Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CO2 monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Carbon Monitoring System Flux Estimation and Attribution: Impact of ACOS-GOSAT X(CO2) Sampling on the Inference of Terrestrial Biospheric Sources and Sinks

Using an Observing System Simulation Experiment (OSSE), we investigate the impact of JAXA Greenhouse gases Observing SATellite 'IBUKI' (GOSAT) sampling on the estimation of terrestrial biospheric flux with the NASA Carbon Monitoring System Flux (CMS-Flux) estimation and attribution strategy. The simulated observations in the OSSE use the actual column carbon dioxide (X(CO2)) b2.9 retrieval sensitivity and quality control for the year 2010 processed through the Atmospheric CO2 Observations from Space algorithm. CMS-Flux is a variational inversion system that uses the GEOS-Chem forward and adjoint model forced by a suite of observationally constrained fluxes from ocean, land and anthropogenic models. We investigate the impact of GOSAT sampling on flux estimation in two aspects: 1) random error uncertainty reduction and 2) the global and regional bias in posterior flux resulted from the spatiotemporally biased GOSAT sampling. Based on Monte Carlo calculations, we find that global average flux uncertainty reduction ranges from 25% in September to 60% in July. When aggregated to the 11 land regions designated by the phase 3 of the Atmospheric Tracer Transport Model Intercomparison Project, the annual mean uncertainty reduction ranges from 10% over North American boreal to 38% over South American temperate, which is driven by observational coverage and the magnitude of prior flux uncertainty. The uncertainty reduction over the South American tropical region is 30%, even with sparse observation coverage. We show that this reduction results from the large prior flux uncertainty and the impact of non-local observations. Given the assumed prior error statistics, the degree of freedom for signal is approx.1132 for 1-yr of the 74 055 GOSAT X(CO2) observations, which indicates that GOSAT provides approx.1132 independent pieces of information about surface fluxes. We quantify the impact of GOSAT's spatiotemporally sampling on the posterior flux, and find that a 0.7 gigatons of carbon bias in the global annual posterior flux resulted from the seasonally and diurnally biased sampling when using a diagonal prior flux error covariance.

biased sampling↗

The INSTEP Monitoring Network: Merging High-and-Low Cost Measurements to Characterize California Wildfires

Despite challenges with data quality and scope, low-cost sensor networks have skyrocketed in popularity over the last 15 years, making air quality data available on refined spatial scales. More recently, studies have leveraged both high and low-quality instruments to create stronger “hybrid” models, with most studies focusing on particulate matter. Low-cost measurements typically represent ground-level emissions only, providing context for human health issues from climate change-driven events such as wildfires. Since low-cost sensors’ capabilities are localized, daily events and microclimates tend to dominate the data rather than larger regional or atmospheric trends. Likewise, their low cost explains their high uncertainty. In contrast, some regulatory-grade instruments produce column measurements as well, providing reliable information on a broader scope. To bridge this gap while expanding into gas-phase measurements, we deployed 12 air quality sensor packages in California, USA during the 2022 wildfire season. These INSTEP (Inexpensive Network Sensor Technology Exploring Pollution) monitors measure carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2), and several hydrocarbons including methane (CH4) and formaldehyde (HCHO). Half of the monitors were co-located with remote sensing spectrometers: NASA Pandora and Total Column Carbon Observing Network (TCCON). The overlap in pollutants includes NO2, O3, and HCHO between the INSTEP monitors and the Pandora column measurements. TCCON covers column CO, CO2, and CH4, rounding out our comparison. Most of the monitors were distributed throughout the San Francisco Bay area, and an additional three were located within 100 km of Los Angeles. The sites ranged in geographic and population characteristics, including desert, mountainous, coastal, and urban locations. Since varying environmental conditions such as temperature and pressure are known to challenge sensor performance, we will apply newer sensor “calibration” techniques meant to combat this. We will normalize our sensor signals by z-scoring them prior to applying a single calibration model in the form of multivariate linear regression or an artificial neural network. While this technique has been validated for the hydrocarbon and ozone sensor types (metal oxide), it has not yet been tested on electrochemical and non-dispersive infrared sensors, which are also used in the INSTEP monitors. This will serve as a test to see if this normalization technique – or another – is most effective in accounting for environmental differences among sensors. Related data analysis efforts have found success with a variety of geospatial analysis techniques, including weighted network models in which high-quality instruments are given higher weights than their low-cost counterparts. Our preliminary analysis will focus on kriging, which uses a Gaussian algorithm to assign weights, providing estimated pollution levels at locations between monitors. Smoke trajectory and evolution will also be considered using both measurement types. We also aim to baseline subtract our emission estimates from each region to determine which portion of emissions are regional and local, further characterizing burn differences in northern and southern California fires. Future directions include using INSTEP jointly with TEMPO satellite data, and mobile deployments on aircraft and uncrewed aerial vehicles (UAV).

