Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CASE METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans

Purpose: The aim of this work was to develop a treatment planning workflow for rapid radiotherapy delivered with very high-energy electron (VHEE) scanning pencil beams of 60–120 MeV and to study VHEE plans as a function of VHEE treatment parameters. Additionally, VHEE plans were compared to clinical state-of-the-art volumetric modulated arc therapy (VMAT) photon plans for three cases. Methods: VHEE radiotherapy treatment planning was performed by linking EGSnrc Monte Carlo (MC) dose calculations with inverse treatment planning in a research version of RayStation. In order to study the effect of VHEE treatment parameters on VHEE dose distributions, a MATLAB graphical user interface (GUI) for calculation of VHEE MC pencil beam doses was developed. Through the GUI, pediatric case MC simulations were run for a number of beam energies (60, 80, 100, and 120 MeV), number of beams (13, 17, and 36), pencil beam spot (0.1, 1.0, and 3.0 mm) and grid (2.0, 2.5, and 3.5 mm) sizes, and source-to-axis distance, SAD (40 and 50 cm). VHEE plans for the pediatric case calculated with the different treatment parameters were optimized and compared. Furthermore, 100 MeV VHEE plans for the pediatric case, a lung, and a prostate case were calculated and compared to the clinically delivered VMAT plans. All plans were normalized such that the 100% isodose line covered 95% of the target volume. Results: VHEE beam energy had the largest effect on the quality of dose distributions of the pediatric case. For the same target dose, the mean doses to organs at risk (OARs) decreased by 5%–16% when planned with 100 MeV compared to 60 MeV, but there was no further improvement in the 120 MeV plan. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams, but to a more modest degree (<8%). While pencil beam spacing and SAD had a small effect on VHEE dose distributions, 0.1–3 mm pencil beam sizes resulted in identical dose distributions. For the 100 MeV VHEE pediatric plan, OAR doses were up to 70% lower and the integral dose was 33% lower for VHEE compared to 6 MV VMAT. Additionally, VHEE conformity indices (CI{sub 100} = 1.09 and CI{sub 50} = 4.07) were better than VMAT conformity indices (CI{sub 100} = 1.30 and CI{sub 50} = 6.81). The 100 MeV VHEE lung plan resulted in mean dose decrease to all OARs by up to 27% for the same target coverage compared to the clinical 6 MV flattening filter-free (FFF) VMAT plan. The 100 MeV prostate plan resulted in 3% mean dose increase to the penile bulb and the urethra, but all other OAR mean doses were lower compared to the 15 MV VMAT plan. The lung case CI{sub 100} and CI{sub 50} conformity indices were 3% and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. The prostate case CI{sub 100} and CI{sub 50} conformity indices were 1% higher and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. Conclusions: The authors have developed a treatment planning workflow for MC dose calculation of pencil beams and optimization for treatment planning of VHEE radiotherapy. The authors have demonstrated that VHEE plans resulted in similar or superior dose distributions for pediatric, lung, and prostate cases compared to clinical VMAT plans.

60 APPLIED LIFE SCIENCES↗

On the analysis of signal peaks in pulse-height spectra

The estimation of the signal location and intensity of a peak in a pulse height spectrum is important for X- ray and γ-ray spectroscopy, charged-particle spectrometry, liquid chromatography, and many other subfields. However, both the ‘‘centroid’’ and ‘‘signal intensity’’ of a peak in a pulse-height spectrum are ill-defined quantities and different methods of analysis will yield different numerical results. Here, we apply three methods of analysis. Method A is based on simple count summation and is likely the technique most frequently applied in practice. The analysis is straightforward and fast, and does not involve any statistical modeling. We find that it provides reliable results only for high signal-to-noise data, but has severe limitations in all other cases. Method B employs a Bayesian model to extract signal counts and centroid from the measured total and background counts. The resulting values are derived from the respective posteriors and, therefore, have a rigorous statistical meaning. The method makes no assumptions about the peak shape. It yields reliable and relatively small centroid uncertainties. However, it provides relatively large signal count uncertainties. Method C makes a strong assumption regarding the peak shape by fitting a Gaussian function to the data. Furthermore, the fit is based again on a Bayesian model. Although Method C requires careful consideration of the Gaussian width (usually given by the detector resolution) used in the fitting, it provides reliable values and relatively small uncertainties both for the signal counts and the centroid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-H-19A-01: FEATURED PRESENTATION - Treatment Planning Tool for Radiotherapy with Very High-Energy Electron Beams

