Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bone imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Deletion of Cdkn1a in Mice Rescues Reduced Osteogenesis in Microgravity and Increases Coupled Osteoclastic Bone Degenerative Activity and Bone Loss

Elevated Cdkn1a/p21 levels in mouse bone during spaceflight have led us to hypothesize that this cell cycle inhibitor could regulate osteogenesis in response to mechanical unloading in microgravity. Cdkn1a interacts with cyclins CDK1/2/4,6 during G1 and S phases, and suppression of its expression by mechanical stretch enhances proliferation and mineralization in osteoblastic cell cultures. To test this hypothesis in a whole-organism model, we used C57BL/J6 WT/Cdkn1a-null mice in the NASA RR-10, 30-day ISS microgravity experiment. To quantify active mineralization in microgravity mice were injected with Calcein seven and two days before euthanasia on-orbit, followed by high-resolution confocal imaging of optically cleared femoral endosteal surfaces. To quantify cortical and cancellous bone parameters we conducted microCT analyses of the femur and tibia. Confocal imaging revealed a population of mineralizing calcein-positive single osteoblasts, and multicellular surfaces of mineralization by osteocytes in lacunae. The Cdkn1a-null genotype shows a greater ratio of early-osteoblasts to late-osteocytes and reduced mineralization versus WT. Additionally, in microgravity WT bones have a large (80%) decrease in active mineralization, but remarkably Cdkn1a deletion fully rescued mineralized surface loss. MicroCT shows trends for moderate spaceflight bone loss in WT femurs, and significant losses in the tibia, while Cdkn1a-null femurs showed much larger significant tissue losses, including 25% thinner trabeculae (p < 0.01),40% thinner cortical bone (p < 0.005), and 10% lower percent cortical bone area (p < 0.05). These results indicate that endogenous bone Cdkn1a plays a key role in mechanosensitive downregulation of osteoprecursor proliferation and promotes osteocytic differentiation. In microgravity however, while Cdkn1a deletion rescues mineralization, bone loss quantified by microCT is greatly increased, likely due to the molecular coupling of osteogenesis and osteoclastogenesis. This molecular mechanism opens the possibility for potential pharmacological approaches to mitigate bone loss in space simultaneously targeting Cdkn1a and osteoclast inhibition.

Eduardo A.C. Almeida↗

Experiment K-6-01. Distribution and biochemistry of mineral and matrix in the femurs of rats

Previous analyses of the composition of mineral and matrix in the bone of young rats following space flight has revealed deficits in calcium, phosphorus, and osteocalcin, a non-collagenous protein, without an associated decrease in collagen. To characterize the location and nature of this mineralization defect in a weight bearing long bone, the femur, researchers attempted to relate the spatial distribution of mineral in situ in the proximal, central and distal thirds of the femoral diaphysis to the biochemical composition of bone from the same area. Biochemical analyses revealed lower concentrations of calcium, phosphorus and osteocalcin but not collagen only in the central third of the diaphysis of the flight animals (F) compared to synchronous controls (S). Collagen concentration was reduced only in the proximal third of the diaphysis, where all 3 crosslinks, expressed as nM/mol collagen were higher in F than S. A new technique, x ray microtomography, with a resolution of 26 microns, was used to obtain semi-quantitative data on mineral distribution in reconstructed sections of wet whole bone. To improve the resolution of the mineral density distribution, images of the surfaces of cut sections were analyzed by backscattered electrons in a scanning electron microscope (BSE). There was good agreement between the results of the two stereochemical techniques which revealed distinct patterns of mineralization in transverse and longitudinal directions of the diaphysis. The novel methodology developed for this flight experiment shows considerable promise in elucidating the biochemical nature of what appear to be regional alterations in the mineralization of long bones of animals exposed to spaceflight.

