Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bypass Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Pressure Measurements in a Wire-Wrapped 61-Pin Hexagonal Fuel Bundle

To achieve longer-life liquid-metal fast reactor cores, designers are considering to increase the wall gap of the wire-wrapped hexagonal fuel bundles to account for volumetric void swelling and radiation creep. A new wire-wrapped hexagonal test bundle has been constructed, with a wall gap larger than prior experiments, and experimental pressure drop data have been generated under laminar, transition, and turbulent flow regimes (corresponding to Re of 250–19,000), to complement the existing database of small wall gap experimental bundles. The comparison of the experimental data set with the predictions of four existing correlations (Baxi and Dalle Donne, Cheng and Todreas detailed (CTD), Kirillov, and Rehme) showed general agreement between data and the selected correlations. However, the CTD correlation most accurately predicted the experimental trend and the transition between flow regimes. The analysis of the experimental data also revealed that the larger wall gap size caused a lower bundle pressure drop due to the increased bypass flow area.

42 ENGINEERING↗

Advanced Ultrasupercritical (AUSC) Materials Thick-Walled Cycling Header Development for ComTest-AUSC (Final Report)

Alstom Power Inc., a wholly owned subsidiary of the General Electric Company (GE) recently completed “Advanced Ultrasupercritical (AUSC) Materials Thick-Walled Cycling Header Development for ComTest-AUSC” under Award No. DE-FE0026183 for the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). This project developed a design for testing of a high temperature nickel-based superalloy thick-walled header to simulate cycling and flexible plant operation in new and existing plants. The objective was to simulate the expected thermal stresses of a new AUSC plant or a retrofit header in an existing plant to improve flexible dynamic operation while maintaining component integrity and overall power plant reliability. The high performance superalloy materials that enable higher operating temperatures and pressures can support future transformational power technologies including new AUSC plants at 4250-5000 psi, 730°C/760°C or will serve as a replacement component in a repowered or retrofit USC coal powered cycling plant at 3600 psi, 600°C. These alloys can also enable supercritical CO2 cycles, nuclear power, solar power and more efficient natural gas combined cycle units as targeted by the U.S. DOE/NETL Cross-Cutting Research Technology Program Plan. Recently developed advanced nickel alloys such as Inconel 740H (740H) and Haynes 282 (H282) have been successfully tested on a pilot scale for fireside corrosion using steam loop tubing at AUSC temperatures of 760°C in actual operating coal fired boiler. These high strength materials have been demonstrated their adequacy for use in other high temperature boiler components such as superheater tubes. Thick-walled superheater outlet headers which operate at high temperatures and pressure under severe cycling condition are considered as one of the most critical component in the AUSC coal fired boiler. Over the design life of a plant, these headers are exposed to the most severe fatigue and creep damage accumulation and need to be properly designed for the expected cycling in an AUSC plant with flexible operation. These materials need to demonstrate adequate design life of 20 to 30 years for creep and fatigue conditions. The following tasks were performed: 1. A conceptual design was developed of a thick-walled component representative of typical headers with several tube connections and proper flow rates (~100,000 lbs/hr) suitable for Phase II test at 760°C operation. This was based on a process analysis of expected full scale new and component retrofit designs for AUSC; 2. A multi-physics flow and heat transfer computational fluid dynamics (CFD) analysis of the component for proper layout of the header configuration, number and geometry (size) of tubes required for bypass flow, flow rates through the tubing, and sectional pressure drops was performed. Steam to header metal heat transfer film coefficients in the header section and the tubes during the two stages (half load and full load) of the cycling operation were evaluated and used in the stress analysis; 3. Detailed analytical evaluation of the thick-walled pipe and tube connections for mechanical integrity under cycling conditions was performed. This included transient thermal stress analysis and fatigue usage estimation including the tube-to-pipe weld geometries and weld materials; 4. A layout and design of the thick-walled test component was developed and instrumentation required for a test was identified; 5. Continuum Damage Mechanics (CDM) creep prediction models were extended to 740H and H282 and validated with public data on 740H and H282 for use in creep analysis. In addition, detailed creep analyses were performed separately for the design life of the conceptual AUSC superheater outlet header using these General Electric (GE) creep constitutive models. GE was the prime contractor for the project, which was directed by Principal Investigator Robert Schrecengost and Lead Scientist Dr. B. Reddy Ganta. Other collaborative participants in this project included GE Global Research, GE Boiler Engineering, and a Technical Consultant from EPRI.

