Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CODES AND STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Path Forward: Materials Data Modernization for ASME Codes and Standards in the Artificial Intelligence Era

Development of the ASME Materials Properties Database was initiated in the early 2010s to support the ASME Codes and Standards. As information technologies advance at an accelerated pace with the artificial intelligence era on the horizon, the ASME Materials Properties Database must be further modernized from a database to a knowledgebase to ride the wave of digital information revolution and effectively support the ASME Codes and Standards in the new era.This paper is intended to provide an overview of the ASME Materials Properties Database and discuss a roadmap for its future development to facilitate understanding of and participation from different sectors of the Codes and Standards community. It first reviews the basic concepts of data, information, knowledge, database, and database system; as well as the pros and cons in different types of data management, and then discusses the path forward for a desired evolution of the database into a self-explanatory and machine-readable knowledgebase that is consistent with human cognitive processes for the Codes and Standards development and furthermore provides resources for data processing and analysis to reach an eventual goal of streamlining the Codes and Standards development from the initial inquiry, throughout data submission, analysis, …, to Codes and Standards rule establishment for final publication.

Ren, Weiju↗

Complete Decoding and Reporting of Aviation Routine Weather Reports (METARs)

Aviation Routine Weather Report (METAR) provides surface weather information at and around observation stations, including airport terminals. These weather observations are used by pilots for flight planning and by air traffic service providers for managing departure and arrival flights. The METARs are also an important source of weather data for Air Traffic Management (ATM) analysts and researchers at NASA and elsewhere. These researchers use METAR to correlate severe weather events with local or national air traffic actions that restrict air traffic, as one example. A METAR is made up of multiple groups of coded text, each with a specific standard coding format. These groups of coded text are located in two sections of a report: Body and Remarks. The coded text groups in a U.S. METAR are intended to follow the coding standards set by National Oceanic and Atmospheric Administration (NOAA). However, manual data entry and edits made by a human report observer may result in coded text elements that do not follow the standards, especially in the Remarks section. And contrary to the standards, some significant weather observations are noted only in the Remarks section and not in the Body section of the reports. While human readers can infer the intended meaning of non-standard coding of weather conditions, doing so with a computer program is far more challenging. However such programmatic pre-processing is necessary to enable efficient and faster database query when researchers need to perform any significant historical weather analysis. Therefore, to support such analysis, a computer algorithm was developed to identify groups of coded text anywhere in a report and to perform subsequent decoding in software. The algorithm considers common deviations from the standards and data entry mistakes made by observers. The implemented software code was tested to decode 12 million reports and the decoding process was able to completely interpret 99.93 of the reports. This document presents the deviations from the standards and the decoding algorithm. Storing all decoded data in a database allows users to quickly query a large amount of data and to perform data mining on the data. Users can specify complex query criteria not only on date or airport but also on weather condition. This document also describes the design of a database schema for storing the decoded data, and a Data Warehouse web application that allows users to perform reporting and analysis on the decoded data. Finally, this document presents a case study correlating dust storms reported in METARs from the Phoenix International airport with Ground Stops issued by Air Route Traffic Control Centers (ATCSCC). Blowing widespread dust is one of the weather conditions when dust storm occurs. By querying the database, 294 METARs were found to report blowing widespread dust at the Phoenix airport and 41 of them reported such condition only in the Remarks section of the reports. When METAR is a data source for an ATM research, it is important to include weather conditions not only from the Body section but also from the Remarks section of METARs.

METAR Decoder/Parser↗

Inventory of Safety-related Codes and Standards for Energy Storage Systems with some Experiences related to Approval and Acceptance

The purpose of this document is to identify laws, rules, model codes, codes, standards, regulations, specifications (CSR) related to safety that could apply to stationary energy storage systems (ESS) and experiences to date securing approval of ESS in relation to CSR. This information is intended to assist in securing approval of ESS under current CSR and to identification of new CRS or revisions to existing CRS and necessary supporting research and documentation that can foster the deployment of safe ESS.

Conover, David R.↗

High Temperature Gas Reactors: Assessment of Applicable Codes and Standards

Current interest expressed by industry in HTGR plants, particularly modular plants with power up to about 600 MW(e) per unit, has prompted NRC to task PNNL with assessing the currently available literature related to codes and standards applicable to HTGR plants, the operating history of past and present HTGR plants, and with evaluating the proposed designs of RPV and associated piping for future plants. Considering these topics in the order they are arranged in the text, first the operational histories of five shut-down and two currently operating HTGR plants are reviewed, leading the authors to conclude that while small, simple prototype HTGR plants operated reliably, some of the larger plants, particularly Fort St. Vrain, had poor availability. Safety and radiological performance of these plants has been considerably better than LWR plants. Petroleum processing plants provide some applicable experience with materials similar to those proposed for HTGR piping and vessels. At least one currently operating plant - HTR-10 - has performed and documented a leak before break analysis that appears to be applicable to proposed future US HTGR designs. Current codes and standards cover some HTGR materials, but not all materials are covered to the high temperatures envisioned for HTGR use. Codes and standards, particularly ASME Codes, are under development for proposed future US HTGR designs. A 'roadmap' document has been prepared for ASME Code development; a new subsection to section III of the ASME Code, ASME BPVC III-5, is scheduled to be published in October 2011. The question of terminology for the cross-duct structure between the RPV and power conversion vessel is discussed, considering the differences in regulatory requirements that apply depending on whether this structure is designated as a 'vessel' or as a 'pipe'. We conclude that designing this component as a 'pipe' is the more appropriate choice, but that the ASME BPVC allows the owner of the facility to select the preferred designation, and that either designation can be acceptable.

