Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAMINANT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Propulsive trajectory optimization to minimize surface contamination

MOTIVATION: We present an optimization technique for propulsive vehicles that autonomously minimizes contamination during surface approach and landing. In addition to short-range hoppers, the optimization technique is also fully applicable to traditional orbit-to-surface landers. This study addresses scenarios where surface alterations from propulsion events are counterproductive or hazardous to the mission objectives. This is of immediate interest for landers (whether human or robotic), that may rely on pristine soils collected in the immediate vicinity of landing sites to accomplish science investigations, mining, or ISRU surface operations. Such missions are averse to various surface-plume interactions such as thermal scoring, physical agitation, and contamination. The capability can be applied with minimal impact to the baseline mission concept. METHODS: Optimization algorithms have been developed to calculate descent trajectories and maneuvers, thrust magnitude, and attitude for various mission cases. These parameters are determined as an optimal solution when minimizing either fuel consumption, contamination deposited at the landing site, or some weighted combination of both. Among constraints imposed on the solution, we examined pitch rate, vertical takeoff and vertical landing (VTVL) requirements, size of the contamination zone, and minimum ground clearance during flight. This tool provides unique, non-intuitive solutions and can be a valuable resource for mission planners. RESULTS: A variety of agile trajectory solutions were obtained, each yielding different reductions in landing site contamination and corresponding to only modest increases in fuel consumption. Several optimal trajectories were obtained by varying the contamination weight in the fitness function. As expected, when the contamination weight is zero, the trajectory appears close to parabolic since the optimization scheme only attempts to minimize for fuel utilization, yielding essentially, the expected ballistic trajectory. Notably for contamination weights greater than zero, trajectory inflections are observed in the descent phase, which manifests as hovering or additional, mini “pseudo hops” before the final touchdown. A trajectory inflection is characterized by arresting the majority of the spacecraft vertical velocity component at a coordinate outside of the landing target, and without violating ground clearance constraints. FUTURE WORK: Our optimization technique is ready for laboratory or field demonstrations to validate the sophisticated maneuvering solutions obtained for fuel optimization and surface preservation. An appropriate testbed would validate the optimal guidance algorithms, the navigation system, and sensor suite by emulating vehicle flight in closed loop robotic tests. Critically, these algorithms could then be ported to flight software for implementation.

surface contamination↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

TCPS↗

Fitness factors impacting survival of a subsurface bacterium in contaminated groundwater

Many factors contribute to the ability of a microbial species to persist when encountering complexly contaminated environments, including time of exposure, the nature and concentration of contaminants, availability of nutritional resources, and possession of a combination of appropriate molecular mechanisms needed for survival. Herein we sought to identify genes that are most important for survival of Gram-negative Enterobacteriaceae in contaminated groundwater environments containing high concentrations of nitrate and metals using the metal-tolerant Oak Ridge Reservation isolate, Pantoea sp. MT58 (MT58). Survival fitness experiments in which a randomly barcoded transposon insertion (RB-TnSeq) library of MT58 was exposed directly to contaminated Oak Ridge Reservation groundwater samples from across a nitrate and mixed metal contamination plume were used to identify genes important for survival with increasing exposure times and concentrations of contaminants, and availability of a carbon source. Genes involved in controlling and using carbon, encoding transcriptional regulators, and related to Gram-negative outer membrane processes were among those found to be important for survival in contaminated Oak Ridge Reservation groundwater. A comparative genomics analysis of 75 Pantoea genus strains allowed us to further separate the survival determinants into core and non-core genes in the Pantoea pangenome, revealing insights into the survival of subsurface microorganisms during contaminant plume intrusion.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation Monitoring for Volatilized Zinc Contamination Using Gamma-Ray Imaging and Spectroscopy