01 COAL, LIGNITE, AND PEAT↗

Tandem Fan Applications in Advanced STOVL Fighter Configurations

The series/parallel tandem fan engine is evaluated for application in advanced STOVL supersonic fighter aircraft. Options in engine cycle parameters and design of the front fan flow diverter are examined for their effects on engine weight, dimensions, and other factors in integration of the engine with the aircraft. Operation of the engine in high-bypass flow mode during cruise and loiter flight is considered as a means of minimizizng fuel consumption. Engine thrust augmentation by burning in the front fan exhaust is discussed. Achievement of very sort takeoff with vectored thrust in briefly reviewed for tandem fan engine configurations with vectorable front fan nozzles. Examples are given of two aircraft configuration planforms, a delta-canard, and a forward-swept wing, to illustrate the major features. design considerations, and potential performance of the tandem fan installation in each. Full realization of the advantages of tandem fan propulsion are found to depend on careful selection of the aircraft configuration, since integration requirements can strongly influence the engine performance.

Zola, Charlse L.↗

Tandem fan applications in advanced STOVL fighter configurations

The series/parallel tandem fan engine is evaluated for application in advanced STOVL supersonic fighter aircraft. Options in engine cycle parameters and design of the front fan flow diverter are examined for their effects on engine weight, dimensions, and other factors in integration of the engine with the aircraft. Operation of the engine in high-bypass flow mode during cruise and loiter flight is considered as a means of minimizing fuel consumption. Engine thrust augmentation by burning in the front fan exhaust is discussed. Achievement of very short takeoff with vectored thrust is briefly reviewed for tandem fan engine configurations with vectorable front fan nozzles. Examples are given of two aircraft configuration planforms, a delta-canard, and a forward-swept wing, to illustrate the major features, design considerations, and potential performance of the tandem fan installation in each. Full realization of the advantages of tandem fan propulsion are found to depend on careful selection of the aircraft configuration, since integration requirements can strongly influence the engine performance. Previously announced in STAR as N84-24579

Zola, C. L.↗

Experimental Investigation of a Large-Scale Low-Boom Inlet Concept

A large-scale low-boom inlet concept was tested in the NASA Glenn Research Center 8- x 6- foot Supersonic Wind Tunnel. The purpose of this test was to assess inlet performance, stability and operability at various Mach numbers and angles of attack. During this effort, two models were tested: a dual stream inlet designed to mimic potential aircraft flight hardware integrating a high-flow bypass stream; and a single stream inlet designed to study a configuration with a zero-degree external cowl angle and to permit surface visualization of the vortex generator flow on the internal centerbody surface. During the course of the test, the low-boom inlet concept was demonstrated to have high recovery, excellent buzz margin, and high operability. This paper will provide an overview of the setup, show a brief comparison of the dual stream and single stream inlet results, and examine the dual stream inlet characteristics.

Hirt, Stefanie M.↗

Cost and Performance Baseline for Fossil Energy Plants Supplement: Sensitivity to CO 2 Capture Rate in Coal-Fired Power Plants

The cost and performance of various plants designed to meet a range of carbon dioxide (CO 2 ) emissions are evaluated in this report by varying the CO 2 capture rate. The base cases for these designs are the supercritical (SC) pulverized coal (PC) plant from the National Energy Technology Laboratory’s (NETL) report “Cost and Performance Baseline for Fossil Energy Plants, Volume 1a: Bituminous Coal (PC) and Natural Gas to Electricity, Revision 3” and the General Electric Energy (GEE) integrated gasification combined cycle (IGCC) plant in NETL’s report, “Cost and Performance Baseline for Fossil Energy Plants, Volume 1b: Bituminous Coal (IGCC) to Electricity, Revision 2 – Year Dollar Update.” The chosen SC PC plants were based on the Case B12B, differing only in the addition of a bypass flow path that allows for an appropriate portion of the flue gas stream exiting the desulfurization step to be directed towards the stack, which reduces the amount CO 2 captured in the Cansolv process. The chosen IGCC plants were based on the Case B5B, differing by bypassing (either partially or entirely) the water gas shift reactors and thereby reducing the amount of CO 2 captured in the Selexol process. The major components of the underlying CO 2 capture technology in the plants were preserved with minimal modifications to the overall processes. The SC PC cases include up-to-date cost and performance information from recent vendor quotes whereas the IGCC performance and cost are based upon the older quotes used for the Revision 2 report, with standard adjustments made to update the costs to 2011 dollars.

