Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Blind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Efficacy and Safety of Two Different n-Butyl-2-Cyanoacrylates for the Embolization of Varicoceles: A Prospective, Randomized, Blinded Study

Purpose: This was a prospective, randomized, blinded comparative study of the efficacy and safety of two different n-butyl-2-cyanoacrylates (NBCAs) for embolization of varicoceles. Methods: A total of 112 insufficient spermatic veins (left-sided, n = 84; right-sided, n = 28) that were diagnosed in 83 adult males were prospectively randomized for blinded embolization with NBCA (n = 54; Histoacryl, Braun, Germany) or NBCA-MS (n = 58; Glubran2, General Enterprise Marketing, Viareggio, Lucca, Italy). Handling, embolic efficacy, and safety of both NBCAs were compared according the fulfillment of a standardized embolization plan, the occlusive effect on the spermatic vein, and the sticking to the microcatheter. Statistical analysis was performed with the Mann-Whitney U test and the Fisher's exact test. Results: Patients of both study arms were comparable for age and clinical indication. Spermatic vein characteristics were comparable for varicocele classification and embolization side. Both NBCAs were equally efficient in occluding the spermatic vein and blocking reflux (NBCA, n = 54/54, 100% vs. NBCA-MS, n = 54/57, 94.7%; P = 0.244). The embolization plan could be accomplished in an equal number of veins for both groups (NBCA, n = 45/54, 83.3% vs. NBCA-MS, n = 41/58, 70.7%; P = 0.124). Adhesiveness of the glue to the microcatheter was the same in both NBCA groups (NBCA, n = 25/54, 46.3% vs. NBCA-MS, n = 29/58, 50%; P = 0.71). No glue-related complications were noted. Conclusions: NBCA and NBCA-MS are equally efficient and safe glues for embolization of varicoceles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Permanent Cortical Blindness After Bronchial Artery Embolization

A 35-year-old female with a known medical history of cystic fibrosis was admitted to our institution for massive hemoptysis. CTA depicted a hypertrophied bronchial artery to the right upper lobe and showed signs of recent bleeding at that location. Bronchial artery embolization (BAE) was performed with gelfoam slurry, because pronounced shunting to the pulmonary artery was present. Immediately after BAE, the patient developed bilateral cortical blindness. Control angiography showed an initially not opacified anastomosis between the embolized bronchial artery and the right subclavian artery, near to the origin of the right vertebral artery. Cessation of outflow in the bronchial circulation reversed the flow through the anastomosis and allowed for spill of embolization material into the posterior circulation. Unfortunately the cortical blindness presented was permanent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ZnO polymer composite based visible blind UV photo detector

Highlights: • The spherically shaped ZnO NPs with uniform size (∼40 nm) were synthesized. • Optical and the UV detection properties of polymer composites were measured. • ZnO-PVP sample has the potential as a material for visible blind photo detector. • Dielectric medium perturbs electron-phonon interaction and UV detection mechanism. - Abstract: Spherical ZnO nanoparticles with average diameter ∼50 nm are synthesized by hydrothermal method. Composites of the nanoparticles with different polymers have been prepared and UV detection properties are measured. The dielectric medium perturbs electron-phonon interaction as well as the optoelectronic properties. Moreover, the luminescence properties of the materials effected due to composite formation. In case of NP-polymer composite NPs are capped and there is negligible further adsorption and desorption of O{sub 2} molecules occurred on the surface. This increases the photocurrent as well as photosensitivity. For ZnO based photo detector, there is a small but not negligible photo response near 620 nm. The photo response in this particular wavelength is not observed in case of ZnO-PVP composite and it can be used as visible blind UV detector.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Single-Blind Quantification of Natural Gas Leaks from 1 km Distance Using Frequency Combs

