Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COOLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cooling Effectiveness Measurements for Air Film Cooling of Thermal Barrier Coated Surfaces in a Burner Rig Environment Using Phosphor Thermometry

While the effects of thermal barrier coating (TBC) thermal protection and air film cooling effectiveness are usually studied separately, their contributions to combined cooling effectiveness are interdependent and are not simply additive. Therefore, combined cooling effectiveness must be measured to achieve an optimum balance between TBC thermal protection and air film cooling. In this investigation, surface temperature mapping was performed using recently developed Cr-doped GdAlO3 phosphor thermometry. Measurements were performed in the NASA GRC Mach 0.3 burner rig on a TBC-coated plate using a scaled up cooling hole geometry where both the mainstream hot gas temperature and the blowing ratio were varied. Procedures for surface temperature and cooling effectiveness mapping of the air film-cooled TBC-coated surface are described. Applications are also shown for an engine component in both the burner rig test environment as well as an engine afterburner environment. The effects of thermal background radiation and flame chemiluminescence on the measurements are investigated, and advantages of this method over infrared thermography as well as the limitations of this method for studying air film cooling are discussed.

air film cooling↗

Role of convective mixing and evaporative cooling in shallow convection: Convective Mixing and Evaporative Cooling

Large-eddy simulations of shallow convection are used to evaluate the role of convective mixing and evaporative cooling in the vertical transport of mass, heat, and moisture in nonprecipitating shallow convection. Evaporative cooling is found to increase mass flux and the magnitude of heat and moisture fluxes, comparing twin large-eddy simulations with either suppressed or active evaporative cooling. Nonetheless, subsiding shells transport mass downward even when evaporative cooling is suppressed, emphasizing that evaporative cooling is not the primary cause of existence of subsiding shells and accompanied buoyancy reversal. Instead, vertical convective mixing is found to be the primary reason of buoyancy reversal. Evaporative cooling yet accelerates downdrafts (updrafts) in the shell (cloudy) regions as well as increases the cloud cover in the lower cloud layer. The cloudy regions are more humid, and the liquid water potential temperature is lower compared to the evaporative-cooling-suppressed experiment. The primary effect of evaporative cooling is thus to increase the updraft core anomalies, thus enhancing vertical turbulent fluxes.

54 ENVIRONMENTAL SCIENCES↗

Effect of Cooling Rate on Microsegregation During Solidification of Superalloy INCONEL 718 Under Slow-Cooled Conditions

The solidification sequence, microstructural evolution, solid-liquid interface variation, interdendritic segregation, and elemental distribution of as-cast IN718 alloy at three slow-cooling rates (5, 10, and 20 °C/min) were investigated by differential scanning calorimetry (DSC), confocal laser scanning microscopy (CLSM), optical microscopy (OM), field-emission scanning electron microscopy (FESEM), and electron-probe microanalysis (EPMA) techniques. The results indicate that as the cooling rate decreases, the constitutional supercooling at the solidification front affects the solid-liquid interface more significantly, and the size and quantity of the Laves phase increase. However, the composition of the Laves phase is insensitive to the cooling rate in the range of conditions studied here. In dendrite core, the contents of Ni, Cr, Fe, and Al follow a slight downward trend with an increasing cooling rate, whereas the Nb, Mo, and Ti contents show an upward trend. Additionally, Mo shows a stronger propensity to segregate under slow-cooling conditions because its effective partition coefficient almost linearly decreased with decreasing cooling rate, which is same as Nb. Using the parameters experimentally determined in this study and the Clyne–Kurz equation, we achieved reasonable agreement between the calculated and measured liquid composition change during the solidification process at different cooling rates. All experimental and theoretical programs in this research were undertaken with the aim of gaining further understanding of the microsegregation behaviors in large-scale IN718 ingots, whose cooling rates are within a lower range.

36 MATERIALS SCIENCE↗

EVERY BCG WITH A STRONG RADIO AGN HAS AN X-RAY COOL CORE: IS THE COOL CORE-NONCOOL CORE DICHOTOMY TOO SIMPLE?

