Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

High-resolution bandpass x-ray imaging with crystal reflectors: Overcoming geometric aberrations

The imaging problem of a specular reflector is revisited. Retaining terms through the second order in the reflector surface expansion, we derive the form of the aberration-limiting aperture for arbitrary magnification, assuming no bandwidth limitations. A permissible relative aperture size of the reflector is limited by a set relative aberration tolerance and scales with the tangent of the central glancing angle of incidence. These limiting aberrations become practically insignificant near backscattering. The results extend to x-ray diffracting crystals in symmetric Bragg geometry shaped as an ellipsoid of revolution. This geometry permits polychromatic imaging for hard x-rays over a bandwidth defined by the accepted range of Bragg angles, thereby suppressing aberrations of higher orders. We assess ellipsoidal crystal imagers using ray tracing simulations for two high-magnification designs with Bragg angles far from and close to backscattering. Finally, in both cases, the ellipsoidal crystals produce images of higher quality compared to those formed by equivalent toroidal crystal imagers.

Bragg reflection↗

Two-dimensional image edge enhancement using two orders of Bragg diffraction

The process of two-dimensional image edge enhancement with an acousto-optical spatial filter using two orders of light diffraction is studied. It is theoretically shown that the diffraction that occurs in a paratellurite crystal on a ‘slow’ acoustic wave propagating orthogonally to the optical axis of the crystal allows enhancing a two-dimensional edge of an image, transferred by optical radiation with a wavelength of 0.63 μm in a wide band of acoustic frequencies 25 – 50 MHz. Enhancement of a two-dimensional image edge at an acoustic frequency of 29 MHz is experimentally demonstrated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental studies of 1.5 – 1.6 μm high-power single-frequency semiconductor lasers

High-power semiconductor laser systems based on 1.5 – 1.6 μm single-frequency distributed feedback (DFB) lasers with a sidewall Bragg diffraction grating are developed and their current – voltage, light – current, and spectral characteristics are experimentally studied. The characteristics of conventional lasers with a Fabry – Perot cavity and DFB lasers fabricated from one and the same heterostructure are compared. At a pump current not exceeding 700 mA, a conventional laser with a cavity length of 1.6 mm and a mesa-stripe width of 3 μm emits a power no lower than 200 mW versus 150 mW of the DFB laser; both lasers are mounted in a housing 11 mm in diameter. The DFB laser mounted in a butterfly housing emits a power no lower than 100 mW at the exit of the single-mode cable at a pump current not exceeding 500 mA, which, at a 60 % coupling efficiency, corresponds to a power no lower than 165 mW; the side-mode suppression ratio in this case is no lower than 53 dB. It is shown that the wavelength deviation with changing pump current and temperature is almost an order of magnitude lower for the DFB laser than for the conventional laser. (paper)

36 MATERIALS SCIENCE↗

Structural origin of resonant diffraction in RuO2

We report Ru L3-edge resonant X-ray diffraction studies on single crystal and (001) oriented epitaxial films of RuO2. We investigate the distinct Q = (100) and (001) Bragg-forbidden reflections as a function of incident energy, azimuthal angle, and temperature. The results show that the observed resonant diffraction in RuO2 is fully consistent with a resonant charge anisotropy signal of structural origin permitted by the parent (non-magnetic) rutile P42/mnm space group. These results significantly constrain the magnetic contribution to the resonant diffraction signal and indicate the unlikely existence of k = 0 antiferromagnetic order in RuO2.

36 MATERIALS SCIENCE↗

Bragg Spot Finder (BSF): a new machine-learning-aided approach to deal with spot finding for rapidly filtering diffraction pattern images

Macromolecular crystallography contributes significantly to understanding diseases and, more importantly, how to treat them by providing atomic resolution 3D structures of proteins. This is achieved by collecting X-ray diffraction images of protein crystals from important biological pathways. Spotfinders are used to detect the presence of crystals with usable data, and the spots from such crystals are the primary data used to solve the relevant structures. Having fast and accurate spot finding is essential, but recent advances in synchrotron beamlines used to generate X-ray diffraction images have brought us to the limits of what the best existing spotfinders can do. This bottleneck must be removed so spotfinder software can keep pace with the X-ray beamline hardware improvements and be able to see the weak or diffuse spots required to solve the most challenging problems encountered when working with diffraction images. In this paper, we first present Bragg Spot Detection (BSD), a large benchmark Bragg spot image dataset that contains 304 images with more than 66 000 spots. We then discuss the open source extensible U-Net-based spotfinder Bragg Spot Finder (BSF), with image pre-processing, a U-Net segmentation backbone, and post-processing that includes artifact removal and watershed segmentation. Finally, we perform experiments on the BSD benchmark and obtain results that are (in terms of accuracy) comparable to or better than those obtained with two popular spotfinder software packages ( Dozor and DIALS ), demonstrating that this is an appropriate framework to support future extensions and improvements.

