Erratum: Cold Neutron Energy Dependent Production of Ultracold Neutrons in Solid Deuterium [Phys. Rev. Lett. 99, 262502 (2007)]
No abstract prepared.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
The breadth of experiments performed using slow neutrons continues to increase worldwide. The accomplishments are a result of strong collaborations among national laboratories and university-based scientists and their students. There have been a growing number of notable results in fundamental neutron physics over the course of the last three-year grant period. A number of these experiments have been carried out on the beamlines at NIST or with the participation of NIST researchers. The list below gives a brief summary of some of these results as well as some of the cooperative endeavors during the last grant period.
As part of the Sustaining and Enhancing Nuclear Science (SENSe) initiative at Oak Ridge National Laboratory (ORNL), the prospect of adding new detection systems to support High Flux Isotope Reactor (HFIR) operations and to advance scientific research has prompted many ideas and discussions regarding potential features, configurations, locations, and applications. A working group of ORNL staff members was organized to further develop the concepts and recommending one or more configurations to best support future HFIR operations and scientific capacities and to provide order-of-magnitude cost estimates and timing. The areas of investigation included fast access detection systems, non-scattering beamline instruments, shielded detection instruments, and an ultracold neutron source. In each case, the focus was to develop world leading capabilities that would be unmatched by any other facility.
Abstract Not Provided
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Cold neutron sources of reactors and spallation neutron sources are classic high flux neutron sources in operation all over the world. Cryogenic fluids such as supercritical or supercooled hydrogen are commonly selected as a moderator to absorb the nuclear heating from proton beams. By comparing supercritical hydrogen circulation systems and supercooled hydrogen circulation systems, the merits and drawbacks in both systems are summarized. When supercritical hydrogen circulates as the moderator, severe pressure fluctuations caused by temperature changes will occur. The pressure control system used to balance the system pressure, which consists of a heater as an active controller for thermal compensation and an accumulator as a passive volume controller, is preliminarily studied. The results may provide guidelines for design and operation of other cryogenic hydrogen system for neutron sources under construction.
Jack Carpenter, pioneer of accelerator-based pulsed spallation neutron sources, talks about neutron science at Oak Ridge National Laboratory (ORNL) and a need for a second target station at the Spallation Neutron Source (SNS). ORNL is the Department of Energy's largest multiprogram science and energy laboratory, and is home to two scientific user facilities serving the neutron science research community: the High Flux Isotope Reactor (HFIR) and SNS. HFIR and SNS provide researchers with unmatched capabilities for understanding the structure and properties of materials, macromolecular and biological systems, and the fundamental physics of the neutron. Neutrons provide a window through which to view materials at a microscopic level that allow researchers to develop better materials and better products. Neutrons enable us to understand materials we use in everyday life. Carpenter explains the need for another station to produce long wavelength neutrons, or cold neutrons, to answer questions that are addressed only with cold neutrons. The second target station is optimized for that purpose. Modern technology depends more and more upon intimate atomic knowledge of materials, and neutrons are an ideal probe.
Measurements of the cold neutron spectrum from the super critical hydrogen cold source at the High Flux Isotope Reactor at Oak Ridge National Laboratory were made using time-of-flight spectroscopy. Data were collected at reactor power levels of 8.5MW, 42.5MW and 85MW. The moderator temperature was also varied. Data were collected at 17K and 25K while the reactor power was at 8.5MW, 17K and 25K while at 42.5MW and 18K and 22K while at 85MW. The purpose of these measurements was to characterize the brightness of the cold source and to better understand the relationship between reactor power, moderator temperature, and cold neutron production. The authors will discuss the details of the measurement, the changes observed in the neutron spectrum, and the process for determining the source brightness from the measured neutron intensity.