01 COAL, LIGNITE, AND PEAT↗

PIV Measurements of Chevrons on F400-Series Tactical Aircraft Nozzle Model

Reducing noise of tactical jet aircraft has taken on fresh urgency as core engine technologies allow higher specific-thrust engines and as society become more concerned for the health of its military workforce. Noise reduction on this application has lagged the commercial field as incentives for quieting military aircraft have not been as strong as in their civilian counterparts. And noise reduction strategies employed on civilian engines may not be directly applicable due to the differences in exhaust system architecture and mission. For instance, the noise reduction technology of chevrons, examined in this study, will need to be modified to take into account the special features of tactical aircraft nozzles. In practice, these nozzles have divergent slats that are tied to throttle position, and at take off the jet flow is highly overexpanded as the nozzle is optimized for cruise altitude rather than sea level. In simple oil flow visualization experiments conducted at the onset of the current test program flow barely stays attached at end of nozzle at takeoff conditions. This adds a new twist to the design of chevrons. Upon reaching the nozzle exit the flow shrinks inward radially, meaning that for a chevron to penetrate the flow it must extend much farther away from the baseline nozzle streamline. Another wrinkle is that with a variable divergence angle on the nozzle, the effective penetration will differ with throttle position and altitude. The final note of realism introduced in these experiments was to simulate the manner in which bypass flow is bled into the nozzle wall in real engines to cool the nozzle, which might cause very fat boundary layer at exit. These factors, along with several other issues specific to the application of chevrons to convergent-divergent nozzles have been explored with particle image velocimetry measurements and are presented in this paper.

Bridges, James↗

Directional Attenuation of Jet Noise With Eccentric Coannular Nozzle Investigated

Jet noise and flow field were measured to follow up on observations made by Professor D. Papamoschou of the University of California at Irvine (NASA Grant NAG3-2345). When a dual-stream coannular nozzle was arranged non-concentrically, noise was attenuated significantly on the side where the annulus was thicker. A similar observation was also made in reference 2. The practical significance is obvious. If the bypass flow of a jet exhaust in flight could be diverted to form a thicker layer underneath, then less noise would be heard by an observer on the ground. In view of the current emphasis on jet noise abatement, researchers felt that the effect deserved further attention. This prompted an experiment to confirm the phenomenon in a larger facility and to obtain flow-field data to advance understanding of the mechanism.

Zaman, Khairul B.↗

Hydropower and environmental flow management: System-level trade-offs at Glen Canyon Dam

The research focuses on the Colorado River Basin, specifically examining the Glen Canyon Dam (GCD) and its influence on surrounding aquatic ecosystems. This area is crucial due to its role in hydropower production and its impact on downstream environments, including the Grand Canyon National Park. This study explores the integration of environmental factors into hydro dispatch modeling at GCD to tackle ecological challenges posed by the invasive smallmouth bass (SMB). Utilizing the GTMax SL and SERM models, the research assesses the effects of SMB control experiments on hydropower generation, economic value, and grid stability. The study examines the financial and economic impacts of bypass flows designed to release colder water to prevent SMB spawning, which can significantly reduce hydropower output and increase costs. The research identifies that declining reservoir levels and rising water temperatures in Lake Powell have facilitated SMB spawning, posing a threat to native fish populations like the endangered humpback chub. The findings highlight the importance of adaptive management strategies to balance ecological preservation with hydropower generation amid long-term weather-related challenges. The study underscores the need for comprehensive assessments of flow options to prevent SMB establishment below GCD, considering the broader implications for sediment dynamics and ecological interactions.

Ecological impact assessment↗

Turbulent Flow Field Measurements of Separate Flow Round and Chevron Nozzles with Pylon Interaction Using Particle Image Velocimetry

Particle Image Velocimetry (PIV) measurements for six separate flow bypass ratio five nozzle configurations have recently been obtained in the NASA Langley Jet Noise Laboratory. The six configurations include a baseline configuration with round core and fan nozzles, an eight-chevron core nozzle at two different clocking positions, and repeats of these configurations with a pylon included. One run condition representative of takeoff was investigated for all cases with the core nozzle pressure ratio set to 1.56 and the total temperature to 828 K. The fan nozzle pressure ratio was set to 1.75 with a total temperature of 350 K, and the freestream Mach number was M = 0.28. The unsteady flow field measurements provided by PIV complement recent computational, acoustic, and mean flow field studies performed at NASA Langley for the same nozzle configurations and run condition. The PIV baseline configuration measurements show good agreement with mean flow field data as well as existing PIV data acquired at NASA Glenn. Nonetheless, the baseline configuration turbulence profile indicates an asymmetric flow field, despite careful attention to concentricity. The presence of the pylon increases the upper shear layer turbulence levels while simultaneously decreasing the turbulence levels in the lower shear layer. In addition, a slightly shorter potential core length is observed with the addition of the pylon. Finally, comparisons of computational results with PIV measurements are favorable for mean flow, slightly over-predicted for Reynolds shear stress, and underpredicted for Reynolds normal stress components.

