Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beamline IDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development and implementation of a portable grating interferometer system as a standard tool for testing optics at the Advanced Photon Source beamline 1-BM

We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APS beamlines for beam coherence and wavefront characterization or imaging. Herein, the design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.

47 OTHER INSTRUMENTATION↗

Measurements of source emittance and beam coherence properties of the upgraded Advanced Photon Source

The Advanced Photon Source (APS) has been upgraded with a multi-bend achromat lattice, achieving significantly reduced electron beam emittance and enhanced X-ray coherence. Precise characterization of these properties is essential for optimizing beamline performance and enabling new experiments that take full advantage of the upgraded source. We report on measurements of source size and transverse coherence properties using grating interferometry at two beamlines: the APS 3-ID-B undulator beamline and the 1-BM-B bending magnet beamline. The results confirm the world-record horizontal emittance of the upgraded APS below 30 pm rad and validate the theoretical design parameters. We further investigate the impact of optical aberrations and mechanical vibrations at the 12-ID-C beamline on coherence preservation. These measurements establish a benchmark for future beamline enhancements and demonstrate the effectiveness of grating interferometry for high-precision beam characterization. Our findings provide critical insights into synchrotron beam dynamics, coherence degradation mechanisms, and strategies for optimizing beamline X-ray optics at next-generation light sources.

Advanced Photon Source↗

Study of multilayer-reflected beam profiles and their coherence properties using beamlines ID19 (ESRF) and 32-ID (APS)

The use of multilayer mirrors is an interesting alternative for reflective X-ray monochromatization with respect to reflection from crystal optics. The increased photon flux density due to the multilayers' larger bandwidth is of crucial importance for, e.g, full-field X-ray imaging applications. Drawbacks are the introduced modifications of the reflected beam profile as well as a certain loss of coherence, summarized as wavefront degradation. Our recent work has shown that the modification of the beam profile can vary with, e.g., the material composition of the coating applied. In order to verify our findings, a beamline round-robin has been initiated, comparing the wavefront profiles after reflection by selected multilayers at beamlines 32-ID (Advanced Photon Source) and ID19 (European Synchrotron Radiation Facility) with our initial results acquired at BM05 (ESRF) [1].

43 PARTICLE ACCELERATORS↗

Energy optimization of a regular macromolecular crystallography beamline for ultra-high-resolution crystallography

A practical method for operating existing undulator synchrotron beamlines at photon energies considerably higher than their standard operating range is described and applied at beamline 19-ID of the Structural Biology Center at the Advanced Photon Source enabling operation at 30 keV. Adjustments to the undulator spectrum were critical to enhance the 30 keV flux while reducing the lower- and higher-energy harmonic contamination. A Pd-coated mirror and Al attenuators acted as effective low- and high-bandpass filters. The resulting flux at 30 keV, although significantly lower than with X-ray optics designed and optimized for this energy, allowed for accurate data collection on crystals of the small protein crambin to 0.38 Å resolution.

Rosenbaum, Gerd↗

Simultaneous, single-pulse, synchrotron x-ray imaging and diffraction under gas gun loading

We develop a mini gas gun system for simultaneous, single-pulse, x-ray diffraction and imaging under high strain-rate loading at the beamline 32-ID of the Advanced Photon Source. In order to increase the reciprocal space covered by a small-area detector, a conventional target chamber is split into two chambers: a narrowed measurement chamber and a relief chamber. The gas gun impact is synchronized with synchrotron x-ray pulses and high-speed cameras. Depending on a camera’s capability, multiframe imaging and diffraction can be achieved. The proof-of-principle experiments are performed on single-crystal sapphire. The diffraction spots and images during impact are analyzed to quantify lattice deformation and fracture; diffraction peak broadening is largely caused by fracture-induced strain inhomogeneity. Finally, our results demonstrate the potential of such multiscale measurements for revealing and understanding high strain-rate phenomena at dynamic extremes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation of Thermally Induced Pores with Microstructural Features Using High Energy X-rays

