Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bragg spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Momentum-exchange interactions in a Bragg atom interferometer suppress Doppler dephasing

Large ensembles of laser-cooled atoms interacting through infinite-range photon-mediated interactions are powerful platforms for quantum simulation and sensing. Here we realize momentum-exchange interactions in which pairs of atoms exchange their momentum states by collective emission and absorption of photons from a common cavity mode, a process equivalent to a spin-exchange or XX collective Heisenberg interaction. The momentum-exchange interaction leads to an observed all-to-all Ising-like interaction in a matter-wave interferometer. A many-body energy gap also emerges, effectively binding interferometer matter-wave packets together to suppress Doppler dephasing in analogy to Mössbauer spectroscopy. The tunable momentum-exchange interaction expands the capabilities of quantum interaction–enhanced matter-wave interferometry and may enable the realization of exotic behaviors, including simulations of superconductors and dynamical gauge fields.

Science & Technology - Other Topics↗

X-ray Absorption Spectroscopy of Dilute Metalloenzymes at X-ray Free-Electron Lasers in a Shot-by-Shot Mode

X-ray absorption spectroscopy (XAS) of 3d transition metals provides important electronic structure information for many fields. However, X-ray-induced radiation damage under physiological temperature has prevented using this method to study dilute aqueous systems, such as metalloenzymes, as the catalytic reaction proceeds. Here we present a new approach to enable operando XAS of dilute biological samples and demonstrate its feasibility with K-edge XAS spectra from the Mn cluster in photosystem II and the Fe–S centers in photosystem I. This approach combines highly efficient sample delivery strategies and a robust signal normalization method with high-transmission Bragg diffraction-based spectrometers at X-ray free-electron lasers (XFELs) in a damage-free, shot-by-shot mode. These photon-out spectrometers have been optimized for discriminating the metal Mn/Fe Kα fluorescence signals from the overwhelming scattering background present on currently available detectors for XFELs that lack suitable energy discrimination. We quantify the enhanced performance metrics of the spectrometer and discuss its potential applications for acquiring time-resolved XAS spectra of biological samples during their reactions at XFELs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Topography of bent crystals with microradian resolution in one dimension

Optimum performance in x-ray imaging and spectroscopy of plasmas with bent crystals is achievable only when the crystal reflects the x rays theoretically perfectly across its entire surface. However, typical thin quartz (101̄1) crystal samples kept flat by direct attachment to a flat substrate reflect 8 keV x rays differently across their surface, on a scale comparable to the ideal rocking curve. Additional processing improves the uniformity. Irradiation of flat crystals with collimated, monochromatic x rays in rocking curve topography shows such problems directly, with microradian resolution. Nonuniform x-ray reflection is more difficult to document for strongly bent crystals because, then, monochromatic, collimated x rays satisfy the Bragg condition only along a narrow stripe that may be too narrow to resolve with the available cameras. However, it can be resolved with a knife edge that moves through the reflected x rays with the necessary spatial precision as demonstrated here for a bent silicon crystal. This shows qualitatively similar imperfections in the reflection as flat quartz and as the bent quartz analyzers reported on previously with lower resolution.

Pereira, N. R. (ORCID:0000000290569596)↗

Polarization splitting with cubic crystals evaluated with synchrotron radiation

X-ray polarization-splitting crystals separate incident x rays into two components with perpendicular polarization by Bragg reflections at 45° from paired sets of internal planes. Here, the polarization-splitting properties of a germanium crystal are verified using incompletely polarized synchrotron radiation. Further, cleaner data would have come from a beam with a higher degree of polarization, which is achievable with small changes in the experimental geometry.

47 OTHER INSTRUMENTATION↗

X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers

X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9–4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. Here, in this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα 1 and Kα 2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

High resolution x-ray emission spectrometer for multiple hard x-ray emission lines: Demonstration for Cu Kα and Kβ emissions

In this work, we present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES). The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal holders that can be easily exchanged, as well as movable alignment eyelets that give flexibility in Bragg angle selection. Designed for ease of manufacture, all the components, except for the apertures, can be 3D printed and readily assembled. We describe its implementation in measurements of resonant and non-resonant Cu Kα and Kβ x-ray emission and report the theoretical and measured energy resolution and collected solid angle of the emission.