Purpose: To develop a tool for treatment planning optimization for fast radiotherapy delivered with very high-energy electron beams (VHEE) and to compare VHEE plans to state-of-the-art plans for challenging pelvis and H'N cases. Methods: Treatment planning for radiotherapy delivered with VHEE scanning pencil beams was performed by integrating EGSnrc Monte Carlo (MC) dose calculations with spot scanning optimization run in a research version of RayStation. A Matlab GUI for MC beamlet generation was developed, in which treatment parameters such as the pencil beam size and spacing, energy and number of beams can be selected. Treatment planning study for H'N and pelvis cases was performed and the effect of treatment parameters on the delivered dose distributions was evaluated and compared to the clinical treatment plans. The pelvis case with a 691cm3 PTV was treated with 2-arc 15MV VMAT and the H'N case with four PTVs with total volume of 531cm3 was treated with 4-arc 6MV VMAT. Results: Most studied VHEE plans outperformed VMAT plans. The best pelvis 80MeV VHEE plan with 25 beams resulted in 12% body dose sparing and 8% sparing to the bowel and right femur compared to the VMAT plan. The 100MeV plan was superior to the 150MeV plan. Mixing 100 and 150MeV improved dose sparing to the bladder by 7% compared to either plan. Plans with 16 and 36 beams did not significantly affect the dose distributions compared to 25 beam plans. The best H'N 100MeV VHEE plan decreased mean doses to the brainstem, chiasm, and both globes by 10-42% compared to the VMAT plan. Conclusion: The pelvis and H'N cases suggested that sixteen 100MeV beams might be sufficient specifications of a novel VHEE treatment machine. However, optimum machine parameters will be determined with the presented VHEE treatment-planning tool for a large number of clinical cases. BW Loo and P Maxim received research support from RaySearch Laboratories. E Hynning and B Hardemark are employees of RaySearch Laboratories.

60 APPLIED LIFE SCIENCES↗

Image-based modeling of tumor shrinkage in head and neck radiation therapy

Purpose: Understanding the kinetics of tumor growth/shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy. This article presents a novel framework for image-based modeling of tumor change and demonstrates its performance with synthetic images and clinical cases. Methods: Due to significant tumor tissue content changes, similarity-based models are not suitable for describing the process of tumor volume changes. Under the hypothesis that tissue features in a tumor volume or at the boundary region are partially preserved, the kinetic change was modeled in two steps: (1) Autodetection of homologous tissue features shared by two input images using the scale invariance feature transformation (SIFT) method; and (2) establishment of a voxel-to-voxel correspondence between the images for the remaining spatial points by interpolation. The correctness of the tissue feature correspondence was assured by a bidirectional association procedure, where SIFT features were mapped from template to target images and reversely. A series of digital phantom experiments and five head and neck clinical cases were used to assess the performance of the proposed technique. Results: The proposed technique can faithfully identify the known changes introduced when constructing the digital phantoms. The subsequent feature-guided thin plate spline calculation reproduced the ''ground truth'' with accuracy better than 1.5 mm. For the clinical cases, the new algorithm worked reliably for a volume change as large as 30%. Conclusions: An image-based tumor kinetic algorithm was developed to model the tumor response to radiation therapy. The technique provides a practical framework for future application in adaptive radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Root Cause Analysis of Gastroduodenal Ulceration After Yttrium-90 Radioembolization

