AGNs should be uncovered in the near future with the increasedsensitivity of ongoing and new hard X-ray surveys. ESO 565G019 is hosted in an early-type galaxy whosemorphology has been variously classified as either type E or type S0. Only about 20 bona fide CT-AGNs have been identified in the local universe so far, and all exist in host galaxies with late Hubble types (S0 or later). CT columns of nuclear obscuring gas are uncommon in early-type galaxies in the local universe, so confirmation of the exact morphological class of ESO 565G019 is important. Infrared photometry also shows the presence of largequantities of cool dust in the host, indicative of significant ongoing star formation. ESO 565G019 may be the firstidentified local example of minor-merger-driven CT-AGN growth in an early-type host, or may be the result ofinteraction with its neighboring galaxy ESO 565G018 in a wide pair.

comparison↗

Mineralogy of the Greenheugh Pediment and Underlying Murray Formation from the Mars Science Laboratory CheMin Instrument

The Mars Science Laboratory Curiosity rover has been investigating a sequence of ancient fluvio-lacustrine and eolian units in Gale crater. For much of the mission, Curiosity has studied the fluvio-lacustrine deposits of the Murray formation. Curiosity has also studied the ancient eolian Stimson formation in a few locations, which unconformably overlies the Murray fm. The Stimson formation was previously studied at the Naukluft and Emerson Plateaus and recently studied at the Greenheugh pediment capping unit. The Curiosity science team also investigated the Murray formation directly underlying the pediment. Curiosity drilled the “Edinburgh” target within the pediment capping unit and the “Hutton” target in the Murray formation near the contact with the pediment and delivered these materials to the CheMin X-ray diffractometer to characterize bulk mineralogy. Edinburgh contains abundant plagioclase, pyroxene, magnetite, olivine, and X-ray amorphous materials, with 10 wt.% smectite and minor sanidine. The mineralogy of the Stimson at Greenheugh is distinct from the mineralogy of the Stimson at Naukluft and Emerson because previous Stimson targets did not contain olivine or clay minerals. This suggests sediments in the pediment may have a different source and/or different aqueous alteration history than those from Naukluft and Emerson. Hutton contains abundant plagioclase, pyroxene, magnetite, and X-ray amorphous materials, 6 wt.% smectite, and minor cristobalite, opal-CT, sanidine, hematite, fluorapatite, and anhydrite. Other Murray targets in the surrounding Glen Torridon region that are farther from the pediment contact contain ~30 wt.% smectite and lack cristobalite and opal-CT. Cristobalite and/or opal-CT are present in a few other targets elsewhere along the traverse, including the top of the nearby Vera Rubin ridge and the top of the Pahrump Hills outcrop. Stimson overlies the Pahrump Hills, and, based on projections of the pediment slope, the Stimson may have overlain Vera Rubin ridge. The proximity of the low-smectite and cristobalite- and/or opal-CT-bearing outcrops to the contact between the Murray and Stimson suggests the contact provided a conduit for diagenetic fluids that altered clay minerals and formed crystalline and paracrystalline silica.

E. B. Rampe↗

Assessment of Segmentation-Induced Deviations of Porosity Metrics in Powder Bed Fusion Additively Manufactured Components

Post processing X-ray computational tomography (CT) inspection data for additively manufactured (AM) components can induce deviations in defect quantification, affecting subsequent fatigue and failure predictions. To assess the influence and potential impact of segmentation-induced measurement deviations, this paper applies several segmentation techniques to X-ray CT data for powder bed fusion Ti-6Al-4V specimens exhibiting porosity conditions. X-ray CT reconstructions were segmented with varying techniques including Otsu’s thresholding, random forest, k-nearest neighbors, and the multilayer perceptron. Metrics such as pore size and global porosity were compared for internal validity. Then, top-down X-ray CT measurements of surface-breaking porosity were compared to optical profilometry for cross-validation.

Data fusion↗

Fatigue crack growth in a unidirectional SCS-6/Ti-15-3 composite

An investigation was conducted to characterize and model the fatigue crack growth (FCG) behavior of a SCS-6/Ti-15-3 metal matrix composite. Part of the study was conducted using a fatigue loading stage mounted inside a scanning electron microscope (SEM). This unique facility allowed high magnification viewing of the composite fatigue processes and measurement of the near crack tip displacements. The unidirectional composite was tested in the (0)8 (i.e., longitudinal) and (90)8 (i.e., transverse) orientations. For comparison purposes unreinforced matrix material produced by the identical process as the reinforced material was also tested. The results of the study reveal that the fatigue crack growth behavior of the composite is a function of specimen geometry, fiber orientation and the interaction of local stress fields with the highly anisotropic composite. In the case of (0)8 oriented single edge notch (SEN) specimens and (90)8 oriented compact tension (CT) specimens, the crack growth was normal to the loading direction. However, for the (0)8 CT specimens the crack grew mostly parallel to the loading and the fiber direction. The unusual fatigue behavior of the (0)8 CT specimens was attributed to the specimen geometry and the associated high tensile bending stresses perpendicular to the fiber direction. These stresses resulted in preferential cracking in the weak interface region perpendicular to the fiber direction. The interface region, and in particular the carbon coating surrounding the fiber proved to be the composites weakest link. In the (0)8 SEN the crack growth was confined to the matrix leaving behind unbroken fibers which bridged the cracked surfaces. As the crack grew longer, more fibers bridged the crack resulting in a progressive decrease in the crack growth rates and eventual crack arrest. The actual near crack tip displacement measurements were used in a proposed formulation for a bridging-corrected effective crack driving force, delta K(sub eff). This parameter was able to account for most of the experienced bridging and correlated the (0)8 SEN fatigue crack growth data reasonably well.

Kantzos, Peter↗