At least 73 records · Page 4

Recent Advancements in Electrical Capacitance Mass Gauging for Cryogenic PropellantTanks

The current lack of unsettled mass gauging is a key roadblock for many space activities, such as orbital refueling, missions to the Moon and Mars, and nuclear thermal and nuclear electric propulsion technologies. Liquid can form any one of an infinite number of configurations in microgravity, such as floating in globs or accumulating on tank surfaces in discontiguous volumes, or both. Capacitive sensing requires no moving parts and dissipates close to zero heat, making it an ideal candidate for cryogenic fluid mass gauging in settled and unsettled configurations. Capacitive sensing has a history of proven use in space propellant tanks, including tanks on the space shuttle, Saturn V, and the Apollo Lunar Excursion Module. Modern capacitive sensor technology allows using the entire tank as the capacitor volume by placing electrodes on the tank walls and propellant management surfaces. Capacitance is directly related to density, and therefore to mass for fixed volumes. In this presentation, we discuss the concepts behind whole-tank capacitance mass gauging and associated engineering challenges. We describe recent efforts to develop a micro-g unsettled cryogenic mass gauge using whole-tank capacitance sensing, including the development of test beds, electronics, and algorithms. We describe several mathematical processing techniques, including empirical-based averaging, electrical capacitance volume tomography, and spatial regularization. A modeling study, performed using settled configurations in gravity and no gravity, and with a set of 100 random fluid configurations, has indicated that spatial regularization, in which capacitance measurements are weighted to account for non-uniform electric fields, yields a mass fraction accuracy of 8% for any fluid configuration. Such a sensor is expected to operate in real time with a sampling frequency of at least 1 kHz.

cryogenic↗

Capacitive Energy Extraction by Few-Layer Graphene Electrodes

Capacitive double-layer expansion is a promising technology to harvest energy arising from the salinity difference between freshwater and seawater. Its optimal performance requires a careful selection of the operation potentials and electrode materials. While carbonaceous materials such as graphene and various forms of activated carbons are routinely used as the electrodes, there is little knowledge on how the quantum capacitance and the electric double-layer (EDL) capacitance, which are on the same order of magnitude, affect the capacitive performance. Toward understanding that from a theoretical perspective, here we study the capacitive energy extraction with graphene electrodes as a function of the number of graphene layers. The classical density functional theory is joined with the electronic density functional theory to obtain the EDL and the quantum capacitance, respectively. The theoretical results show that the quantum capacitance contribution plays a dominant role in extracting energy using the single-layer graphene, but its effect diminishes as the number of graphene layers increases. The overall extracted energy is dominated by the EDL contribution beyond about four graphene layers. Electrodes with more graphene layers are able to extract more energy at low charging potential. Here, because many porous carbons have nanopores with stacked graphene layers, our theoretical predictions are useful to identify optimal operation parameters for capacitive energy extraction with porous electrodes of different wall thickness.

36 MATERIALS SCIENCE↗

Twin-capacitive shaft angle encoder with analog output signal

A precision capacitive shaft encoder providing a dc signal corresponding to the angular position of a shaft is described. Two variable capacitances are coupled in tandem by a rotatable shaft. Each capacitor has a capacitance that varies linearly with a change in the angular position of the shaft. The sum of the two capacitances is always constant for any angular position of the shaft. Each capacitance is alternately coupled to a reference dc voltage and a discharge circuit. The capacitances are electrically coupled in series and the charge periodically acquired at the junction of the capacitance is a function of the position of the shaft. An error-compensating voltage is imposed on the junction when the capacitances are coupled to the reference voltages. The junction is coupled to sample-and-hold apparatus provided with a error-correcting circuit.