Introduction: A root cause analysis was performed on the occurrence of gastroduodenal ulceration after hepatic radioembolization (RE). We aimed to identify the risk factors in the treated population and to determine the specific mechanism of nontarget RE in individual cases. Methods: The records of 247 consecutive patients treated with yttrium-90 RE for primary (n = 90) or metastatic (n = 157) liver cancer using either resin (n = 181) or glass (n = 66) microspheres were reviewed. All patients who developed a biopsy-proven microsphere-induced gastroduodenal ulcer were identified. Univariate and multivariate analyses were performed on baseline parameters and procedural data to determine possible risk factors in the total population. Individual cases were analyzed to ascertain the specific cause, including identification of the culprit vessel(s) leading to extrahepatic deposition of the microspheres. Results: Eight patients (3.2 %) developed a gastroduodenal ulcer. Stasis during injection was the strongest independent risk factor (p = 0.004), followed by distal origin of the gastroduodenal artery (p = 0.004), young age (p = 0.040), and proximal injection of the microspheres (p = 0.043). Prolonged administrations, pain during administration, whole liver treatment, and use of resin microspheres also showed interrelated trends in multivariate analysis. Retrospective review of intraprocedural and postprocedural imaging showed a probable or possible culprit vessel, each a tiny complex collateral vessel, in seven patients. Conclusion: Proximal administrations and those resulting in stasis of flow presented increased risk for gastroduodenal ulceration. Patients who had undergone bevacizumab therapy were at high risk for developing stasis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Use of Quartic Force Fields in Variational Calculations

The use of quartic force fields (QFFs) has been shown to be one of the most effective ways to efficiently compute vibrational frequencies for small molecules. In this paper we outline and discuss how the simple-internal or bond-length bond-angle (BLBA) coordinates can be transformed into Morse-cosine(-sine) coordinates which produce potential energy surfaces from QFFs that possess proper limiting behavior and can effectively describe the vibrational (or rovibrational) energy levels of an arbitrary molecular system. We investigate parameter scaling in the Morse coordinate, symmetry considerations, and examples of transformed QFFs making use of the MULTIMODE, TROVE, and VTET variational vibrational methods. Cases are referenced where variational computations coupled with transformed QFFs produce accuracies compared to experiment for fundamental frequencies on the order of 5 cm(exp −1) and often as good as 1 cm(exp −1).

quartic force field↗

Inferior Pancreaticoduodenal Artery Aneurysms Associated with Occlusive Lesions of the Celiac Axis: Diagnosis, Treatment Options, Outcomes, and Review of the Literature

Purpose. To describe the presentation, treatment, and outcomes for 14 patients with aneurysms of the inferior pancreaticoduodenal arteries associated with occlusive lesions of the celiac axis, and to review the literature for similar cases. Methods, Over a period of 12 years, 14 patients (10 women and 4 men) ranging in age from 26 to 50 (mean 46) years were demonstrated to have aneurysms of the inferior pancreaticoduodenal artery origin associated with stenosis or occlusion of the celiac axis. All patients were treated by a combination of surgery and interventional radiology. Results. Outcome data collected between 3 months and 4 years (mean 2 years) demonstrated that all aneurysms remained excluded, and all 14 patients were well. The 49 case reports in the literature confirm the findings of this cohort. Conclusion. In inferior pancreaticoduodenal artery aneurysm resulting from celiac occlusive disease, endovascular treatment is best achieved by stenting the celiac axis and/or embolizing the aneurysm when necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Introduction to the Material Point Method using a Case Study from Gas Dynamics

The Material Point Method (MPM) developed by Sulsky and colleagues is currently being used to solve many challenging problems involving large deformations and/or fragementations with considerable success as part of the Uintah code created by the CSAFE project. In order to understand the properties of this method an analysis of the considerable computational properties of MPM is undertaken in the context of model problems from gas dynamics. One aspect of the MPM method in the form used here is shown to have first order accuracy. Computational experiments using particle redistribution are described and show that smooth results with first order accuracy may be obtained.

