Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CDMS II”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Search for Weakly Interacting Massive Particles with the First Five-Tower Data from the Cryogenic Dark Matter Search at the Soudan Underground Laboratory

We report results from the Cryogenic Dark Matter Search at the Soudan Underground Laboratory (CDMS II) featuring the full complement of 30 detectors. A blind analysis of data taken between October 2006 and July 2007 sets an upper limit on the weakly interacting massive particle (WIMP) nucleon spin-independent cross section of 6.6x10{sup -44} cm{sup 2} (4.6x10{sup -44} cm{sup 2} when combined with previous CDMS II data) at the 90% confidence level for a WIMP mass of 60 GeV/c{sup 2}. This achieves the best sensitivity for dark matter WIMPs with masses above 44 GeV/c{sup 2}, and significantly restricts the parameter space for some favored supersymmetric models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonuniversal gaugino masses, CDMS, and the LHC

We consider the possibility that the recently reported events at the CDMS-II direct dark matter detection experiment are the result of a coherent scattering of supersymmetric neutralinos. In such a scenario we argue that nonuniversal soft supersymmetry breaking gaugino masses are favored with a resulting lightest neutralino with significant Higgsino and wino components. We discuss the accompanying signals which must be seen at liquid-xenon direct detection experiments and indirect detection experiments if such a supersymmetric interpretation is to be maintained. We illustrate the possible consequences for early discovery channels at the LHC via a set of benchmark points designed to give rise to an observed event rate comparable to the reported CDMS-II data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of the low-energy electron-recoil spectrum of the CDMS experiment

We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the observed counting rate and possible background sources in the energy range of 2-8.5 keV. We find no significant excess of a peaked contribution to the total counting rate above the background model, and compare this observation to the recent DAMA results. In the framework of a conversion of a dark matter particle into electromagnetic energy, our 90% confidence level upper limit of 0.246 events/kg/day at 3.15 keV is lower than the total rate above background observed by DAMA. In absence of any specific particle physics model to provide the scaling in cross section between NaI and Ge, we assume a Z{sup 2} scaling. With this assumption the observed rate in DAMA remains higher than the upper limit in CDMS. Under the conservative assumption that the modulation amplitude is 6% of the total rate we obtain upper limits on the modulation amplitude a factor of {approx}2 lower than observed by DAMA, constraining some possible interpretations of this modulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A possible explanation of low energy γ-ray excess from galactic centre and Fermi bubble by a Dark Matter model with two real scalars

We promote the idea of multi-component Dark Matter (DM) to explain results from both direct and indirect detection experiments. In these models as contribution of each DM candidate to relic abundance is summed up to meet WMAP/Planck measurements of Ω{sub DM}, these candidates have larger annihilation cross-sections compared to the single-component DM models. We illustrate this fact by introducing an extra scalar to the popular single real scalar DM model. We also present detailed calculations for the vacuum stability bounds, perturbative unitarity and triviality constraints on this model. As direct detection experimental results still show some conflict, we kept our options open, discussing different scenarios with different DM mass zones. In the framework of our model we make an interesting observation: the existing direct detection experiments like CDMS II, CoGeNT, CRESST II, XENON 100 or LUX together with the observation of excess low energy γ-ray from galactic centre and Fermi bubble by Fermi Gamma-ray Space Telescope (FGST) already have the capability to distinguish between different DM halo profiles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessing compatibility of direct detection data: halo-independent global likelihood analyses

We present two different halo-independent methods to assess the compatibility of several direct dark matter detection data sets for a given dark matter model using a global likelihood consisting of at least one extended likelihood and an arbitrary number of Gaussian or Poisson likelihoods. In the first method we find the global best fit halo function (we prove that it is a unique piecewise constant function with a number of down steps smaller than or equal to a maximum number that we compute) and construct a two-sided pointwise confidence band at any desired confidence level, which can then be compared with those derived from the extended likelihood alone to assess the joint compatibility of the data. In the second method we define a “constrained parameter goodness-of-fit” test statistic, whose p-value we then use to define a “plausibility region” (e.g. where p≥10%). For any halo function not entirely contained within the plausibility region, the level of compatibility of the data is very low (e.g. p<10%). We illustrate these methods by applying them to CDMS-II-Si and SuperCDMS data, assuming dark matter particles with elastic spin-independent isospin-conserving interactions or exothermic spin-independent isospin-violating interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SuperCDMS Prototype Detector Design and Testing