Gamma-ray imaging is a tool that has grown in importance in the applications of non-destructive assay (NDA) for radioactive survey and analysis of nuclear facilities. Imaging techniques have shown great promise in providing valuable information involving radioactive waste management and contamination prevention. For the application studied in this work, 65 Zn has been identified as a radioactive contaminant during tritium extraction. Due to the volatile nature of 65 Zn under the pressure and temperature changes during extraction operations, 65 Zn can easily travel through components of the extraction system as vapor, making it difficult to trap. Previous research involving the development of a filtration system showed that the 65 Zn can be trapped, mitigating product contamination. However, during the extraction process, direct analysis of the equipment to confirm that zinc contamination is trapped in the filter and has not spread to other components is impractical. Here, in this situation, the need to assay the location of the contamination with little-to-no interference with operations is vital. In this work, we demonstrate the use of a commercialized 3D position-sensitive CdZnTe (CZT) gamma-ray imaging spectrometer to provide analysis of the 65 Zn contamination. Onsite measurements during an extraction process are studied to assess the location and migration of the 65 Zn. The results obtained from real-time glovebox monitoring demonstrate the feasibility of gamma-ray imaging for localizing the contamination and providing a preliminary qualitative assessment that is intended to be used in future work quantifying the contamination build-up and activity over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of Grey Box/Black Box Data Contamination Metrics on Open and Commercial Models

Dataset contamination is a problem where benchmarks and tasks used to evaluate the capabilities of Large Language Models (LLMs) have been incorporated into the training dataset of the models. This gives a false sense of performance that can overestimate how these models will function on truly unseen data. This problem becomes worse with commercial LLMs with larger and non-accessible training data, so techniques have been developed to try to measure the degree to which a model is contaminated with a benchmark’s data. To understand the effectiveness of these techniques, particularly when evaluating contamination on coding tasks, we review trends and categorize techniques by the degree of access to the model that is required. The research literature on this topic has reported mixed effectiveness of these techniques, so we select a set of black box (text access only) and grey box (access to model loss/probabilities required) techniques and apply them to both commercial and non-commercial models. We implement these metrics as part of a framework to test the contamination of Python code in LLMs to see to what extent we can replicate the effectiveness (or ineffectiveness) of these contamination detection techniques. Though we find mixed results in the capabilities of these metrics to identify contamination, we do observe evidence that they can identify contamination (broadly) in fine-tuned models when both a baseline and fine-tuned model is present. Additionally, similarity metrics were able to identify between contaminated and uncontaminated data even in situations where the data is distributionally similar (e.g., drawn from the same set of code projects).

97 MATHEMATICS AND COMPUTING↗

MSFC Skylab contamination control systems mission evaluation

Cluster external contamination control evaluation was made throughout the Skylab Mission. This evaluation indicated that contamination control measures instigated during the design, development, and operational phases of this program were adequate to reduce the general contamination environment external to the Cluster below the threshold senstivity levels for experiments and affected subsystems. Launch and orbit contamination control features included eliminating certain vents, rerouting vents for minimum contamination impact, establishing filters, incorporating materials with minimum outgassing characteristics and developing operational constraints and mission rules to minimize contamination effects. Prior to the launch of Skylab, contamination control math models were developed which were used to predict Cluster surface deposition and background brightness levels throughout the mission. The report summarizes the Skylab system and experiment contamination control evaluation. The Cluster systems and experiments evaluated include Induced Atmosphere, Corollary and ATM Experiments, Thermal Control Surfaces, Solar Array Systems, Windows and Star Tracker.

Source record↗

Space station trace contaminant control

Different systems for the control of space station trace contaminants are outlined. The issues discussed include: spacecabin contaminant sources, technology base, contaminant control system elements and configuration, approach to contaminant control, contaminant load model definition, spacecraft maximum allowable concentrations, charcoal bed sizing and performance characteristics, catalytic oxidizer sizing and performance characteristics, special sorbent bed sizing, animal and plant research payload problems, and emergency upset contaminant removal. It is concluded that the trace contaminant control technology base is firm, the necessary hardware tools are available, and the previous design philosophy is still applicable. Some concerns are the need as opposed to danger of the catalytic oxidizer, contaminants with very low allowable concentrations, and the impact of relaxing materials requirements.

Olcutt, T.↗

Assessment of external contamination for Space Station scientific payloads

This paper presents the analysis of the nature, the source, and the effect of contamination encountered by payloads external to the Space Station spacecraft. The contaminant modeling study determined the key contaminant sources for the Space Station payloads, together with the location, the duration, the major constituents of the contaminant, and the possibility of contaminant control. The next phase of the contamination modeling study investigates the compatibility of external Space Station payloads while on the transverse boom and the dual keel option. Other predictions include depositions on payload surfaces facing along +X, +Y, and +Z directions. An additional analysis will utilize the above data to predict the spectral brightness of the contaminants along payload lines-of-sight, making it possible for payload users to determine the impact of the contaminant background relative to the natural background.