97 MATHEMATICS AND COMPUTING↗

Optimizing spectroheliogram deconvolution methods : MaGIXS - A case study

Over the past five years, new methods to reconstruct spectrally pure maps of the Sun from spectroheliogram data have emerged. In particular, with the rebirth of long-abandoned slitless imaging spectroscopy, one may obtain both spatial and spectral information over a large field of view simultaneously. Yet, depending on the size of the extended source combined with the extent of spectral dispersion, there will be locations in the focal plane where spectral lines from different spatial locations overlap and must be deconvolved. An unfolding method has been successfully developed and demonstrated on the recent rocket flight MaGIXS, which observed several strong emission lines (9 to 30$\AA$) from different portions of two active regions. In the work we are going to present, we conduct a systematic investigation of the parameters that controls and optimizes the inversion method to unfold overlappogram data. We also demonstrate a derived method of the inversion that does not require previous assumptions on the thermal and ionization equilibrium and abundance state of the plasma.

Spectroheliogram↗

Model-based versus specific dosimetry in diagnostic context: Comparison of three dosimetric approaches

Purpose: The dosimetric assessment of novel radiotracers represents a legal requirement in most countries. While the techniques for the computation of internal absorbed dose in a therapeutic context have made huge progresses in recent years, in a diagnostic scenario the absorbed dose is usually extracted from model-based lookup tables, most often derived from International Commission on Radiological Protection (ICRP) or Medical Internal Radiation Dose (MIRD) Committee models. The level of approximation introduced by these models may impact the resulting dosimetry. The aim of this work is to establish whether a more refined approach to dosimetry can be implemented in nuclear medicine diagnostics, by analyzing a specific case. Methods: The authors calculated absorbed doses to various organs in six healthy volunteers administered with flutemetamol ({sup 18}F) injection. Each patient underwent from 8 to 10 whole body 3D PET/CT scans. This dataset was analyzed using a Monte Carlo (MC) application developed in-house using the toolkit GATE that is capable to take into account patient-specific anatomy and radiotracer distribution at the voxel level. They compared the absorbed doses obtained with GATE to those calculated with two commercially available software: OLINDA/EXM and STRATOS implementing a dose voxel kernel convolution approach. Results: Absorbed doses calculated with GATE were higher than those calculated with OLINDA. The average ratio between GATE absorbed doses and OLINDA’s was 1.38 ± 0.34 σ (from 0.93 to 2.23). The discrepancy was particularly high for the thyroid, with an average GATE/OLINDA ratio of 1.97 ± 0.83 σ for the six patients. Differences between STRATOS and GATE were found to be higher. The average ratio between GATE and STRATOS absorbed doses was 2.51 ± 1.21 σ (from 1.09 to 6.06). Conclusions: This study demonstrates how the choice of the absorbed dose calculation algorithm may introduce a bias when gamma radiations are of importance, as is the case in nuclear medicine diagnostics.

60 APPLIED LIFE SCIENCES↗

Influence of Nucleoshuttling of the ATM Protein in the Healthy Tissues Response to Radiation Therapy: Toward a Molecular Classification of Human Radiosensitivity

Purpose: Whereas post–radiation therapy overreactions (OR) represent a clinical and societal issue, there is still no consensual radiobiological endpoint to predict clinical radiosensitivity. Since 2003, skin biopsy specimens have been collected from patients treated by radiation therapy against different tumor localizations and showing a wide range of OR. Here, we aimed to establish quantitative links between radiobiological factors and OR severity grades that would be relevant to radioresistant and genetic hyperradiosensitive cases. Methods and Materials: Immunofluorescence experiments were performed on a collection of skin fibroblasts from 12 radioresistant, 5 hyperradiosensitive, and 100 OR patients irradiated at 2 Gy. The numbers of micronuclei, γH2AX, and pATM foci that reflect different steps of DNA double-strand breaks (DSB) recognition and repair were assessed from 10 minutes to 24 hours after irradiation and plotted against the severity grades established by the Common Terminology Criteria for Adverse Events and the Radiation Therapy Oncology Group. Results: OR patients did not necessarily show a gross DSB repair defect but a systematic delay in the nucleoshuttling of the ATM protein required for complete DSB recognition. Among the radiobiological factors, the maximal number of pATM foci provided the best discrimination among OR patients and a significant correlation with each OR severity grade, independently of tumor localization and of the early or late nature of reactions. Conclusions: Our results are consistent with a general classification of human radiosensitivity based on 3 groups: radioresistance (group I); moderate radiosensitivity caused by delay of nucleoshuttling of ATM, which includes OR patients (group II); and hyperradiosensitivity caused by a gross DSB repair defect, which includes fatal cases (group III).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-498: A Comparative Evaluation of 6MV Flatten Beam and Flattening Filter Free Photon Beam in Carcinoma Breast