The radio active galactic nucleus (AGN) feedback in X-ray cool cores has been proposed as a crucial ingredient in the evolution of baryonic structures. However, it has long been known that strong radio AGNs also exist in 'noncool core' clusters, which brings up the question whether an X-ray cool core is always required for the radio feedback. In this work, we present a systematic analysis of brightest cluster galaxies (BCGs) and strong radio AGNs in 152 groups and clusters from the Chandra archive. All 69 BCGs with radio AGN more luminous than 2 x 10{sup 23} W Hz{sup -1} at 1.4 GHz are found to have X-ray cool cores. BCG cool cores can be divided into two classes: the large cool core (LCC) class and the corona class. Small coronae, easily overlooked at z > 0.1, can trigger strong heating episodes in groups and clusters, long before LCCs are formed. Strong radio outbursts triggered by coronae may destroy embryonic LCCs and thus provide another mechanism to prevent the formation of LCCs. However, it is unclear whether coronae are decoupled from the radio feedback cycles as they have to be largely immune to strong radio outbursts. Our sample study also shows the absence of groups with a luminous cool core while hosting a strong radio AGN, which is not observed in clusters. This points to a greater impact of radio heating on low-mass systems than clusters. Few L {sub 1.4GHz} > 10{sup 24} W Hz{sup -1} radio AGNs (approx16%) host an L {sub 0.5-10keV} > 10{sup 42} erg s{sup -1} X-ray AGN, while above these thresholds, all X-ray AGNs in BCGs are also radio AGNs. As examples of the corona class, we also present detailed analyses of a BCG corona associated with a strong radio AGN (ESO 137-006 in A3627) and one of the faintest coronae known (NGC 4709 in the Centaurus cluster). Our results suggest that the traditional cool core/noncool core dichotomy is too simple. A better alternative is the cool core distribution function, with the enclosed X-ray luminosity or gas mass.

79 ASTRONOMY AND ASTROPHYSICS↗

The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment

The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz instantaneous muon rate, with a neglible pion contamination in the beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Terrestrial radiative cooling: Using the cold universe as a renewable and sustainable energy source

Photonic materials designed at wavelength scales have enabled a range of emerging energy technologies, from solid-state lighting to efficient photovoltaics that have transformed global energy landscapes. Daytime passive radiative cooling materials shed heat from the ground to the cold universe by taking advantage of the terrestrial thermal radiation that is as large as the renewable solar energy. Newly developed photonic materials permit subambient cooling under direct sunshine, and their applications are expanding rapidly enabled by scalable manufacturing. We review here the recent advancement of daytime subambient radiative cooling materials, which allow energy-efficient cooling and are paving the way toward technologies that harvest the coldness from the universe as a new renewable energy source.

Science & Technology - Other Topics↗

DES14X3taz: A TYPE I SUPERLUMINOUS SUPERNOVA SHOWING A LUMINOUS, RAPIDLY COOLING INITIAL PRE-PEAK BUMP

We present DES14X3taz, a new hydrogen-poor superluminous supernova (SLSN-I) discovered by the Dark Energy Survey (DES) supernova program, with additional photometric data provided by the Survey Using DECam for Superluminous Supernovae. Spectra obtained using Optical System for Imaging and low-Intermediate-Resolution Integrated Spectroscopy on the Gran Telescopio CANARIAS show DES14X3taz is an SLSN-I at z = 0.608. Multi-color photometry reveals a double-peaked light curve: a blue and relatively bright initial peak that fades rapidly prior to the slower rise of the main light curve. Our multi-color photometry allows us, for the first time, to show that the initial peak cools from 22,000 to 8000 K over 15 rest-frame days, and is faster and brighter than any published core-collapse supernova, reaching 30% of the bolometric luminosity of the main peak. No physical Ni-56-powered model can fit this initial peak. We show that a shock-cooling model followed by a magnetar driving the second phase of the light curve can adequately explain the entire light curve of DES14X3taz. Models involving the shock-cooling of extended circumstellar material at a distance of similar or equal to 400 R-circle dot are preferred over the cooling of shock-heated surface layers of a stellar envelope. We compare DES14X3taz to the few double-peaked SLSN-I events in the literature. Although the rise. times and characteristics of these initial peaks differ, there exists the tantalizing possibility that they can be explained by one physical interpretation

general↗

Cooling Tests of an Airplane Equipped with an NACA Cowling and a Wing-duct Cooling System

Cooling tests were made of a Northrop A-17A attack airplane successively equipped with a conventional.NACA cowling and with a wing-duct cooling system. The method of cooling the engine by admitting air from the propeller slipstream into wing ducts, passing it first through the accessory compartment and then over the engine from rear to front, appeared to offer possibilities for improved engine cooling, increased cooling of the accessories, and better fairing of the power-plant installation. The results showed that ground cooling for the wing duct system without cowl flap was better than for the NACA cowling with flap; ground cooling was appreciably improved by installing a cowl flap. Satisfactory temperatures were maintained in both climb and high-speed flight, but, with the use of conventional baffles, a greater quantity of cooling air appeared to be required for the wing duct system.