Primeaux, Gary R.↗

Spacecraft Maximum Allowable Concentrations for Selected Airborne Contaminants

As part of its efforts to promote safe conditions aboard spacecraft, NASA requested the National Research Council (NRC) to develop guidelines for establishing spacecraft maximum allowable concentrations (SMACs) for contaminants, and to review SMACs for various spacecraft contaminants to determine whether NASA's recommended exposure limits are consistent with the guidelines recommended by the subcommittee. In response to NASA's request, the NRC organized the Subcommittee on Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants within the Committee on Toxicology (COT). In the first phase of its work, the subcommittee developed the criteria and methods for preparing SMACs for spacecraft contaminants. The subcommittee's report, entitled Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants , was published in 1992. The executive summary of that report is reprinted as Appendix A of this volume. In the second phase of the study, the Subcommittee on Spacecraft Maximum Allowable Concentrations reviewed reports prepared by NASA scientists and contractors recommending SMACs for approximately 35 spacecraft contaminants. The subcommittee sought to determine whether the SMAC reports were consistent with the 1992 guidelines. Appendix B of this volume contains the SMAC reports for 12 chemical contaminants that have been reviewed for their application of the guidelines developed in the first phase of this activity and approved by the subcommittee. This report is the second volume in the series Spacecraft McLrimum Allowable Concentrations for Space Station Contaminants . The first volume was published in 1994.

National Research Council↗

Applying Contamination Modelling to Spacecraft Propulsion Systems Designs and Operations

Molecular and particulate contaminants generated from the operations of a propulsion system may impinge on spacecraft critical surfaces. Plume depositions or clouds may hinder the spacecraft and instruments from performing normal operations. Firing thrusters will generate both molecular and particulate contaminants. How to minimize the contamination impact from the plume becomes very critical for a successful mission. The resulting effect from either molecular or particulate contamination of the thruster firing is very distinct. This paper will discuss the interconnection between the functions of spacecraft contamination modeling and propulsion system implementation. The paper will address an innovative contamination engineering approach implemented from the spacecraft concept design, manufacturing, integration and test (I&T), launch, to on- orbit operations. This paper will also summarize the implementation on several successful missions. Despite other contamination sources, only molecular contamination will be considered here.

Chen, Philip T.↗

Induced Contamination Predictions for JAXA's MPAC&SEED Devices

Externally mounted ISS payloads are exposed to the induced ISS environment, including material outgassing and thruster plume contamination. The Boeing Space Environments Team developed analytical and semiempirical models to predict material outgassing and thruster plume induced contamination. JAXA s SM/MPAC&SEED experiment provides an unique opportunity to compare induced contamination predications with measurements. Analysis results are qualitatively consistent with XPS measurements. Calculated depth of contamination within a factor of 2-3 of measured contamination. Represents extremely good agreement, especially considering long duration of experiment and number of outgassing sources. Despite XPS limitations in quantifying plume contamination, the measured and predicted results are of similar scale for the wake-facing surfaces. JAXA s JEM/MPAC&SEED experiment will also be exposed to induced contamination due to JEM and ISS hardware. Predicted material outgassing induced contamination to JEM/MPAC&SEED ranges from 44 to 262 (depending on surface temperature) for a 3 year exposure duration.

Steagall, Courtney↗

Design and Testing of Trace Contaminant Injection and Monitoring Systems

In support of the Carbon dioxide And Moisture Removal Amine Swing-bed (CAMRAS) testing, a contaminant injection system as well as a contaminant monitoring system has been developed by the Johnson Space Center Air Revitalization Systems (JSC-ARS) team. The contaminant injection system has been designed to provide trace level concentrations of contaminants generated by humans in a closed environment during space flight missions. The contaminant injection system continuously injects contaminants from three gas cylinders, two liquid reservoirs and three permeation ovens. The contaminant monitoring system has been designed to provide real time gas analysis with accurate flow, humidity and gas concentration measurements for collection during test. The contaminant monitoring system consists of an analytical real time gas analyzer, a carbon monoxide sensor, and an analyzer for ammonia and water vapor.