Project Summary: Company: Adelphi Technology, Inc., Redwood City, CA 94063-4121 DOE Phase 1 STTR PI: Dr. Jay Theodore Cremer, Jr. Chief Scientist at Adelphi Technology, Inc. DOE Phase 1 STTR with: Dr. Boris Khaykovich of Massachusetts Institute of Technology (MIT) MIT Nuclear Reactor Laboratory DOE Phase 1 STTR Title: Axisymmetric and Focusing Analyzers to Enable Efficient Powder and Residual Stress Neutron Diffractometers Statement of the problem or situation that is being addressed: Although thermal and cold neutron scattering is widely used, and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed, so as to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed: We strive to achieve the goal of efficient use of available thermal and cold neutrons, by introducing here, novel analyzers for powder diffraction and stress-strain measurements. These analyzers will enable polychromatic cold and thermal neutron diffractometers, which will have much higher throughput than existing instruments. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast instruments for screening of multiple samples, for measuring kinetic processes, or for measuring residual stress tensors. Commercial Applications and Other Benefits: By combining the novel analyzers with the Adelphi thermal neutron generator, we will open a new market, which includes the testing of samples that cannot be transported, such as nuclear fuels, or the testing of parts during production. Given the reasonable cost and size of our proposed analyzer systems, along with the continuing development of more powerful thermal neutron generators, the proposed analyzers will be suitable for weak neutrons sources, which are installed at small to large university, industrial, and government laboratories. Key Words: Neutron powder diffraction, residual stress measurements, thermal neutron generators, TRIGA reactors, low flux thermal and cold neutron sources, neutron diffraction. Summary for Members of Congress: Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.
We calculate the cold neutron-deuteron (nd) capture cross section,σ nd to next-to-next-to leading order (NNLO) using the model-independent approach of pionless effective-field theory [EFT(π)]. At leading order we find σ nd = 0.314 ± 0.217 mb, while the experimental result is 0.508(15) mb for a laboratory neutron velocity of 2200 m/s. At next-to-leading-order (NLO), we show that σnd is sensitive to the low-energy constant (LEC) $L$$^{(0)}_{1}$ of the two-nucleon isovector current appearing at NLO. A fit of $L$$^{(0)}_{1}$ at NLO to the triton magnetic moment yields a NLO prediction of σ nd = 0.393 ± 0.164 mb, where the error comes from propagating the error from the $L$$^{(0)}_{1}$ fit. At NNLO, we find that a new three-nucleon magnetic moment counterterm is required for renormalization-group invariance of both σnd and the triton magnetic moment. Fitting the NNLO correction to $L$$^{(0)}_{1}$ (denoted $L$$^{(1)}_{1}$) to cold neutron-proton capture (σnp) yields a NNLO prediction of σ nd = 0.447 ± 0.130 mb, where the error comes from propagating the error from the $L$$^{(1)}_{1}$ fit. We also study different fittings of $L$$^{(0)}_{1}$ and $L$$^{(1)}_{1}$ to σ np , σ nd , and/or the triton magnetic moment. For example, fitting $L$$^{(0)}_{1}$ simultaneously to σ np , σ nd , and the triton magnetic moment at NLO, and fitting $L$$^{(1)}_{1}$ simultaneously to σ np and σnd at NNLO, yields σ nd = 0.480 ± 0.114 mb and 0.511 ± 0.042 mb, respectively, where errors are naively estimated from EFT(π) power counting. Additionally, we discuss how Wigner SU(4) symmetry may alter the naive EFT(π) expansion of σ nd .
At the new research reactor FRM II in Garching near Munich the beam guide with the highest cold neutron flux is dedicated to Prompt Gamma-ray Activation Analysis (PGAA) and related neutron capture experiments. We have designed a partially ballistic form of the neutron guide with the aim of concentrating the cold neutrons at the target position of the PGAA experiment. The cold neutron flux with a mean energy of only 1.83 meV was measured about 10.5 cm far from the second exit window and reached intensity of 1.7x10{sup 10} n/cm{sup 2} s at a 2 mmx2 mm gold foil. The PGAA installation is now prepared for three different kinds of measurements--standard PGAA, Neutron Tomography of small samples and position sensitive PGAA, or PGAI for short. We have also measured {gamma}{gamma} coincidences in {sup 77}Ge. In this paper, we want to introduce the PGAA facility, show the diversity of the recently performed experiments and discuss further possibilities.
A new Radiochemistry Education and Research Program was started at the Pennsylvania University, Radiation Science and Engineering Center. The program was initially supported by the Department of Energy, Radiochemistry Education Award Program (REAP). Using REAP funding as leverage we obtained support from the Los Alamos National Laboratory, Department of Homeland Security, Domestic Nuclear Detection Office, various internal funding from PSU and other entities. The PSU radiochemistry program primarily addresses radiochemistry education and secondarily nuclear and radiochemistry research. The education program consists of bolstering our existing radiochemistry and related courses; Nuclear and Radiochemistry, Radiation Detection and Measurement, Radiological Safety and developing new courses, e.g., Laboratory Experiments in Applied Nuclear and Radiochemistry, and Nuclear Methods in Science. A new laboratory has been created with state of the art equipment for the Laboratory Experiments in Applied Nuclear and Radiochemistry course. We also plan to revitalize the nuclear and radiochemistry research programs. We established a state-of-the-art Neutron Activation Analysis Laboratory and a gamma ray spectroscopy laboratory that has 10 stations including state-of-the-art nuclear spectroscopy hardware and software. In addition, we embarked on an expansion plan that included building a new neutron beam hall and neutron beam ports with a cold neutron source. One of the reasons to have a cold neutron source is for the development of a prompt gamma activation analysis facility. A detailed description of PSU radiochemistry education and research program will be given and the future plans will be discussed.