A substantial amount of astrophysical evidence indicates that approximately a quarter of all energy in the universe is composed of a nonluminous, and nonbaryonic \dark" matter. Of the potential dark matter particle candidates, Weakly Interacting Massive Particles, or WIMPs, is particularly well motivated. As a means to directly detect WIMP interactions with baryonic matter, the Cryogenic Dark Matter Search (CDMS) project was established, operating at the Soudan Underground Laboratory from 2003 - 2015, under the CDMS II and SuperCDMS Soudan experiments. CDMS detectors simultaneously measure the ionization and phonon energies of recoil events in Si and Ge crystals kept at cryogenic temperatures in a low-background environment. The ratio of ionization energy to recoil energy serves as a discrimination parameter to separate nuclear recoil events from the electron-recoil background. The next installation, SuperCDMS SNOLAB, is preparing for future operation, with an initial payload of eighteen Ge and six Si, 100 mm diameter, 33 mm thick detectors. Of this initial payload, eight Ge and four Si detectors will operate in a high-voltage ( 100 V) mode, which have an increased sensitivity to low-mass WIMPs due to decreased energy thresholds. The SuperCDMS test facility at University of Minnesota aids in the detector R&D and characterization of prototype detectors, as part of the scale-up eort for Super- CDMS SNOLAB. This thesis presents the rst full ionization and phonon characterization study of a 100 mm diameter, 33 mm thick prototype Ge detector with interleaved phonon and ionization channels. Measurements include ionization collection eciency, surface event rejection capabilities, and successful demonstration of nuclear recoil event discrimination. Results indicate that 100 mm diameter, interleaved Ge detectors show potential for use in SuperCDMS SNOLAB. As part of detector R&D, the Minnesota test facility also looks beyond the next stage of SuperCDMS, investigating larger individual detectors as a means to easily scale up the sensitive mass of future searches. This thesis presents the design and initial testing results of a prototype 150 mm diameter, 33 mm thick silicon ionization detector, which is 5.2 times larger than those used in SuperCDMS at Soudan and 2.25 times larger than those planned for use at SuperCDMS SNOLAB. In addition, the detector was operated with contact-free ionization electrodes to minimize bias leakage currents, which can limit operation at high bias voltages. The results show promise for the operation of both large volume silicon detectors and contact-free ionization electrodes for scaling up detector mass and bias.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bound on Z

With the recent possible signal of dark matter from the CDMS II experiment, the Z{prime} mass of a new version of the dark left-right gauge model (DLRM II) is predicted to be at around a TeV. As such, it has an excellent discovery prognosis at the operating Large Hadron Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Cryogenic Dark Matter Search: First 5-Tower Data and Improved Understanding of Ionization Collection

The Cryogenic Dark Matter Search (CDMS) is searching for Weakly Interacting Massive Particles (WIMPs) with cryogenic particle detectors. These detectors have the ability to discriminate between nuclear recoil candidate and electron recoil background events by collecting both phonon and ionization energy from recoils in the detector crystals. The CDMS-II experiment has completed analysis of the first data runs with 30 semiconductor detectors at the Soudan Underground Laboratory, resulting in a world leading WIMP-nucleon spin-independent cross section limit for WIMP masses above 44 GeV/c 2 . As CDMS aims to achieve greater WIMP sensitivity, it is necessary to increase the detector mass and discrimination between signal and background events. Incomplete ionization collection results in the largest background in the CDMS detectors as this causes electron recoil background interactions to appear as false candidate events. Two primary causes of incomplete ionization collection are surface and bulk trapping. Recent work has been focused on reducing surface trapping through the modification of fabrication methods for future detectors. Analyzing data taken with test devices has shown that hydrogen passivation of the amorphous silicon blocking layer worsens surface trapping. Additional data has shown that the iron-ion implantation used to lower the critical temperature of the tungsten transition-edge sensors causes a degradation of the ionization collection. Using selective implantation on future detectors may improve ionization collection for events near the phonon side detector surface. Bulk trapping is minimized by neutralizing ionized lattice impurities. Detector investigations at testing facilities and in situ at the experimental site have provided methods to optimize the neutralization process and monitor running conditions to maintain full ionization collection. This work details my contribution to the 5-tower data taking, monitoring, and analysis effort as well as the SuperCDMS detector development with the focus on monitoring and improving ionization collection in the detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing the design and analysis of cryogenic semiconductor dark matter detectors for maximum sensitivity

In this thesis, we illustrate how the complex E- field geometry produced by interdigitated electrodes at alternating voltage biases naturally encodes 3D fiducial volume information into the charge and phonon signals and thus is a natural geometry for our next generation dark matter detectors. Secondly, we will study in depth the physics of import to our devices including transition edge sensor dynamics, quasi- particle dynamics in our Al collection fins, and phonon physics in the crystal itself so that we can both understand the performance of our previous CDMS II device as well as optimize the design of our future devices. Of interest to the broader physics community is the derivation of the ideal athermal phonon detector resolution and it's T 3 c scaling behavior which suggests that the athermal phonon detector technology developed by CDMS could also be used to discover coherent neutrino scattering and search for non-standard neutrino interaction and sterile neutrinos. These proposed resolution optimized devices can also be used in searches for exotic MeV-GeV dark matter as well as novel background free searches for 8GeV light WIMPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Dark Matter Results from the CDMS 5-Tower Run and the path towards {sigma} = 10{sup -46} cm{sup 2} Wimp sensitivity

