Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CERENKOV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cosmic ray isotope resolution obtained using a new Cerenkov-total energy telescope

The details of a recent measurement of the cosmic ray isotopic composition of Z equals or exceeds 10 nuclei are given, using a new technique combining a Cerenkov and total energy counter. In terms of sigma, the characteristic width of a Gaussian distribution of mass measurement, values of mass resolution have been obtained ranging from about 0.4 AMU at a Z about 14, to about 0.8 AMU at a Z about 26, using the Cerenkov-total energy (C x E) technique. It is customary to claim that two equal Gaussian distributions may be resolved for values of sigma less than 0.4 x the separation of their means. With these criteria isotopes separated by delta A = 2 are being resolved up to a Z about 26 using the C x E technique. An important source of error in these measurements is the determination of the mass of each of the isotopes on an absolute scale.

Webber, W. R.↗

Certain problems in the development and design of scintillation and Cerenkov counters

The feasibility is examined of increasing the effectiveness of the scintillation and Cerenkov counters through improving light collection of the recorded radiation on the photoelectric cathode of the photomultiplier. An example of how to select a detector of the directional plexiglas Cerenkov counter is given. Also presented are experimentally obtained amplitude distributions during the recording of cosmic ray muons. The necessity to obtain agreement between the characteristic spectrum of the photocathode of the photomultiplier and the spectrum of the recorded radiation is stressed.

Chukin, V. S.↗

Gas threshold Cerenkov counters

The report describes two designs are reported of gas threshold Cerenkov counters for recording electrons of primary cosmic rays without recording protons. Also presented are design and technological measures which ensure maximum light collection of the Cerenkov radiation originating on the photocathode of the photomultiplier inside the radiator. The dependence of the reflection factor on the length of the light wave for different coatings is shown as well as for the throughput of the different optical materials employed. A range of methods for determining the efficiency of the counters during the recording of cosmic ray nucons and ways of increasing it further are given.

Logachev, V. I.↗

The effect of delta ray production on Cerenkov counter response

Light generated by delta rays in Cerenkov counters contributes to the mean counter signal in addition to producing fluctuations in this signal. The dependence of this contribution on the energy of the primary particle deviates significantly from the Cerenkov formula. When using such a counter to measure the index of a typical cosmic ray power law spectrum, neglect of this effect can yield a value for the spectral index which is too high by 0.3. This paper presents calculations of this delta ray contribution as a function of the energy of the primary particle. It points out the need for accurate and independent determination of such experimental parameters as counter resolution (intrinsic and statistical), linearity, and normalization.

Evenson, P.↗

A method for unique identification of relativistic /greater than 0.5/ magnetic monopoles with a fast film Cerenkov detector

A magnetic monopole traversing a dielectric medium at a velocity greater than the phase velocity of light in that medium, will give rise to Cerenkov radiation with the electric field tangent to the cone generated by the photon wave propagation vector, and the magnetic field normal to that surface. This is the opposite polarization to that encountered with an electric charge. It is proposed that either by inserting a linearly polarizing layer between the radiator and the photographic emulsion, or by selecting a linearly polarizing material as the radiator, one could directly observe the field polarization by examining the photographic image and thus uniquely identify a magnetic monopole. The ability of the detector is further enhanced by the index of refraction dependence of the Cerenkov output from a magnetic monopole.

Pinsky, L. S.↗

Evolution of the Cerenkov x total-energy telescope for isotopic analysis of cosmic rays

This paper discusses the evolution of the Cerenkov x total energy technique for isotopic analysis of cosmic rays as developed by the University of New Hampshire. This technique is generally restricted to particles with Z greater than 6, and the best mass resolution is achieved over a relatively narrow energy range just above the Cerenkov threshold. State-of-the-art mass resolution is now 0.3-0.4 AMU throughout the charge range z = 8-28 and over an energy range varying from about 40 MeV/n at lower Z to about 200 MeV/n for Fe.

Webber, W. R.↗

The hump in the Cerenkov lateral distribution of gamma ray showers

The lateral distribution of atmospheric Cerenkov photons emitted by gamma ray showers of energy 100 GeV is calculated. The lateral distribution shows a characteristic hump at a distance of approx. 135 meter from the core. The hump is shown to be due to electrons of threshold energy 1 GeV, above which the mean scattering angle becomes smaller than the Cerenkov angle.

Sinha, S.↗

Measurement of muon intensity by Cerenkov method

Optical detection is an important technique in studies and observations of air showers, muons and relevant phenomena. The muon intensity is measured in a proper energy range and to study some problems about Cerenkov radiation of cosmic rays are studied, by a muon-telescope operated with Cerenkov detector. It is found that the measured muon intensity agrees with the integral energy spectrum of cosmic ray muons.

Liu, Z. H.↗

Studies of air showers produced by primaries 10(16) eV using a combined scintillation and water-Cerenkov array

An array of 8 x 1.0 sq m plastic scintillation counters and 13 water-Cerenkov detectors (1 to 13.5 sq m) were operated at the center of the Haverah Park array to study some features of air showers produced by 10(16) eV primaries. Measurements of the scintillator lateral distribution function, the water-Cerenkov lateral distribution function, and of the distance dependence of the Cerenkov/scintillator ratio are described.