Arnaud, S.↗

A new programming metaphor for image processing procedures

Most image processing systems, besides an Application Program Interface (API) which lets users write their own image processing programs, also feature a higher level of programmability. Traditionally, this is a command or macro language, which can be used to build large procedures (scripts) out of simple programs or commands. This approach, a legacy of the teletypewriter has serious drawbacks. A command language is clumsy when (and if! it attempts to utilize the capabilities of a multitasking or multiprocessor environment, it is but adequate for real-time data acquisition and processing, it has a fairly steep learning curve, and the user interface is very inefficient,. especially when compared to a graphical user interface (GUI) that systems running under Xll or Windows should otherwise be able to provide. ll these difficulties stem from one basic problem: a command language is not a natural metaphor for an image processing procedure. A more natural metaphor - an image processing factory is described in detail. A factory is a set of programs (applications) that execute separate operations on images, connected by pipes that carry data (images and parameters) between them. The programs function concurrently, processing images as they arrive along pipes, and querying the user for whatever other input they need. From the user's point of view, programming (constructing) factories is a lot like playing with LEGO blocks - much more intuitive than writing scripts. Focus is on some of the difficulties of implementing factory support, most notably the design of an appropriate API. It also shows that factories retain all the functionality of a command language (including loops and conditional branches), while suffering from none of the drawbacks outlined above. Other benefits of factory programming include self-tuning factories and the process of encapsulation, which lets a factory take the shape of a standard application both from the system and the user's point of view, and thus be used as a component of other factories. A bare-bones prototype of factory programming was implemented under the PcIPS image processing system, and a complete version (on a multitasking platform) is under development.

Smirnov, O. M.↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗

The Effect of Spaceflight on Bone Cell Cultures

Understanding the response of bone to mechanical loading (unloading) is extremely important in defining the means of adaptation of the body to a variety of environmental conditions such as during heightened physical activity or in extended explorations of space or the sea floor. The mechanisms of the adaptive response of bone are not well defined, but undoubtedly they involve changes occurring at the cellular level of bone structure. This proposal has intended to examine the hypothesis that the loading (unloading) response of bone is mediated by specific cells through modifications of their activity cytoskeletal elements, and/or elaboration of their extracellular matrices. For this purpose, this laboratory has utilized the results of a number of previous studies defining molecular biological, biochemical, morphological, and ultrastructural events of the reproducible mineralization of a primary bone cell (osteoblast) culture system under normal loading (1G gravity level). These data and the culture system then were examined following the use of the cultures in two NASA shuttle flights, STS-59 and STS-63. The cells collected from each of the flights were compared to respective synchronous ground (1G) control cells examined as the flight samples were simultaneously analyzed and to other control cells maintained at 1G until the time of shuttle launch, at which point they were terminated and studied (defined as basal cells). Each of the cell cultures was assayed in terms of metabolic markers- gene expression; synthesis and secretion of collagen and non-collagenous proteins, including certain cytoskeletal components; assembly of collagen into macrostructural arrays- formation of mineral; and interaction of collagen and mineral crystals during calcification of the cultures. The work has utilized a combination of biochemical techniques (radiolabeling, electrophoresis, fluorography, Western and Northern Blotting, and light microscopic immunofluorescence) and structural methods (conventional and high voltage electron microscopy, inununocytochemistry, stereomicroscopy, and 3D image reconstruction). The studies have provided new knowledge of aspects of bone cell development and structural regulation, extracellular matrix assembly, and mineralization during spaceflight and under normal gravity. The information has contributed to insights into the means in general by which cells respond and adapt to different conditions of gravity (loading). The data may as well have suggested an underlying basis for the observed loss of bone by vertebrates, including man, in microgravity; and these scientific results may have implications for understanding bone loss following fracture healing and extended periods of inactivity such as during long-term bedrest.

Landis, William J.↗

Characterization of microgravity effects on bone structure and strength using fractal analysis

The effect of micro-gravity on the musculoskeletal system has been well studied. Significant changes in bone and muscle have been shown after long term space flight. Similar changes have been demonstrated due to bed rest. Bone demineralization is particularly profound in weight bearing bones. Much of the current techniques to monitor bone condition use bone mass measurements. However, bone mass measurements are not reliable to distinguish Osteoporotic and Normal subjects. It has been shown that the overlap between normals and osteoporosis is found for all of the bone mass measurement technologies: single and dual photon absorptiometry, quantitative computed tomography and direct measurement of bone area/volume on biopsy as well as radiogrammetry. A similar discordance is noted in the fact that it has not been regularly possible to find the expected correlation between severity of osteoporosis and degree of bone loss. Structural parameters such as trabecular connectivity have been proposed as features for assessing bone conditions. In this report, we use fractal analysis to characterize bone structure. We show that the fractal dimension computed with MRI images and X-Ray images of the patella are the same. Preliminary experimental results show that the fractal dimension computed from MRI images of vertebrae of human subjects before bedrest is higher than during bedrest.