Doty, Michael J.↗

Unstructured CFD and Noise Prediction Methods for Propulsion Airframe Aeroacoustics

Using unstructured mesh CFD methods for Propulsion Airframe Aeroacoustics (PAA) analysis has the distinct advantage of precise and fast computational mesh generation for complex propulsion and airframe integration arrangements that include engine inlet, exhaust nozzles, pylon, wing, flaps, and flap deployment mechanical parts. However, accurate solution values of shear layer velocity, temperature and turbulence are extremely important for evaluating the usually small noise differentials of potential applications to commercial transport aircraft propulsion integration. This paper describes a set of calibration computations for an isolated separate flow bypass ratio five engine nozzle model and the same nozzle system with a pylon. These configurations have measured data along with prior CFD solutions and noise predictions using a proven structured mesh method, which can be used for comparison to the unstructured mesh solutions obtained in this investigation. This numerical investigation utilized the TetrUSS system that includes a Navier-Stokes solver, the associated unstructured mesh generation tools, post-processing utilities, plus some recently added enhancements to the system. New features necessary for this study include the addition of two equation turbulence models to the USM3D code, an h-refinement utility to enhance mesh density in the shear mixing region, and a flow adaptive mesh redistribution method. In addition, a computational procedure was developed to optimize both solution accuracy and mesh economy. Noise predictions were completed using an unstructured mesh version of the JeT3D code.

Pao, S. Paul↗

Terminal Sinking Velocity for Waste Packages Falling in a Deep Borehole - 17063

This evaluation of terminal velocity for a waste package sinking in a deep borehole filled with emplacement fluid was done to support concept development for the Deep Borehole Field Test (DBFT). The DBFT objective is to evaluate the safety and feasibility of the deep borehole disposal (DBD) concept for certain radioactive wastes. The DBD concept calls for emplacing waste packages in the lower 2 km of a borehole drilled into crystalline basement rock to a depth of 5 km. Previous studies identified that accidentally dropping one or more waste packages during emplacement could be an important risk, particularly if a waste package is breached. This study evaluated the range of terminal sinking velocity, which can be used to design waste packages and impact limiters to ensure that breach does not occur. Based on an analytical model of a sinking container, a highly turbulent flow is expected to develop in the emplacement fluid. Turbulence is a complex three-dimensional phenomenon and the applicability of analytical models is limited. To backstop the analytical model and to extend predictions to other package dimensions and fluid properties, numerical simulation was performed using the ANSYS Fluent computational fluid dynamics code. Terminal velocity was calculated for downhole temperatures up to 1200 C, and three emplacement fluids (water, NaCl brine, and NaBr brine). Simulation results confirmed that flow around the sinking container is highly turbulent (Reynolds number 5.6 x 10{sup 4} to 7.3 x 10{sup 5}). Turbulence increases with temperature and decreases with density. Calculated terminal velocity ranges from 1.95 (200 C) to 2.13 m/s (1200 C) in water; 1.61 (200 C) to 1.79 m/s (1200 C) in NaCl; and 1.30 (200 C) to 1.46 m/s (1200 C) in NaBr. Terminal velocity is inversely related to fluid density, and the temperature effect on density appears to have a stronger effect on terminal velocity than the temperature effect on viscosity. The foregoing results are for non-perforated casing, but in practice the casing may be perforated to prepare for cementing, and to allow relief of fluid pressure from thermal expansion after emplacement of heat generating waste, and after final borehole closure. To represent the effect from perforations, the analytical solution was modified to include bypass flow through perforations and in the annulus. A workable perforation scheme is identified, consistent with borehole construction and closure requirements, using 2-cm and 5-cm diameter perforations. This scheme is estimated to limit the terminal velocity to 3 m/s, for reference waste packages falling in water at 400 C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Active Magnetic Regenerative Liquefier