Low-cost sensors↗

Approaches to the utilization of space for CO2 research

A system study of the potential of space technology to monitor climate changes and improve the understanding of the coupling beteen CO2 and cloud cover is summarized. The basis for the study is scientific data requirements pertinent to the U.S. Department of Energy's CO2 Research Program. The capabilities of space-based sensor systems are matched to meet these requirements. New sensor system concepts are identified, including a Space Shuttle-launched recalibration package to provide for continuity of measurement and recalibration between satellites, a high-orbit radiation budget satellite, or parallax sensor to measure cloud altitude, a passive method for the direct measurements of CO2 and a high-altitude powered platform to monitor select regional parameters. Space-based sensor systems that could be the development focus for the time frames of 0-5, 5-10 and 10-20 years are recommended.

Glaser, P.↗

Compact Multi-Channel Infrared Laser Absorption Spectrometer for Spacecraft Fire Safety Monitoring

We report on the design of a six-channel tunable laser absorption spectroscopy instrument for measuring ambient gas-phase concentrations of CO, HCl, HCN, HF, CO2, and O2 in spacecraft environments. Monitoring of these compounds can provide early warning detection of fire events while also indicating what materials have been exposed to heating. Continued post-fire monitoring of these hazardous gases can also facilitate safe and effective cleanup. The sensor is a miniaturized version of a five-channel prototype that was previously validated in ground-based oxidative pyrolysis tests. Here, we describe absorption line selection and theoretical detection limits for a sensor with reduced absorption pathlengths for each detection channel, which allows for a substantial reduction in overall instrument footprint. Ultimately, the new instrument is designed to be used in fire safety tests conducted by NASA, where various materials will undergo oxidative pyrolysis in an unmanned spacecraft returning from low Earth orbit.

Briggs, Ryan M.↗

Using SCIAMACHY and Ground-based FTS Measurements to Test the OCO X(sub CO2) Retrieval and Validation Approach

Global, space-based observations of atmospheric CO2 with precision, resolution, and coverage needed to monitor sources and sinks: a) Spectra of reflected/scattered sunlight in NIR CO2 and O2 bands used to estimate X(sub CO2) with large sensitivity to surface; b) A-train orbit (1:15 PM polar sun sync); c) 16 day repeat cycle samples seasonal cycle on semi-monthly intervals; and d) NASA ESSP (Earth Space System Pathfinder) scheduled for Sept 2008 launch; 2 yrs lifetime. Initial comparison of SCIAMACHY and FTS retrievals for Park Falls: a) Positive bias in X(sub CO2) of approx. 10 ppm; and b) Negative bias in surface pressure After correction of spectral artifacts in O2A band: a) Largely improved agreement between SCIAMACHY and FTS X(sub CO2) (without clear bias) and in surface pressure; and b) Standard deviation of SCIAMACHY X(sub CO2 approx. 6 ppm. Good qualitative agreement with GEOS-CHEM, with GEOS-CHEM underestimating seasonal cycle. OCO is a dedicated CO2 instrument and will achieve much higher accuracy and precision: a) much higher spectral resolution (by factor of 20); and b) smaller ground pixels (by factor of 600).

CO2 measurements↗

A contaminant monitor for submarine atmospheres.

A requirement for monitoring selected atmospheric constituents on board nuclear powered submarines has been met by the development of the Central Atmosphere Monitoring System, Mark I. This system employs a mass spectrometer to monitor H2, H2O, N2, O2, CO2, Freon 11, Freon 12, and Freon 114, in addition to an infrared sensor for CO. The CAMS MKI development is discussed, including background, operating fundamentals, principal requirements, functional and physical descriptions, and summarized test results. Each of two prototype units has successfully completed over 9000 hr of operational sea trails, providing the necessary ground work for the manufacture of production units. At the same time, these units, which have benefited extensively from NASA hardware experience, may in turn provide useful data for the development of a new class of maintainable atmospheric monitoring instrumentation for manned spacecraft.