Combined application of a near-field High Energy Diffraction Microscopy measurement of crystal lattice orientation fields and a tomographic measurement of pore distributions in a sintered nickel-based superalloy sample allows pore locations to be correlated with microstructural features. Furthermore, measurements were carried out at the Advanced Photon Source beamline 1-ID using an X-ray energy of 65 keV for each of the measurement modes. The nickel superalloy sample was prepared in such a way as to generate significant thermally induced porosity. A three-dimensionally resolved orientation map is directly overlaid with the tomographically determined pore map through a careful registration procedure. The data are shown to reliably reproduce the expected correlations between specific microstructural features (triple lines and quadruple nodes) and pore positions. With the statistics afforded by the 3D data set, we conclude that within statistical limits, pore formation does not depend on the relative orientations of the grains. The experimental procedures and analysis tools illustrated are being applied to a variety of materials problems in which local heterogeneities can affect materials properties.

36 MATERIALS SCIENCE↗

Five-dimensional crystallography

Here it is demonstrated how five-dimensional crystallography can be used to determine a comprehensive chemical kinetic mechanism in concert with the atomic structures of transient intermediates that form and decay during the course of the reaction. A method for determining a comprehensive chemical kinetic mechanism in macromolecular reactions is presented. The method is based on five-dimensional crystallography, where, in addition to space and time, temperature is also taken into consideration and an analysis based on singular value decomposition is applied. First results of such a time-resolved crystallographic study are presented. Temperature-dependent time-resolved X-ray diffraction measurements were conducted on the newly upgraded BioCARS 14-ID-B beamline at the Advanced Photon Source and aimed at elucidating a comprehensive kinetic mechanism of the photoactive yellow protein photocycle. Extensive time series of crystallographic data were collected at two temperatures, 293 K and 303 K. Relaxation times of the reaction extracted from these time series exhibit measurable differences for the two temperatures, hence demonstrating that five-dimensional crystallography is feasible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NSLS-II storage ring insertion device and front-end commissioning and operation

The National Synchrotron Light Source II (NSLS-II) is a state of the art 3 GeV third generation light source at Brookhaven National Laboratory. During spring/ summer of 2014, the storage ring was commissioned up to 50 mA without insertion devices. In the fall of 2014, we began commissioning of the project beamlines, which included seven insertion devices on six ID ports. Beamlines IXS, HXN, CSX-1, CSX-2, CHX, SRX, and XPD-1 consist of elliptically polarized undulator (EPU), damping wigglers (DW) and in-vacuum undulators (IVU) covering from VUV to hard x-ray range. In this paper, experience with commissioning and operation is discussed. We focus on reaching storage ring performance with IDs, including injection, design emittance, compensation of orbit distortions caused by ID residual field, source point stability, beam alignment and tools for control, monitoring and protection of the ring chambers from ID radiation.

43 PARTICLE ACCELERATORS↗

17-ID AMX-FMX Beamline Radiation Shielding Analysis

The NSLS-II BEAMLINE RADIATION SHIELDING POLICY has been stated as follows in reference 1: Radiation exposure to staff and users resulting from National Synchrotron Light Source II (NSLS-II) operations must comply with Brookhaven National Laboratory (BNL) and Department of Energy (DOE) radiation requirements and must be maintained as low as reasonably achievable (ALARA). Per the NSLS-II Shielding Policy (PS-C-ASD-POL-005), in continuously occupied areas during normal operation the dose rate is ALARA, and shall be < 0.5 mrem/h (based on occupancy of 2000 hours/year) or less than 1 rem in a year.

36 MATERIALS SCIENCE↗

New Homogeneous Standards by Atomic Layer Deposition for Synchrotron X-ray Fluorescence and Absorption Spectroscopies.