02 PETROLEUM↗

An international review of occupant-related aspects of building energy codes and standards

In light of recent research, it is evident that occupants are playing an increasingly important role in building energy performance. Furthermore, despite the important role of building energy codes and standards in design, the occupant-related aspects are typically simple and have not kept up with the leading research. This paper reviews 23 regions’ building energy codes and standards by first comparing their quantitative aspects and then analyzing their mandated rules and approaches. While the present paper focuses on offices, general recommendations are applicable to other building types as well. The review revealed a wide range of occupant-related values, approaches, and attitudes. For example, code-specified occupant density varies by nearly a factor of three between different codes. This underlines the need for development of advancement in occupant behavior modeling approaches for future occupant-centric building performance codes and standards. Moreover, occupants are often referred to only implicitly; underlying expectations about energy-saving occupant behavior from building occupants varies greatly; and, only a few codes address occupant feedback and system usability. Based on the findings of the review, a set of initial recommendations for future building energy codes is proposed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Set of Hydrogen Codes and Standards for the US (Presentation)

The US has a national set of codes and standards that address the use of hydrogen technologies. These documents are published by several organizations and are not all directly adopted by government authorities. The US Department of Energy (DOE) has acted as the central organizing group to identify these documents and present them as a coherent and integrated set of requirements.

08 HYDROGEN↗

Energy Storage System Safety Documenting and Validating Compliance with Codes and Standards

Energy, environmental, and economic challenges are spurring more widespread consideration and use of energy storage systems (ESSs), which in turn are driving increased development of new ways to store energy electrochemically, mechanically, and thermally. These new methods necessitate an increased focus on ensuring that public health, safety, and welfare are not adversely affected—something that has been addressed for many years through codes, standards, and regulations (CSR5)1. CSRs provide requirements that establish a basis for determining if an ESS is safe, whether electrochemical, mechanical, or thermal and regardless of the range of ESS applications, energy capacities, physical sizes, location, or number installed at any given site. The key to achieving desired safety goals, as memorialized through CSRs, is through documenting and validating compliance with applicable CSRs. The process of documenting and validating compliance, which is a key component to the initial approval as well as continuing acceptance of an ESS installation, is generally called conformity assessment.

25 ENERGY STORAGE↗

Safety Codes and Standards Review and Gap Analysis for Applicability to Hydrogen Rail Refueling, Defueling, Maintenance, and Storage

Hydrogen-powered locomotives may present an alternative to diesel for achieving transportation-related decarbonization, energy security, and resilience goals. As an emerging technology, hydrogen locomotives may not have adequate representation in current safety codes and standards. NFPA 2 and other appropriate codes and standards were reviewed to identify technical gaps in the code for hydrogen rail defueling, refueling, maintenance, and storage. Several technical gaps pertaining to setback distances, allowable quantities, ventilation rates, and grounding have been identified. Fueling requirements can be informed by road vehicle standards but may need to be revised for larger quantity hydrogen locomotive systems. Since there are no hydrogen-specific locomotive design and safety standards, some aspects of diesel-based locomotive standards may apply. CGA G- 5.5 currently provides the most guidance on height, placement, orientation, and design of vent systems, while other standards emphasize the importance of shielding vent stacks and provide requirements for orientation of their discharge.

08 HYDROGEN↗

A new code for Galileo

Over the past six to eight years, an extensive research effort was conducted to investigate advanced coding techniques which promised to yield more coding gain than is available with current NASA standard codes. The delay in Galileo's launch due to the temporary suspension of the shuttle program provided the Galileo project with an opportunity to evaluate the possibility of including some version of the advanced codes as a mission enhancement option. A study was initiated last summer to determine if substantial coding gain was feasible for Galileo and, is so, to recommend a suitable experimental code for use as a switchable alternative to the current NASA-standard code. The Galileo experimental code study resulted in the selection of a code with constant length 15 and rate 1/4. The code parameters were chosen to optimize performance within cost and risk constraints consistent with retrofitting the new code into the existing Galileo system design and launch schedule. The particular code was recommended after a very limited search among good codes with the chosen parameters. It will theoretically yield about 1.5 dB enhancement under idealizing assumptions relative to the current NASA-standard code at Galileo's desired bit error rates. This ideal predicted gain includes enough cushion to meet the project's target of at least 1 dB enhancement under real, non-ideal conditions.