Purpose: Aim of the current study is to look plan quality, treatment beam ON time for IMRT using 6MV FB (Flatten Beam) and FFFB (Flattening Filter Free Beam) in left breast cancer cases. Methods: Ten left breast cancer patients treated with breast conserving surgical (BCS) procedure approach and adjuvant radiotherapy were selected from the department database. Simultaneous Integrated boost (SIB) technique was used to irradiate the total left breast (PTV) to a dose of 50.40Gy with concomitant enhance to the lumpectomy cavity known as gross tumour volume (GTV) to a dose of 59.40Gy in 28 fractions. Plans 6MV FB IMRT and 6MV FFFB IMRT had been generated to achieve dose to 95% target volume (TV) and spare Organ at risks (OAR’s). Homogeneity index (HI), conformity index (CI), treatment monitor unit (MU),normal tissues integral dose (NTID) and low dose volume of normal tissue were compared. Results: There was no statistically huge difference among the plans with respect to target volume coverage, CI HI, Ipsilateral Lung and Breast. But statistically significant difference (p< 0.05) as observed in Heart, V5Gy of Contralateral Lung, MU’s NTID and low dose volume of normal tissue. Conclusion: 6MV FB and FFF beam produce almost equivalent plans in IMRT modality with admire to target volume coverage, HI, CI. Beam on time and NTID was determined to be much less in 6MV FFFB IMRT. FFF beam leads to a time saving treatment delivery and fewer NTID in cancer of left breast cases.

60 APPLIED LIFE SCIENCES↗

Critical Appraisal of Acuros XB and Anisotropic Analytic Algorithm Dose Calculation in Advanced Non-Small-Cell Lung Cancer Treatments

Purpose: To assess the clinical impact of the Acuros XB algorithm (implemented in the Varian Eclipse treatment-planning system) in non-small-cell lung cancer (NSCLC) cases. Methods and Materials: A CT dataset of 10 patients presenting with advanced NSCLC was selected and contoured for planning target volume, lungs, heart, and spinal cord. Plans were created for 6-MV and 15-MV beams using three-dimensional conformal therapy, intensity-modulated therapy, and volumetric modulated arc therapy with RapidArc. Calculations were performed with Acuros XB and the Anisotropic Analytical Algorithm. To distinguish between differences coming from the different heterogeneity management and those coming from the algorithm and its implementation, all the plans were recalculated assigning Hounsfield Unit (HU) = 0 (Water) to the CT dataset. Results: Differences in dose distributions between the two algorithms calculated in Water were <0.5%. This suggests that the differences in the real CT dataset can be ascribed mainly to the different heterogeneity management, which is proven to be more accurate in the Acuros XB calculations. The planning target dose difference was stratified between the target in soft tissue, where the mean dose was found to be lower for Acuros XB, with a range of 0.4% {+-} 0.6% (intensity-modulated therapy, 6 MV) to 1.7% {+-} 0.2% (three-dimensional conformal therapy, 6 MV), and the target in lung tissue, where the mean dose was higher for 6 MV (from 0.2% {+-} 0.2% to 1.2% {+-} 0.5%) and lower for 15 MV (from 0.5% {+-} 0.5% to 2.0% {+-} 0.9%). Mean doses to organs at risk presented differences up to 3% of the mean structure dose in the worst case. No particular or systematic differences were found related to the various modalities. Calculation time ratios between calculation time for Acuros XB and the Anisotropic Analytical Algorithm were 7 for three-dimensional conformal therapy, 5 for intensity-modulated therapy, and 0.2 for volumetric modulated arc therapy with RapidArc. Conclusion: The availability of Acuros XB could improve patient dose estimation, increasing the data consistency of clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-633: Dose Differences in Lung Cancer SBRT: The Influences of MLC Width

