Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CO2 absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was approximately 80, 65, 50 and 35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of approximately 95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was approximately 105, 90, 85, 80, and 70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion, using Fe as corrosion proxy, under harsh corrosive environment.

Mainali, Badri↗

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was ~80, ~65, ~50 and ~35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of ~95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was ~105, ~90, ~85, ~ 80, and ~70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion occurs.

Mainali, Badri↗

Cooperative Effects Associated with High Electrolyte Concentrations in Driving the Conversion of CO2 to C2H4 on Copper

Compared to a conventional electrolyte concentration of 1 M HCOOK, the use of a highly concentrated 7.1 M HCOOK electrolyte increases the Faradaic efficiency (FE) ratio of C2H4/CO from 2.2 +- 0.3 to 18.3 +- 4.8 at -1.08 V vs. reversible hydrogen electrode (RHE) on a Cu gas-diffusion electrode. Based on electrochemical analysis and ab initio molecular dynamics (AIMD) simulation, the identity and concentration of the cation and anion play more important roles in controlling the CO2R reaction pathway than the bulk CO2 solubility and the bulk pH of electrolytes. In situ attenuated reflectance surface enhanced infrared absorption spectroscopy (ATR-SEIRAS) suggests that, unlike 1 M HCOOK, the *CO-bridge-binding mode on Cu is dominant in 7.1 M HCOOK electrolyte, which potentially results in less CO release and higher yield of C2H4. This study demonstrates that although we can tailor the electrolyte composition to shift product selectivity, the factors that control the product selectivity are numerous and cannot be distilled down into one correlated property-reactivity relationship.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AmeriFlux US-GL1 Stannard Rock

This is the AmeriFlux version of the carbon flux data for the site US-GL1 Stannard Rock. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris↗

AmeriFlux FLUXNET-1F US-GL1 Stannard Rock

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-GL1 Stannard Rock. This is the FLUXNET version of the carbon flux data for the site US-GL1 Stannard Rock produced by applying the standard ONEFlux (1F) software. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris [Environment and Climate Change Cana↗

Defective Sn-Zn perovskites through bio-directed routes for modulating CO 2 RR

Sn and Zn oxides can catalyze electrochemical CO 2 reduction reactions (CO 2 RR) to produce useful chemicals. Herein, we report on perovskite-type tin-zinc oxides (TZO) synthesized by a biomineralization approach under benign aqueous conditions. The resulting TZO catalysts are disordered and possess a high quantity of defects, which serve as highly reactive active sites in CO 2 RR. Selectively toward formate or CO is tunable toward the relative amounts of Sn and Zn and their associated O defects. In-situ X-ray absorption spectroscopy measurements reveal electronic and structural transformations consistent with oxygen vacancy formation at Sn-O-Zn bridges as a function of cathodic potential that strongly correlates to CO2RR selectivity. Further, Density functional theory (DFT) calculations demonstrate that introducing an oxygen vacancy in TZO influences drastically influences formate/CO selectivity, consistent with our in-situ XAS findings and catalytic performance. Overall, these findings demonstrate the potential of biomineralization to fabricate perovskite-type metal oxides for energy conversion reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO Laser Absorption Measurements During Syngas Combustion at High Pressure

Abstract Syngas is a desirable fuel for combustion in the Allam-Fetvedt cycle, which involves combustion under supercritical-CO2 conditions. While some work has been conducted in collecting ignition delay times (IDT) at the extreme pressures required by these systems, significant model deficiencies remain. Additionally, considerable barriers in terms of nonideal gas dynamic effects have been shown for these experiments in shock tubes. Further investigation into the fundamental combustion kinetics of H2/CO/CO2 mixtures is required. Time-resolved speciation measurements for target species have been shown to better aid in improving the understanding of underlying chemical kinetics than global ignition delay time measurements. Therefore, laser absorption measurements of CO were measured behind reflected shock waves during combustion of syngas at 5 and 10 bar and temperatures between 1080 and 2100 K. The mixtures investigated utilized H2-to-CO ratios of 1:1 and 1:4, respectively, each at stoichiometric conditions, allowing for discussions of the effect of initial fuel composition. A ratio of fuel to CO2 of 1:2 was also utilized to represent commercially available syngas. The mixtures were diluted in helium and argon (20% He, 76.5% Ar) to minimize thermal effects and to expedite CO thermal relaxation during the experiment. The resulting CO time histories were then compared to modern chemical kinetics mechanisms, and disagreement is seen for this system, which is assumed to be fairly well known. This study elucidates particular chemistry that needs improvement in moving toward a better understanding of syngas combustion at elevated pressures.