Acharya, Raj S.↗

Determination of Small Animal Long Bone Properties Using Densitometry

Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased precision and repeatability. Standard deviations for the femur are consistent with those of the phantom. We conclude that in conjunction with digital image enhancement, densitometry scans are suitable for non-destructive determination of areal properties of small animal bones of comparable size to our phantom, allowing prediction of Imax and Imin within 2.5% and Theta within a fraction of a degree. This method represents a considerable extension of current methods of analyzing bone tissue distribution in small animal bones.

Breit, Gregory A.↗

Ultrasound Imaging of Spine: State of the Art and Utility for Space Flight

Introduction: Ultrasound imaging (sonography) has been increasingly used for both primary diagnosis and monitoring of musculoskeletal injury, including fractures. In certain injuries, sonography has been shown to equal or surpass Magnetic Resonance Imaging in accuracy. Long-term exposure to reduced gravity may be expected to cause physiological and anatomical changes of the musculoskeletal system, which are not fully described or understood. In a limited-resource environment like space flight, sonography will likely remain the only imaging modality; therefore, further attention to its potential is warranted, including its ability to image anatomical deviations as well as irregularities of vertebrae and the spinal column. Methods: A thorough review of literature was conducted on the subject. A multipurpose ultrasound system was used to identify specific vertebrae, intervertebral disks, and other structures of the cervical spine in healthy volunteers, selected to represent various age, gender, and Body Mass Index (BMI) groups. Sonographic views were sought that would parallel radiographic views and signs used in the diagnosis of cervical spine injuries. Results: While using widely accepted radiographic signs of cervical spine injury, this sonographic protocol development effort resulted in successful identification of scanning planes and imaging protocols that could serve as alternatives for radiography. Some of these views are also applicable to diagnosing degenerative disk and bone disease, and other non-traumatic spine pathology. Strong, preliminary correlation has been demonstrated in a number of clinical cases between sonography and other imaging modalities. Conclusion: In the absence of radiography, sonography can be used to diagnose or rule out certain common types of cervical spine conditions including injury. Clinical validation of the findings appears to be realistic and would facilitate establishment of new sonographic protocols for special environments with lacking radiographic capability, such as human space flight.

Sargsyan, Ashot E.↗

Biomedical technology transfer. Applications of NASA science and technology

Ongoing projects described address: (1) intracranial pressure monitoring; (2) versatile portable speech prosthesis; (3) cardiovascular magnetic measurements; (4) improved EMG biotelemetry for pediatrics; (5) ultrasonic kidney stone disintegration; (6) pediatric roentgen densitometry; (7) X-ray spatial frequency multiplexing; (8) mechanical impedance determination of bone strength; (9) visual-to-tactile mobility aid for the blind; (10) Purkinje image eyetracker and stabilized photocoalqulator; (11) neurological applications of NASA-SRI eyetracker; (12) ICU synthesized speech alarm; (13) NANOPHOR: microelectrophoresis instrument; (14) WRISTCOM: tactile communication system for the deaf-blind; (15) medical applications of NASA liquid-circulating garments; and (16) hip prosthesis with biotelemetry. Potential transfer projects include a person-portable versatile speech prosthesis, a critical care transport sytem, a clinical information system for cardiology, a programmable biofeedback orthosis for scoliosis a pediatric long-bone reconstruction, and spinal immobilization apparatus.

