Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Magnetic Nulls and Super-radial Expansion in the Solar Corona

Magnetic fields in the Sun’s outer atmosphere—the corona—control both solar-wind acceleration and the dynamics of solar eruptions. We present the first clear observational evidence of coronal magnetic nulls in off-limb linearly polarized observations of pseudostreamers, taken by the Coronal Multichannel Polarimeter (CoMP) telescope. These nulls represent regions where magnetic reconnection is likely to act as a catalyst for solar activity. CoMP linear-polarization observations also provide an independent, coronal proxy for magnetic expansion into the solar wind, a quantity often used to parameterize and predict the solar wind speed at Earth. We introduce a new method for explicitly calculating expansion factors from CoMP coronal linear-polarization observations, which does not require photospheric extrapolations. We conclude that linearly polarized light is a powerful new diagnostic of critical coronal magnetic topologies and the expanding magnetic flux tubes that channel the solar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Segmentation of RDX and TNT in X‐Ray Computed Tomography Reconstructions of Melt‐Cast Explosives

ABSTRACT Three‐dimensional mesoscale characterization of heterogeneous melt‐cast high explosives is challenging because of the difficulty differentiating binder from explosive crystals: two functionally different materials which are typically similar in density by design. Here, we report an algorithm which can differentiate hexahydro‐1,3,5‐trinitro‐1,3,5‐triazine (RDX) from 2,4,6‐trinitrotoluene (TNT) in x‐ray computed tomography (CT) volumes with tens of microns resolution. This method allows us to quantify RDX/TNT content, porosity, and RDX domain size. We calibrated the segmentation algorithm using simulated x‐ray CT volumes containing object models of RDX crystals within a TNT matrix. We then segmented and analyzed CT data for Composition B (Comp B), a 60/40 RDX/TNT mixture, and Cyclotol, a 75/25 RDX/TNT mixture. We examined melt‐cast samples fabricated with 100% theoretical maximum density (TMD) and 85% TMD. For the 100% TMD Comp B and Cyclotol samples, the RDX content values calculated by segmentation were 3% and 9% lower, respectively, than the values measured by high‐performance liquid chromatography on material from the same synthesis lots. This result is consistent with the expected underreporting of RDX content resulting from x‐ray CT resolution limits on RDX particles with diameters smaller than 25 µm. The 85% TMD samples were less accurately segmented with our algorithm due to the confounding presence of voids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polarized neutron measurements of the internal magnetization of a ferrimagnet across its compensation temperature

We present the first polarized neutron transmission image of a model Néel ferrimagnetic material, polycrystalline terbium iron garnet (Tb 3 Fe 5 O 12 , TbIG for short), as it is taken through its compensation temperature T comp where the macroscopic magnetization vanishes. Our polarized neutron imaging data and the additional supporting measurements using neutron spin echo spectroscopy and SQUID magnetometry are all consistent with a vanishing internal magnetization at T comp .