3D printing↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗

Enhancing Organic Semiconductor Molecular Packing Using Perovskite Interfaces to Improve Singlet Fission

Singlet fission, a process by which one singlet exciton is converted into two lower energy triplet excitons, is sensitive to the degree of electronic coupling within a molecular packing structure. Variations in molecular packing can be detrimental to triplet formation and triplet–triplet separation, ultimately affecting the harvesting of triplets for electricity in organic photovoltaic devices. Here, six phase-pure molecular packing structures of 6,13-bis(triisopropylsilylethynyl)pentacene (TIPS-pentacene) with varying optoelectronic properties are isolated using 2D lead halide perovskites as tunable, crystalline surfaces for crystallization. Transient absorption spectroscopy reveals that while triplet formation is fast (<100 fs) regardless of template structure, the increased ordering in perovskite-templated samples speeds up triplet–triplet separation and recombination, providing evidence that the benefits of phase-purity offset minor variations in molecular packing. Molecular dynamics modeling of the interface reveals that perovskite-templating allows for closer packing of TIPS-pentacene molecules for all perovskite templates. With an extensive number of organic molecule-perovskite pairings, this work provides a methodology to use ordered, periodic surfaces to elucidate structure–property relationships of small organic molecules in order to adjust structural or optoelectronic responses, such as molecular packing and singlet fission.

36 MATERIALS SCIENCE↗

Atomic-Site-Specific Surface Valence-Band Structure from X-Ray Standing-Wave Excited Photoemission

X-ray standing-wave (XSW) excited photoelectron emission was used to measure the site-specific valence band (VB) for ½ monolayer (ML) Pt grown on a SrTiO 3 (001) surface. The XSW induced modulations in the core level (CL), and VB photoemission from the surface and substrate atoms were monitored for three ℎ⁡kl substrate Bragg reflections. The XSW CL analysis shows the Pt to have a face-centered-cubic-like cube-on-cube epitaxy with the substrate. The XSW VB information compares well to a density functional theory calculated projected density of states from the surface and substrate atoms. Altogether, this Letter represents a novel method for determining the contribution to the density of states by valence electrons from specific atomic surface sites.

74 ATOMIC AND MOLECULAR PHYSICS↗

2-Aminoanthracene Crystallization in Its Compatible Polystyrene Block: RAFT Synthesis and Enhanced Charge Retention in Pentacene Transistor Gate Dielectrics

We synthesized polystyrene-block-polyanthrylaminomethylstyrene (PS-b-PAAS) via RAFT reaction and side chain modification where the PAAS block is 50%. By blending 2-aminoanthracene (2AA) with PS-b-PAAS, the co-aggregation behavior of the PAAS block and 2AA within the thin film was observed by optical microscopy (OM) and x-ray diffraction. At 5 and 10 wt% of 2AA within the thin film, OM results showed a clear morphological difference between PS matrix and PS-b-PAAS matrix. Differences in the 2AA excited state lifetime in these matrices were also established using transient absorption spectroscopy (TAS). Blends were used as gate dielectrics in pentacene transistors. We compared characteristic voltage (Vc, an indicator of threshold voltage) before and after charging of PS-b-PAAS blended with unsubstituted PS and both polymers individually blended with 2AA. For blended PS-b-PAAS and PS, as the concentration of PS-b-PAAS increases, the decreased Vc especially with negative charging of the pentacene indicated a larger concentration of charge carriers induced by the dielectric film. The charging experiments also revealed that the unique structure formed by the 2AA/PS-b-PAAS blend significantly affected the charge storage capability of the organic field-effect transistors (OFET). Furthermore, this work demonstrates the novel co-aggregation structure in the dielectrics, and furthermore its impact on charge storage capability in pentacene OFETs.

36 MATERIALS SCIENCE↗

Ultrafast light-induced shear strain probed by time-resolved x-ray diffraction: Multiferroic BiFeO 3 as a case study

Enabling the light control of complex systems on ultrashort timescales gives rise to rich physics with promising applications. Although crucial, the quantitative determination of both the longitudinal and the shear photoinduced strains still remains challenging. Here, by scrutinizing asymmetric Bragg peaks pairs (±h01) in BiFeO 3 using picosecond time-resolved x-ray diffraction experiments, we simultaneously determine the longitudinal and shear strains. Importantly, we reveal a difference in the dynamical response of the longitudinal strain with respect to the shear one due to an interplay of quasilongitudinal and quasitransverse acoustic modes, well reproduced by our model. Lastly, we show that the relative amplitude of those strains can be explained only if both thermal and nonthermal processes contribute to the acoustic phonon photogeneration process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Streaked Sub-ps-resolution X-ray Line Shapes and Implications for Solid-density Plasma Dynamics