Harrison, D. C.↗

Time course of epiphyseal growth plate fusion in rat tibiae

Although the rat is the most common animal model used in studying osteoporosis, it is often used inappropriately. Osteoporosis is a disease that most commonly occurs in humans long after growth plate fusion with the associated cessation of longitudinal bone growth, but there has been a question as to when or to what extent the rat growth plate fuses. To investigate this question, we used microcomputed X-ray tomography, at voxel resolutions ranging from (5.7 micro m)(3) to (11 micro m)(3), to image the proximal epiphyseal growth plates of both male (n = 19) and female (n = 15) rat tibiae, ranging in age from 2 to 25 months. The three-dimensional images were used to evaluate fusion of the epiphyseal growth plate by quantitating the amount of cancellous bone that has bridged across the growth plate. The results suggest that the time course of fusion of the epiphyseal growth plate follows a sigmoidal pattern, with 10% of the maximum number of bridges having formed by 3.9 months in the male tibiae and 5.8 months in the female tibiae, 50% of the maximum number of bridges having formed by 5.6 months in the male tibiae and 5.9 months in the female tibiae, and 90% of the total maximum of bridges have formed by 7.4 months for the males and 6.5 months for the females. The total volume of bridges per tibia at the age at which the maximum number of bridges per tibia has first formed is 0.99 mm(3)/tibia for the males and 0.40 mm(3)/tibia for the females. After the maximum number of bridges (-290 for females, -360 for males) have formed the total volume of bridges per tibia continues to increase for an additional 7.0 months in the males and 17.0 months for the females until they reach maximum values (-1.5 mm(3)/tibia for the males and -2.2 mm(3)/tibia for the females).

NASA Discipline Cell Biology↗

Independent Evidence for the Preservation of Endogenous Bone Biochemistry in a Specimen of Tyrannosaurus rex

Biomolecules preserved in deep time have potential to shed light on major evolutionary questions, driving the search for new and more rigorous methods to detect them. Despite the increasing body of evidence from a wide variety of new, high resolution/high sensitivity analytical techniques, this research is commonly met with skepticism, as the long standing dogma persists that such preservation in very deep time (>1 Ma) is unlikely. The Late Cretaceous dinosaur Tyrannosaurus rex (MOR 1125) has been shown, through multiple biochemical studies, to preserve original bone chemistry. Here, we provide additional, independent support that deep time bimolecular preservation is possible. We use synchrotron X-ray fluorescence imaging (XRF) and X-ray absorption spectroscopy (XAS) to investigate a section from the femur of this dinosaur, and demonstrate preservation of elements (S, Ca, and Zn) associated with bone remodeling and redeposition. We then compare these data to the bone of an extant dinosaur (bird), as well as a second non-avian dinosaur, Tenontosaurus tilletti (OMNH 34784) that did not preserve any sign of original biochemistry. Our data indicate that MOR 1125 bone cortices have similar bone elemental distributions to that of an extant bird, which supports preservation of original endogenous chemistry in this specimen.

59 BASIC BIOLOGICAL SCIENCES↗

Extracellular vesicles of calcifying turkey leg tendon characterized by immunocytochemistry and high voltage electron microscopic tomography and 3-D graphic image reconstruction

To gain insight into the structure and possible function of extracellular vesicles in certain calcifying vertebrate tissues, normally mineralizing leg tendons from the domestic turkey, Meleagris gallopavo, have been studied in two separate investigations, one concerning the electron microscopic immunolocalization of the 66 kDa phosphoprotein, osteopontin, and the other detailing the organization and distribution of mineral crystals associated with the vesicles as determined by high voltage microscopic tomography and 3-D graphic image reconstruction. Immunolabeling shows that osteopontin is related to extracellular vesicles of the tendon in the sense that its initial presence appears coincident with the development of mineral associated with the vesicle loci. By high voltage electron microscopy and 3-D imaging techniques, mineral crystals are found to consist of small irregularly shaped particles somewhat randomly oriented throughout individual vesicles sites. Their appearance is different from that found for the mineral observed within calcifying tendon collagen, and their 3-D disposition is not regularly ordered. Possible spatial and temporal relationships of vesicles, osteopontin, mineral, and collagen are being examined further by these approaches.

NASA Discipline Musculoskeletal↗

In-Space Inspection Needs: Opportunities for advanced NDE tools such as x-ray CT for additively manufactured parts, in-situ resource utilization, geological applications, and more