A new method is tested in a single-blind study for detection, attribution, and quantification of methane emissions from the natural gas supply chain, which contribute substantially to annual U.S. emissions. The monitoring approach couples atmospheric methane concentration measurements from an open-path dual frequency comb laser spectrometer with meteorological data in an inversion to characterize emissions. During single-blind testing, the spectrometer is placed >1 km from decommissioned natural gas equipment configured with intentional leaks of control- lable rate. Single, steady emissions ranging from 0 to 10.7 g min -1 (0-34.7 scfh) are detected, located, and quantified at three gas pads of varying size and complexity. The system detects 100% of leaks, including leaks as small as 0.96 g min -1 (3.1 scfh). It attributes leaks to the correct pad or equipment group (tank battery, separator battery, wellhead battery) 100% of the time and to the correct equipment (specific separator, tank, or wellhead) 67% of the time. All leaks are quantified to within 3.7 g min -1 (12 scfh); 94% are quantified to within 2.8 g min -1 (9 scfh). Finally, these tests are an important initial demonstration of the methodology’s viability for continuous monitoring of large regions, with extension to other trace gases and industries.

03 NATURAL GAS↗

Evaluation of In Silico Multifeature Libraries for Providing Evidence for the Presence of Small Molecules in Synthetic Blinded Samples

The current gold standard for unambiguous molecular identification in metabolomics analysis is comparing two or more orthogonal properties from the analysis of authentic reference materials (standards) to experimental data acquired in the same laboratory with the same analytical methods. This represents a significant limitation for comprehensive chemical identification of small molecules in complex samples. The process is time-consuming and costly, and the majority of molecules are not yet represented by standards. Thus, there is a need to assemble evidence for the presence of small molecules in complex samples through the use of libraries containing calculated chemical properties. To address this need, we developed a Multi-Attribute Matching Engine (MAME) and a library derived in-part from our in silico Chemical Library Engine (ISiCLE). Here, we describe an initial evaluation of these methods in a blinded analysis of synthetic chemical mixtures as part of the U.S. Environmental Protection Agency’s (EPA) Non-Targeted Analysis Collaborative Trial (ENTACT, Phase 1). For molecules in all mixtures, the initial blinded false negative rate (FNR), false discovery rate (FDR), and accuracy were 57%, 77%, and 91%, respectively. For high evidence scores, the FDR was 35%. After unblinding of the sample compositions, we optimized the scoring parameters to better exploit the available evidence, and increased the accuracy for molecules suspected as present. The final FNR, FDR, and accuracy were 67%, 53%, and 96%, respectively. For high evidence scores, the FDR was 10%. This study demonstrates that multi-attribute matching methods in conjunction with in silico libraries may one day enable reduced reliance on experimentally-derived libraries for building evidence for the presence of molecules in complex samples.

Nunez, Jamie↗

Visible-Blind UV Photodetector Based on Single-Walled Carbon Nanotube Thin Film/ZnO Vertical Heterostructures

Ultraviolet (UV) photodetectors based on heterojunctions of conventional (Ge, Si, and GaAs) and wide bandgap semiconductors have been recently demonstrated, but achieving high UV sensitivity and visible-blind photodetection still remains a challenge. Here in this work, we utilized a semitransparent film of p-type semiconducting single-walled carbon nanotubes (SC-SWNTs) with an energy gap of 0.68 ± 0.07 eV in combination with a molecular beam epitaxy grown n-ZnO layer to build a vertical p-SC-SWNT/n-ZnO heterojunction-based UV photodetector. The resulting device shows a current rectification ratio of 10 3 , a current photoresponsivity up to 400 A/W in the UV spectral range from 370 to 230 nm, and a low dark current. The detector is practically visible-blind with the UV-to-visible photoresponsivity ratio of 10 5 due to extremely short photocarrier lifetimes in the one-dimensional SWNTs because of strong electron–phonon interactions leading to exciton formation. Finallyl, in this vertical configuration, UV radiation penetrates the top semitransparent SC-SWNT layer with low losses (10–20%) and excites photocarriers within the n-ZnO layer in close proximity to the p-SC-SWNT/n-ZnO interface, where electron–hole pairs are efficiently separated by a high built-in electric field associated with the heterojunction.