Quantification of synchrotron XRF analyses is typically done through comparisons with measurements on the NIST SRM 1832/1833 thin film standards. Unfortunately, these standards are inhomogeneous on small scales at the tens of percent level. We are synthesizing new homogeneous multilayer standards using the Atomic Layer Deposition technique and characterizing them using multiple analytical methods, including ellipsometry, Rutherford Back Scattering at Evans Analytical, Synchrotron X-ray Fluorescence (SXRF) at Advanced Photon Source (APS) Beamline 13-ID, Synchrotron X-ray Absorption Spectroscopy (XAS) at Advanced Light Source (ALS) Beamlines 11.0.2 and 5.3.2.1 and by electron microscopy techniques. Our motivation for developing much-needed cross-calibration of synchrotron techniques is borne from coordinated analyses of particles captured in the aerogel of the NASA Stardust Interstellar Dust Collector (SIDC). The Stardust Interstellar Dust Preliminary Examination (ISPE) team have characterized three sub-nanogram, {approx}1{micro}m-sized fragments considered as candidates to be the first contemporary interstellar dust ever collected, based on their chemistries and trajectories. The candidates were analyzed in small wedges of aerogel in which they were extracted from the larger collector, using high sensitivity, high spatial resolution >3 keV synchrotron x-ray fluorescence spectroscopy (SXRF) and <2 keV synchrotron x-ray transmission microscopy (STXM) during Stardust ISPE. The ISPE synchrotron techniques have complementary capabilities. Hard X-ray SXRF is sensitive to sub-fg mass of elements Z {ge} 20 (calcium) and has a spatial resolution as low as 90nm. X-ray Diffraction data were collected simultaneously with SXRF data. Soft X-ray STXM at ALS beamline 11.0.2 can detect fg-mass of most elements, including cosmochemically important oxygen, magnesium, aluminum and silicon, which are invisible to SXRF in this application. ALS beamline 11.0.2 has spatial resolution better than 25 nm. Limiting factors for Stardust STXM analyses were self-imposed limits of photon dose due to radiation damage concerns, and significant attenuation of <1500 eV X-rays by {approx}80{micro}m thick, {approx}25 mg/cm{sup 3} density silica aerogel capture medium. In practice, the ISPE team characterized the major, light elements using STXM (O, Mg, Al, Si) and the heavier minor and trace elements using SXRF. The two data sets overlapped only with minor Fe and Ni ({approx}1% mass abundance), providing few quantitative cross-checks. New improved standards for cross calibration are essential for consortium-based analyses of Stardust interstellar and cometary particles, IDPs. Indeed, they have far reaching application across the whole synchrotron-based analytical community. We have synthesized three ALD multilayers simultaneously on silicon nitride membranes and silicon and characterized them using RBS (on Si), XRF (on Si{sub 3}N{sub 4}) and STXM/XAS (holey Si{sub 3}N{sub 4}). The systems we have started to work with are Al-Zn-Fe and Y-Mg-Er. We have found these ALD multi-layers to be uniform at {micro}m- to nm scales, and have found excellent consistency between four analytical techniques so far. The ALD films can also be used as a standard for e-beam instruments, eg., TEM EELS or EDX. After some early issues with the consistency of coatings to the back-side of the membrane windows, we are confident to be able to show multi-analytical agreement to within 10%. As the precision improves, we can use the new standards to verify or improve the tabulated cross-sections.

43 PARTICLE ACCELERATORS↗

In situ X-ray data collection and structure phasing of protein crystals at Structural Biology Center 19-ID

A prototype of a 96-well plate scanner for in situ data collection has been developed at the Structural Biology Center (SBC) beamline 19-ID, located at the Advanced Photon Source, USA. The applicability of this instrument for protein crystal diffraction screening and data collection at ambient temperature has been demonstrated. Several different protein crystals, including selenium-labeled, were used for data collection and successful SAD phasing. Without the common procedure of crystal handling and subsequent cryo-cooling for data collection at T = 100 K, crystals in a crystallization buffer show remarkably low mosaicity (<0.1°) until deterioration by radiation damage occurs. Data presented here show that cryo-cooling can cause some unexpected structural changes. Based on the results of this study, the integration of the plate scanner into the 19-ID end-station with automated controls is being prepared. With improvement of hardware and software, in situ data collection will become available for the SBC user program including remote access.