Turner, L I , Jr↗

High-Altitude Flight Cooling Investigation of a Radial Air-Cooled Engine

An investigation of the cooling of an 18-cylinder, twin-row, radial, air-cooled engine in a high-performance pursuit airplane has been conducted for variable engine and flight conditions at altitudes ranging from 5000 to 35,000 feet in order to provide a basis for predicting high-altitude cooling performance from sea-level or low altitude experimental results. The engine cooling data obtained were analyzed by the usual NACA cooling-correlation method wherein cylinder-head and cylinder-barrel temperatures are related to the pertinent engine and cooling-air variables. A theoretical analysis was made of the effect on engine cooling of the change of density of the cooling air across the engine (the compressibility effect), which becomes of increasing importance as altitude is increased. Good agreement was obtained between the results of the theoretical analysis and the experimental data.

Manganiello, Eugene J↗

Cooling of Gas Turbines: Effectiveness of Rim Cooling of Blades - 2

An analysis is presented of rim cooling of gas-turbine blades; that is, reducing the temperature at the base of the blade (wheel rim), which cools the blade by conduction alone. Formulas for temperature and stress distributions along the blade are derived and, by the use of experimental stress-rupture data for a typical blade alloy, a relation is established between blade life (time for rupture), operating speed, and amount of rim cooling for several gas temperatures. The effect of blade parameter combining the effects of blade dimensions, blade thermal conductivity, and heat-transfer coefficient is determined. The effect of radiation on the results is approximated. The gas temperatures ranged from 1300F to 1900F and the rim temperature, from 0F to 1000F below the gas temperature. This report is concerned only with blades of uniform cross section, but the conclusions drawn are generally applicable to most modern turbine blades. For a typical rim-cooled blade, gas temperature increases are limited to about 200F for 500F of cooling of the blade base below gas temperature, and additional cooling brings progressively smaller increases. In order to obtain large increases in thermal conductivity or very large decreases in heat-transfer coefficient or blade length or necessary. The increases in gas temperature allowable with rim cooling are particularly small for turbines of large dimensions and high specific mass flows. For a given effective gas temperature, substantial increases in blade life, however, are possible with relatively small amounts of rim cooling.

Wolfenstein, Lincoln↗

Effects of 'Cooled' Cooling Air on Pre-Swirl Nozzle Design

It is common practice to use Pre-Swirl Nozzles to facilitate getting the turbine blade cooling air onboard the rotating disk with minimum pressure loss and reduced temperature. Higher engine OPR's and expanded aircraft operating envelopes have pushed cooling air temperatures to the limits of current disk materials and are stressing the capability to cool the blade with practical levels of cooling air flow. Providing 'Cooled' Cooling Air is one approach being considered to overcome these limitations. This presentation looks at how the introduction of 'Cooled' Cooling Air impacts the design of the Pre-Swirl Nozzles, specifically in relation to the radial location of the nozzles.

Scricca, J. A.↗

Fighting Fire with Fire: Superlattice Cooling of Silicon Hotspots to Reduce Global Cooling Requirements

The running costs of data centers are dominated by the need to dissipate heat generated by thousands of server machines. Higher temperatures are undesirable as they lead to premature silicon wear-out; in fact, mean time to failure has been shown to decrease exponentially with temperature (Black's law). Although other server components also generate heat, microprocessors still dominate in most server configurations and are also the most vulnerable to wearout as the feature sizes shrink. Even as processor complexity and technology scaling have increased the average energy density inside a processor to maximally tolerable levels, modern microprocessors make extensive use of hardware structures such as the load-store queue and other CAM-based units, and the peak temperatures on chip can be much worse than even the average temperature of the chip. In recent studies, it has been shown that hot-spots inside a processor can generate {approx} 800W/cm{sup 2} heat flux whereas the average heat flux is only 10-50W/cm{sup 2}, and due to this disparity in heat generation, the temperature in hot spots may be up to 30 C more than average chip temperature. The key problem processor hot-spots create is that in order to prevent some critical hardware structures from wearing out faster, the air conditioners in a data center have to be provisioned for worst case requirements. Worse yet, air conditioner efficiencies decrease exponentially as the desired ambient temperature decreases relative to the air outside. As a result, the global cooling costs in data centers, which nearly equals the IT equipment power consumption, are directly correlated with the maximum hot spot temperatures of processors, and there is a distinct requirement for a cooling technique to mitigate hot-spots selectively so that the global air conditioners can operate at higher, more efficient, temperatures. We observe that localized cooling via superlattice microrefrigeration presents exactly this opportunity whereby hot-spots can be cooled selectively and allow global coolers to operate at much more efficient temperatures. Recent advances in processor cooling technologies have demonstrated that thermoelectric coolers (TEC), which use a Peltier effect to form heat pumps, can be used to reduce the temperature of hot spots. By applying a thermoelectric cooler between the heat spreader and the processor die and applying current selectively at the hot spots, heat from the hot-spots can be spread much more efficiently. The ability to implement such thermoelectric coolers on a real silicon device has been demonstrated recently, albeit for small prototype chips. The key question then, that needs to be answered before such thermoelectric coolers can be integrated in commodity server processors, is 'What is the potential for superlattice microrefrigeration to reduce global cooling costs in data centers?'. In order to answer this question, we present a comprehensive analysis of the impact of thermoelectric coolers on global cooling costs. Our thermal analysis covers all aspects of cooling a server in a data center, and integrates on-chip dynamic and leakage power sources with a detailed heat diffusion model of a processor (that models the silicon to the thermoelectric cooler to the heat spreader and the heat sink) and finally the computer room air conditioner (CRAC) efficiency, as shown in Figure 1. In Section II, we present the components of the system model.