Ruecker, M. R.↗

The Combustion Product Monitor instrument for the spacecraft fire safety demonstration project

The Combustion Product Monitor (CPM) instrument is a six-channel tunable laser absorption spectrometer capable of measuring ambient gas-phase concentrations of CO, HCl, HCN, HF, CO2, and O2 in spacecraft environments. Monitoring of these compounds can provide early warning detection of combustion events and can also facilitate safe post-fire cleanup. Here, we will describe the development of a CPM instrument optimized for operation as part of the Spacecraft Fire Safety Demonstration (Saffire) Project. As part of Saffire, the CPM instrument will measure concentrations of the target gases during low-gravity, reduced pressure oxidative pyrolysis of relevant test materials aboard a transfer vehicle returning from low Earth orbit. We will describe the CPM instrument design, absorption line selection,theoretical and experimental detection limits, and environmental testing.

Briggs, Ryan M.↗

Covid-19 Impact Monitoring for Climate Environment (Greenhouse Gases)

To track atmospheric CO2 changes resulting from the lockdowns, observations collected by the NASA Orbiting Carbon Observatory-2 (OCO-2) satellite and Japan’s Greenhouse gases Observing SATellite (GOSAT) in 2020 were compared to results collected in previous years. The OCO-2 results were used to search for changes on regional scales over the globe. Targeted observations from GOSAT were used to track changes in large urban areas, such as Beijing and Tokyo. Both types of observations yielded key insights into the CO2 changes accompanying the economic disruptions caused by the COVID-19 lockdowns. ESA, NASA and JAXA developed the dashboard jointly to monitor the climate impacts of COVID-19.

greenhouse gases↗

Combustion Products Monitor: Trade Study Testing

Current combustion products monitoring on the International Space Station (ISS) uses a handheld device (Compound Specific Analyzer-Combustion Products, CSA-CP) containing electrochemical sensors used to measure the concentration of carbon monoxide (CO), hydrogen chloride (HCl), hydrogen cyanide (HCN), and oxygen (O2). The CO sensor in this device accounts for a well-known cross-sensitivity with hydrogen (H2), which is important, as ISS air can contain up to 100 ppm H2. Unfortunately, this current device is being discontinued, and due to space constraints, the new model cannot accommodate the size of the current CO sensor. Therefore, a trade study was conducted in order to determine which CO sensors on the market were available with compensation for H2, and which instruments used these sensors, while also measuring HCN, O2, and carbon dioxide (CO2). The addition of CO2 to the device is helpful, as current monitoring of this gas requires a second hand-held monitor. By providing a device that will monitor both combustion products and CO2, volume and up-mass can be reduced as these monitors are delivered to ISS.

Wallace, William T.↗

Energy and remote sensing

Exploration for uranium, thorium, oil, gas and geothermal activity through remote sensing techniques is considered; satellite monitoring of coal-derived CO2 in the atmosphere, and the remote assessment of strip mining and land restoration are also mentioned. Reference is made to color ratio composites based on Landsat data, which may aid in the detection of uranium deposits, and to computer-enhanced black and white airborne scanning imagery, which may locate geothermal anomalies. Other applications of remote sensing to energy resources management, including mapping of transportation networks and power plant siting, are discussed.

Summers, R. A.↗

Short Exploration Extravehicular Mobility Unit Testing Setup: Evaluation Under Realistic Pressure and Thermal Conditions

The purpose of Short Exploration Extravehicular Mobility Unit (SxEMU) thermal vacuum testing was to verify the functionality of the Design Verification Testing (DVT) prototype xEMU (SxEMU for this test) at vacuum pressures and extreme space and lunar surface temperature conditions. The SxEMU Thermal Vacuum Test was the culmination of the DVT xEMU project. This paper’s focus is on the pre-Extravehicular Activity (EVA) test setup, and general performance of the SxEMU Portable Life Support Subsystem (xPLSS), with focus on the performance of the Primary Oxygen Assembly (POA) and Secondary Oxygen Assembly (SOA), including Secondary Oxygen Regulator (SOR) takeover and the POA and SOA low-setpoint change inhibit. The initial pre-EVA test preparation included recharging the batteries and replenishing consumables, including test-system water, oxygen assemblies (with gaseous nitrogen), and the integrated thermal loops, including the Feedwater Supply Assemblies. xPLSS functionality testing included carbon dioxide (CO2) removal via the Rapid Cycle Amine swingbed system, thermal loop temperature control, and monitoring of suit ventilation loop pressure, temperature, and CO2 percentages. Testing evaluated automatic takeover of suit pressure control by the SOR after the primary oxygen supply is depleted. The Primary Oxygen Regulator and SOR low-setpoint change inhibit function prevents the crewmember from inadvertently setting the primary regulator to a low pressure setpoint during an EVA.