Hruby, R. J.↗

Capacitive Sensors for Measuring Masses of Cryogenic Fluids

An effort is under way to develop capacitive sensors for measuring the masses of cryogenic fluids in tanks. These sensors are intended to function in both microgravitational and normal gravitational settings, and should not be confused with level sensors, including capacitive ones. A sensor of this type is conceptually simple in the sense that (1) it includes only one capacitor and (2) if properly designed, its single capacitance reading should be readily convertible to a close approximation of the mass of the cryogenic fluid in the tank. Consider a pair of electrically insulated electrodes used as a simple capacitive sensor. In general, the capacitance is proportional to the permittivity of the dielectric medium (in this case, a cryogenic fluid) between the electrodes. The success of design and operation of a sensor of the present type depends on the accuracy of the assumption that to a close approximation, the permittivity of the cryogenic fluid varies linearly with the density of the fluid. Data on liquid nitrogen, liquid oxygen, and liquid hydrogen, reported by the National Institute of Standards and Technology, indicate that the permittivities and densities of these fluids are, indeed, linearly related to within a few tenths of a percent over the pressure and temperature regions of interest. Hence, ignoring geometric effects for the moment, the capacitance between two electrodes immersed in the fluid should vary linearly with the density, and, hence, with the mass of the fluid. Of course, it is necessary to take account of the tank geometry. Because most cryogenic tanks do not have uniform cross sections, the readings of level sensors, including capacitive ones, are not linearly correlated with the masses of fluids in the tanks. In a sensor of the present type, the capacitor electrodes are shaped so that at a given height, the capacitance per unit height is approximately proportional to the cross-sectional area of the tank in the horizontal plane at that height (see figure).

Nurge, Mark↗

Capacitive wireless power transfer circuit and related techniques

Capacitive wireless power transfer systems are provided. In one embodiment, for example, the system comprises two pair of coupled conducting plates; a first matching network coupled to the first pair of conducting plates; and a second matching network coupled to the second pair of conducting plates. At least one of the first and second matching networks comprises an inductor having inductance value selected based on at least one parasitic capacitance value of the capacitive wireless power transfer system. In another embodiment, a method of designing a capacitive wireless power transfer system is provided comprising determining a parasitic capacitance value of a capacitive wireless power transfer system and determining an inductance value of an inductor of at least one of the first and second matching network having a value selected based on at least one parasitic capacitance value of the capacitive wireless power transfer system.

Afridi, Khurram K.↗

Optical power dependence of capacitance in uni-traveling-carrier photodetectors

Optical power dependence of capacitance in uni-traveling-carrier photodetectors is analyzed by founding a differential capacitance model. The trend of capacitance variation against optical power by simulation gets a good agreement with the measured results. The relationship between light-intensity-dependent capacitance and DC saturation characteristics of the device is also investigated at different collection layer thicknesses. The optical power at the maximum point of capacitance is near that at the DC saturation point. With the thickness of collection layer increasing, the maximum capacitance decreases and optical power at capacitance maximum point also becomes small.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computational insight into the capacitive performance of graphene edge planes

Recent experiments have shown that electric double-layer capacitors utilizing electrodes consisting of graphene edge plane exhibit higher capacitance than graphene basal plane. However, theoretical understanding of this capacitance enhancement is still limited. Here we applied a self-consistent joint density functional theory calculation on the electrode/electrolyte interface and found that the capacitance of graphene edge plane depends on the edge type: zigzag edge has higher capacitance than armchair edge due to the difference in their electronic structures. We further examined the quantum, dielectric, and electric double-layer (EDL) contributions to the total capacitance of the edge-plane electrodes. Classical molecular dynamics simulation found that the edge planes have higher EDL capacitance than the basal plane due to better adsorption of counter-ions and higher solvent accessible surface area. Finally, our work therefore has elucidated the capacitive energy storage in graphene edge planes that take into account both the electrode's electronic structure and the EDL structure.