Engineering↗

Process intensification of CO 2 capture by low-aqueous solvent

Low-energy solvent-based CO 2 absorption processes have drawn attention as a next-generation post-combustion CO 2 capture technology to reduce CO2 emissions from fossil fuel– or biomass-fired power generation and industrial flue gas streams. A low-aqueous (or water-lean) solvent process may substantially reduce the thermal energy consumption for solvent regeneration. Low-aqueous solvent–based processes are thermally sensitive, requiring a delicate temperature control within the absorber because of the fast exothermic amine-CO 2 reaction and low heat capacity organic diluent. This reaction may result in heat accumulation in a packed absorption column and undesirable CO 2 desorption occurring as the solvent moves through the column, reducing the solvent’s CO 2 capture efficiency if its temperature is not controlled. Using a 3D printed intensified packing device, enhanced heat and mass transfer were demonstrated in an amine-CO 2 scrubbing process using low-aqueous solvent. The multifunctional intensified device facilitates contact of the reactive solvent and gas phases in a single stage and heat removal by a cooling fluid flowing through channels in the interior of the corrugated plates of the device. These functionalities led to effective thermal management along the column via intrastage cooling and significant improvement in CO 2 uptake under a wide range of operating conditions. Intrastage cooling effectively reduced the solvent average temperature along the column by ~10 °C and, as a result, the solvent’s capture efficiency improved by up to 25%.

42 ENGINEERING↗

Durable and Versatile Immobilized Carbonic Anhydrase on Textile Structured Packing for CO 2 Capture

High-performance carbon dioxide (CO 2 )-capture technologies with low environmental impact are necessary to combat the current climate change crisis. Durable and versatile “drop-in-ready” textile structured packings with covalently immobilized carbonic anhydrase (CA) were created as efficient, easy to handle catalysts for CO 2 absorption in benign solvents. The hydrophilic textile structure itself contributed high surface area and superior liquid transport properties to promote gas-liquid reactions that were further enhanced by the presence of CA, leading to excellent CO 2 absorption efficiencies in lab-scale tests. Mechanistic investigations revealed that CO 2 capture efficiency depended primarily on immobilized enzymes at or near the surface, whereas polymer entrapped enzymes were more protected from external stressors than those exposed at the surface, providing strategies to optimize performance and durability. Textile packing with covalently attached enzyme aggregates retained 100% of the initial 66.7% CO 2 capture efficiency over 71-day longevity testing and retained 85% of the initial capture efficiency after 1-year of ambient dry storage. Subsequent stable performance in a 500 h continuous liquid flow scrubber test emphasized the material robustness. Biocatalytic textile packings performed well with different desirable solvents and across wide CO 2 concentration ranges that are critical for CO 2 capture from coal and natural gas-fired power plants, from natural gas and biogas for fuel upgrading, and directly from air.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Application of a Heat Integrated Post-combustion CO 2 Capture System with Hitachi Advanced Solvent into Existing Coal-Fired Power Plant (Final Technical Report)

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0007395. In accordance with the Project Management Plan (PMP), Revision F dated 5/10/2019, and Statement of Project Objectives (SOPO) within, the University of Kentucky (UK) Center for Applied Energy Research (CAER) (Recipient) has successfully demonstrated a unique, versatile CO 2 capture system (CCS) using a heat integrated process combined with two-stage stripping for process intensification, heat recovery and demineralized (DM) water generation. This project involved the design, fabrication, installation, testing of and data analysis from the UK CAER 0.7 MWe small pilot scale CO2 capture process installed at Kentucky Utilities (KU) E.W. Brown Generating Station in Harrodsburg, KY. During each of the four project Budget Periods (BPs), UK CAER met all project deliverables, all project milestones, with National Energy Technology Laboratory (NETL) approved adjustments made to the campaign long-term hours during BP4. The CCS was constructed in modular skids. Two solvent campaigns were initially conducted; the first with a 30 wt% monoethanolamine (MEA) as a baseline, and the second with the Hitachi H3-1 advanced solvent. Additional tests were performed with two advanced solvents including CAER and Proprietary Solvent C. Short-period testing with a higher concentration of 40 wt% MEA was conducted to evaluate the potential saving with high alkalinity. From the various solvent campaigns, unique aspects of the UK CAER CCS technology, as well as its flexibility and versatility were experimentally validated and demonstrated. With respect to solvent evaluation efforts in identifying candidates with significant operational and capital cost savings potential, performance of solvents were evaluated to determine the energy requirements for regeneration; environmental impacts from secondary emissions and degradation products; degradation rates, solvent make-up rates and stability. The assessments were done from parametric tests that determined optimum operating conditions for the individual solvents to maximize process efficiency and minimize the parasitic load of the power plant, and from long term campaigns (1000 hours for 30 wt% MEA and 1000 hours for H3-1) which collectively informed the techno-economic analyses (TEA) of the process. The long term campaigns included corrosion studies which used three types of metal coupons in different sections of the process: (absorber, primary stripper, lean carbon-loaded and rich carbon loaded flow streams in process) to mimic heat and flow dynamics process equipment were exposed to. The estimated corrosion rates were used to elucidate corrosion mechanisms and to further guide process material selection for potential capital cost savings.

