Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CESIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Influence of the Dirac-Hartree-Fock starting potential on the parity-nonconserving electric-dipole-transition amplitudes in cesium and thallium

The parity-nonconserving electric-dipole-transition amplitudes for the 6s1/2-7s1/2 transition in cesium and the 6p1/2-7p1/2 transition in thallium have been calculated by the Dirac-Hartree-Fock method. The effects of using different Dirac-Hartree-Fock atomic core potentials are examined and the transition amplitudes for both the length and velocity gauges are given. It is found that the parity-nonconserving transition amplitudes exhibit a greater dependence on the starting potential for thallium than for cesium.

Perger, W. F.

Theoretical studies of Resonance Enhanced Stimulated Raman Scattering (RESRS) of frequency-doubled Alexandrite laser wavelength in cesium vapor

The solutions for the imaginary susceptibility of the Raman field transition with arbitrary relaxation rates and field strengths are examined for three different sets of relaxation rates. These rates correspond to: (1) Far Infrared (FIR) Raman lasers in the diabatic collision regime without consideration of coupled population decay in a closed system, (2) Raman FIR lasers in the diabatic collision regime with coupled population conserving decay, and (3) IR Raman gain in cesium vapor. The model is further expanded to include Doppler broadening and used to predict the peak gain as a function of detuning for a frequency doubled Alexandrite laser-pumped cesium vapor gain cell.

Lawandy, Nabil M.

The status of cesium beam frequency standards

There has been a lot of progress in cesium beam frequency standards in the last few years some of which will be reported here. Optical pumping is being pursued actively in a number of laboratories. Optically slowed and cooled beams have been demonstrated as well as traps for cold neutral atoms. The microwave cavity performance with regard to local phase shift at the beam holes was improved by use of carefully designed and built ring structures for the cavity ends. Work is being done on improvements in electronics with some emphasis on use of digital circuitry and microprocessors. The frequency pulling due to microwave Delta M = +/- 1 transitions (Ramsey pulling) was analyzed and shown to be important. Status of cesium beam frequency standards in some of the laboratories as well as some of the commercial work is discussed. Optical pumping and detection are discussed.

Cutler, Leonard S.

Physical origin of the frequency shifts in cesium beam frequency standards: Related environmental sensitivity

When observed in a cesium beam frequency standard, the hyperfine transition frequency of the atoms differs slightly from the invariant transition frequency of the unperturbed atoms at rest. The various physical and technical origins of the frequency offsets are stated. They relate to fundamental physical effects, to the method of probing the atomic resonance and to the frequency control of the slaved oscillator. The variation of the frequency offsets under a change of the value of the internal operating characteristics is considered. The sensitivity to a change of the magnetic induction, the microwave power, and the temperature is given. A comparison is made of the sensitivity of cesium beam frequency standards of the commercially available type, making use of magnetic state selection, and of devices under study, in which the state preparation and detection is accomplished optically. The pathways between the external stimuli and the physical origin of the frequency offsets are specified.

Audoin, Claude

Timescale algorithms combining cesium clocks and hydrogen masers

The United States Naval Observatory (USNO) atomic timescale, formerly based on an ensemble of cesium clocks, is now produced by an ensemble of cesium clocks and hydrogen masers. In order to optimize stability and reliability, equal clock weighting has been replaced by a procedure reflecting the relative, time-varying noise characteristics of the two different types of clocks. Correlation of frequency drift is required, and residual drift is avoided by the eventual complete deweighting of the masers.

Lee A. Breakiron

CAFS: A Cesium Atomic Frequency Standard for GPS block IIR

Kernco, Inc. was selected to design the Cesium Atomic Frequency Standards (CAFS) for the GPS Block IIR NAVSTAR satellites. These spacecraft are scheduled to be launched in the mid-1990's to replenish and upgrade the existing constellation of Global Positioning System satellites. The Block IIR CAFS output frequency is 13.4003378 MHz, the 686th submultiple of the cesium atomic resonance frequency. Using an integer submultiple simplifies the design of the atomic frequency standard's rf multiplier circuits, eliminating the secondary frequency synthesizer needed in previous designs. The GPS Block IIR CAFS design, particularly the improvements made on our earlier Block II design is described. Test results are included.