Purpose: The aim is to compare the plan dose distribution of lung SBRT with MLCs in different width. Methods: Cases with phase INSCLC were enrolled. 9 cases were undergone 4D-CT scanning in the supine position with both arms raised. 3D-CT images without IV contrast were afterwards acquired with 3mm thickness and used for dose calculations. ITV was generated by using the inspiration and expiration images. The ITV can be expanded by geometric set-up uncertainty (5 mm) to generate the PTV. All chest normal tissues including chest wall were contoured by doctors. A total dose of 55 Gy will be given in 5 fractions within 10–14 days with an inter fraction interval of 2–3 days. Guided by the RTOG trial 3502 protocol, 11–13 non-coplanar fields with 6MV photon were arranged. Three types of MLCs with width of 3mm, 5mm and 10mm at isocenter position, were used separately to generate a CRT plan for each case. Monte Carlo algorithm was applied to dose calculation. All plans were adjusted as possible to meet the dose constraints. Dose-volume parameters from plans as followed were compared and analysized: PTV V55Gy, COMPTV D70% (70% of normalization dose), volume A (body minus PTV), and R100% and R50% (the ratio of x% of prescription dose isoline volume to PTV volume). Results: MLCs, 3mm and 5mm wide, played the identical roles on dosimetry of the plans, excluding the parameter volume A (p<0.05). On the contrary, MLC with width of 10mm was significantly inferior to the other two types on most parameters (p<0.05). For R50%, all types contributed equally (p>0.05). Conclusion: For lung cancer SBRT, MLC width had influence to dosimetry, especially in irradiation area. Small size MLC, e.g. 3mm and 5mm, are helpful to generate a high quality treatment plan, which could meet the strict criteria for targets and OAR.

60 APPLIED LIFE SCIENCES↗

Distal Edge Stenosis After Stent Placement for Isolated Superior Mesenteric Artery Dissection: Mechanisms and Risk Factor Analysis

Purpose: To analyze factors potentially associated with the occurrence of distal edge stenosis after stent placement for isolated superior mesenteric artery dissection (ISMAD). Materials and Methods: Cases of consecutive patients who were diagnosed with spontaneous ISMAD between February 2010 and July 2018 were retrospectively identified. Of the 123 cases identified, 45 patients (42 men; three women) underwent endovascular stent placement and were included in the study. Univariate and multivariate analyses were used to assess factors potentially associated with distal edge stenosis. Results: The technical success rate among study patients was 100%. During 26.7 ± 17.3 months of follow-up, CT angiography demonstrated good distal edge patency in 25 patients (55.6%) and evidence of distal edge stenosis in 20 patients (44.4%). In univariate analysis, stent length (odds radio [OR] 1.03; 95% confidence interval [CI] 1.01, 1.06; P = .02), stent-to-vessel (S/V) diameter ratio (OR 2.27; 95% CI 1.35, 3.82; P < .01), and angulation at the distal edge (OR 1.05; 95% CI 1.00, 1.10; P =.03) were significantly associated with distal edge stenosis; only S/V diameter ratio (OR 3.36; 95% CI 1.41, 7.99; P < .01) and angulation at the distal edge (OR 1.12; 95% CI 1.01, 1.23; P =.03) retained this significance in multivariate analysis. Conclusions: Distal edge stenosis after stent placement for ISMAD is common. S/V diameter ratio and angulation at the distal edge are independent risk factors for distal edge stenosis in patients with ISMAD who undergo stent placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Multiregional Market-to-Market Congestion Management Through Exchange of Relief Cost Curve

This paper introduces a novel method for multiregional market-to-market (M2M) coordinated congestion management. It identifies shortcomings in existing M2M approaches, where Regional Transmission Organizations (RTOs) exchange shadow prices and relief requests to optimize congestion relief allocations across interconnected regions. Two methods are proposed to enhance flow and price convergence. The first method proposes that both Regional Transmission Organizations (RTOs) use state-estimator flows directly to determine relief requirements, eliminating delays and potential oscillations caused by using market flows calculated from the prior period under existing M2M approach. The second method involves exchanging transmission relief cost curves, enabling each RTOs to integrate other RTOs' relief costs curve into its real-time security-constrained economic dispatch (SCED). This method can effectively extend the coordination to multiple transmission lines and across more than two RTOs. The alternating direction method of multipliers (ADMM) is also applied to the M2M coordination problem and compared with the proposed methods. Case studies on small and large-scale systems demonstrate the effectiveness of these approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Calibration of helical tomotherapy machine using EPR/alanine dosimetry