This paper will report on the recently released results from the Cryogenic Dark Matter Search (CDMS II) experiment. Data from 30 cryogenic particle detectors operated at the Soudan Underground Laboratory between October 2006 and July 2007 was collected. The results from from a blind analysis of 15 Ge detectors corresponding to total exposure of 121.3 kg-d (averaged over the recoil energy range 10-100 keV, and weighted for a weakly interacting massive particle (WIMP) mass of 60 GeV/c{sup 2}) are presented here. With zero observed events an upper limit on WIMP-nucleon spin-independent cross section of 6.6x10{sup -44} cm{sup 2} is obtained from this data set alone. The limit improves to 4.6x10{sup -44} cm{sup 2} when combined with previous CDMS data. The paper will also describe current efforts at designing and building larger mass detectors ({approx}few kg/detector) which will form the basis of a future 1-Ton cryogenic Ge detector experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Report on Research in Experimental High Energy Physics

In the past three years the groups supported by the DOE have all made significant progress and posted major successes. The Minnesota CMS group has played leading roles in five data analyses and has had major roles in detector operations, the data management and the detector upgrades that are planned for for the LHC and those that are planned for the high-luminosity LHC. The CDMS-II experiment held the lead in WIMP sensitivity over the last decade, and is still the most sensitive detector in the world in the low WIMP mass region, with a recent 3σ hint of 8 GeV/c 2 WIMP candidates in the silicon data. SuperCDMS, with three orders of magnitude better electron recoil background rejection, has been collecting data since October 2011. Since all dark matter experiments require a better understanding of neutron backgrounds to make further advances in sensitivity, Cushman has expanded the Minnesota effort on backgrounds to the national level, where she is leading a coordinated effort in neutron simulations for underground physics. The work of Mandic on 100 mm detectors both for Super-CDMS and beyond has advanced rapidly. Also at the Intensity Frontier, the BESIII experiment has had a successful year of operation largely focused on searches for and studies of new "charmonium-like" states above DD threshold. At least one new state has been observed so far, with hints of others. An intensive effort to understand their nature and gain new insight into the strong interaction continues. BESIII has also produced a large number of other results in charmonium decay and light-hadronic physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The unbearable lightness of being: CDMS versus XENON

The CDMS-II collaboration has reported 3 events in a Si detector, which are consistent with being nuclear recoils due to scattering of Galactic dark matter particles with a mass of ∼ 8.6 GeV and a cross-section on neutrons of ∼ 2 × 10{sup −41} cm{sup 2}. While a previous result from the XENON10 experiment has supposedly ruled out such particles as dark matter, we find by reanalysing the XENON10 data that this is not the case. Some tension remains however with the upper limit placed by the XENON100 experiment, independently of astrophysical uncertainties concerning the Galactic dark matter distribution. We explore possible ways of ameliorating this tension by altering the properties of dark matter interactions. Nevertheless, even with standard couplings, light dark matter is consistent with both CDMS and XENON10/100.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Design for SuperCDMS SNOLAB

Beyond the present dark matter direct detection experiment at the Soudan underground laboratory, the SuperCDMS Collaboration is engaged in R and D activities for a 100-kg scale germanium dark matter experiment nominally sited at SNOLAB (2070 m overburden of rock). The expected sensitivity after 3 years of running is 3 x 10{sup -46} cm{sup 2} for the spin-independent cross section, an order of magnitude improvement over present exclusion limits for WIMP masses {approx}80 GeV/c{sup 2}. At this depth, and appropriate design of shielding and cryostat, neutron backgrounds will be negligible. The baseline design is an expanded version of CDMS II with Ge substrates (100 x 33 mm discs) instrumented with the iZIP phonon sensor layout to achieve the electron surface-event rejection power required.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing Scalar Dark Matter with Direct Experimental Searches and the LHC

The standard model (SM) plus a real gauge-singlet scalar field called darkon (SM+D) is the simplest model possessing a weakly interacting massive particle (WIMP) dark-matter candidate. The upper limits for the WIMP-nucleon elastic cross-section as a function of WIMP mass recently set by the direct-search experiments XENON10 and CDMS II rule out darkon mass ranges from 10 to (50, 70, 75) GeV for Higgs-boson masses of (120, 200, 350) GeV, respectively. This may exclude the possibility of the darkon providing an explanation for the gamma-ray excess observed in the EGRET data. It is shown that by extending the SM+D to a two-Higgs-doublet model plus a darkon the experimental constraints on the WIMP-nucleon interactions can be evaded due to suppression occurring in some of the parameter space of the model. Moreover, the darkon model can also be probed in Higgs-boson searches at the CERN Large Hadron Collider (LHC).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of SuperCDMS 1-inch Ge Detectors

