At least 73 records · Page 4

Control of joint motion simulators for biomechanical research

The authors present a hierarchical adaptive algorithm for controlling upper extremity human joint motion simulators. A joint motion simulator is a computer-controlled, electromechanical system which permits the application of forces to the tendons of a human cadaver specimen in such a way that the cadaver joint under study achieves a desired motion in a physiologic manner. The proposed control scheme does not require knowledge of the cadaver specimen dynamic model, and solves on-line the indeterminate problem which arises because human joints typically possess more actuators than degrees of freedom. Computer simulation results are given for an elbow/forearm system and wrist/hand system under hierarchical control. The results demonstrate that any desired normal joint motion can be accurately tracked with the proposed algorithm. These simulation results indicate that the controller resolved the indeterminate problem redundancy in a physiologic manner, and show that the control scheme was robust to parameter uncertainty and to sensor noise.

Colbaugh, R.

An improved simulation based biomechanical model to estimate static muscle loadings

The objectives of this study are to show that the characteristics of an intact muscle are different from those of an isolated muscle and to describe a simulation based model. This model, unlike the optimization based models, accounts for the redundancy in the musculoskeletal system in predicting the amount of forces generated within a muscle. The results of this study show that the loading of the primary muscle is increased by the presence of other muscle activities. Hence, the previous models based on optimization techniques may underestimate the severity of the muscle and joint loadings which occur during manual material handling tasks.

Rajulu, Sudhakar L.

Development of biomechanical models for human factors evaluations

Computer aided design (CAD) techniques are now well established and have become the norm in many aspects of aerospace engineering. They enable analytical studies, such as finite element analysis, to be performed to measure performance characteristics of the aircraft or spacecraft long before a physical model is built. However, because of the complexity of human performance, CAD systems for human factors are not in widespread use. The purpose of such a program would be to analyze the performance capability of a crew member given a particular environment and task. This requires the design capabilities to describe the environment's geometry and to describe the task's requirements, which may involve motion and strength. This in turn requires extensive data on human physical performance which can be generalized to many different physical configurations. PLAID is developing into such a program. Begun at Johnson Space Center in 1977, it was started to model only the geometry of the environment. The physical appearance of a human body was generated, and the tool took on a new meaning as fit, access, and reach could be checked. Specification of fields-of-view soon followed. This allowed PLAID to be used to predict what the Space Shuttle cameras or crew could see from a given point.

Woolford, Barbara

The use of biomechanics in the study of movement in microgravity

As biomechanists interested in the adaptability of the human body to microgravity conditions, it appears that our job is not only to make sure that the astronauts can function adequately in space but also that they can function upon their return to Earth. This is especially significant since many of the projects now being designed at NASA concern themselves with humans performing for up to 3 years in microgravity. While the Extended Duration Orbiter flights may last 30 to 60 days, future flights to Mars using current propulsion technology may last from 2 to 3 years. It is for this range of time that the adaptation process must be studied. Specifically, biomechanists interested in space travel realize that human performance capabilities will change as a result of exposure to microgravity. The role of the biomechanist then is to first understand the nature of the changes realized by the body. These changes include adaptation by the musculoskeletal system, the nervous system, cardiorespiratory system, and the cardiovascular system. As biomechanists, it is also our role to take part in the development of countermeasure programs that involve some form of regular exercise. Exercise countermeasure programs should include a variety of modalities with full knowledge of the loads imposed on the body by these modalities. Any exercise programs that are to be conducted by the astronauts during space travel must consider the fact that the musculoskeletal and neuromuscular systems degrade as a function of flight duration. Additionally, it must be understood that the central nervous system modifies its output in the control of the human body during space flight and most importantly, we must prepare the astronauts for their return to one g.

Gregor, R. J.