36 MATERIALS SCIENCE↗

Interfacial negative capacitance in planar perovskite solar cells: An interpretation based on band theory

Highlights: • PSCs with different ETL strategies were characterized by EIS measurement under various conditions. • The negative capacitance solely occurred in the moderate frequency region when special conditions are met. • A model based on semiconductor band theory was proposed to interpret the corresponding mechanism. • This achievement provide important insight into the physical mechanism behind the negative capacitance of PSCs. - Abstract: The negative capacitance is a peculiar phenomenon frequently observed in electrochemical impedance spectroscopy (EIS) measurement for perovskite solar cells (PSCs). However, the origin and mechanism of the negative capacitance in PSCs remains ambiguous. Here, planar PSCs with different electron transport layer (ETL) strategies (SnO{sub 2}, TiO{sub 2}, or without ETL) were characterized by EIS in a wide range of frequencies under various conditions. The negative capacitance solely occurred in the moderate frequency region as the perovskite layer directly contacted with the conductive SnO{sub 2}: F (FTO) substrate under illumination and open-circuit conditions. Based on semiconductor band theory, the origin of negative capacitance to the formation of an inversion layer in the perovskite/FTO interface induced by the interfacial energy band over-bent under illumination and open-circuit conditions. Our study provides important insight into the physical mechanism behind the negative capacitance of PSCs.

36 MATERIALS SCIENCE↗

Impacts of Non-Ideal Back Contact on Capacitance Measurements in CdTe Solar Cells

CdTe solar cells suffer from a non-ideal back contact which can strongly affect the equivalent circuit model and complicate capacitance measurements. Here, five different back contact materials are deposited on identical CdTe absorbers and their influence on capacitance measurements is characterized. A five-element equivalent circuit model is shown to represent a CdTe solar cell with a non-ideal back contact, and capacitance-frequency (C-f) measurements on each sample clearly show the influence of this contact. Capacitance-voltage (C-V) measurements on each sample show the influence of frequency on measured capacitance. In the AlGaOx/Au sample, temperature dependent C-fs show the back barrier height to be 240 meV, and ongoing measurements will give a comparison of back barrier heights for all samples. This study provides insight into the efficacy of various back contacts and highlights potential errors in the interpretation of capacitance measurements due to the presence of the back contact.

cadmium compounds↗

Structure–Capacitance Relationships of Graphene/Ionic Liquid Electrolyte Double Layers

The differential capacitance profile of electrochemical interfaces reflects the physical properties of the double layer. For carbon electrodes and ionic liquid based electrolytes, these capacitance profiles are not fully understood. In this work, we utilize constant voltage molecular dynamics simulations to compute differential capacitance profiles of ionic liquids [BMIm + ][BF 4 - ] and [BMIm + ][TFSI - ] mixed with acetonitrile and 1,2-dichloroethane, at model graphene electrodes. We find that both pure and 10% mole fraction ionic liquid electrolytes exhibit camel shaped capacitance profiles with two peaks on either side of a minimum centered at the potential of zero charge. This profile shape results from electric field induced rearrangement of ion structure within the inner layer closest to the electrode interface. At low potential, the ionic liquid inner layer is concentrated with non-polar tri-fluoromethyl and butyl functional groups of the anions and cations, corresponding to the minimum of the capacitance profiles. With increasing voltage, electrostatic interactions of polar/charged functional groups with the electrode surface compete with these non-polar interactions, leading to ion rearrangement that increases the inner layer charge density and results in higher capacitance. After the ion restructuring is complete, the response saturates and capacitance diminishes. The presence of organic solvent significantly changes the composition of the inner layer. For example, strong non-polar interactions between dichloroethane molecules and the graphene surface substantially block ion/electrode contact at moderate potentials. Overall, our simulations highlight the dynamic nature of the inner region of organic electrolyte double layers, and the sensitive dependence on electrolyte composition and applied voltage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capacitive Detection of Low-Enthalpy, Higher-Order Phase Transitions in Synthetic and Natural Composition Lipid Membranes