The newly commissioned SuperCDMS Soudan experiment aims to search for WIMP dark matter with a sensitivity to cross sections of 5x10{sup -45}cm{sup 2} and larger (90% CL upper limit). This goal is facilitated by a new set of germanium detectors, 2.5 times more massive than the ones used in the CDMS-II experiment, and with a different athermal phonon sensor layout that eliminates radial degeneracy in position reconstruction of high radius events. We present characterization data on these detectors, as well as improved techniques for correcting position-dependent variations in pulse shape across the detector. These improvements provide surface-event discrimination sufficient for a reach of 5x10{sup -45}cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stable Higgs Bosons - new candidate for cold dark matter

The Higgs boson is in the backbone of the standard model of electroweak interactions. It must exist in some form for achieving unification of interactions. In the gauge-Higgs unification scenario the Higgs boson becomes a part of the extra-dimensional component of gauge fields. The Higgs boson becomes absolutely stable in a class of the gauge-Higgs unification models, serving as a promising candidate for cold dark matter in the universe. The observed relic abundance of cold dark matter is obtained with the Higgs mass around 70 GeV. The Higgs-nucleon scattering cross section is found to be close to the recent CDMS II XENON10 bounds in the direct detection of dark matter. In collider experiments stable Higgs bosons are produced in a pair, appearing as missing energies momenta so that the way of detecting Higgs bosons must be altered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The distribution of dark matter in the Milky Way's disk

We present an analysis of the effects of dissipational baryonic physics on the local dark matter (DM) distribution at the location of the Sun, with an emphasis on the consequences for direct detection experiments. Our work is based on a comparative analysis of two cosmological simulations with identical initial conditions of a Milky Way halo, one of which (Eris) is a full hydrodynamic simulation and the other (ErisDark) is a DM-only one. We find that in Eris two distinct processes lead to a 30% enhancement of DM in the disk plane at the location of the Sun: the accretion and disruption of satellites resulting in a DM component with net angular momentum, and the contraction of baryons pulling the DM into the disk plane without forcing it to co-rotate. Owing to its particularly quiescent merger history for dark halos of Milky Way mass, the co-rotating dark disk in Eris is less massive than what has been suggested by previous work, contributing only 9% of the local DM density. Yet, since the simulation results in a realistic Milky Way analog galaxy, its DM halo provides a plausible alternative to the Maxwellian standard halo model (SHM) commonly used in direct detection analyses. The speed distribution in Eris is broadened and shifted to higher speeds, compared to its DM-only twin simulation ErisDark. At high speeds f(v) falls more steeply in Eris than in ErisDark or the SHM, easing the tension between recent results from the CDMS-II and XENON100 experiments. The non-Maxwellian aspects of f(v) are still present, but much less pronounced in Eris than in the DM-only runs. The weak dark disk increases the time-averaged scattering rate by only a few percent at low recoil energies. On the high velocity tail, however, the increase in typical speeds due to baryonic contraction results in strongly enhanced mean scattering rates compared to ErisDark, although they are still suppressed compared to the SHM. Similar trends are seen regarding the amplitude of the annual modulation, while the modulated fraction is increased compared to the SHM and decreased compared to ErisDark.

79 ASTRONOMY AND ASTROPHYSICS↗

A particle dark matter footprint on the first generation of stars

Dark matter particles with properties identical to those of dark matter candidates hinted at by several international collaborations dedicated to the experimental detection of dark matter (DAMA, COGENT, CRESST, and CDMS-II, although not, most notably, by LUX), which also have a dark matter asymmetry that is identical to the observed baryon asymmetry (Planck and Wilkinson Microwave Anisotropy Probe), may produce a significant impact on the evolution of the first generation of low-metallicity stars. The lifetimes of these stars in different phases of stellar evolution are significantly extended, namely, in the pre-main sequence, main sequence, and red giant phases. In particular, intermediate-mass stars in the red giant phase experience significant changes in their luminosity and chemical composition. The annihilations of dark matter particles affect the interior of the star in such a way that the 3α reaction becomes less efficient in the production of carbon and oxygen. This dark matter effect contradicts the excess of carbon and other metals observed today in stars of low mass and low metallicity. Hence, we can impose an upper limit on the dark matter halo density, and therefore on the redshift, at which the first generation of low-metallicity stars formed.