99 GENERAL AND MISCELLANEOUS↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Experimental evaluation of cooling efficiency of the high performance cooling device

This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling active galactic nucleus feedback in cool-core clusters: The balance between heating and cooling

We study the long-term evolution of an idealized cool-core galaxy cluster under the influence of momentum-driven active galactic nucleus (AGN) feedback using three-dimensional high-resolution (60 pc) adaptive mesh refinement simulations. The feedback is modeled with a pair of precessing jets whose power is calculated based on the accretion rate of the cold gas surrounding the supermassive black hole (SMBH). The intracluster medium first cools into clumps along the propagation direction of the jets. As the jet power increases, gas condensation occurs isotropically, forming spatially extended structures that resemble the observed Hα filaments in Perseus and many other cool-core clusters. Jet heating elevates the gas entropy, halting clump formation. The cold gas that is not accreted onto the SMBH settles into a rotating disk of ∼10{sup 11} M {sub ☉}. The hot gas cools directly onto the disk while the SMBH accretes from its innermost region, powering the AGN that maintains a thermally balanced state for a few Gyr. The mass cooling rate averaged over 7 Gyr is ∼30 M {sub ☉} yr{sup –1}, an order of magnitude lower than the classic cooling flow value. Medium resolution simulations produce similar results, while in low resolution runs, the cluster experiences cycles of gas condensation and AGN outbursts. Owing to its self-regulating mechanism, AGN feedback can successfully balance cooling with a wide range of model parameters. Our model also produces cold structures in early stages that are in good agreement with the observations. However, the long-lived massive cold disk is unrealistic, suggesting that additional physical processes are still needed.

79 ASTRONOMY AND ASTROPHYSICS↗

Overall Cooling Effectiveness of Internally Cooled Additively Manufactured Blades

Power generation gas turbine blades must utilize highly effective cooling schemes to withstand moderate heat loads for long operating times. Prior work indicates that gas turbines in the 5-10 MW range primarily utilize internal cooling to prevent further increase of aerodynamic losses that result from film cooling, but few studies focus solely on internal cooling. In this study, three additively manufactured internal cooling designs were tested in the 50 percent span section of the National Experimental Turbine (NExT) blade: a baseline cooling design with pin-fin arrays and rib turbulators, a double wall design with impingement jets and serpentine channels, and an incremental impingement design. The designs were tested in a high-speed linear cascade at exit Reynolds numbers ranging from 700,000 to 1,400,000 at an exit Mach of 0.8. In addition, freestream turbulence and build angle effects on cooling performance were studied.

gas turbine blades↗

Investigating the Urban Air Quality Effects of Cool Walls and Cool Roofs in Southern California

Solar reflective cool roofs and walls can be used to mitigate the urban heat island effect. While past research has investigated the climate impacts of adopting cool surfaces, few studies have investigated their effects on air pollution, especially on particulate matter (PM). This study for the first time investigates the influence of widespread deployment of cool walls on urban air pollutant concentrations, and systematically compares cool wall to cool roof effects. Simulations using a coupled meteorology-chemistry model (WRF-Chem) for a representative summertime period show that cool walls and roofs can reduce urban air temperatures, wind speeds, and planetary boundary heights in the Los Angeles Basin. Consequently, increasing wall (roof) albedo by 0.80, an upper bound scenario, leads to maximum daily 8-h average ozone concentration reductions of 0.35 (0.83) ppbv in Los Angeles County. However, cool walls (roofs) increase daily average PM2.5 concentrations by 0.62 (0.85) μg m-3. We investigate the competing processes driving changes in concentrations of speciated PM2.5. Increases in primary PM (elemental carbon and primary organic aerosols) concentrations can be attributed to reductions in ventilation of the Los Angeles Basin. Increases in concentrations of semivolatile species (e.g., nitrate) are mainly driven by increases in gas-to-particle conversion due to reduced atmospheric temperatures.

54 ENVIRONMENTAL SCIENCES↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