36 MATERIALS SCIENCE↗

Interface engineering of high-Mg-content MgZnO/BeO/Si for p-n heterojunction solar-blind ultraviolet photodetectors

High-quality wurtzite MgZnO film was deposited on Si(111) substrate via a delicate interface engineering using BeO, by which solar-blind ultraviolet photodetectors were fabricated on the n-MgZnO(0001)/p-Si(111) heterojunction. A thin Be layer was deposited on clean Si surface with subsequent in situ oxidation processes, which provides an excellent template for high-Mg-content MgZnO growth. The interface controlling significantly improves the device performance, as the photodetector demonstrates a sharp cutoff wavelength at 280 nm, consistent with the optical band gap of the epilayer. Our experimental results promise potential applications of this technique in integration of solar-blind ultraviolet optoelectronic device with Si microelectronic technologies.

36 MATERIALS SCIENCE↗

Al{sub x}Ga{sub 1−x}N-based solar-blind ultraviolet photodetector based on lateral epitaxial overgrowth of AlN on Si substrate

We report on Al{sub x}Ga{sub 1−x}N-based solar-blind ultraviolet (UV) photodetector (PD) grown on Si(111) substrate. First, Si(111) substrate is patterned, and then metalorganic chemical vapor deposition is implemented for a fully-coalesced ∼8.5 μm AlN template layer via a pulsed atomic layer epitaxial growth technique. A back-illuminated p-i-n PD structure is subsequently grown on the high quality AlN template layer. After processing and implementation of Si(111) substrate removal, the optical and electrical characteristic of PDs are studied. Solar-blind operation is observed throughout the array; at the peak detection wavelength of 290 nm, 625 μm{sup 2} area PD showed unbiased peak external quantum efficiency and responsivity of ∼7% and 18.3 mA/W, respectively, with a UV and visible rejection ratio of more than three orders of magnitude. Electrical measurements yielded a low-dark current density below 1.6 × 10{sup −8} A/cm{sup 2} at 10 V reverse bias.

36 MATERIALS SCIENCE↗

Al{sub x}Ga{sub 1-x}N-based back-illuminated solar-blind photodetectors with external quantum efficiency of 89%

We report on high performance Al{sub x}Ga{sub 1−x}N-based solar-blind ultraviolet photodetector (PD) array grown on sapphire substrate. First, high quality, crack-free AlN template layer is grown via metalorganic chemical vapor deposition. Then, we systematically optimized the device design and material doping through the growth and processing of multiple devices. After optimization, uniform and solar-blind operation is observed throughout the array; at the peak detection wavelength of 275 nm, 729 μm{sup 2} area PD showed unbiased peak external quantum efficiency and responsivity of ∼80% and ∼176 mA/W, respectively, increasing to 89% under 5 V of reverse bias. Taking the reflection loses into consideration, the internal quantum efficiency of these optimized PD can be estimated to be as high as ∼98%. The visible rejection ratio measured to be more than six orders of magnitude. Electrical measurements yielded a low-dark current density: <2 × 10{sup −9} A/cm{sup 2}, at 10 V of reverse bias.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-performance solar-blind ultraviolet photodetector based on mixed-phase ZnMgO thin film

High Mg content mixed-phase Zn{sub 0.38}Mg{sub 0.62}O was deposited on a-face sapphire by plasma-assisted molecular beam epitaxy, based on which a metal-semiconductor-metal solar-blind ultraviolet (UV) photodetector was fabricated. The dark current is only 0.25 pA at 5 V, which is much lower than that of the reported mixed-phase ZnMgO photodetectors. More interestingly, different from the other mixed-phase ZnMgO photodetectors containing two photoresponse bands, this device shows only one response peak and its −3 dB cut-off wavelength is around 275 nm. At 10 V, the peak responsivity is as high as 1.664 A/W at 260 nm, corresponding to an internal gain of ∼8. The internal gain is mainly ascribed to the interface states at the grain boundaries acting as trapping centers of photogenerated holes. In view of the advantages of mixed-phase ZnMgO photodetectors over single-phase ZnMgO photodetectors, including easy fabrication, high responsivity, and low dark current, our findings are anticipated to pave a new way for the development of ZnMgO solar-blind UV photodetectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Visible-blind ultraviolet photodiode fabricated by UV oxidation of metallic zinc on p-Si