Biomechanically Induced and Controller Coupled Oscillations Experienced on the F-16XL Aircraft During Rolling Maneuvers

During rapid rolling maneuvers, the F-16 XL aircraft exhibits a 2.5 Hz lightly damped roll oscillation, perceived and described as 'roll ratcheting.' This phenomenon is common with fly-by-wire control systems, particularly when primary control is derived through a pedestal-mounted side-arm controller. Analytical studies have been conducted to model the nature of the integrated control characteristics. The analytical results complement the flight observations. A three-degree-of-freedom linearized set of aerodynamic matrices was assembled to simulate the aircraft plant. The lateral-directional control system was modeled as a linear system. A combination of two second-order transfer functions was derived to couple the lateral acceleration feed through effect of the operator's arm and controller to the roll stick force input. From the combined systems, open-loop frequency responses and a time history were derived, describing and predicting an analogous in-flight situation. This report describes the primary control, aircraft angular rate, and position time responses of the F-16 XL-2 aircraft during subsonic and high-dynamic-pressure rolling maneuvers. The analytical description of the pilot's arm and controller can be applied to other aircraft or simulations to assess roll ratcheting susceptibility.

Smith, John W.

Adaptation of Diaphyseal Structure With Aging and Increased Mechanical Usage in the Adult Rat: A Histomorphometrical and Biomechanical Study

The experimental increase in mechanical usage or overloading of the left hindlimb was produced by immobilization of the contralateral hindlimb. The right hindlimb was placed in a flexed position against the body and was immobilized using an elastic bandage. Some control animals were sacrificed initially at time zero and increased mechanical usage and age-matched control animals were sacrificed after 2, 10, 18, and 26 weeks of treatment. All animals received double bone fluorochrome labeling prior to sacrifice. Cortical bone histomorphometry and cross-sectional moments of inertia were determined. Marrow cavity enlargement and total cross-sectional area expansion represented the age-related cortical bone changes. Increased mechanical usage enhanced periosteal bone modeling in the formation mode and dampened endocortical bone remodeling and bone modeling in the resorption mode (resorption drift) to create a slight positive bone balance. These observations are in general agreement with Frost's postulate for mechanical effects on bone modeling and remodeling. The maximum moment of inertia did not change significantly in either control or overloaded tibial shafts. The minimum and polar moment of inertias in overloaded bones increases over those of controls at 18 and 26 weeks of the experiment.

Jee, Webster S. S.

Adaptation of Diaphyseal Structure with Aging and Increased Mechanical Usage in the Adult Rat: A Histomorphometrical and Biomechanical Study

The experimental increase in mechanical usage or overloading of the left hindlimb was produced by immobilization of the contralateral hindlimb. The right hindlimb was placed in a flexed position against the body and was immobilized using an elastic bandage. Some control animals were sacrificed initially at time zero and increased mechanical usage and age-matched control animals were sacrificed after 2, 10, 18, and 26 weeks of treatment. All animals received double bone fluorochrome labeling prior to sacrifice. Cortical bone histomorphometry and cross-sectional moments of inertia were determined. Marrow cavity enlargement and total cross-sectional area expansion represented the age-related cortical bone changes. Increased mechanical usage enhanced periosteal bone modeling in the formation mode and dampened endocortical bone remodeling and bone modeling in the resorption mode (resorption drift) to create a slight positive bone balance. These observations are in general agreement with Frost's postulate for mechanical effects on bone modeling and remodeling. The maximum moment of inertia did not change significantly in either control or overloaded tibial shafts. The minimum and polar moment of inertias in overloaded bones increases over those of controls at 18 and 26 weeks of the experiment.

Jee, Webster S. S.

Quantifying Biomechanical Characteristics of Jumping Exercises in 1G and in Simulated and True Microgravity

Exercise in microgravity is one of the most promising countermeasures to the dual problems of space flight-induced bone loss and muscle atrophy. Although exercise in microgravity has been studied extensively from a metabolic standpoint, little research has focused on the efficacy of different forms of exercise for maintaining musculoskeletal integrity. Exercise protocols have not been effective in preventing muscle atrophy and bone loss during space flight, especially in the lower extremities. In 1-G, however, animal experiments have clearly indicated that: (1) certain bone strains and strain rates do stimulate bone deposition, and (2) repetitive loading of the lower extremity can increase osteonal bone formation even as proximally as the vertebral column. Such studies have also indicated that a relatively small number of appropriate loading cycles may lead to bone deposition. This suggests that an optimal exercise regimen might be able to maintain bone and muscle integrity during space flight. Since there is evidence that the bones and muscles of the lower limbs are particularly affected by space flight, the present study addressed two major aims: (1) quantify externally applied impact loads and rates of loading under the feet during tethered jumping exercises, and (2) determine the amount of eccentric and concentric whole-muscle activity during these jumping exercises in true and in simulated zero-gravity.

