Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTROLLED AREAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Area 6 Control Point: An Architectural Survey of the Area 6 Control Point, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) proposes to demolish five buildings and five accessory resources in the Area 6 Control Point at the Nevada National Security Site (NNSS) in Nye County, Nevada. The demolition and removal of the buildings and accessories constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. The buildings and accessories were recorded in Identification and Evaluation of 14 Architectural Resources Scheduled for Demolition, Area 6 Control Point and Vicinity, Nevada National Security Site, Nye County, Nevada (Menocal et al. 2020). The report found that the five buildings were not individually eligible for listing in the National Register of Historic Places (NRHP, National Register) but were potentially eligible as contributing elements to an unrecorded Area 6 Control Point district. The report also found that the five accessory resources were not individually eligible for the NRHP but they contributed to other historic properties, including the contributing elements to the unrecorded district. Finally, the report found that the undertaking would result in an adverse effect to historic properties. The State Historic Preservation Office (SHPO) concurred with the report’s findings regarding the eligibility of the buildings and structures in the Area of Potential Effect (APE) and that the undertaking would result in an adverse effect (Reed 2020). The NNSA/NFO, in consultation with the SHPO, then developed the Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County, hereafter referred to as the MOA. The MOA stipulates that a district boundary be delineated with an accompanying boundary report and supporting photographs (Stipulation III.A) followed by an architectural survey of the potential historic district (Stipulation III.B). The SHPO reviewed and concurred with the proposed district boundary and accompanying boundary report and photographs (O’Neill et al. 2021) on August 23, 2021, in fulfillment of Stipulation III.A (Reed 2021). This architectural survey report has been prepared in accordance with Stipulation III.B. It includes an NRHP evaluation of the district, identifies contributing and non-contributing elements, and is accompanied by Architectural Resource Assessment (ARA) forms. The NRHP evaluation concludes that the Area 6 Control Point is recommended eligible as a historic district under the Secretary of the Interior’s Significance Criterion A at the national level as the location of the command center and various support facilities directly related to timing and firing operations for nuclear testing on the NNSS from 1951 to 1992. It is also recommended eligible under Significance Criterion C for embodying the distinctive characteristics of a nuclear command center in the context of the Cold War and as a significant and distinguishable entity. There are a total of 29 primary resources within the district boundary. Of these, 28 are recommended as contributing elements to the Area 6 Control Point Historic District and one is recommended as non-contributing.

54 ENVIRONMENTAL SCIENCES↗

Design of vortex fluid amplifiers with asymmetrical flow fields.

Variation of geometric parameters, including supply area, control area, chamber length, and outlet diameter, of a large scale, modular design vortex fluid amplifier with single supply and control jets, has confirmed and extended a previously published design method, developed for vortex amplifiers with symmetric flow fields. This allows application of the method to devices which are more representative of practical, production type components.

Lawley, T. J.↗

Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems

Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Universal Wide-area Damping Control for Mitigating Inter-area Oscillations in Power Systems

The active damping of inter-area oscillations of low frequencies has been successfully demonstrated to improve the dynamic response of the power grid in a satisfactory manner. It also enhances the system stability and reliability as well. The existence of inter-area oscillations has already become one of the key challenges in large-scale interconnected power grids because they are detrimental to the achievement of maximum power transfer and optimal power flow. This project focuses on the development of a universal damping control based on phasor measurements so that it can be easily implemented by a mix of various fast-acting resources to effectively mitigate inter-area oscillations. With the proposed advanced damping control strategies, the power grid stability and reliability can be managed in a much more flexible manner by utilizing different resources that are geographically dispersed in both the transmission and distribution systems. Moreover, higher power transfer capacity can be also achieved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchrophasor spoofing detection and remediation for wide-area damping control

Evolving cyber-attack threats put at risk automatic closed-loop systems to be incorporated in the smart grid. Wide-area control systems are particularly vulnerable to signal spoofing attacks due to sensor remoteness and dependence on satellite communication for time synchronization. A successful cyber-attack on a wide-area controller has the potential to reduce relative stability of the power system or worse, destabilize it. As such, detection algorithms must be deployed as defense against such attacks with the ability to autonomously correct for detected tampering or misoperation. The Spoof Catch and Restore Routine (SCR 2 ), a combination of three real-time spoof detectors, each requiring limited information about the plant, is reported here. Nonlinear simulations of a compromised wide-area control system deployed in the Western Interconnection show the effectiveness of SCR 2 in detecting both delay-type and counterfeit-type spoofing attacks on wide-area sensors.