This final report for the DOE Project entitled Active Magnetic Regenerative Liquefier (AMRL) funded under Grant DE-FG36-08GO18064 to Heracles Energy Corporation d.b.a. Prometheus Energy (Heracles/Prometheus) describes an active magnetic regenerative refrigerator (AMRR) prototype designed and built during the period from July 2008 through May 2011. The primary goal of this project was to make significant technical advances toward highly efficient liquefaction of hydrogen. Conventional hydrogen liquefiers at any scale have a maximum FOM of ~0.35 due primarily to the intrinsic difficulty of rapid, efficient compression of either hydrogen or helium working gases. Numerical simulation modeling of high performance AMRL designs indicates certain designs have promise to increase thermodynamic efficiency from a FOM of ~0.35 toward ~0.5 to ~0.6. The technical approach was the use of solid magnetic working refrigerants cycled in and out of high magnetic fields to build an efficient active regenerative magnetic refrigeration module providing cooling power for AMRL. A single-stage reciprocating AMRR with a design temperature span from ~290 K to ~120 K was built and tested with dual magnetic regenerators moving in and out of the conductively-cooled superconducting magnet subsystem. The heat transfer fluid (helium) was coupled to the process stream (refrigeration/liquefaction load) via high performance heat exchangers. In order to maximize AMRR efficiency a helium bypass loop with adjustable flow was incorporated in the design because the thermal mass of magnetic refrigerants is higher in low magnetic field than in high magnetic field. Heracles/Prometheus designed experiments to measure AMRR performance under a variety of different operational parameters such as cycle frequency, magnetic field strength, heat transfer fluid flow rate, amount of bypass flow of the heat transfer fluid while measuring work input, temperature span, cooling capability as a function of cold temperature as a function of the amount of bypass flow of the heat transfer fluid. The operational AMRR prototype can be used to answer key questions such as the best recipe for multiple layers of different magnetic refrigerants in one or more integrated regenerators with varying amounts of bypass flow of the heat transfer fluid. Layered regenerators are necessary to span the AMRR range from 290 K to 120K. Our AMRR performance simulation model predicts that ~10-15 % of bypass flow should significantly improve the thermodynamic performance. Initial results obtained with regenerators made of gadolinium spheres were very encouraging; a temperature span of ~ 50 K (between 295K and 245 K) across both regenerators was achieved with zero bypass flow of the heat transfer fluid and with the magnetic field strength of ~4 T.

42 ENGINEERING↗

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE↗

Improving the modeling of near-wall interphase heat transfer in porous media models of Pebble Bed Reactors

Here, this work aims to improve capabilities for modeling localized effects in porous media models of Pebble Bed Reactors. The wall-channeling effect is the primary local phenomenon of interest in a PBR, where the presence of the reflector wall disrupts the pebble packing, causing the pebbles near the wall to pack less efficiently and creating large void regions. Accurate modeling of the near-wall region is important as it will affect core bypass flow and temperature predictions. Porous media models are commonly used for design scoping and plant-level simulations of PBRs. Although these models have some capabilities to model the near-wall region, the correlations that are available in porous media codes are often inaccurate when a multi-region model is used to discretize the near-wall region. This work employs a high-to-low analysis to study the accuracy of available interphase heat transfer closures. NekRS, a spectral element computational fluid dynamics code, is used to perform Large Eddy Simulations. These LES simulation results are compared to porous media model results from the Pronghorn porous media code. The friction term of the KTA drag closure is first improved, reducing the error in the prediction of the near-wall velocity from over 50% to less than 5%. This is combined with improvements to the form term from previous works to produce a drag closure that is capable of accurately modeling the wall-channeling effect across a variety of flow conditions. The Nusselt number predictions of several heat transfer correlations are compared to the high-fidelity results where it is found that the KTA heat transfer correlation is capable of accurately predicting the local Nusselt numbers that were determined in the high-fidelity simulation. Comparison of the radial solid temperature profiles, however, reveal discrepancies between NekRS and Pronghorn. It is discovered that the implementation of the interphase heat transfer coefficient that exists in many current porous media codes is not valid when local porosities are modeled. Instead, it is suggested that the interphase heat transfer coefficient should be dependent on the local porosity, the Nusselt number, and the local solid surface-to-volume ratio. Implementation of this change produces improvement in the agreement between the results obtained by NekRS and Pronghorn while using the KTA heat transfer correlation.

interphase heat transfer↗