At least 73 records · Page 4

Forced convection heat transfer to air/water vapor mixtures

Heat transfer coefficients were measured using both dry air and air/water vapor mixtures in the same forced convection cooling test rig (jet array impingement configurations) with mass ratios of water vapor to air up to 0.23. The primary objective was to verify by direct experiment that selected existing methods for evaluation of viscosity and thermal conductivity of air/water vapor mixtures could be used with confidence to predict heat transfer coefficients for such mixtures using as a basis heat transfer data for dry air only. The property evaluation methods deemed most appropriate require as a basis a measured property value at one mixture composition in addition to the property values for the pure components.

Richards, D. R.↗

Testing Bearing Balls For Ignition In Liquid Oxygen

Inexpensive, safe apparatus built to test cooling by, ignition in, and nucleate boiling to film boiling of liquid oxygen flowing around ball bearings. Provides for heating of bearing specimens, direct observations, and measurements of temperatures and temperature distributions by thermocouples and infrared sensors. Used to evaluate suitability of various materials and surface treatments for ball bearings in high-pressure liquid-oxygen turbopumps. Ball rests in fixture while liquid oxygen flows around it. Flow reversed so observer or infrared sensor can view phenomena on trailing or leading side of ball.

Wagner, William R.↗

Cooling Characteristics of a 2-Row Radial Engine

This report presents the results of cooling tests conducted on a calibrated GR-1535 Pratt and Whitney Wasp, Jr. Engine installed in a Vought X04U-2 airplane. The tests were made in the NACA full-scale tunnel at air speeds from 70 to 120 miles per hour, at engine speeds from 1,500 to 2,600 r.p.m., and at manifold pressures from 19 to 33 inches of mercury absolute. A Smith controllable propeller was used to facilitate obtaining the different combinations of engine speed, power, and manifold pressure.

Schey, Oscar W↗

A Joint NICER and XMM-Newton View of the "Magnificent" Thermally Emitting X-ray Isolated Neutron Star RX J1605.3+3249

Thermally emitting X-ray isolated neutron stars (NSs) represent excellent targets for testing cooling surface emission and atmosphere models, which are used to infer the physical parameters of the NS. Among the seven known members of this class, RXJ1605.3+3249 is the only one that still lacks confirmation of its spin period. Here we analyze NICER and XMM-Newton observations of RXJ1605.3+3249, in order to address its timing and spectral behavior. Contrary to a previous tentative detection, but in agreement with the recent work by Pires et al., we find no significant pulsation with a pulsed fraction higher than 1.3% (3σ) for periods above 150 ms. We also find a limit of 2.6% for periods above 2 ms, despite searches in different energy bands. The X-ray spectrum can be fit by either a double-blackbody model or by a single-temperature magnetized atmosphere model, both modified by a Gaussian absorption line at ∼0.44 keV. The origin of the absorption feature as a proton cyclotron line or as an atomic transition in the NS atmosphere is discussed. The predictions of the best-fit X-ray models extended to IR, optical, and UV bands, are compared with archival data. Our results are interpreted in the framework of a fallback disk scenario.

Christian Malacaria↗

Experimental solar heating-cooling system model tests of a full-scale building system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable - heating and/or cooling load of a building, collected solar energy - with experimental equipment. The system model was based on the loads and components used in the Solar Building Test Facility (SBTF) which includes a 1394 square meter solar collector field, at NASA-Langley. Operations covered 5 continuous days under summer conditions. For the system model, up to 55% of the simulated collected solar energy was used for the building load. This amount constituted 35% of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, 75% of the collected solar energy would be used. This amount would supply approximately 50% of the building cooling load.

Namkoong, D.↗

High-Aspect-Ratio Cooling Channel Concept Tested in Lewis' Rocket Engine Test Facility

Rocket combustion chamber walls are exposed to the high-temperature environment caused by the combustion of propellants. Even with the walls actively cooled by the fuel, the hot gases can deteriorate the walls severely and limit any possibility for reusing the combustion chamber. For many years, the NASA Lewis Research Center has performed subscale investigations of potential improved cooling concepts to extend the life and reliability of the combustion chamber. Results from previous subscale tests have shown that, by increasing the coolant channel height-to-width aspect ratio, the rocket combustion chamber hot gas side wall temperature can be reduced by as much as 28 percent, without an increase in the coolant pressure drop. Recently, a series of experiments were completed in Lewis' Rocket Engine Test Facility (RETF) to validate the benefits of high aspect ratio cooling channels with a high-pressure, contoured rocket combustion chamber.