36 MATERIALS SCIENCE↗

DXRD : a user-friendly suite of two- and multiple-beam dynamical X-ray diffraction programs

The DXRD program suite consisting of a series of dynamical theory programs is introduced for computing dynamical X-ray diffraction from single crystals. Its interactive graphical user interfaces (GUIs) allow general users to make complicated calculations with minimal effort. It can calculate plane-wave Darwin curves of single crystals (or multiple crystals) for both the Bragg and Laue cases, including grazing-incidence diffraction and backward diffraction (with Bragg angles approaching 90°). It is also capable of simulating rocking curves for divergent incident X-ray beams with finite bandwidths. A unique feature of DXRD is that it provides a convenient GUI-based multiple-beam diffraction program that can accurately compute arbitrary N-beam diffraction of any geometry using a universal 4N × 4N matrix method. DXRD also provides a mapping program for plotting all the multiple-beam diffraction lines (monochromator glitches) in the azimuth–energy coordinate system. All these functions make DXRD a convenient and powerful software tool for designing crystal-based synchrotron/X-ray optics (monochromators, analyzers, polarizers, phase plates etc.) and for crystal characterization, X-ray spectroscopy and X-ray diffraction teaching.

Bragg reflection↗

High-power narrow spectrum GaSb-based DBR lasers emitting near 2.1 µm

Stable high-power narrow-linewidth operation of the 2.05–2.1 µm GaSb-based diode lasers was achieved by utilizing the sixth-order surface-etched distributed Bragg reflector (DBR) mirrors. The DBR multimode devices with 100 µm wide ridge waveguides generated ~850 mW in the continuous wave (CW) regime at 20°C. The device CW output power was limited by thermal rollover. The laser emission spectrum was defined by Bragg reflector reflectivity at all operating currents in a wide temperature range. Finally, the devices operated at DBR line with detuning from gain peak exceeding 10 meV.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Two-beam Bragg diffraction, filtering, and delays

We summarize transmission and reflection amplitudes of Bragg-crystals based on two-beam Bragg diffraction theory. Then, we consider a specific case of infinitely thick and symmetrical Bragg-crystal and its reflective properties in spectral and angular domain. We obtain analytical expressions for filtering width and respective delay amplitudes, temporal delay from spectral phase shift and spatial displacement from angular phase shift.

43 PARTICLE ACCELERATORS↗

Hard x-ray standing-wave photoemission study of the interfaces in a BiFeO$_3$/La$_{0.7}$Sr$_{0.3}$MnO$_3$ superlattice

Hybrid multiferroics such as BiFeO$_3$ (BFO) and La$_{0.7}$Sr$_{0.3}$MnO$_3$ (LSMO) heterostructures are highly interesting functional systems due to their complex electronic and magnetic properties. One of the key parameters influencing the emergent properties is the quality of interfaces, where varying interdiffusion lengths can give rise to different chemistry and distinctive electronic states. Here we report high-resolution depth resolved chemical and electronic investigation of BFO/LSMO superlattice using standing-wave hard X-ray photoemission spectroscopy in the first-order Bragg as well as near-total-reflection geometry. Our results show that the interfaces of BFO on top of LSMO are atomically abrupt, while the LSMO on top of BFO interfaces show an interdiffusion length of around 1.2 unit cells. The two interfaces also exhibit different chemical gradients, with the BFO/LSMO interface being Sr-terminated by a spectroscopically distinctive high binding energy component in Sr 2p core-level spectra, which is spatially contained within 1 unit cell from the interface. From the electronic point of view, unique valence band features were observed for bulk-BFO, bulk-LSMO and their interfaces. Our X-ray optical analysis revealed a unique electronic signature at the BFO/LSMO interface, which we attribute to the coupling between those respective layers. Valence band decomposition based on the Bragg-reflection standing-wave measurement also revealed the band alignment between BFO and LSMO layers. Our work demonstrates that standing-wave hard x-ray photoemission is a reliable non-destructive technique for probing depth-resolved electronic structure of buried layers and interfaces with sub-unit-cell resolution. Equivalent investigations can be successfully applied to a broad class of material such as perovskite complex oxides with emergent interfacial phenomena.