Dolinar, S.↗

Safety, codes and standards for hydrogen installations. Metrics development and benchmarking

Automakers and fuel providers have made public commitments to commercialize light duty fuel cell electric vehicles and fueling infrastructure in select US regions beginning in 2014. The development, implementation, and advancement of meaningful codes and standards is critical to enable the effective deployment of clean and efficient fuel cell and hydrogen solutions in the energy technology marketplace. Metrics pertaining to the development and implementation of safety knowledge, codes, and standards are important to communicate progress and inform future R&D investments. This document describes the development and benchmarking of metrics specific to the development of hydrogen specific codes relevant for hydrogen refueling stations. These metrics will be most useful as the hydrogen fuel market transitions from pre-commercial to early-commercial phases. The target regions in California will serve as benchmarking case studies to quantify the success of past investments in research and development supporting safety codes and standards R&D.

08 HYDROGEN↗

Codes and Standards Update: February 2019

The goal of the DOE OE Energy Storage System Safety Roadmap is to foster confidence in the safety and reliability of energy storage systems. There are three interrelated objectives to support the realization of that goal: research, codes and standards(C/S)and communication/coordination. The objective focused on C/S is "To apply research and development to support efforts that refocused on ensuring that codes and standards are available to enable the safe implementation of energy storage systems in a comprehensive, non-discriminatory and science-based manner." The following activities support that objective and realization of the goal: (a.) Review and assess C/S which affect the design, installation, and operation of energy storage systems(ESS). (b.) Identify gaps in knowledge that require research and analysis that can serve as a basis for criteria in those C/S. (c.) Identify areas in C/S that are potentially in need of revision or enhancement and can benefit from activities conducted under research and development. (d.) Develop input for new or revisions to existing C/S through individual stakeholders, facilitated task forces, or through laboratory staff supporting these efforts. The purpose of this Codes and Standards Update is to support the above activities by providing information on efforts being conducted by U.S. standards developing organizations(SDOs)and other entities that are focused on ESS safety. The information is organized relative to the scope of each document in relation to ESS from the "macro to the micro"(e.g., from overarching covering considerable scope ,to installation specific, to ESS and then ESS components). Note that more macro documents are also likely to adopt by reference more micro documents.

25 ENERGY STORAGE↗

Standard Lexicons, Coding Systems and Ontologies for Interoperability and Semantic Computation in Imaging

Standard clinical terms, codes, and ontologies promote clarity and interoperability. Within radiology, there is a variety of relevant content resources, tools and technologies. These provide the basis for fundamental imaging workflows such as reporting and billing, and also facilitate a range of applications in quality improvement and research. This article reviews the key characteristics of lexicons, coding systems, and ontologies. A number of standards are described, including International Classification of Diseases-10-Clinical Modification (ICD-10-CM), Current Procedural Terminology (CPT), Systematized Nomenclature of Medicine—Clinical Terms (SNOMED CT), Logical Observation Identifiers Names and Codes (LOINC), and RadLex. Tools for accessing this material are reviewed, such as the National Center for Biomedical Ontology BioPortal system. Web services are discussed as a mechanism for semantic application development. Several example systems, workflows, and research applications using semantic technology are also surveyed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regulations, Codes, and Standards (RCS) for Multi-Fuel Motor Vehicle Dispensing Stations

In the United States, requirements for liquid motor vehicle fuelling stations have been in place for many years. Requirements for motor vehicle fuelling stations for gaseous fuels, including hydrogen, are relatively new. These requirements have, in the United States, been developed along different code and standards paths. The liquid fuels have been addressed in a single document and the gaseous fuels have been addressed in documents specific to an individual gas. The result of these parallel processes is that multi-fuel stations are subject to requirements in several fuelling regulations, codes, and standards (RCS). This paper describes a configuration of a multi-fuel motor vehicle fuelling station and provides a detailed breakdown of the codes and standards requirements. The multi-fuel station would dispense what the U.S. Department of Energy defines as the six key alternative fuels: biodiesel, electricity, ethanol, hydrogen, natural gas, and propane. The paper will also identify any apparent gaps in RCS and potential research projects that could help fill these gaps.

33 ADVANCED PROPULSION SYSTEMS↗

Codes and Standards Assessment for Hydrogen Blends into the Natural Gas Infrastructure

Energy utilities are evaluating emerging energy technologies to reduce reliance on carbon as an energy carrier. Hydrogen has been identified as a potential substitute for carbon-based fuels that can be blended into other gaseous energy carriers, such as natural gas. However, hydrogen blending into natural gas has important implications on safety which need to be evaluated. Designers and installers of systems that utilize hydrogen gas blending into natural gas distribution systems need to adhere to local building codes and engage with the authority having jurisdiction (AHJ) for safety and permitting approvals. These codes and standards must be considered to understand where safety gaps might be apparent when injecting hydrogen into the natural gas infrastructure. This report generates a list of relevant codes and standards for hydrogen blending on existing, upgraded, or new pipelines. Additionally, a preliminary assessment was made to identify the codes and standards that need to be modified to enable this technology as well as potential gaps due to the unique nature and safety concerns of gaseous hydrogen.

03 NATURAL GAS↗