A UV photodiode fabricated by the UV oxidation of a metallic zinc thin film on p-Si has manifested unique photoresponse characteristics. The electron concentration found by the Hall measurement was 3 × 10{sup 16 }cm{sup −3}, and such a low electron concentration resulted in a low visible photoluminescence. UV illumination enhances the oxidation at low temperatures and decreases the concentration of the oxygen vacancies. The I-V characteristic showed a good rectification with a four-order magnitude difference in the forward and reverse currents at 2 V, and its linear and frequency independent C{sup −2}–V characteristic confirmed an abrupt pn junction. The photoresponse showed a visible blindness with a responsivity ratio of UV and visible light as high as 100. Such a visible-blind photoresponse was attributed to the optimum thickness of the SiO{sub 2} formed on the Si surface during the UV oxidation at 400 °C. A lower potential barrier to holes at the ZnO/SiO{sub 2} interface facilitates Fowler-Nordheim tunneling of the photo-generated holes during the UV illumination, while a higher potential barrier to electrons efficiently blocks transport of the photo-generated electrons to the ZnO during the visible light illumination. The presence of oxide resulted in a slow photoresponse to the turn-on and off of the UV light. A detailed analysis is presented to understand how the photo-generated carriers contribute step by step to the photocurrent. In addition to the slow photoresponse associated with the SiO{sub 2} interfacial layer, the decay of the photocurrent was found extremely slow after turn-off of the UV light. Such a slow decay of the photocurrent is referred to as a persistent photoconductivity, which is caused by metastable deep levels. It is hypothesized that Zn vacancies form such a deep level, and that the photo-generated electrons need to overcome a thermal-energy barrier for capture. The ZnO film by the UV oxidation at 400 °C was found to be rich in oxygen and deficient in zinc.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High performance CaS solar-blind ultraviolet photodiodes fabricated by seed-layer-assisted growth

CaS, with a direct bandgap of 5.38 eV, is expected to be a strong candidate as the active-layer of high performance solar-blind UV photodiodes that have important applications in both civilian and military sectors. Here, we report that a seed-layer-assisted growth approach via molecular beam epitaxy can result in high crystalline quality rocksalt CaS thin films on zincblende GaAs substrates. The Au/CaS/GaAs solar-blind photodiodes demonstrated , more than five orders in its visible rejection power, a photoresponse of 36.8 mA/w at zero bias and a corresponding quantum efficiency as high as 19% at 235 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BLIND EXTRACTION OF AN EXOPLANETARY SPECTRUM THROUGH INDEPENDENT COMPONENT ANALYSIS

Blind-source separation techniques are used to extract the transmission spectrum of the hot-Jupiter HD189733b recorded by the Hubble/NICMOS instrument. Such a 'blind' analysis of the data is based on the concept of independent component analysis. The detrending of Hubble/NICMOS data using the sole assumption that nongaussian systematic noise is statistically independent from the desired light-curve signals is presented. By not assuming any prior or auxiliary information but the data themselves, it is shown that spectroscopic errors only about 10%-30% larger than parametric methods can be obtained for 11 spectral bins with bin sizes of {approx}0.09 {mu}m. This represents a reasonable trade-off between a higher degree of objectivity for the non-parametric methods and smaller standard errors for the parametric de-trending. Results are discussed in light of previous analyses published in the literature. The fact that three very different analysis techniques yield comparable spectra is a strong indication of the stability of these results.