Non-streaming high-efficiency perforated semiconductor neutron detectors, method of making same and measuring wands and detector modules utilizing same are disclosed. The detectors have improved mechanical structure, flattened angular detector responses, and reduced leakage current. A plurality of such detectors can be assembled into imaging arrays, and can be used for neutron radiography, remote neutron sensing, cold neutron imaging, SNM monitoring, and various other applications.
Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.
A comparative analysis of the results obtained by experimentally and theoretically studying T-odd asymmetries for various third particles in the true and delayed ternary nuclear fission induced by cold polarized neutrons was performed. It was confirmed that the appearance of these asymmetries was associated with the effect of rotation of a polarized system undergoing fission on the angular distributions of prescission and evaporated third particles with respect to the direction along which the emerging fission fragments flew apart, this effect being determined by the Coriolis interaction of the rotational and the internalmotion of the fissioning system. A quantum-mechanical description of particle motion in a rotating coordinate system was generalized to the case where gamma-ray emission was present. It was shown that the separation of the motions of an axially symmetric fissile system into a rotational and an internal motion was valid in the external region as well, where ternary-fission products had already been formed, if it was considered that the motion of fission fragments was tightly connected with the system symmetry axis, which rotated in the laboratory frame. It was found that the dependence of the fissile-system moment of inertia appearing in the Coriolis interaction Hamiltonian on the distance between the fission fragments flying apart generated an additional phase in the amplitude of the radial distribution of fission fragments. It was shown that this phase might change sizably the contribution of the interference between fission amplitudes of neutron resonances excited in a fissile compound nucleus to the absolute values of T -odd asymmetries, especially for third particles such as neutrons and photons, which interacted only slightly with fission fragments.
The cold polycrystalline beryllium reflector-filter concept has been used to enhance the cold neutron emission of cryogenic hydrogen moderators, while suppressing the intermediate wavelength and fast neutron emission at the same time. While suppressing the fast neutron emission is often desired, the suppression of intermediate wavelength neutrons is often unwelcome. It has been hypothesized that replacing the polycrystalline reflector-filter concept with a single-crystal reflector-filter concept would overcome the suppression of intermediate wavelength neutrons and thereby extend the usability of the reflector-filter concept to shorter but still important wavelengths. In this paper we present the first experimental data on a single-crystal reflector-filter and compare experimental results with hypothesized performance. We find that a single-crystal reflector-filter retains the long-wavelength benefit of the polycrystalline reflector-filter, without suffering the same loss of important intermediate wavelength neutrons. Ultimately, this finding extends the applicability of the reflector-filter concept to intermediate wavelengths, and furthermore indicates that the reflector-filter benefits arise from its interaction with fast (background) neutrons, not with intermediate wavelength neutrons of potential interest in many types of neutron scattering.
A research program aimed at studying fundamental interactions by means of ultracold and polarized cold neutrons at the GEK-4-4′ channel of the PIK reactor is presented. The apparatus to be used includes a source of cold neutrons in the heavy-water reflector of the reactor, a source of ultracold neutrons based on superfluid helium and installed in a cold-neutron beam extracted from the GEK-4 channel, and a number of experimental facilities in neutron beams. An experiment devoted to searches for the neutron electric dipole moment and an experiment aimed at a measurement the neutron lifetime with the aid of a large gravitational trap are planned to be performed in a beam of ultracold neutrons. An experiment devoted to measuring neutron-decay asymmetries with the aid of a superconducting solenoid is planned in a beam of cold polarized neutrons from the GEK-4′ channel. The second ultracold-neutron source and an experiment aimed at measuring the neutron lifetime with the aid of a magnetic trap are planned in the neutron-guide system of the GEK-3 channel. In the realms of neutrino physics, an experiment intended for sterile-neutrino searches is designed. The state of affairs around the preparation of the experimental equipment for this program is discussed.