Ferrimagnetism↗

Benchmarking ENDF/B-VII.1, JENDL-4.0 and JEFF-3.1.1 with MCNP6

Recent releases of three major world nuclear reaction data libraries, ENDF/B-VII.1, JENDL-4.0, and JEFF-3.1.1, have been tested extensively using benchmark calculations. The calculations were performed with the latest release of the continuous energy Monte Carlo neutronics code MCNP, i.e. MCNP6. Three types of benchmarks were used, viz. criticality safety benchmarks, (fusion) shielding benchmarks, and reference systems for which the effective delayed neutron fraction is reported. For criticality safety, more than 2000 benchmarks from the International Handbook of Criticality Safety Benchmark Experiments were used. Benchmarks from all categories were used, ranging from low-enriched uranium, compound fuel, thermal spectrum ones (LEU-COMP-THERM), to mixed uranium-plutonium, metallic fuel, fast spectrum ones (MIX-MET-FAST). For fusion shielding many benchmarks were based on IAEA specifications for the Oktavian experiments (for Al, Co, Cr, Cu, LiF, Mn, Mo, Si, Ti, W, Zr), Fusion Neutronics Source in Japan (for Be, C, N, O, Fe, Pb), and Pulsed Sphere experiments at Lawrence Livermore National Laboratory (for {sup 6}Li, {sup 7}Li, Be, C, N, O, Mg, Al, Ti, Fe, Pb, D2O, H2O, concrete, polyethylene and teflon). The new functionality in MCNP6 to calculate the effective delayed neutron fraction was tested by comparison with more than thirty measurements in widely varying systems. Among these were measurements in the Tank Critical Assembly (TCA in Japan) and IPEN/MB-01 (Brazil), both with a thermal spectrum, two cores in Masurca (France) and three cores in the Fast Critical Assembly (FCA, Japan), all with fast spectra. The performance of the three libraries, in combination with MCNP6, is shown to be good. The results for the LEU-COMP-THERM category are on average very close to the benchmark value. Also for most other categories the results are satisfactory. Deviations from the benchmark values do occur in certain benchmark series, or in isolated cases within benchmark series. Such instances can often be related to nuclear data for specific non-fissile elements, such as C, Fe, or Gd. Indications are that the intermediate and mixed spectrum cases are less well described. The results for the shielding benchmarks are generally good, with very similar results for the three libraries in the majority of cases. Nevertheless there are, in certain cases, strong deviations between calculated and benchmark values, such as for Co and Mg. Also, the results show discrepancies at certain energies or angles for e.g. C, N, O, Mo, and W. The functionality of MCNP6 to calculate the effective delayed neutron fraction yields very good results for all three libraries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Water Solubility at Saturation for CO 2 –CH 4 Mixtures at 323.2 K and 9.000 MPa

The concentration of H 2 O dissolved in CO 2 –CH 4 supercritical fluids is an important parameter that can control shale permeability, affect CH 4 transmissivity, and ultimately impact the efficiency of CO 2 enhanced gas recovery (EGR) operations. Here, we use in situ high-pressure infrared (IR) spectroscopic titrations to quantify the solubility of H 2 O in six CO 2 –CH 4 mixtures, ranging from pure CO 2 to pure CH 4 , at shallow shale reservoir conditions of 323.2 K and 9.000 MPa. Measured concentrations of H 2 O at saturation increase with increasing mole percent CO 2 , and our results are in agreement with limited data available in the literature. We use these experimental results to benchmark three current thermodynamic multiphase routines: the mixed-solvent electrolyte (MSE), STOMP-COMP, and the Statistical Associating Fluid Theory for variable range Mie potentials (SAFT γ-Mie) equations of state. We find that, of these models, MSE and STOMP-COMP accurately predict maximum H 2 O solubilities of the binary CO 2 –H 2 O and CH 4 –H 2 O systems, and they also reproduce the shape of the water solubility curve as a function of mole percent CO 2 . Hence, these routines should work well to predict H 2 O content in reservoir simulations and help to make informed decisions concerning injection strategies for CO 2 EGR in shale plays at shallow depths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reentrant spin-glass behavior and bipolar exchange-bias effect in “Sn” substituted cobalt-orthotitanate

We report the co-existence of longitudinal ferrimagnetic behavior with Néel temperature T{sub N} ∼ 46.1 K and reentrant transverse spin-glass state at 44.05 K in Tin (Sn) doped cobalt-orthotitanate (Co{sub 2}TiO{sub 4}). The ferrimagnetic ordering is resulting from different magnetic moments of Co{sup 2+} on the A-sites (3.87 μ{sub B}) and B-sites (5.069 μ{sub B}). The magnetic compensation temperature (T{sub COMP}) shifts from 31.74 K to 27.1 K when 40 at. % of “Sn{sup 4+}” substitutes “Ti{sup 4+}” at B-sites where the bulk-magnetization of two-sublattices balance each other. For T > T{sub N}, the dc-magnetic susceptibility (χ{sub dc} = M/H{sub dc}) fits well with the Néel's expression for the two-sublattice model with antiferromagnetic molecular field constants N{sub BB} ∼ 15.44, N{sub AB} ∼ 32.01, and N{sub AA} ∼ 20.88. The frequency dependence of ac-magnetic susceptibility χ{sub ac} data follows the Vogel-Fulcher law, and the power-law of critical slowing-down with “zν” = 6.01 suggests the existence of spin-clusters (where “z” and “ν” being dynamic critical-exponent and correlation length of critical-exponent, respectively). This system exhibits unusual hysteresis loops with large bipolar exchange-bias effect (H{sub EB} ∼ 13.6 kOe at 7 K) after zero-field cooling process from an un-magnetized state, and a dramatic collapse of remanence (M{sub R}) and coercive field (H{sub C}) across T{sub COMP}. The possible origins of such anomalous characteristics were discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Short communication: Estimation of yield stress/viscosity of molten octol