Broerman, Craig D.↗

International Space Station External Contamination Status

PResentation slides examine external contamination requirements; International Space Station (ISS) external contamination sources; ISS external contamination sensitive surfaces; external contamination control; external contamination control for pre-launch verification; flight experiments and observations; the Space Shuttle Orbiter waste water dump, materials outgassing, active vacuum vents; example of molecular column density profile, modeling and analysis tools; sources of outgassing induced contamination analyzed to date, quiescent sources, observations on optical degradation due to induced external contamination in LEO; examples of typical contaminant and depth profiles; and status of the ISS system, material outgassing, thruster plumes, and optical degradation.

Mikatarian, Ron↗

Electrokinetic In Situ Treatment of Metal-Contaminated Soil

An electrokinetic technique has been developed as a means of in situ remediation of soils, sludges, and sediments that are contaminated with heavy metals. Examples of common metal contaminants that can be removed by this technique include cadmium, chromium, zinc, lead, mercury, and radionuclides. Some organic contaminants can also be removed by this technique. In the electrokinetic technique, a low-intensity direct current is applied between electrodes that have been implanted in the ground on each side of a contaminated soil mass. The electric current causes electro-osmosis and migration of ions, thereby moving aqueous-phase subsurface contaminants from one electrode to the other. The half reaction at the anode yields H+, thereby generating an acid front that travels from the anode toward the cathode. As this acid front passes through a given location, the local increase in acidity increases the solubility of cations that were previously adsorbed on soil particles. Ions are transported towards one electrode or the other which one depending on their respective electric charges. Upon arrival at the electrodes, the ionic contaminants can be allowed to become deposited on the electrodes or can be extracted to a recovery system. Surfactants and other reagents can be introduced at the electrodes to enhance rates of removal of contaminants. Placements of electrodes and concentrations and rates of pumping of reagents can be adjusted to maximize efficiency. The basic concept of electrokinetic treatment of soil is not new. What is new here are some of the details of application and the utilization of this technique as an alternative to other techniques (e.g., flushing or bioremediation) that are not suitable for treating soils of low hydraulic conductivity. Another novel aspect is the use of this technique as a less expensive alternative to excavation: The cost advantage over excavation is especially large in settings in which contaminated soil lies near and/or under industrial buildings and therefore excavation would be made even more expensive by the need to prevent damage to numerous underground pipes and cables.

Quinn, Jacqueline↗

External Contamination Control of Attached Payloads on the International Space Station

The International Space Station (ISS) is an on-orbit platform for science utilization in low Earth orbit with multiple sites for external payloads with exposure to the natural and induced environments. Contamination is one of the induced environments that can impact performance, mission success and science utilization on the vehicle. This paper describes the external contamination control requirements and integration process for externally mounted payloads on the ISS. The external contamination control requirements are summarized and a description of the integration and verification process is detailed to guide payload developers in the certification process of attached payloads on the vehicle. A description of the required data certification deliverables covers the characterization of contamination sources. Such characterization includes identification, usage and operational data for each class of contamination source. Classes of external contamination sources covered are vacuum exposed materials, sources of leakage, vacuum venting and thrusters. ISS system level analyses are conducted by the ISS Space Environments Team to certify compliance with external contamination control requirements. This paper also addresses the ISS induced contamination environment at attached payload sites, both at the requirements level as well as measurements made on ISS.

Soares, Carlos E.↗

Determining Temperature Differential to Prevent Hardware Cross-Contamination in a Vacuum Chamber

When contamination-sensitive hardware must be tested in a thermal vacuum chamber, cross-contamination from other hardware present in the chamber, or residue from previous tests, becomes a concern. Typical mitigation strategies involve maintaining the temperature of the critical item above that of other hardware elements at the end of the test. A formula for relating the pumping speed of a chamber, the surface area of contamination sources, and the temperatures of the chamber, source, and contamination-sensitive items has been developed. The formula allows the determination of a temperature threshold about which contamination will not condense on the sensitive items. It defines a parameter alpha that is the fraction given by (contaminant source area)/[chamber pumping speed (time under vacuum) 0.5]. If this parameter is less than 10(exp -6), cross-contamination from common spacecraft material will not occur when the sensitive hardware is at the same temperature as the source of contamination (The chamber is isothermal within 5 C.). Knowing when it becomes safe to have the hardware isothermal permits faster and easier thermal transitions when compared with maintaining an arbitrary temperature differential between parts. Furthermore, the standard temperature differential may not be adequate under some conditions (alpha>10(exp -4)).