42 ENGINEERING↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Future of Air Traffic Management

A system for the control of terminal area traffic to improve productivity, referred to as the Center-TRACON Automation System (CTAS), is being developed at NASA's Ames Research Center under a joint program with the FAA. CTAS consists of a set of integrated tools that provide computer-generated advisories for en-route and terminal area controllers. The premise behind the design of CTAS has been that successful planning of traffic requires accurate trajectory prediction. Data bases consisting of representative aircraft performance models, airline preferred operational procedures and a three dimensional wind model support the trajectory prediction. The research effort has been the design of a set of automation tools that make use of this trajectory prediction capability to assist controllers in overall management of traffic. The first tool, the Traffic Management Advisor (TMA), provides the overall flow management between the en route and terminal areas. A second tool, the Final Approach Spacing Tool (FAST) provides terminal area controllers with sequence and runway advisories to allow optimal use of the runways. The TMA and FAST are now being used in daily operations at Dallas/Ft. Worth airport. Additional activities include the development of several other tools. These include: 1) the En Route Descent Advisor that assist the en route controller in issuing conflict free descents and ascents; 2) the extension of FAST to include speed and heading advisories and the Expedite Departure Path (EDP) that assists the terminal controller in management of departures; and 3) the Collaborative Arrival Planner (CAP) that will assist the airlines in operational decision making. The purpose of this presentation is to review the CTAS concept and to present the results of recent field tests. The paper will first discuss the overall concept and then discuss the status of the individual tools.

Denery, Dallas G.↗

Secure Communications Concept and API Concept for Integrating XENDEE Positronix with TESLA PowerPack System at Site 300 (Final Deliverable)

The CleanStart DERMS project focuses on the management of Distributed Energy Resources (DER) for enhanced distribution grid resilience. The demonstration site has changed from Riverside Public Utility to the LLNS Site 300 DERS demonstration site. This project has so far focused only on device level controllers and local area controllers. These controllers potentially lack the ability to perform supervisory control and grid interactive control functions, essential for grid-level optimal DER management. This project seeks to close that gap in development of secure communication concept and appropriate Application Programming Interfaces (API) to enable integration with DERs, device level and local area controllers, such as Distributed Energy Resources Management System (DERMS).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection and Mitigation for Wide-Area Damping Control using Machine Learning

In an interconnected multi-area power system, wide-area measurement based damping controllers are used to damp out inter-area oscillations, which jeopardize grid stability and constrain the power flows below to their transmission capacity. The effect of wide-area damping control (WADC) significantly depends on both power and cyber systems. At the cyber system layer, an adversary can inflict the WADC process by compromising either measurement signals, control signals or both. Stealthy and coordinated cyber-attacks may bypass the conventional cybersecurity measures to disrupt the seamless operation of WADC. This paper proposes an anomaly detection (AD) algorithm using supervised Machine Learning and a model-based logic for mitigation. The proposed AD algorithm considers measurement signals (input of WADC) and control signals (output of WADC) as input to evaluate the type of activity such as normal, perturbation (small or large signal faults), attack and perturbation-and-attack. Upon anomaly detection, the mitigation module tunes the WADC signal and sets the control status mode as either wide-area mode or local mode. The proposed anomaly detection and mitigation (ADM) module works inline with the WADC at the control center for attack detection on both measurement and control signals and eliminates the need for ADMs at the geographically distributed actuators. Here, we consider coordinated and primitive data-integrity attack vectors such as pulse, ramp, relay-trip and replay attacks. The performance of the proposed ADM algorithms was evaluated under these attack vector scenarios on a testbed environment for 2-area 4-machine power system. The ADM module shows effective performance with 96:5% accuracy to detect anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spacelab Mission Simulation-II

The NASA Johnson Space Center conducted the second in a series of Spacelab mission simulations during the week of January 26-February 1, 1976. The facilities that supported the Spacelab Mission Simulation-II (SMS-II) included mock-ups of Spacelab, the Orbiter mid-deck and aft flight deck areas, and support areas simulating a mission control area and a payload operation control area. The SMS-II encompassed presently identified Spacelab mission requirements including experiment solicitation, evaluation, selection, and prioritization; crew selection and training; experiment hardware development, integration, and evaluation. The payload chosen included a cosmic ray physics experiment which was located on a pallet aft of the Spacelab and 20 biomedical experiments which were performed in the Spacelab. This paper will summarize simulation experience to date and list areas requiring substantial evaluation in the future.

Sawin, C. F.↗