Explosive HMX particles are similar in morphology and chemistry to RDX particles, the main constituent of Composition B-3 (Comp B-3). This suggests molten HMX-TNT formulations may show Bingham plasticity, much like recent studies have shown for Comp B-3. Here a Bingham plastic viscosity model, including yield stress and shear thinning, is presented for octol (70/30wt% HMX/TNT) as a function of HMX particle volume fraction. The effect of HMX dissolution into molten TNT is included in this analysis.

36 MATERIALS SCIENCE↗

One dimensional shock initiation of hot isostatically pressed composition B

Twelve one dimensional shock experiments have been carried out on the UK isostatically pressed Composition B (59.5% RDX, 39.5% TNT, 1% wax) comprising of seven sustained pulse experiments and three short shock experiments using the embedded gauge technique at the Los Alamos National Laboratory gas gun facility. The evolution of the reactive growth at and behind the shock front has been measured along with the run to detonation distance. Two low pressure experiments have also been carried out to obtain non-reactive equation of state data. These data have been used to create the Pop plot and Hugoniot states for the UK Comp B. The shock initiation behavior of the UK Comp B has been compared to that of the equivalent US composition. The reactive growth shows a feature that was observed in the US composition in which the wave profiles display a high level of pre-detonation noise. This was hypothesized to be due to a piezoelectric effect in the RDX crystals. The results of these experiments have shown that this effect may be localized in the ε phase at shock pressures in the region of 4.15 GPa and above.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Equation of state measurement of detonation carbon condensates using optical microscopy and interferometry

Thermochemical models of detonation that estimate performance (e.g., detonation velocity, energy delivery, etc.), are based on assumptions that carbon condensates (soot) formed during detonation is largely similar to bulk carbon. However, soot constituents can range from amorphous carbon to nanodiamond and include other material phases. Since thermodynamic properties of the soot such as compressibility are imperative for accurate thermochemical modeling of detonation reaction chemistry, experimental measurements of the equation of state (EOS) which determine the compressibility are vital. Due to the mixed-phase nature of detonation soot, typical methods to measure the EOS (e.g., x-ray diffraction) are untenable. In this study, the high-pressure EOS up to 20 GPa was determined for detonation soot collected from PBX 9502, Composition B (Comp B), Hexanitrostilbene (HNS), and LX-21 high explosives by employing a direct volume technique using optical microscopy and interferometry in a diamond anvil cell. Comp B soot was determined to be the least compressible [K 0 = 57.9(17) GPa] with HNS soot [K 0 = 53.7(15) GPa], LX-21 soot [K 0 = 45.8(51) GPa], and PBX 9502 soot [K 0 = 28.2(27) GPa] being more compressible, likely due to differences in nanodiamond content as compared to amorphous carbon and graphite content.

Amorphous materials↗

High temperature and pressure regime soot: Physical, optical and chemical signatures from high explosive detonations

Submicron particles are formed during the detonation and deflagration of carbon-rich energetic materials known as high explosives (HE) that can be lofted and transported long distances in the atmosphere. Particles include refractory species like soot, a.k.a. black carbon (BC), and have impacts to climate and human health at local, regional, and global scales. Here, we contrast detonation soot aerosol physical, optical and chemical properties that are formed more efficiently in terms of emission factors and ratios with traditional combustion sources from biomass burning and fossil fuels. We utilize ambient aerosol techniques for the first time to identify soot from two well-known HE's (1) Comp B-3: 40% trinitrotoluene (TNT) and 60% 1,3,5-trinitro-1,3,5-triazinane (RDX) and (2) PBX 9501: 95% 1,3,5,7-tetranitro-1,3,5,7-tetrazoctane (HMX) with 2.5% Estane and a 2.5% mixture of bis(2,2-dinitropropyl)-acetal (BDNPA) and bis(2,2-dinitropropyl)-formal (BDNPF). Size distributions, optical and chemical properties are presented. Aggregate soot had small mobility diameters (<100 nm) and unique optical and chemical signatures depending on the explosive composite composition, detonation atmosphere (e.g., air, argon) and pressure. Single-scattering albedos (SSA) from 0.3 to 0.8 and absorption Angstrom exponents (AAE) from 0.5 to 2.0 measured across 405–870 nm wavelengths depended on the explosive composite composition and detonation conditions. Comp B-3 detonation soot was similar to other combustion soot sources, whereas PBX 9501 soot had high scattering relative to absorption. Carbonaceous chemical signatures included the presence of fullerenes that were distinct from ambient and laboratory-generated soot surrogates and the detection of trace metals, including aluminum, copper, iron, and zinc.