Hughes, David↗

Evaluation of a Candidate Trace Contaminant Control Subsystem Architecture: The High Velocity, Low Aspect Ratio (HVLA) Adsorption Process

Traditional gas-phase trace contaminant control adsorption process flow is constrained as required to maintain high contaminant single-pass adsorption efficiency. Specifically, the bed superficial velocity is controlled to limit the adsorption mass-transfer zone length relative to the physical adsorption bed; this is aided by traditional high-aspect ratio bed design. Through operation in this manner, most contaminants, including those with relatively high potential energy are readily adsorbed. A consequence of this operational approach, however, is a limited available operational flow margin. By considering a paradigm shift in adsorption architecture design and operations, in which flows of high superficial velocity are treated by low-aspect ratio sorbent beds, the range of well-adsorbed contaminants becomes limited, but the process flow is increased such that contaminant leaks or emerging contaminants of interest may be effectively controlled. To this end, the high velocity, low aspect ratio (HVLA) adsorption process architecture was demonstrated against a trace contaminant load representative of the International Space Station atmosphere. Two HVLA concept packaging designs (linear flow and radial flow) were tested. The performance of each design was evaluated and compared against computer simulation. Utilizing the HVLA process, long and sustained control of heavy organic contaminants was demonstrated.

Kayatin, Matthew J.↗

Cleanroom Contamination Identification Method Development

During fabrication, assembly, and testing of spacecraft and flight hardware it is vital to avoid contaminants that can cause degradation and could result in significant failure. Yet, there is no existing contamination monitoring method that provides the identity of airborne particles in a cleanroom facility. Knowing the particle identities, would allow scientists and engineers to determine the source of the contaminants and prevent setbacks before they occur or cause damage. Current cleanliness monitoring methods include airborne particle counters (APCs), fallout filters, and visual inspections. Particle counts from APCs are the primary metric used to define a cleanroom class and hence its level of cleanliness, but do not provide identification nor can they differentiate between large and small sizes of particles. In addition, using fallout filters is not a proactive, timely, or representative approach to cleanroom contamination monitoring because these samples are only retrieved after 30 days and are placed away from spacecraft processing to avoid interference with operations. In contrast, the forced air sampling method can collect a sample within an hour at any location required and provide results in less than a day. This system uses a cassette and filter sample medium to capture airborne particles which are then taken to a scanning electron microscope with energy dispersive spectroscopy (SEM/EDS) to identify and size the captured particles. Development of forced air sampling into an established laboratory capability will allow for fast sampling and routine identification of unknown contamination sources within the cleanroom. The test method development required market research for an air sampling cassette that increases sample collection efficiency and a filter with low enough background contamination to allow differentiation between a blank (control) and the collected sample. It was determined that a conductive black cassette and a polycarbonate filter were the best options. Conductive black cassettes, in comparison to the standard styrene, are manufactured using polypropylene filled with carbon. This makes the cassette conductive and minimizes the tendency of particles to stick to the wall of the cassette due to electrostatic force. In previous trials a mixed cellulose ester (MCE) filter was used to capture the contaminants, however the rougher surface of the filter contributed to entrapment of the particles within the filter structure and made it harder to identify the particles. In comparison, track etched polycarbonate filters have random cylindrical pores and a smooth surface which contributes to uniform sample distribution on the surface of the filter. Future work includes: testing the system using control samples to determine the efficiency and suitability of the medium, performing sample collection in various environments to establish ideal operating parameters and analyzing contaminant particles using SEM/EDS and assistant characterization techniques. Once fully developed, employing the forced air sampling method will help to prevent damage to spacecraft, avoid schedule delays, and allow for mission success.

Hernandez Melendez, Jailyn M.↗