A high-resolution x-ray spectrometer was coupled with an ultrafast x-ray streak camera to produce time-resolved line shape spectra measured from hot, solid-density plasmas. A Bragg crystal was placed near a laser-produced plasma to maximize throughput; alignment tolerances were established by raytracing. The streak camera produced single-shot time-resolved spectra, heavily sloped due to photon time-of-flight differences, with sufficient reproducibility to accumulate photon statistics. The images are time-calibrated by the slope of streaked spectra and dewarped to generate spectra emitted at different times defined at the source. The streaked spectra demonstrate the evolution of spectral shoulders and other features on ps timescales, showing the feasibility of plasma parameter measurements on the rapid timescales necessary to study high-energy-density plasmas.

High-energy-density plasmas↗

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION↗

Inelastic neutron scattering study of the anisotropic S = 1 spin chain [ Ni ( HF 2 ) ( 3 – Clpyridine ) 4 ] BF 4

[Ni(HF 2 )(3–Clpyridine) 4 ]BF 4 (NBCT) is a one-dimensional, S = 1 spin chain material that shows no magnetic neutron Bragg peaks down to temperatures of 0.1 K. Previous work identified NBCT as being in the Haldane phase and near a quantum phase transition as a function of D/J to the large-D quantum paramagnet phase (QPM), where D is the axial single-ion anisotropy and J is the intrachain superexchange. Herein, inelastic neutron scattering results are presented on partially deuterated, 11B-enriched NBCT polycrystalline samples in zero magnetic field and down to temperatures of 0.3 K. Comparison to density matrix renormalization group calculations yields D/J = 1.51 and a significant rhombic single-ion anisotropy E (E/D ≈ 0.03, E/J ≈ 0.05). Here, these D, J, and E values place NBCT in the large-D QPM phase but precipitously near a quantum phase transition to a long-range ordered phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-temperature state in strontium titanate microcrystals using in situ multireflection Bragg coherent x-ray diffraction imaging

Strontium titanate is a classic quantum paraelectric oxide material that has been widely studied in bulk and thin films. It exhibits a well-known cubic-to-tetragonal antiferrodistortive phase transition at 105 K, characterized by the rotation of oxygen octahedra. A possible second phase transition at lower temperature is suppressed by quantum fluctuations, preventing the onset of ferroelectric order. However, recent studies have shown that ferroelectric order can be established at low temperatures by inducing strain and other means. Here, we used in situ multireflection Bragg coherent x-ray diffraction imaging to measure the strain and rotation tensors for two strontium titanate microcrystals at low temperature. We observe strains induced by dislocations and inclusion-like impurities in the microcrystals. Based on radial magnitude plots, these strains increase in magnitude and spread as the temperature decreases. Pearson's correlation heat maps show a structural transition at 50 K, which could possibly be the formation of a low-temperature ferroelectric phase in the presence of strain. We do not observe any change in local strains associated with the tetragonal phase transition at 105 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlated Anion Disorder in Heteroanionic Cubic TiOF 2

Resolving anion configurations in heteroanionic materials is crucial for understanding and controlling their properties. For anion-disordered oxyfluorides, conventional Bragg diffraction cannot fully resolve the anionic structure, necessitating alternative structure determination methods. We have investigated the anionic structure of anion-disordered cubic (ReO 3 -type) TiOF 2 using X-ray pair distribution function (PDF), 19 F MAS NMR analysis, density functional theory (DFT), cluster expansion modeling, and genetic-algorithm structure prediction. Our computational data predict short-range anion ordering in TiOF 2 , characterized by predominant cis-[O 2 F 4 ] titanium coordination, resulting in correlated anion disorder at longer ranges. To validate our predictions, we generated partially disordered supercells using genetic-algorithm structure prediction and computed simulated X-ray PDF data and 19 F MAS NMR spectra, which we compared directly to experimental data. To construct our simulated 19 F NMR spectra, we derived new transformation functions for mapping calculated magnetic shieldings to predicted magnetic chemical shifts in titanium (oxy)fluorides, obtained by fitting DFT-calculated magnetic shieldings to previously published experimental chemical shift data for TiF 4 . We find good agreement between our simulated and experimental data, which supports our computationally predicted structural model and demonstrates the effectiveness of complementary experimental and computational techniques in resolving anionic structure in anion-disordered oxyfluorides. From additional DFT calculations, we predict that increasing anion disorder makes lithium intercalation more favorable by, on average, up to 2 eV, highlighting the significant effect of variations in short-range order on the intercalation properties of anion-disordered materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