36 MATERIALS SCIENCE↗

A NEW DENSITY VARIANCE-MACH NUMBER RELATION FOR SUBSONIC AND SUPERSONIC ISOTHERMAL TURBULENCE

The probability density function of the gas density in subsonic and supersonic, isothermal, driven turbulence is analyzed using a systematic set of hydrodynamical grid simulations with resolutions of up to 1024{sup 3} cells. We perform a series of numerical experiments with root-mean-square (rms) Mach number M ranging from the nearly incompressible, subsonic (M=0.1) to the highly compressible, supersonic (M=15) regime. We study the influence of two extreme cases for the driving mechanism by applying a purely solenoidal (divergence-free) and a purely compressive (curl-free) forcing field to drive the turbulence. We find that our measurements fit the linear relation between the rms Mach number and the standard deviation (std. dev.) of the density distribution in a wide range of Mach numbers, where the proportionality constant depends on the type of forcing. In addition, we propose a new linear relation between the std. dev. of the density distribution {sigma}{sub {rho}} and that of the velocity in compressible modes, i.e., the compressible component of the rms Mach number, M{sub comp}. In this relation the influence of the forcing is significantly reduced, suggesting a linear relation between {sigma}{sub {rho}} and M{sub comp}, independent of the forcing, and ranging from the subsonic to the supersonic regime.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-point inversion of the coronal magnetic field

The Fe XIII 10747 and 10798 Å lines observed in the solar corona are sensitive to the coronal magnetic field in such a way that, in principle, the full vector field at a point on the line of sight can be inferred from their combined polarization signals. This paper presents analytical inversion formulae for the field parameters and analyzes the uncertainty of magnetic field measurements made from such observations, assuming emission dominated by a single region along the line of sight. We consider the case of the current Coronal Multi-channel Polarimeter (CoMP) instrument as well as the future Coronal Solar Magnetism Observatory (COSMO) and Advanced Technology Solar Telescope (ATST) instruments. Uncertainties are estimated with a direct analytic inverse and with a Markov Chain Monte Carlo algorithm. We find that (in effect) two components of the vector field can be recovered with CoMP, and well recovered with COSMO or ATST, but that the third component can only be recovered when the solar magnetic field is strong and optimally oriented.

79 ASTRONOMY AND ASTROPHYSICS↗

THE MAGNETIC STRUCTURE OF SOLAR PROMINENCE CAVITIES: NEW OBSERVATIONAL SIGNATURE REVEALED BY CORONAL MAGNETOMETRY

The Coronal Multi-Channel Polarimeter (CoMP) obtains daily full-Sun above-the-limb coronal observations in linear polarization, allowing, for the first time, a diagnostic of the coronal magnetic field direction in quiescent prominence cavities. We find that these cavities consistently possess a characteristic 'lagomorphic' signature in linear polarization indicating twist or shear extending up into the cavity above the neutral line. We demonstrate that such a signature may be explained by a magnetic flux-rope model, a topology with implications for solar eruptions. We find corroborating evidence for a flux-rope structure in the pattern of concentric rings within cavities seen in CoMP line-of-sight velocity.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-194: From Dicom-RT to Radiobiological Dose Metrics in 5 Minutes