gas separation↗

Laser absorption measurements of temperature, pressure, CO, and CO 2 at near-MHz rates in post-detonation fireballs with comparison to synthetic measurements

A laser absorption spectroscopy (LAS) diagnostic was used to obtain measurements of temperature, pressure, CO, and CO 2 at 500 kHz or 1 MHz in post-detonation fireballs produced by hemispherical samples of pentaerythritol tetranitrate (PETN). A quantum-cascade laser was scanned over multiple CO absorption transitions near 2008.5 cm −1 at 1 MHz, while an interband-cascade laser was scanned over a CO 2 absorption transition near 2394.8 cm −1 at 500 kHz. Light from each laser was combined onto a single path and passed through a detonation chamber approximately 83 mm above the 12-mm diameter hemispherical PETN charge. The CO and CO 2 absorption signals were post-processed to obtain time histories of temperature, pressure, species column pressures (P CO L, P CO2 L), and species column mole fractions (X CO L, X CO2 L). Additionally, schlieren imaging was performed simultaneously at 500 kHz to aid interpretation of the LAS measurements. Experimental and synthetic (i.e., CFD based) LAS measurements were compared to evaluate the accuracy of the CFD model and its ability to model the turbulent afterburning of the detonation products in air. In general, the experimental measurements exhibit reasonable agreement with the synthetic measurements at early times; thereby supporting the accuracy of the CFD model. Periods of disagreement between experimental and synthetic measurements at later times are most likely due to a reflected shock and detonator cavity jetting, which are not accounted for in the CFD model.

Schwartz, Charles J. [Purdue Univ., West Lafayette↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO 2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-Fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO 2 ) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO 2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Data for Increased bundle sheath leakiness of CO2 during photosynthetic induction shows a lack of coordination between the C4 and C3 cycles

We developed a new application of isotopic gas exchange which couples a tunable diode laser absorption spectroscope (TDL) with a leaf gas exchange system, analyzing leakiness through induction of C4 photosynthesis on dark to high-light transitions. The youngest fully expanded leaf was measured on 40-45 day-old maize(B73) and sorghum (Tx430). Detail definition of each variable in raw Li-6400XT and Li-6800 (in "Original_data_AND_Data_processing_code.zip") is summarized in: https://www.licor.com/env/support/LI-6800/topics/symbols.html#const

bundle sheath leakage↗

X-ray Absorption Spectroscopy Studies of a Molecular CO 2 -Reduction Catalyst Deposited on Graphitic Carbon Nitride

Metal-ligand complexes have been extensively explored as well-defined molecular catalysts in small molecule activation reactions such as carbon dioxide (CO 2 ) reduction. Many hybrid photocatalysts have been prepared by coupling such complexes with photoactive surfaces for use in solar CO 2 reduction. In this work, we employ X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) spectroscopies, density functional theory (DFT) and computational XANES modeling to interrogate the structure of a hybrid photocatalyst consisting of a macrocyclic cobalt complex deposited on graphitic carbon nitride (C 3 N 4 ). Results show that the cobalt complex binds on C 3 N 4 through surface OH or NH 2 groups. By refining the local geometry and binding sites of this well-defined molecular cobalt complex on C 3 N 4 , here we established an important benchmark for modeling a large class of molecular catalysts that can be adapted to in situ/operando studies and further enhanced by applying chemometrics-based approaches and machine learning methods of XANES data analysis.

36 MATERIALS SCIENCE↗

Utilization of waste heat from a commercial GT for freshwater production, cooling and additional power: Exergoeconomic analysis and optimization

In this work, a multigeneration system is proposed for power, cooling and freshwater production. The waste heat from a SIEMENS SGT6-2000E GT is utilized to drive a supercritical CO 2 recompression Brayton cycle (SCRBC) and multi-effect desalination (MED) with thermal vapor compressor (TVC), while the waste heat from the pre-cooler of the SCRBC is utilized to drive an absorption cooling cycle. Detailed thermodynamic, exergy and exergoeconomic analyses are performed for the proposed multigeneration system using Engineering Equation Solver (EES). A sensitivity study is also performed to study the effects of the main operational parameters on the proposed system performance. Finally, multi-objective optimization using a genetic algorithm approach in EES is carried out to reach the optimal design. The proposed system can consume 34.2% less energy input and reduce CO 2 emission by 39.3% compared to the stand-alone systems for power, cooling and freshwater production. The results show that the energy utilization factor and exergy efficiency of the proposed system are improved by 33.6% and 14.3%, respectively, while the total unit product cost is reduced by 11.3% compared to the stand-alone GT cycle. Further, from exergoeconomic optimization, the proposed system can produce 132.4 MW of power, 7.09 MW of cooling and 650 kg/s of freshwater at energy utilization factor of 57.5%, exergy efficiency of 39.7% and total unit product cost of 16.3 $/GJ.

42 ENGINEERING↗