xPLSS↗

Miniaturized Laser Absorption Spectrometer for Combustion Calorimetry and Process Monitoring

A miniaturized tunable laser absorption spectrometer capable of measuring gas-phase concentrations of CO, CO2, and O2 has been developed for operation in spacecraft environments. As part of the Spacecraft Fire Safety Demonstration (Saffire) project, we previously demonstrated the Combustion Product Monitor (CPM) instrument to characterize pyrolysis of relevant test materials in low gravity aboard a transfer vehicle returning from low Earth orbit. Here, we adapted the CPM instrument design to achieve detection of CO, CO2, and O2 with improved minimum detection limits and dynamic range as well as reduced instrument size and power. The instrument can be operated in either an open or sealed configureation, allowing for ambient gas composition measuremnts or in-line monitoring of gas streams. By accurately monitoring CO, CO2, and O2 with broad pressure/temperature calibration and response time on the order of 1 s, the instrument can be used to characterize the dynamics of combustion reactions in a variety of environments.

Briggs, Ryan M.↗

CO2 Sensors Based on Nanocrystalline SnO2 Doped with CuO

Nanocrystalline tin oxide (SnO2) doped with copper oxide (CuO) has been found to be useful as an electrical-resistance sensory material for measuring the concentration of carbon dioxide in air. SnO2 is an n-type semiconductor that has been widely used as a sensing material for detecting such reducing gases as carbon monoxide, some of the nitrogen oxides, and hydrocarbons. Without doping, SnO2 usually does not respond to carbon dioxide and other stable gases. The discovery that the electrical resistance of CuO-doped SnO2 varies significantly with the concentration of CO2 creates opportunities for the development of relatively inexpensive CO2 sensors for detecting fires and monitoring atmospheric conditions. This discovery could also lead to research that could alter fundamental knowledge of SnO2 as a sensing material, perhaps leading to the development of SnO2-based sensing materials for measuring concentrations of oxidizing gases. Prototype CO2 sensors based on CuO-doped SnO2 have been fabricated by means of semiconductor-microfabrication and sol-gel nanomaterial-synthesis batch processes that are amendable to inexpensive implementation in mass production.

Xu, Jennifer C.↗

A study to identify and compare airborne systems for in-situ measurements of launch vehicle effluents

An in-situ system for monitoring the concentration of HCl, CO, CO2, and Al2O3 in the cloud of reaction products that form as a result of a launch of solid propellant launch vehicle is studied. A wide array of instrumentation and platforms are reviewed to yield the recommended system. An airborne system suited to monitoring pollution concentrations over urban areas for the purpose of calibrating remote sensors is then selected using a similar methodology to yield the optimal configuration.

Thomas, T. J.↗

A prototype gas exchange monitor for exercise stress testing aboard NASA Space Station

This paper describes an easy-to-use monitor developed to track the weightlessness deconditioning aboard the NASA Space Station, together with the results of testing of a prototype instrument. The monitor measures the O2 uptake and CO2 production, and calculates the maximum O2 uptake and anaerobic threshold during an exercise stress test. The system uses two flowmeters in series to achieve a completely automatic calibration, and uses breath-by-breath compensation for sample line-transport delay. The monitor was evaluated using two laboratory methods and was shown to be accurate. The system's block diagram and the bench test setup diagram are included.

Orr, Joseph A.↗

Novel Carbon Dioxide Microsensor Based on Tin Oxide Nanomaterial Doped With Copper Oxide

Carbon dioxide (CO2) is one of the major indicators of fire and therefore its measurement is very important for low-false-alarm fire detection and emissions monitoring. However, only a limited number of CO2 sensing materials exist due to the high chemical stability of CO2. In this work, a novel CO2 microsensor based on nanocrystalline tin oxide (SnO2) doped with copper oxide (CuO) has been successfully demonstrated. The CuO-SnO2 based CO2 microsensors are fabricated by means of microelectromechanical systems (MEMS) technology and sol-gel nanomaterial-synthesis processes. At a doping level of CuO: SnO2 = 1:8 (molar ratio), the resistance of the sensor has a linear response to CO2 concentrations for the range of 1 to 4 percent CO2 in air at 450 C. This approach has demonstrated the use of SnO2, typically used for the detection of reducing gases, in the detection of an oxidizing gas.

Xu, Jennifer C.↗