X-Ray Calorimeter Arrays for Astrophysics

High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

Kilbourne, Caroline A.↗

Uncertainty Analysis of Coaxial Thermocouple Calorimeters Used in Arc Jets

Recent introduction of Coaxial Thermocouple type calorimeters into the NASA Ames arc jet facilities has inspired an analysis of 2D conduction effects internal to this type of calorimeter. The 1D finite slab inverse analysis (which is typically used to deduce the heat transfer to the calorimeter) relies on the assumption that lateral conduction (i.e., 2D effects) is negligible. Most calorimeter bodies have a spherical nose, which in itself is a violation of the 1D finite slab analysis assumption. Secondly most calorimeters experience a variation in heating across the face of the body which is also a violation of the 1D finite slab analysis assumption. It turns out that these two effects tend to cancel each other to some extent. This paper shows the extent to which error exists in the analysis of the Coaxial Thermocouple type calorimeters, and also offers analysis strategies for reducing the errors.

Lateral Conduction↗

Comparison of point cloud and image-based models for calorimeter fast simulation

Score based generative models are a new class of generative models that have been shown to accurately generate high dimensional calorimeter datasets. Recent advances in generative models have used images with 3D voxels to represent and model complex calorimeter showers. Point clouds, however, are likely a more natural representation of calorimeter showers, particularly in calorimeters with high granularity. Furthermore, point clouds preserve all of the information of the original simulation, more naturally deal with sparse datasets, and can be implemented with more compact models and data files. In this work, two state-of-the-art score based models are trained on the same set of calorimeter simulation and directly compared.

47 OTHER INSTRUMENTATION↗

Electromagnetic and hadron calorimeters in the MIPP experiment

The purpose of the MIPP experiment is to study the inclusive production of photons, pions, kaons, and nucleons in {pi}, K, and p interactions on various targets using beams from the Main Injector at Fermilab. The function of the calorimeters is to measure the production of forward-going neutrons and photons. The electromagnetic calorimeter consists of 10 lead plates interspersed with proportional chambers. It was followed by the hadron calorimeter with 64 steel plates interspersed with scintillator. The data presented were collected with a variety of targets and beam momenta from 5 to 120 GeV/c. The energy calibration of both calorimeters with electrons, pions, kaons, and protons is discussed. The resolution for electrons was found to be 0.27/{radical}E, and for hadrons the resolution was 0.554/{radical}E with a constant term of 2.6%. The performance of the calorimeters was tested on a neutron sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CsI calorimeter for the J-PARC KOTO experiment

An electromagnetic calorimeter made of undoped CsI crystals is used in the J-PARC KOTO experiment to search for new physics beyond the standard model with the KL → π 0 νν¯ decay. The calorimeter is designed to operate in vacuum of 0.1 Pa and in a high-rate environment where the counting rate due to KL decays is O(100) kHz. A special method to calibrate the calorimeter during the data taking without using a tracking system for charged particles is reported. The energy, position, and timing resolutions of the calorimeter were evaluated in several beam tests, and the resolutions satisfy the required performance. Finally, the energy resolution with the total energy E is 0.66 ⊕ 1.81/ √ E[GeV]% in the inner region of the calorimeter.

47 OTHER INSTRUMENTATION↗

Electromagnetic calorimeters based on scintillating lead tungstate crystals for experiments at Jefferson Lab

A new electromagnetic calorimeter consisting of 140 lead tungstate (PbWO 4 ) scintillating crystals was constructed for the PrimEx- η experiment at Jefferson lab. The calorimeter was integrated into the data acquisition and trigger systems of the GlueX detector and used in the experiment to reconstruct Compton scattering events. The experiment started collecting data in the spring of 2019 and acquired about 30% of the required statistics. The calorimeter is a prototype for two PbWO 4 -based detectors: the Neutral Particle Spectrometer (NPS) and the lead tungstate insert of the Forward CALorimeter (FCAL) of the GlueX detector. The article presents the design and performance of the Compton calorimeter and gives a brief overview of the FCAL and NPS projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research on calorimeter for high-power microwave measurements