Wisnia, Jeffry A.

Low-Light-Shift Cesium Fountain without Mechanical Shutters

A new technique for reducing errors in a laser-cooled cesium fountain frequency standard provides for strong suppression of the light shift without need for mechanical shutters. Because mechanical shutters are typically susceptible to failure after operating times of the order of months, the elimination of mechanical shutters could contribute significantly to the reliability of frequency standards that are required to function continuously for longer time intervals. With respect to the operation of an atomic-fountain frequency standard, the term "light shift" denotes an undesired relative shift in the two energy levels of the atoms (in this case, cesium atoms) in the atomic fountain during interrogation by microwaves. The shift in energy levels translates to a frequency shift that reduces the precision and possibly accuracy of the frequency standard. For reasons too complex to describe within the space available for this article, the light shift is caused by any laser light that reaches the atoms during the microwave- interrogation period, but is strongest for near-resonance light. In the absence of any mitigating design feature, the light shift, expressed as a fraction of the standard fs frequency, could be as large as approx. 2 x 10(exp -11), the largest error in the standard. In a typical prior design, to suppress light shift, the intensity of laser light is reduced during the interrogation period by using a single-pass acoustooptic modulator to deflect the majority of light away from the main optical path. Mechanical shutters are used to block the remaining undeflected light to ensure complete attenuation. Without shutters, this remaining undeflected light could cause a light shift of as much as .10.15, which is unacceptably large in some applications. The new technique implemented here involves additionally shifting the laser wavelength off resonance by a relatively large amount (typically of the order of nanometers) during microwave interrogation. In this design, when microwave interrogation is not underway, the atoms are illuminated by a slave laser locked to the lasing frequency of a lower power master laser.

Enzer, Daphna

Investigating the Role π -Rich Solvents Play in the Growth of Cesium Lead Bromide Nanocrystals

In this report, the role that a high-boiling-point solvent type plays on the nucleation and growth, morphology, and crystal-phase transformation of cesium lead bromide nanocrystals (CsPbBr 3 ) is studied. The CsPbBr 3 products were compared between a one-pot growth mechanism at room temperature (RT) versus a hot-injection mechanism (HI) control using dibenzyl ether (DBE), diphenyl ether (DPE), dioctyl ether (DOE), or 1- octadecene (ODE). The coordination between these solvents and the PbBr 2 salt precursors resulted in different plumbate [PbSBr n ] 2−n precursors being formed. The S-to-Pb 2+ coordination within [PbSBr n ] 2−n was probed by UV−vis and solvent-phase 207 Pb NMR, both of which showed considerable coordination between [PbSBr n ] 2−n and the π-rich DBE and DPE, whose reactivity affected CsPbBr 3 growth. The effect was more pronounced for CsPbBr 3 prepared via RT, where the morphology was tunable, with π-rich solvents producing thin rod-like CsPbB r3 with a blue emission, compared to the green-emitting thicker platelets formed via HI. While XRD showed crystalline products for both RT and HI, with orthorhombic and cubic forms, respectively, the RT products had considerable surface defects, as was indicated by lower quantum yields, and to understand this the photoluminescent lifetimes were measured by time-correlated single photon counting.

207Pb NMR

Multiscale, mechanistic modeling of cesium transport in silicon carbide for TRISO fuel performance prediction

Understanding cesium (Cs) transport in TRistructural ISOtropic (TRISO) particle fuel is crucial for predicting fission product release in high-temperature reactors. However, current challenges include significant scatter in diffusivity data and unexplained temperature-dependent diffusion regimes in the silicon carbide layer. This study addresses these challenges by developing a multiscale, mechanistic Cs transport model integrating atomistic simulations and phase field modeling. Our model quantifies temperature and grain size effects on Cs diffusivity, attributing experimentally observed regimes to a transition from bulk-dominated diffusivity at high temperatures to grain boundary-dominated diffusivity at lower temperatures. The model, validated against diffusion measurements and advanced gas reactor (AGR)-1 and AGR-2 post-irradiation fission product release data, enhances the predictive capability of the BISON fuel performance code. This study advances our understanding of Cs release from TRISO particles and its dependence on temperature and silicon carbide grain size, with implications for the safety and efficiency of high-temperature nuclear reactors.

BISON