In-plane lipid organization and phase separation in natural membranes play key roles in regulating many cellular processes. Highly cooperative, first-order phase transitions in model membranes consisting of few lipid components are well understood and readily detectable via calorimetry, densitometry, and fluorescence. However, far less is known about natural membranes containing numerous lipid species and high concentrations of cholesterol, for which thermotropic transitions are undetectable by the above-mentioned techniques. We demonstrate that membrane capacitance is highly sensitive to low-enthalpy thermotropic transitions taking place in complex lipid membranes. Specifically, we measured the electrical capacitance as a function of temperature for droplet interface bilayer model membranes of increasing compositional complexity, namely, (a) a single lipid species, (b) domain-forming ternary mixtures, and (c) natural brain total lipid extract (bTLE). We observed that, for single-species lipid bilayers and some ternary compositions, capacitance exhibited an abrupt, temperature-dependent change that coincided with the transition detected by other techniques. In addition, capacitance measurements revealed transitions in mixed-lipid membranes that were not detected by the other techniques. Most notably, capacitance measurements of bTLE bilayers indicated a transition at ~38 °C not seen with any other method. Likewise, capacitance measurements detected transitions in some well-studied ternary mixtures that, while known to yield coexisting lipid phases, are not detected with calorimetry or densitometry. These results indicate that capacitance is exquisitely sensitive to low-enthalpy membrane transitions because of its sensitivity to changes in bilayer thickness that occur when lipids and excess solvent undergo subtle rearrangements near a phase transition. Our findings also suggest that heterogeneity confers stability to natural membranes that function near transition temperatures by preventing unwanted defects and macroscopic demixing associated with high-enthalpy transitions commonly found in simpler mixtures.

59 BASIC BIOLOGICAL SCIENCES↗

Improving accuracy of electrochemical capacitance and solvation energetics in first-principles calculations

Here, reliable first-principles calculations of electrochemical processes require accurate prediction of the interfacial capacitance, a challenge for current computationally efficient continuum solvation methodologies. We develop a model for the double layer of a metallic electrode that reproduces the features of the experimental capacitance of Ag(100) in a non-adsorbing, aqueous electrolyte, including a broad hump in the capacitance near the potential of zero charge and a dip in the capacitance under conditions of low ionic strength. Using this model, we identify the necessary characteristics of a solvation model suitable for first-principles electrochemistry of metal surfaces in non-adsorbing, aqueous electrolytes: dielectric and ionic nonlinearity, and a dielectric-only region at the interface. The dielectric nonlinearity, caused by the saturation of dipole rotational response in water, creates the capacitance hump, while ionic nonlinearity, caused by the compactness of the diffuse layer, generates the capacitance dip seen at low ionic strength. We show that none of the previously developed solvation models simultaneously meet all these criteria. We design the nonlinear electrochemical soft-sphere solvation model which both captures the capacitance features observed experimentally and serves as a general-purpose continuum solvation model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trielectrode capacitive pressure transducer

A capacitive transducer and circuit especially suited for making measurements in a high-temperature environment are described. The transducer includes two capacitive electrodes and a shield electrode. As the temperature of the transducer rises, the resistance of the insulation between the capacitive electrode decreases and a resistive current attempts to interfere with the capacitive current between the capacitive electrodes. The shield electrode and the circuit coupled there reduce the resistive current in the transducer. A bridge-type circuit coupled to the transducer ignores the resistive current and measures only the capacitive current flowing between the capacitive electrodes.

Coon, G. W.↗

A system for measuring thermal activation energy levels in silicon by thermally stimulated capacitance

One method being used to determine energy level(s) and electrical activity of impurities in silicon is described. The method is called capacitance transient spectroscopy (CTS). It can be classified into three basic categories: the thermally stimulated capacitance method, the voltage-stimulated capacitance method, and the light-stimulated capacitance method; the first two categories are discussed. From the total change in capacitance and the time constant of the capacitance response, emission rates, energy levels, and trap concentrations can be determined. A major advantage of using CTS is its ability to detect the presence of electrically active impurities that are invisible to other techniques, such as Zeeman effect atomic absorption, and the ability to detect more than one electrically active impurity in a sample. Examples of detection of majority and minority carrier traps from gold donor and acceptor centers in silicon using the capacitance transient spectrometer are given to illustrate the method and its sensitivity.