Based on measurement of the volume increment of polar liquid that is a result of heating by absorbed microwave energy, two types of calorimeters with coaxial capacitive probes for measurement of high-power microwave energy are designed in this paper. The first is an “inline” calorimeter, which is placed as an absorbing load at the end of the output waveguide, and the second is an “offline” calorimeter that is placed 20 cm away from the radiation horn of the high-power microwave generator. Ethanol and high density polyethylene are used as the absorbing and housing materials, respectively. Results from both simulations and a “cold test” on a 9.3 GHz klystron show that the “inline” calorimeter has a measurement range of more than 100 J and an energy absorption coefficient of 93%, while the experimental results on a 9.3 GHz relativistic backward-wave oscillator show that the device’s power capacity is approximately 0.9 GW. The same experiments were also carried out for the “offline” calorimeter, and the results indicate that it can be used to eliminate the effects of the shock of the solenoid on the measurement curves and that the device has a higher power capacity of 2.5 GW. The results of the numerical simulations, the “cold tests,” and the experiments show good agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

WE-A-17A-02: BEST IN PHYSICS (THERAPY) - Development of a Calorimeter for the Measurement of the Power Emitted From LDR Brachytherapy Sources

Purpose: Model-based dose calculation algorithms for brachytherapy sources are designed to compute dose per particle or dose per unit energy leaving the encapsulation of a brachytherapy source. As such, the power leaving the encapsulation of a source, called emitted power (EP), would be a natural source strength metric for these new algorithms. However, no instrument is currently capable of an absolute measurement of EP. A calorimeter operating with a liquid helium thermal sink was designed and constructed to measure the EP of low-dose rate (LDR) I-125 and Pd-103 brachytherapy sources. Methods: Calorimeter design was optimized through thermal and Monte Carlo (MC) modeling. Thermal modeling showed that specific thermal conditions would be necessary for accurate calorimeter measurements. These conditions were experimentally verified. The EP of two LDR I-125 source models was measured. An air-kermastrength (AKS)-to-EP conversion coefficient was determined through MC simulations and applied to well-type ionization chamber measurements of AKS to enable comparison with EP measurements. Results: MCdetermined EP per unit AKS conversion coefficients were source model dependent and are on the order of 0.1 μW/U. The signal-to-noise ratio was a function of source strength, and was 294 for a 0.5 μW source. Measurements were repeatable to within 3.6% for a 0.5 μW source. Initial EP measurements were made with two I-125 source models, a 5.7 U Oncura 6711 and a 2.9 U Best Medical 2301. Model 2301 results agreed with the MC-converted AKS value to within the measurement uncertainty of 4.3% at k=1. The Model 6711 results were systematically high and are under investigation. Conclusion: A calorimeter was designed to provide an absolute measurement of the EP for LDR brachytherapy sources and preliminary EP measurements have been made. This new calorimeter design shows promise of providing a more fundamentally useful source strength standard.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP2-05: Development of a Thimble Calorimeter for Absorbed Dose to Water Characterized in MV Photons

Purpose: To develop a thimble sized polystyrene calorimeter for use from kV to MV photons, as a primary reference standard for applications from diagnostic CT imaging to therapy beam dose determination. Methods: A polystyrene calorimeter about 1.5 cm diameter embedded with small thermistors was characterized in a 6 MV photon beam from a clinical accelerator at 5 nominal dose rates from 0.8 to 4 Gy/min. Irradiations were delivered with beam on/off cycles first at 60 s and then at 20 s. Two sets of phantom conditions were evaluated: 1) in a 30 cm diameter polyethylene cylinder, and 2) in 10 cm depth of a 30 cm water phantom. The temperature waveforms were recorded and analyzed for temperature rise, arriving at a dose to polystyrene. This value is compared with the result of measurements under identical conditions using an ionization chamber calibrated for absorbed dose to water. Monte Carlo simulations were performed on the measurement systems to estimate such a ratio. Results: The ratio of the dose determined by the calorimeter to the dose reported by the ionization chamber was aggregated from all 5 dose rates. The 60 s results show a much elevated response in both phantoms compared to their respective expected results based on simulation. This deviation was reduced when the on/off cycles were shortened to 20 s. This behavior was possibly due to the heat conduction effects in the small calorimeter body. Finite element modeling is being conducted to simulate this effect. Conclusion: A small solid plastic calorimeter offers the convenience of a portable absorbed dose standard based on direct measurement of energy deposition, but comes at the expense of heat transfer complications which need to be characterized. This work offers preliminary evidence of the behavior and quantitative assessment of the issues to be resolved in future investigations.