It is now 50 years since the first human presence on the surface of the Moon and as we strive to return with women and men in the next few years, we embrace new technical challenges, goals, and innovative solutions to address 21st century objectives. These new ambitions carry fresh challenges and risks, with the field of NDE playing an increasingly more relevant role towards meeting these essential goals. In recent years, more advanced NDE tools have triggered a rapid expansion of applications for the space industry. In particular, x-ray Computed Tomography (CT) has proven to be a trusted and powerful asset for spaceflight hardware inspection, as well as applied geotechnical analysis for natural materials (e.g., rocks, soils) for NASA and across industry. However, such methods have yet to be extended to “deep space” applications such as those that are now part of the US National Space Policy Directive (SPD-1) and the accelerated push to return humans to the Moon (i.e., Artemis). For this reason, advancing these powerful Earth-based laboratory methods via new technologies, integrated computational solutions, and creative engineering approaches is directly aligned with national space policies, as well as with multiple NASA Strategic Plan priorities. The use of x-ray CT at scales as fine as a few microns or smaller can identify spacecraft part failure modes relevant to quality assurance for flight hardware and AM parts such as those recently developed for ISS. This technology could also identify valuable metallic phases within geological materials (i.e., rocks or drill cores), enabling resource-relevant triage of samples for In-Situ Resource Utilization (ISRU) and high science value sample return to Earth laboratories. There is also significant application for 3D imaging tools for medical use such as inspecting protective gear as well as bone density degradation studies which are critical in establishing a sustained presence in space. Timing for development of these tools for space use is advantageous as we prepare for new opportunities in the next few years and recognize recent commercial technology advancements which make it feasible. Moreover, as NASA strives to take full advantage of developments in AM technologies, including In-Space Manufacturing (ISM), it is widely recognized that NDE tools such as CT will play an essential role in acceptance of these parts for widespread use. New in-space 3D inspection tools with complimentary technology such as AI-based automated feature recognition (accelerated by machine learning), rapid compositional analysis, and advanced sample manipulation, would be a game-changing step toward a new class of crew-based laboratory sensors once human outposts on the Moon are established.

In-Space Non-Destructive Evaluation↗

Spectroscopic characterization of collagen cross-links in bone

Collagen is the most abundant protein of the organic matrix in mineralizing tissues. One of its most critical properties is its cross-linking pattern. The intermolecular cross-linking provides the fibrillar matrices with mechanical properties such as tensile strength and viscoelasticity. In this study, Fourier transform infrared (FTIR) spectroscopy and FTIR imaging (FTIRI) analyses were performed in a series of biochemically characterized samples including purified collagen cross-linked peptides, demineralized bovine bone collagen from animals of different ages, collagen from vitamin B6-deficient chick homogenized bone and their age- and sex-matched controls, and histologically stained thin sections from normal human iliac crest biopsy specimens. One region of the FTIR spectrum of particular interest (the amide I spectral region) was resolved into its underlying components. Of these components, the relative percent area ratio of two subbands at approximately 1660 cm(-1) and approximately 1690 cm(-1) was related to collagen cross-links that are abundant in mineralized tissues (i.e., pyridinoline [Pyr] and dehydrodihydroxylysinonorleucine [deH-DHLNL]). This study shows that it is feasible to monitor Pyr and DHLNL collagen cross-links spatial distribution in mineralized tissues. The spectroscopic parameter established in this study may be used in FTIRI analyses, thus enabling the calculation of relative Pyr/DHLNL amounts in thin (approximately 5 microm) calcified tissue sections with a spatial resolution of approximately 7 microm.

Non-NASA Center↗

Industrial Inspection System

Lixi, Inc. has built a thriving business on NASA-developed x-ray technology. The Low Intensity X-ray Imaging scope (LIXI) was designed to use less than one percent of radiation required by conventional x-ray devices. It is portable and can be used for a variety of industrial inspection systems as well as medical devices. A food processing plant uses the new LIXI Conveyor system to identify small bone fragments in chicken. The chicken packages on a conveyor belt enter an x-ray chamber and the image is displayed on a monitor. Defects measuring less than a millimeter can be detected. An important advantage of the system is its ability to inspect 100 percent of the product right on the production line.

Source record↗

Earth benefits from space life sciences

The applications to medicine of various results from space exploration are examined. Improvements have been made in the management of cardiovascular disease, in particular the use of the ultrasonic scanner to image arteries in three dimensions, the use of excimer lasers to disrupt arterial plaques in coronary blood vessels, and the use of advanced electrodes for cardiac monitoring. A bone stiffness analyzer has helped to diagnose osteoporosis and aid in its treatment. An automated light microscope system is used for chromosome analysis, and an X-ray image intensifier called Lixiscope is used in emergency medical care. An advanced portable defibrillator has been developed for the heart, and an insulin delivery system has been derived from space microminiaturization techniques.

Garshnek, V.↗

Mechanical behavior analysis using small-size graphite disc compression testing with digital image correlation methods

The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.

36 MATERIALS SCIENCE↗