Purpose: To develop a flexible and standalone framework for batch calculation of radiobiological dose metrics from Dicom-RT. Methods: Software has been developed which allows (1) The calculation of DVH data from DICOM dose and structure files (DVHgenerator), (2) Calculation of a wide range of radiobiological metrics from this data (CompPlanGui). Both these tools are run via graphical user interface (GUI), making them fast and simple. Part 1 is a new tool which has not previously been published, whilst part 2 is a GUI overlay for the previously published software ‘Comp-Plan’ (Holloway et. al., Medical Dosimetry, 2012), previously reliant on command line interface. The time taken for an experienced user to evaluate a test case of 6 plans with and without CompPlanGUI was quantified. Results: The DVH-generator has been found to be faster, more robust and require far less physical memory then using alternative software solutions for the same purpose. The Comp Plan GUI significantly reduces the amount of time required to set up a base directory, eliminates code crashes arising from typographical errors, and renders the code far more accessible to non-expert users. It took an experienced user of the code around 3 minutes to set up a base directory of 6 plans compared around 8 minutes without, indicating that using CompPlanGUI reduced setup time by over 50%. Conclusion: A standalone GUI based framework has developed which allows for the batch calculation of radiobiological dose metrics directly from Dicom-RT files. As with the original code, this work will be made freely available on request, as well as via matlab file exchange.

07 ISOTOPE AND RADIATION SOURCES↗

Sci-Fri AM: Quality, Safety, and Professional Issues 01: CPQR Technical Quality Control Suite Development including Quality Control Workload Results

A close partnership between the Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) has resulted in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. The framework includes consolidation of existing guidelines and/or literature by expert reviewers, structured stages of public review, external field-testing and ratification by COMP. The adopted framework for the development and maintenance of the TQCs ensures the guidelines incorporate input from the medical physics community during development, measures the workload required to perform the QC tests outlined in each TQC, and remain relevant (i.e. “living documents”) through subsequent planned reviews and updates. This presentation will show the Multi-Leaf Linear Accelerator document as an example of how feedback and cross-national work to achieve a robust guidance document. During field-testing, each technology was tested at multiple centres in a variety of clinic environments. As part of the defined feedback, workload data was captured. This lead to average time associated with testing as defined in each TQC document. As a result, for a medium-sized centre comprising 6 linear accelerators and a comprehensive brachytherapy program, we evaluate the physics workload to 1.5 full-time equivalent physicist per year to complete all QC tests listed in this suite.

60 APPLIED LIFE SCIENCES↗

A Multiscale Modeling Approach to Analyze Filament-Wound Composite Pressure Vessels

A multiscale modeling approach to analyze filament-wound composite pressure vessels is developed in this article. The approach, which extends the Nguyen et al. model [J. Comp. Mater. 43 (2009) 217] developed for discontinuous fiber composites to continuous fiber ones, spans three modeling scales. The microscale considers the unidirectional elastic fibers embedded in an elastic-plastic matrix obeying the Ramberg-Osgood relation and J2 deformation theory of plasticity. The mesoscale behavior representing the composite lamina is obtained through an incremental Mori-Tanaka type model and the Eshelby equivalent inclusion method [Proc. Roy. Soc. Lond. A241 (1957) 376]. The implementation of the micro-meso constitutive relations in the ABAQUS® finite element package (via user subroutines) allows the analysis of a filament-wound composite pressure vessel (macroscale) to be performed. Failure of the composite lamina is predicted by a criterion that accounts for the strengths of the fibers and of the matrix as well as of their interface. The developed approach is demonstrated in the analysis of a filament-wound pressure vessel to study the effect of the lamina thickness on the burst pressure. The predictions are favorably compared to the numerical and experimental results by Lifshitz and Dayan [Comp. Struct. 32 (1995) 313].

Filament-wound composite, pressure vessel, multisc↗

Design of Temperature Dependent Critical Experiments with SPRF/CX

This paper describes the investigation of temperature-dependent critical experiments using the Seven Percent Critical Experiments (7uPCX) and Burnup Credit Critical Experiments (BUCCX) fuel types within the Sandia Pulsed Reactor Facility/Critical Experiments (SPRF/CX) apparatus at Sandia National Laboratories (Sandia). The goal of these experiments is to test the effect of varying system temperature on the $\kappa$ eff bias of water-moderated systems. Temperatures of 5–95°C were considered in this work. Eighteen representative lattice configurations were analyzed that had variations in the number of fuel rods and water holes, as well as in the array configuration, to achieve a variety of moderation regimes. The configurations were based on those detailed in the LEU-COMP-THERM-078 and LEU- COMP-THERM-079 experiments, both of which were published in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