Brooke, G.↗

Cerenkov Radiator Driven by a Superconducting RF Electron Gun

The Naval Postgraduate School (NPS), Niowave, Inc., and Boeing have recently demonstrated operation of the first superconducting RF electron gun based on a quarter wave resonator structure. In preliminary tests, this gun has produced 10 ps long bunches with charge in excess of 78 pC, and with beam energy up to 396 keV. Initial testing occurred at Niowave's Lansing, MI facility, but the gun and diagnostic beam line are planned for installation in California in the near future. The design of the diagnostic beam line is conducive to the addition of a Cerenkov radiator without interfering with other beam line operations. Design and simulations of a Cerenkov radiator, consisting of a dielectric lined waveguide will be presented. The dispersion relation for the structure is determined and the beam interaction is studied using numerical simulations. The characteristics of the microwave radiation produced in both the short and long bunch regimes will be presented.

43 PARTICLE ACCELERATORS↗

Spent Fuel Verification Using a Digital Cerenkov Viewing Device

A portable digital Cerenkov viewing device (DCVD-e) was developed to verify light water reactor fuel cooled as long as 40 years with a burnup of 10,000 MWd/t U. This measurement regime is beyond the capability of the improved Cerenkov viewing Device (ICVD) used by the International Atomic Energy Agency inspectors for spent fuel verification. The DCVD-e has verified spent fuel with a very low burnup of 1,200 MWd/t U cooled for 36 years and we expect to verify this assembly cooled past 60 years. This exceeds the target requirement. The verification method requires no fuel movement and no water contact. It is possible for one inspector to perform a fuel pond verification. Future studies include instrument characterization to allow the detection of partial defects. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SNM Detection with a Large Water Cerenkov Detector

Special Nuclear Material (SNM) can either spontaneously fission, or be induced to do so. Either case results in neutron emission. Since neutrons are highly penetrating and difficult to shield, they could, potentially, be detected escaping even a well shielded cargo container. Obviously, if the shielding is sophisticated, detecting it would require a highly efficient detector with close to 4{pi} solid angle coverage. Water Cerenkov detectors may be a cost effective way to achieve that goal if it can be shown that the neutron capture signature is large enough and if sufficient background rejection can be employed as detectors get larger. In 2008 the LLNL Advanced Detector Group reported the successful detection of neutrons with a 1/4 ton gadolinium doped water Cerenkov prototype. We have now built a 4 ton version. This detector is not only bigger, it was designed with photon detection efficiency in mind from the beginning. We are employing increased photocathode coverage and more reflective walls, coated with PTFE. The increased efficiency should allow better energy resolution. We expect that the better diffusive wall reflectivity will reduce the overall dependence of the detector response on particle direction, again producing a more consistent response. We also believe that as detectors get larger, both uncorrelated and correlated backgrounds due to gamma-rays and cosmic ray interactions near the detector will increase. To prove the effectiveness of the technology we must develop new ways to reject these backgrounds while maintaining our sensitivity to SNM neutrons. Better energy resolution will enable us to reject more of the low energy gamma-ray backgrounds on this basis. Overcoming cosmic ray induced neutrons is perhaps an even larger concern as detectors get larger. Our detector is designed so that we can test various segmentation schemes - effectively dividing the detector up into smaller ones. In this presentation, we will describe our detector in detail.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Construction of A Cerenkov Counter for In Situ Monitoring of Sr-90 in Groundwater

Migration of groundwater contamination from beneath the U.S. Department of Energy’s Hanford Site into the Columbia River creates a need for in situ 90Sr monitoring. The prototype monitor discussed here is designed for deployment inside a monitoring well and provides near-real-time determination of the 90Sr concentration in a two-liter groundwater sample. The measurement is made by direct detection of Cerenkov light generated in the water by beta decay of the 90Y daughter. This manuscript presents results from a prototype monitor that was designed by a parametric Monte Carlo simulation study. Calibration and testing results of the as-built system show near perfect agreement between simulated predictions and experimental results. Downwell and laboratory tests demonstrate that the prototype monitor is sensitive to 90Sr at concentrations below drinking water standards of 8 pCi/l (0.3 Bq/l) at the 90% confidence level in measurement times of less than four hours.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Controlling the numerical Cerenkov instability in PIC simulations using a customized finite difference Maxwell solver and a local FFT based current correction

In this study we present a customized finite-difference-time-domain (FDTD) Maxwell solver for the particle-in-cell (PIC) algorithm. The solver is customized to effectively eliminate the numerical Cerenkov instability (NCI) which arises when a plasma (neutral or non-neutral) relativistically drifts on a grid when using the PIC algorithm. We control the EM dispersion curve in the direction of the plasma drift of a FDTD Maxwell solver by using a customized higher order finite difference operator for the spatial derivative along the direction of the drift (1ˆ direction). We show that this eliminates the main NCI modes with moderate |k 1 |, while keeps additional main NCI modes well outside the range of physical interest with higher |k 1 |. These main NCI modes can be easily filtered out along with first spatial aliasing NCI modes which are also at the edge of the fundamental Brillouin zone. The customized solver has the possible advantage of improved parallel scalability because it can be easily partitioned along 1ˆ which typically has many more cells than other directions for the problems of interest. We show that FFTs can be performed locally to current on each partition to filter out the main and first spatial aliasing NCI modes, and to correct the current so that it satisfies the continuity equation for the customized spatial derivative. This ensures that Gauss’ Law is satisfied. Lastly, we present simulation examples of one relativistically drifting plasma, of two colliding relativistically drifting plasmas, and of nonlinear laser wakefield acceleration (LWFA) in a Lorentz boosted frame that show no evidence of the NCI can be observed when using this customized Maxwell solver together with its NCI elimination scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cerenkov Light

The bright blue glow from nuclear reactors is Cerenkov light. Karl Slifer describes how nuclear physicists can use this phenomenon to study the nucleus of the atom.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