Cockrum, R. H.↗

Influence of Charge Transport Layers on Capacitance Measured in Halide Perovskite Solar Cells

Capacitance-based techniques were previously used to measure the electrical properties of halide perovskite solar cells (PSCs) such as defect activation energy and density, carrier concentration, and dielectric constant, which provide key information for evaluating the device performance. Herein, we show that capacitance-based techniques cannot be used to reliably analyze the properties of defects in the perovskite layer or at its interface, since the high-frequency capacitance signature is due to the response of charge carriers in the hole-transport layer (HTL). For HTL-free PSCs, the high-frequency capacitance can be considered as the geometric capacitance for analyzing the dielectric constant of the perovskite layer, since there is no trapping and de-trapping of charge carriers in the perovskite layer. We also find that the low-frequency capacitance signature can be used to calculate the activation energy of the ionic conductivity of the perovskite layer, but the overlapping effects with charge transport materials must be avoided.

14 SOLAR ENERGY↗

Novel High Temperature Capacitive Pressure Sensor Utilizing SiC Integrated Circuit Twin Ring Oscillators

This paper describes initial development and testing of a novel high temperature capacitive pressure sensor system. The pressure sensor system consists of two 4H-SiC 11-stage ring oscillators and a SiCN capacitive pressure sensor. One oscillator has the capacitive pressure sensor fixed at one node in its feedback loop and varies as a function of pressure and temperature while the other provides a pressure-independent reference frequency which can be used to temperature compensate the output of the first oscillator. A two-day repeatability test was performed up to 500C on the oscillators and the oscillator fundamental frequency changed by only 1. The SiCN capacitive pressure sensor was characterized at room temperature from 0 to 300 psi. The sensor had an initial capacitance of 3.76 pF at 0 psi and 1.75 pF at 300 psi corresponding to a 54 change in capacitance. The integrated pressure sensor system was characterized from 0 to 300 psi in steps of 50 psi over a temperature range of 25 to 500C. The pressure sensor system sensitivity was 0.113 kHzpsi at 25C and 0.026 kHzpsi at 500C.

high temperature↗

Effect of reducing system on capacitive behavior of reduced graphene oxide film: Application for supercapacitor

To determine the best chemical reduction of graphene oxide film with hydriodic acid that gives maximum energy and power density, we studied the effect of two reducing systems, hydriodic acid/water and hydriodic acid/acetic acid, on the morphology and electrochemical features of reduced graphene oxide film. Using acetic acid as solvent results in high electrical conductivity (5195 S m{sup −1}), excellent specific capacitance (384 F g{sup −1}) and good cyclic stability (about 98% of its initial response after 4000 cycles). Using water as a solvent, results in an ideal capacitive behavior and excellent cyclic stability (about 6% increase of its initial response after 2100 cycles). - Graphical abstract: The choice of reducing system determines the morphology and structure of the chemically reduced graphene film and, as a result, affects largely the capacitive behavior. - Highlights: • The structure of the graphene film has a pronounced effect on capacitive behavior. • The use of water/HI as reducing system results in an ideal capacitive behavior. • The use of acetic acid/HI as reducing system results in a high specific capacitance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving the low-temperature capacitance of CoNiAl three-component layered double hydroxide in a redox electrolyte

Graphical abstract: The specific capacitance of CoNiAl layered double hydroxide in 6 M KOH reduces sharply from room temperature to −20 °C, which is effectively enhanced by adding redox pair Fe(CN){sub 6}{sup 3−}/Fe(CN){sub 6}{sup 4−} in the electrolyte. - Highlights: • CoNiAl layered double hydroxide is synthesized by homogeneous precipitation. • The specific capacitance reduces sharply with the decrease of temperature. • At −20 °C the specific capacitance is increased by 178% in a redox electrolyte. - Abstract: CoNiAl three-component layered double hydroxide with a lamellar structure similar to hydrotalcite-like compounds is synthesized via homogeneous precipitation and the effect of temperature on its capacitive performances in 6 M KOH is investigated. Electrochemical tests show its specific capacitance reduces sharply with the decrease of temperature from 18 to −20 °C. At −20 °C an increase of specific capacitance by 178% is achieved by adding redox pair Fe(CN){sub 6}{sup 3−}/Fe(CN){sub 6}{sup 4−} as the electron shuttle in the electrolyte due to their cooperation with the electrode reaction during the charge/discharge processes.

36 MATERIALS SCIENCE↗