60 APPLIED LIFE SCIENCES↗

Nuclear waste calorimeter for very large drums with 385 litres sample volume

Calorimetry is a very precise and well adapted tool for the classification of drums containing nuclear waste material depending on their level of activities (low, medium, high). A new calorimeter has been developed by SETARAM Instrumentation and the CEA Valduc in France. This new calorimeter is designed for drums having a volume bigger than 100 liters. It guarantees high operator safety by optimizing drum handling and air circulation for cooling, and optimized software for direct measurement of the quantity of nuclear material. The LVC1380 calorimeter makes it possible to work over the range 10 to 3000 mW, which corresponds to approximately 0.03 to 10 g of tritium or 3 to 955 g of {sup 241}Pu in a volume up to 385 liters. This calorimeter is based on the heat flow measurement using Peltier elements which surround the drum in the 3 dimensions and therefore measure all the heat coming from the radioactive stuff whatever its position inside the drum. Calorimeter's insulating layers constitute a thermal barrier designed to filter disturbances until they represent less than 0.001 Celsius degrees and to eliminate long term disturbances associated, for example, with laboratory temperature variations between day and night. A calibration device based on Joule effect has also been designed. Measurement time has been optimized but remains long compared with other methods of measurement such as gamma spectrometry but its main asset is to have a good accuracy for low level activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Energy 3D Calorimeter based on position-sensitive virtual Frisch-grid CdZnTe detectors for use in Gamma-ray Astronomy

We present a concept for a calorimeter based on a novel approach of 3D position-sensitive virtual Frischgrid CZT detectors. This calorimeter aims to measure photons with energies from ~100 keV to 10 (goal 50) MeV. The expected energy resolution at 662 keV is ~1% FWHM, and the photon interaction positionmeasurement accuracy is ~1 mm in all 3 dimensions. Each CZT bar is a rectangular prism with typical cross-section of 6x6 mm 2 and length of 2-4 cm. The bars are arranged in modules of 4 x 4 bars, and the modules themselves can be assembled into a larger array. The 3D virtual voxel approach solves a long-standing problem with CZT detectors associated with material imperfections that limit the performance and usefulness of relatively thick detectors (i.e., > 1 cm). Also, it allows us to relax the requirements on the quality of the crystals, maintaining good energy resolution and significantly reducing the instrument cost. Such a calorimeter can be successfully used in space telescopes that use Compton scattering of γ rays, such as AMEGO, serving as part of its calorimeter and providing the position and energy measurement for Compton-scattered photons. Also, it could provide suitable energy resolution to allow for spectroscopic measurements of γ-ray lines from nuclear decays. Another viable option is to use this calorimeter as a focal plane to conduct spectroscopic measurements of cosmic γ-ray events. In combination with a coded-aperture mask, it potentially could provide mapping of the 511-keV radiation from the Galactic Center region.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Upgrade fo the CMS Hadron Outer Calorimeter with SIPMs