79 ASTRONOMY AND ASTROPHYSICS↗

A blind green bank telescope millimeter-wave survey for redshifted molecular absorption

We present the methodology for 'blind' millimeter-wave surveys for redshifted molecular absorption in the CO/HCO{sup +} rotational lines. The frequency range 30-50 GHz appears optimal for such surveys, providing sensitivity to absorbers at z ≳ 0.85. It is critical that the survey is 'blind', i.e., based on a radio-selected sample, including sources without known redshifts. We also report results from the first large survey of this kind, using the Q-band receiver on the Green Bank Telescope (GBT) to search for molecular absorption toward 36 sources, 3 without known redshifts, over the frequency range 39.6-49.5 GHz. The GBT survey has a total redshift path of Δz ≈ 24, mostly at 0.81 < z < 1.91, and a sensitivity sufficient to detect equivalent H{sub 2} column densities ≳ 3 × 10{sup 21} cm{sup –2} in absorption at 5σ significance (using CO-to-H{sub 2} and HCO{sup +}-to-H{sub 2} conversion factors of the Milky Way). The survey yielded no confirmed detections of molecular absorption, yielding the 2σ upper limit n(z = 1.2) < 0.15 on the redshift number density of molecular gas at column densities N(H{sub 2}) ≳ 3 × 10{sup 21} cm{sup –2}.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulations of cm-wavelength Sunyaev-Zel'dovich galaxy cluster and point source blind sky surveys and predictions for the RT32/OCRA-f and the Hevelius 100-m radio telescope

We investigate the effectiveness of blind surveys for radio sources and galaxy cluster thermal Sunyaev-Zel'dovich effects (TSZEs) using the four-pair, beam-switched OCRA-f radiometer on the 32-m radio telescope in Poland. The predictions are based on mock maps that include the cosmic microwave background, TSZEs from hydrodynamical simulations of large scale structure formation, and unresolved radio sources. We validate the mock maps against observational data, and examine the limitations imposed by simplified physics. We estimate the effects of source clustering towards galaxy clusters from NVSS source counts around Planck-selected cluster candidates, and include appropriate correlations in our mock maps. The study allows us to quantify the effects of halo line-of-sight alignments, source confusion, and telescope angular resolution on the detections of TSZEs. We perform a similar analysis for the planned 100-m Hevelius radio telescope (RTH) equipped with a 49-beam radio camera and operating at frequencies up to 22 GHz.We find that RT32/OCRA-f will be suitable for small-field blind radio source surveys, and will detect 33{sup +17}{sub −11} new radio sources brighter than 0.87 mJy at 30 GHz in a 1 deg{sup 2} field at > 5σ CL during a one-year, non-continuous, observing campaign, taking account of Polish weather conditions. It is unlikely that any galaxy cluster will be detected at 3σ CL in such a survey. A 60-deg{sup 2} survey, with field coverage of 2{sup 2} beams per pixel, at 15 GHz with the RTH, would find <1.5 galaxy clusters per year brighter than 60 μJy (at 3σ CL), and would detect about 3.4 × 10{sup 4} point sources brighter than 1 mJy at 5σ CL, with confusion causing flux density errors ∼< 2% (20%) in 68% (95%) of the detected sources.A primary goal of the planned RTH will be a wide-area (π sr) radio source survey at 15 GHz. This survey will detect nearly 3 × 10{sup 5} radio sources at 5σ CL down to 1.3 mJy, and tens of galaxy clusters, in one year of operation with typical weather conditions. Confusion will affect the measured flux densities by ∼< 1.5% (16%) for 68% (95%) of the point sources. We also gauge the impact of the RTH by investigating its performance if equipped with the existing RT32 receivers, and the performance of the RT32 equipped with the RTH radio camera.

79 ASTRONOMY AND ASTROPHYSICS↗

In-flight polarization angle calibration for LiteBIRD: blind challenge and cosmological implications