Source record↗

Effect of cooling-hole geometry on aerodynamic performance of a film-cooled turbine vane tested with cold air in a two-dimensional cascade

The effect of the orientation and cooling-hole size on turbine-vane aerodynamic losses was evaluated. The contribution of individual vane regions to the overall effect was also investigated. Test configurations were based upon a representative configuration having 45 spanwise rows of holes spaced about the entire vane profile. Nominal hole diameters of 0.0254 and 0.0356 cm and nominal hole orientations of 35 deg, 45 deg, and 55 deg from the local vane surface and 0 deg, 45 deg, and 90 deg from the main-stream flow direction were investigated. Flow conditions and aerodynamic losses were determined by vane-exit surveys of total pressure, static pressure, and flow angle.

Kline, J. F.↗

Comparison of heat transfer characteristics of three cooling configurations for air-cooled turbine vanes tested in a turbojet engine

A comparison was made of the heat transfer characteristics of three air cooled vanes. The vanes incorporated cooling schemes such as impingement cooling, film cooling, and convection cooling with and without extended surfaces. A redesign study was made for two vanes to improve the cooling effectiveness. An average impingement heat transfer coefficient was calculated on the bases of experimentally determined temperatures at the leading edge and a one dimensional heat transfer calculation. This heat transfer coefficient was compared with existing impingement heat transfer correlations.

Yeh, F. C.↗

Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

Rhodes, Richard↗

Comparative study of patches for liquid cooled garments.

Tests were performed on 12 cooling patches of various designs to establish criteria for the evaluation of their performance in liquid-cooled suits in industrial, military and aerospace applications. The thermal effectiveness value was 0.088 for patch designs with a double spiral flow pattern, and 0.075 for patch designs with a parallel flow pattern. The ratio of thermal energy transfer rate to cooling-medium pumping power requirement is indicated as the prime performance characteristic to be considered in the selection and rating of cooling patches.

Shitzer, A.↗

Design of Refractory Metal Heat Pipe Life Test Environment Chamber, Cooling System, and Radio Frequency Heating System

A series of 16 Mo-44.5%Re alloy/sodium heat pipes will be experimentally tested to examine heat pipe aging. To support this evaluation, an environmental test chamber and a number of auxiliary subsystems are required. These subsystems include radio frequency (RF) power supplies/inductive coils, recirculation water coolant loops, and chamber gas conditioning. The heat pipes will be grouped, based on like power and gas mixture requirements, into three clusters of five units each, configured in a pentagonal arrangement. The highest powered heat pipe will be tested separately. Test chamber atmospheric purity is targeted at <0.3 ppb oxygen at an approximate operating pressure of 76 torr (.1.5 psia), maintained by active purification (oxygen level is comparable to a 10(exp -6) torr environment). Treated water will be used in two independent cooling circuits to remove .85 kW. One circuit will service the RF hardware while the other will maintain the heat pipe calorimetry. Initial procedures for the startup and operation of support systems have been identified. Each of these subsystems is outfitted with a variety of instrumentation, integrated with distributed real-time controllers and computers. A local area network provides communication between all devices. This data and control network continuously monitors the health of the test hardware, providing warning indicators followed by automatic shutdown should potentially damaging conditions develop. During hardware construction, a number of checkout tests.many making use of stainless steel prototype heat pipes that are already fabricated.will be required to verify operation.

Martin, J. J.↗

An oxidation and erosion test facility for cooled panels

The Panel Oxidation and Erosion Testbed (POET) facility under construction at GASL to provide the required test environment is described. The POET facility comprises three major element including a vitiated air heater, a supersonic nozzle, and a test section. A hydrogen-fueld vitiated air heater will provide the oxidizing and erosive environment. The flow through the test section characterized by low supersonic speed and Mach number of 1.4 will maximize the local heat transfer rate and the local surface shear stress.

Swartwout, W. H.↗

Extension of similarity test procedures to cooled engine components with insulating ceramic coatings

Material thermal conductivity was analyzed for its effect on the thermal performance of air cooled gas turbine components, both with and without a ceramic thermal-barrier material, tested at reduced temperatures and pressures. The analysis shows that neglecting the material thermal conductivity can contribute significant errors when metal-wall-temperature test data taken on a turbine vane are extrapolated to engine conditions. This error in metal temperature for an uncoated vane is of opposite sign from that for a ceramic-coated vane. A correction technique is developed for both ceramic-coated and uncoated components.

Gladden, H. J.↗

Application of Simulated Reactivity Feedback in Nonnuclear Testing of a Direct-Drive Gas-Cooled Reactor

Nonnuclear testing can be a valuable tool in the development of an in-space nuclear power or propulsion system. In a nonnuclear test facility, electric heaters are used to simulate heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response and response characteristics, and assess potential design improvements with a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE 100a heat pipe cooled, electrically heated reactor and heat exchanger hardware. This Technical Memorandum discusses the status of the planned dynamic test methodology for implementation in the direct-drive gas-cooled reactor testing and assesses the additional instrumentation needed to implement high-fidelity dynamic testing.

Bragg-Sitton, S. M.↗