The CMS Hadron Outer Calorimeter (HO) is undergoing an upgrade to replace the existing photodetectors (HPDs) with SIPMs. The chosen device is the Hamamatsu 3 x 3mm 50 {mu}m pitch MPPC. The system has been developed to be a 'drop-in' replacement of the HPDs. A complete control system of bias voltage generation, leakage current monitoring, temperature monitoring, and temperature control using solid state Peltier coolers has been developed and tested. 108 channels of the system have been installed into CMS and operated for more than 2 years. The complete system of about 2200 channels is in production and will be installed in the next LHC long shutdown scheduled for 2013. The CMS central calorimeter consists of a detector inside the solenoidal magnet, HB, and a component outside the magnet, the Outer Hadron Calorimeter, HO [1]. The HO is installed inside the magnet flux return yoke and provides for typically 3{lambda} of additional absorber to the calorimetric measurement. The outer calorimeter is composed of one or more layers of scintillator with wavelength shifting fiber readout into photodetectors. Figure 1 (a) shows the schematic layout of the calorimeters in CMS and shows the location of the HO scintillator layers. The front end electronics are placed inside the CMS detector, close to the scintillators. Figure 1(b) shows a photograph of the scintillators. Note the four wavelength shifting fibers per tile. The tile size creates a projective tower with the HB. Currently the photodetector used is the HPD but for performance and operational reasons it is desired to upgrade these with SIPMs. The CMS HCAL group has developed a drop-in replacement for the HPD using SIPMs. SIPMs are very suitable for this application because of several factors: The radiation levels are modest with a lifetime expected fluence of less than 5*10{sup 11} neutrons (E > 100 KeV) per cm{sup 2}. The energy flux into HO is small, the rate of larger energy depositions is low, and the required dynamic range is modest. The HO is in the return magnetic field of up to 2KG and the photodetector needs to operate in that environment. Finally, the available physical volume for the photodetectors is small.

43 PARTICLE ACCELERATORS↗

Electromagnetic and Hadron Calorimeters in the MIPP Experiment

The purpose of the MIPP experiment is to study the inclusive production of photons, pions, kaons, and nucleons in π, K, and p interactions on various targets using beams from the Main Injector at Fermilab. The function of the calorimeters is to measure the production of forward-going neutrons and photons. The electromagnetic calorimeter consists of 10 lead plates interspersed with proportional chambers. It was followed by the hadron calorimeter with 64 steel plates interspersed with scintillator. The data presented were collected with a variety of targets and beam momenta from 5 GeV/c to 120 GeV/c. The energy calibration of both calorimeters with electrons, pions, kaons, and protons is discussed. The resolution for electrons was found to be 0.27/sqrt(E), and for hadrons the resolution was 0.554/sqrt(E) with a constant term of 2.6%. The performance of the calorimeters was tested on a neutron sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The lead-glass electromagnetic calorimeters for the magnetic spectrometers in Hall C at Jefferson Lab

The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $\sigma/E \sim 6%/\sqrt E $, and pion/electron ($\pi/e$) separation of about 100:1 has been achieved in energy range 1 -- 5 GeV. Good agreement has been observed between the experimental and simulated energy resolutions, but simulations systematically exceed experimentally determined $\pi^-$ suppression factors by close to a factor of two. For the SHMS spectrometer presently under construction details on the design and accompanying GEANT4 simulation efforts are given. The anticipated performance of the new calorimeter is predicted over the full momentum range of the SHMS. Good electron/hadron separation is anticipated by combining the energy deposited in an initial (preshower) calorimeter layer with the total energy deposited in the calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and status of the Mu2e electromagnetic calorimeter

Here, the Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5×10 –17 after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF 2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D; studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrading the Fast Calorimeter Simulation in ATLAS

The tremendous need for simulated samples now and even more so in the future, encourages the development of fast simulation techniques. The Fast Calorimeter Simulation is a faster though less accurate alternative to the full calorimeter simulation with GEANT4. It is based on parametrizing the longitudunal and lateral energy deposits of single particles in the ATLAS calorimeter. Principal component analysis and machine learning techniques are used to improve the performance and decrease the memory need compared to the current version of the ATLAS Fast Calorimeter Simulation. The parametrizations are expanded to cover very high energies and very forward detector regions, to increase the applicability of the tool. A prototype of this upgraded Fast Calorimeter Simulation has been developed and first validations with single particles show substantial improvements over the previous version.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