Purpose: Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10x10 cm{sup 2} square field, with the detector at a reference depth of 10 cm in water and 100 cm source to surface distance (SSD) (AAPM TG-51) or 100 cm source-to-axis distance (SAD) (IAEA TRS-398). However, the maximum field size of a helical tomotherapy (HT) machine is 40x5 cm{sup 2} defined at 85 cm SAD. These nonstandard conditions prevent a direct implementation of these protocols. The purpose of this study is twofold: To check the absorbed dose in water and dose rate calibration of a tomotherapy unit as well as the accuracy of the tomotherapy treatment planning system (TPS) calculations for a specific test case. Method: Both topics are based on the use of electron paramagnetic resonance (EPR) using alanine as transfer dosimeter between the Laboratoire National Henri Becquerel (LNHB) {sup 60}Co-{gamma}-ray reference beam and the Institut Curie's HT beam. Irradiations performed in the LNHB reference {sup 60}Co-{gamma}-ray beam allowed setting up the calibration method, which was then implemented and tested at the LNHB 6 MV linac x-ray beam, resulting in a deviation of 1.6% (at a 1% standard uncertainty) relative to the reference value determined with the standard IAEA TRS-398 protocol. Results: HT beam dose rate estimation shows a difference of 2% with the value stated by the manufacturer at a 2% standard uncertainty. A 4% deviation between measured dose and the calculation from the tomotherapy TPS was found. The latter was originated by an inadequate representation of the phantom CT-scan values and, consequently, mass densities within the phantom. This difference has been explained by the mass density values given by the CT-scan and used by the TPS which were not the true ones. Once corrected using Monte Carlo N-Particle simulations to validate the accuracy of this process, the difference between corrected TPS calculations and alanine measured dose values was then found to be around 2% (with 2% standard uncertainty on TPS doses and 1.5% standard uncertainty on EPR measurements). Conclusion: Beam dose rate estimation results were found to be in good agreement with the reference value given by the manufacturer at 2% standard uncertainty. Moreover, the dose determination method was set up with a deviation around 2% (at a 2% standard uncertainty).

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-81: Interplay Effect in Non-Gated Dynamic Treatment Delivery of a Lung Phantom with Simulated Respiratory Motion

Purpose: To quantify the interplay effect in non-gated VMAT external beam delivery using realistic, clinically relevant 3D motion in an anthropomorphic lung phantom, and to determine if adding margins is sufficient to account for motion or if gating is required in all cases. Methods: A 4D motion stage was used to move a Virtual Water (VW) lung target containing a piece of radiochromic EBT3 film in an anthropomorphic chest phantom. A five-arc stereotactic body radiation therapy (SBRT) treatment was planned using a CT scan of the phantom in its stationary position, using planning parameters chosen to push the optimizer to achieve a highly-modulated plan. Two scenarios were delivered using a Varian TrueBeam: the first was delivered with the phantom and target both stationary and the second was delivered with the phantom stationary but the target moving in a realistic, irregular 3D elliptical pattern. A single piece of 4×4 cm{sup 2} film was used per fraction, located in the central coronal plane of the target. Film was calibrated on a 6 MV beam with dose values from 0.20 to 20 Gy. Results: Preliminary test films were analyzed in ImageJ and MatLab software. Dose maps were calculated on a central region of interest (ROI) delineated on both the motion-induced and stationary films. Both static and dynamic film dose maps agreed with planning values within acceptable uncertainty. Conclusion: Including a large number of arcs in a clinically realistic SBRT treatment could reduce the effect of motion interplay due to averaging. Because all clinics do not employ multiple arcs for SBRT lung treatments, it is still important to consider the effects of motion on treatment delivery. Further analysis on the treatment films, as well as a broader investigation other planning parameters, will be conducted.

60 APPLIED LIFE SCIENCES↗