59 BASIC BIOLOGICAL SCIENCES↗

In situ synchrotron X-ray total scattering measurements and analysis of colloidal CsPbX 3 nanocrystals during flow synthesis

In situ X-ray scattering measurements of CsPbX 3 (X = Cl, Br, I) nanocrystal formation and halide exchange at NSLS-II beamlines were performed in an automated flow reactor. Total scattering measurements were performed at the 28-ID-2 (XPD) beamline and small-angle X-ray scattering at the 16-ID (LiX) beamline. Nanocrystal structural parameters of interest, including size, size distribution and atomic structure, were extracted from modeling the total scattering data. The results highlight the potential of these beamlines and the measurement protocols described in this study for studying dynamic processes of colloidal nanocrystal synthesis in solution with timescales on the order of seconds.

nucleation↗

Small-Angle X-Ray Scattering on the ChemMatCARS Beamline at the Advanced Photon Source: A Study of Shear-Induced Crystallisation in Polypropylene

The first ever time-resolved small-angle X-ray scattering (SAXS) data from the undulator 15-ID-D beamline (ChemMatCARS) are presented. A 1.3 {angstrom} (9.54 keV) X-ray beam was selected to study the structure development in a polypropylene sample during shear-induced crystallization. A Linkam CSS450 shear cell provided the temperature and shear control. The polypropylene was first melted and then quenched to the crystallization temperature, where a step shear was applied. The SAXS data were collected using a Bruker 6000 CCD detector, which provided images of excellent resolution. The SAXS images (with 180{sup o} rotational symmetry) indicated that the polypropylene crystallizes with a high degree of anisotropy, and the lamellae are oriented perpendicular to the flow direction.

43 PARTICLE ACCELERATORS↗

Opticsconcept for apair of undulatorbeamlines for MX

We describe a concept for X-ray optics to feed a pair of macromolecular crystallography (MX) beamlines, which view canted undulator radiation sources in the same storage ring straight section. It can be deployed at NSLS-II and at other low-emittance third-generation synchrotron radiation sources where canted undulators are permitted, and makes the most of these sources and beamline floor space, even when the horizontal angle between the two canted undulator emissions is as little as 1-2 mrad. The concept adopts the beam-separation principles employed at the 23-ID (GM/CA-CAT) beamlines at the Advanced Photon Source (APS), wherein tandem horizontally deflecting mirrors separate one undulator beam from the other, following monochromatization by a double-crystal monochromator. The scheme described here would, in contrast, deliver the two tunable monochromatic undulator beams to separate endstations that address rather different and somewhat complementary purposes, with further beam conditioning imposed as required. A downstream micro-focusing beamline would employ dual-stage focusing for work at the micron scale and, unique to this design, switch to single-stage focusing for larger beams. On the other hand, the upstream, more highly automated beamline would only employ single-stage focusing.

43 PARTICLE ACCELERATORS↗

Real-time machine-learning-driven control system of a deformable mirror for achieving aberration-free X-ray wavefronts

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory. It achieved a response time of a few seconds and maintained desired wavefront shapes (e.g., a spherical wavefront) with sub-wavelength accuracy at 20 keV of X-ray energy. This result is significantly better than what can be obtained using a linear model of the mirror’s response. The developed system has not been tailored to a specific mirror and can be applied, in principle, to different kinds of bending mechanisms and actuators.

47 OTHER INSTRUMENTATION↗

Coded-mask-based wavefront sensing technique for APS nanofocusing beamline diagnostics

Here, we extend our recently developed coded-mask wavefront sensing technique to enable single-shot measurements of nanofocused x-ray beams. This method accurately reconstructs the focal beam profile by backpropagating the wavefront measured downstream of the beam focus. To validate its performance, we benchmarked it against the conventional fluorescence wire scan method, successfully measuring ∼120 nm focal spots at the 28-ID-B beamline of the Advanced Photon Source using a polymeric compound refractive lens. The results highlight the effectiveness of coded-mask wavefront sensing for high-precision beam profiling and its application as a real-time wavefront monitoring tool.