Martins, HP↗

Refinements for Bragg coherent X-ray diffraction imaging: electron backscatter diffraction alignment and strain field computation

Bragg coherent X-ray diffraction imaging (BCDI) allows the 3D measurement of lattice strain along the scattering vector for specific microcrystals. If at least three linearly independent reflections are measured, the 3D variation of the full lattice strain tensor within the microcrystal can be recovered. However, this requires knowledge of the crystal orientation, which is typically attained via estimates based on crystal geometry or synchrotron microbeam Laue diffraction measurements. Presented here is an alternative method to determine the crystal orientation for BCDI measurements using electron backscatter diffraction (EBSD) to align Fe–Ni and Co–Fe alloy microcrystals on three different substrates. The orientation matrix is calculated from EBSD Euler angles and compared with the orientation determined using microbeam Laue diffraction. The average angular mismatch between the orientation matrices is less than ∼6°, which is reasonable for the search for Bragg reflections. The use of an orientation matrix derived from EBSD is demonstrated to align and measure five reflections for a single Fe–Ni microcrystal via multi-reflection BCDI. Using this data set, a refined strain field computation based on the gradient of the complex exponential of the phase is developed. This approach is shown to increase accuracy, especially in the presence of dislocations. The results demonstrate the feasibility of using EBSD to pre-align BCDI samples and the application of more efficient approaches to determine the full lattice strain tensor with greater accuracy.

42 ENGINEERING↗

Low-loss stable storage of 1.2 Å X-ray pulses in a 14 m Bragg cavity

Here, we present an experimental demonstration of a stable, low-loss, large X-ray cavity operating at 1.2 Å wavelength. The cavity consists of four separate high-reflectivity single crystal diamond Bragg mirrors arranged in a rectangular configuration with a round-trip distance of 14.2 m. Femtosecond X-ray pulses from an X-ray free-electron laser were coupled into the cavity via a transmission phase grating. We show that a stable mode can be maintained with the introduction of cavity focusing and measure round-trip efficiencies approaching 88%, or >96% when excluding grating and lens losses, close to the Bragg mirror theoretical performance limit. The direct observation of sustained stable X-ray circulation provides the most direct evidence to date that cavity-based X-ray free-electron lasers and other cavity-based hard X-ray systems are feasible.

47 OTHER INSTRUMENTATION↗

Polarization-independent photonic Bragg grating filter with cladding asymmetry

A photonic Bragg grating is a fundamental building block that reflects the direction of wave propagation through spatial phase modulation and can be implemented using sidewall corrugation. However, due to the asymmetric aspect ratio of a waveguide cross section, typical Bragg gratings exhibit a strong polarization sensitivity. Here, we show that photonic Bragg gratings with cladding asymmetry can enable polarization-independent notch filters by rotating input polarizations. Such Bragg gratings strongly couple transverse electric (TE) and transverse magnetic (TM) modes propagating in opposite directions, filtering the input signal and reflecting the rotated mode. We analyzed this polarization-rotating Bragg grating using the coupled-mode theory and experimentally demonstrated it on a silicon-on-insulator platform. Our device concept is simple to implement and compatible with other platforms, readily available as polarization transparent Bragg components.

Pimbi, Daniel (ORCID:000000025933203X)↗

Polariton Control of Molecular Charge Transfer in Perylene Diimide Semiconductors

We report the modulation of molecular charge transfer in a bay-substituted perylene diimide derivative embedded in a planar distributed Bragg reflector microcavity. Angle-resolved reflectance spectra confirm the formation of upper and lower polaritons with clear Rabi splitting, indicating strong coupling between the cavity mode and molecular excitons. Using broadband transient absorption spectroscopy, we compare the ultrafast dynamics of cavity and non-cavity films. While excited-state absorption and stimulated emission pathways remain largely unchanged, kinetic modeling reveals a moderate increase in the charge transfer rate and yield under strong coupling. This enhancement is attributed to a reduction in the effective driving force via the formation of the lower polariton, placing the system deeper into the Marcus inverted regime. Our results demonstrate a promising non-chemical method leveraging cavity quantum electrodynamics to modulate charge separation processes in molecular semiconductors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variable Bragg x-ray beam splitters

Beam splitters are utilized in a variety of advanced x-ray instruments and are essential for extending quantum optics techniques to x rays. A new fabrication method has produced thinned Bragg diffracting silicon devices with variable reflectivity and transmission coefficients and negligible absorption losses. Diffraction measurements confirm that silicon continues to exhibit perfect crystal diffraction even for thicknesses below two microns. Devices are machined from standard wafers, with the thinned regions contained within the robust frame of an unperturbed crystal for ease of handling.

Powers, L. T. (ORCID:000900047481248X)↗