We present a demonstration of the in-flight polarization angle calibration for the JAXA/ISAS second strategic large class mission, LiteBIRD, and estimate its impact on the measurement of the tensor-to-scalar ratio parameter, r, using simulated data. We generate a set of simulated sky maps with CMB and polarized foreground emission, and inject instrumental noise and polarization angle offsets to the 22 (partially overlapping) LiteBIRD frequency channels. Our in-flight angle calibration relies on nulling the EB cross correlation of the polarized signal in each channel. This calibration step has been carried out by two independent groups with a blind analysis, allowing an accuracy of the order of a few arc-minutes to be reached on the estimate of the angle offsets. Both the corrected and uncorrected multi-frequency maps are propagated through the foreground cleaning step, with the goal of computing clean CMB maps. We employ two component separation algorithms, the Bayesian-Separation of Components and Residuals Estimate Tool (B-SeCRET), and the Needlet Internal Linear Combination (NILC). We find that the recovered CMB maps obtained with algorithms that do not make any assumptions about the foreground properties, such as NILC, are only mildly affected by the angle miscalibration. However, polarization angle offsets strongly bias results obtained with the parametric fitting method. Once the miscalibration angles are corrected by EB nulling prior to the component separation, both component separation algorithms result in an unbiased estimation of the r parameter. While this work is motivated by the conceptual design study for LiteBIRD, its framework can be broadly applied to any CMB polarization experiment. In particular, the combination of simulation plus blind analysis provides a robust forecast by taking into account not only detector sensitivity but also systematic effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of foreground moment deprojection for semi-blind CMB polarization reconstruction

Abstract Upcoming Cosmic Microwave Background (CMB) experiments, aimed at measuring primordial CMB polarization B-modes, require exquisite control of instrumental systematics and Galactic foreground contamination. Blind minimum-variance techniques, like the Needlet Internal Linear Combination (NILC), have proven effective in reconstructing the CMB polarization signal and mitigating foregrounds and systematics across diverse sky models without suffering from foreground mismodelling errors. Still, residual foreground contamination from NILC may bias the recovered CMB polarization at large angular scales when confronted with the most complex foreground scenarios.By adding constraints to NILC to deproject statistical moments of the Galactic emission, the Constrained Moment ILC (cMILC) method has been demonstrated to further enhance foreground subtraction, albeit with an associated increase in overall noise variance. Faced with this trade-off between foreground bias reduction and overall variance minimization, there is still no recipe on which moments to deproject and which are better suited for blind variance minimization. To address this, we introduce the optimized cMILC (ocMILC) pipeline, which performs full automated optimization of the required number and set of foreground moments to deproject, pivot parameter values, and deprojection coefficients across the sky and angular scales, depending on the actual sky complexity, available frequency coverage, and experiment sensitivity. The optimal number of moments for deprojection, before paying significant noise penalty, is determined through a data diagnosis inspired by the Generalized NILC (GNILC) method.Validated on B-mode simulations of thePICOspace mission concept with four challenging foreground models, ocMILC exhibits lower Galactic foreground contamination compared to NILC and cMILC at all angular scales, with limited noise penalty. This multi-layer optimization enables the ocMILC pipeline to achieve unbiased posteriors of the tensor-to-scalar ratio, regardless of foreground complexity.

Astronomy & Astrophysics↗

DEFINING THE 'BLIND SPOT' OF HINODE EIS AND XRT TEMPERATURE MEASUREMENTS

Observing high-temperature, low emission measure plasma is key to unlocking the coronal heating problem. With current instrumentation, a combination of EUV spectral data from Hinode Extreme-ultraviolet Imaging Spectrometer (EIS; sensitive to temperatures up to 4 MK) and broadband filter data from Hinode X-ray Telescope (XRT; sensitive to higher temperatures) is typically used to diagnose the temperature structure of the observed plasma. In this Letter, we demonstrate that a 'blind spot' exists in temperature-emission measure space for combined Hinode EIS and XRT observations. For a typical active region core with significant emission at 3-4 MK, Hinode EIS and XRT are insensitive to plasma with temperatures greater than {approx}6 MK and emission measures less than {approx}10{sup 27} cm{sup -5}. We then demonstrate that the temperature and emission measure limits of this blind spot depend upon the temperature distribution of the plasma along the line of sight by considering a hypothetical emission measure distribution sharply peaked at 1 MK. For this emission measure distribution, we find that EIS and XRT are insensitive to plasma with emission measures less than {approx}10{sup 26} cm{sup -5}. We suggest that a spatially and spectrally resolved 6-24 Angstrom-Sign spectrum would improve the sensitivity to these high-temperature, low emission measure plasma.

79 ASTRONOMY AND ASTROPHYSICS↗