Shi, Xianbo [Argonne National Laboratory (ANL), Ar↗

Probing Fundamental Mechanisms of Plastic Deformation with High Energy X-rays (Final Progress Report)

Overall, substantial progress was made on developing BCDI techniques in the direction of imaging defects in multi-crystal samples. Section 2.1 describes a new method to reconstruct the 3D atomic displacement field within a grain from multiple coherently resolved diffraction peaks. The key development is the ability to recover a best fit to the grain shape at the same time as the internal displacement (strain) variation with no prior knowledge of the microstructure. This is complemented by the development of a method, Sec. 2.2, to separate out sets of Laue reflections that belong to a single grain (and thus be able to index its orientation) in the commonly encountered situation in which the beam illuminates several grains in a given location. This is essential for enabling collection of coherent diffraction data (at APS 34-ID-C) from neighboring grains. All experiments depend on the quality of samples used. Although good progress has been made with thin film samples, we are working with a broader range of geometries. A new sample design uses a high-Z metal (e.g., Pt) deposited in a sub-micron trench in a low-Z metal (e.g., Al) so that the grain size is prevented from exceeding the current limit for BCDI. We also report in section 3.1 on successfully applying NF-HEDM to a fine-grain Mg sample that would normally be considered out of scope for the method. This represents progress towards being able to map out polycrystalline samples in 3D before performing BCDI on individual grains. We further report in section 3.2 on preliminary NF-HEDM characterization of a sample of UO2 that has sub-micron grains; the data imply the capability of mapping fine-grain polycrystals at 1-ID-E, again for the purposes of BCDI in the bulk. Lastly, our plan is to load grains in polycrystalline samples by inducing thermal stress. We also report the experimental measurements of the Ti- 6Al-4V alloy obtained at the European Synchrotron Radiation Facility (ESRF), which had been indexed and mapped via HEDM at APS in section 9. As discussed below, however, technique development pre-occupied the team throughout the project which meant that we did not make any significant progress towards answering the original hypotheses as stated in the proposal. In summary, we assert that we have made good progress in methods and samples and future work taking advantage of this progress is likely to obtain and analyze BCDI data from multiple adjacent grains in 3D polycrystals. Obtaining such data depends on re-gaining access to the Advanced Photon Source, which is anticipated in late summer or the Fall. In all cases, work has involved close collaboration with faculty, staff, postdocs and students from Brigham Young University (BYU), the Los Alamos National Laboratory and APS beamlines 1-ID and 34-ID.

36 MATERIALS SCIENCE↗

Intact archeological human bones and age at death studied with transmission x–ray diffraction and small angle x–ray scattering

In this work, high-energy, wide-angle x-ray scattering (WAXS, x-ray diffraction) and small-angle x-ray scattering (SAXS) were used to study intact human second metacarpal bones (mc2) from two UK archeological sites. A novel method correcting for irregular mass distribution was applied in these transmission geometry experiments done at beamline 1-ID of the Advanced Photon Source. The authors asked whether there were age-at-death-related changes in carbonated apatite (cAp) lattice parameters and whether SAXS could detect collagen D-period peaks in the archeological mc2. For each of the two sites, Ancaster and Wharram Percy in England, six female mc2s were studied; for each site, two were from each of three age-at-death cohorts (young, 18-29 years; middle, 30-49 years; old >= 50 years) along with a modern control mc2. The Rietveld method was applied to the WAXS patterns to provide precise lattice parameter values. The cAp lattice parameters did not correlate with age-at-death estimated from dental wear. From WAXS and the 00.2 diffraction peak widths, four archeological mc2s possessed coherently scattering domain lengths (crystallite c-axis sizes) that matched that of the modern mc2; SAXS revealed the same four archeological mc2 had D-period peak intensities equivalent to that of the modern mc2. The other eight archeological mc2s had significantly larger crystallite sizes (than the modern mc2) and weak or absent D-period peaks, differences attributed to diagenetic changes. Based on these data, the authors suggest that WAXS 00.2 peak width and SAXS D-period peak intensity can be used with intact bones to select those likely to retain largely unaltered tissue nanostructure, which might be required for other analyses. Taken as a whole, the results suggest detecting age-related deterioration in nanostructural features may be difficult in bone showing significant bioerosion.

59 BASIC BIOLOGICAL SCIENCES↗