Davis, B. L.

Expression of Novel Gene Products Upregulated by Disuse is Normalized by an Osteogenic Mechanical Stimulus: Evidence for the Molecular Basis of a Low Level Biomechanical Countermeasure for Osteoporosis?

The National Research Council's report entitled: A Strategy for Space Biology and Medical Science, highlighted several areas of fundamental scientific investigation which must be addressed to make long-term space exploration not only feasible, but safe. This "Goldberg Strategy," as well as several subsequent reports published by the NRC's Space Studies Board (e.g., Assessment of Programs in Space Biology and Medicine, Smith et. al., 1991), suggests that the principal hurdle to man's extended presence in space is the osteopenia which parallels reduced gravity. Ironically, the most significant risk to the skeleton may only be realized on return to normal gravitational fields, and full recovery of bone mass may never occur. Effective counter-measures to this microgravity induced bone loss are thus essential. Considering the similarities of space and aging induced osteopenia, an indisputable benefit of such a prophylaxis would be its potential as a treatment for the bone loss which plagues over 25 million people in the U.S. The osteogenic potential of mechanical strain is strongly frequency dependent, with sensitivity increasing up through at least 60 Hz (cycles per second). One hundred seconds per day of a 1 Hz cyclic loading will inhibit disuse osteopenia only if sufficient in magnitude to engender 1000 microstrain (mu(epsilon)) in the tissue. When loading is applied at 30 Hz, however, mechanical strains on the order of 5O mu(epsilon) (approx. 1% of the peak strains which occur in bone during vigorous functional activity), can stimulate bone formation in a duration dependent manner. In longer term animal studies, strains of less than 10 mu(epsilon), induced non-invasively via a whole body vibration, will stimulate bone formation on the surfaces of trabeculae, increase bone density, and improve strength. Finally, preliminary results from a double blind prospective clinical trial shows promise in inhibiting the bone loss which parallels the menopause. Based on these observations, we propose that these high frequency, low magnitude, mechanical strains effectively serve as a "surrogate" for musculoskeletal ground reaction forces, and thus represent an ideal countermeasure to the osteopenia which parallels microgravity conditions. The specific goal of this NASA funded work is to identify genes in bone upregulated by disuse, and to determine the efficacy of an osteogenic mechanical stimulus to downregulate their expression.

Rubin, C.

The Biomechanics of Exercise Countermeasures

The Penn State Zero-gravity Simulator (PSZS) is a device developed by the Center for Locomotion Studies (CELOS) to enable ground studies of exercise countermeasures for the bone loss that has been shown to occur during long-term exposure to zero gravity (0G). The PSZS simulates 0G exercise by providing a suspension system that holds an individual in a horizontal (supine) position above the floor in order to enable exercise on a wall-mounted treadmill. Due to this orientation, exercise performed in the PSZS is free of the force of -ravity in the direction that would normally contribute to ground reaction forces. In order for movements to be more similar to those in 0G, a constant force suspension of each segment (equal to the segment weight) is provided regardless of limb position. During the preliminary development of the PSZS, CELOS researchers also designed an optional gravity-replacement simulation feature for the PSZS. This feature was a prototype tethering system that consisted of a spring tension system to pull an exercising individual toward the treadmill. The immediate application of the tethering system was to be the provision of gravity-replacement loading so that exercise in 0G- and 1G-loading conditions could be compared, and the PSZS could then be used to evaluate exercise countermeasures for bone loss during space flight. This tethering system would also be a model for the further refinement of gravity-replacement systems provided for astronaut usage while performing prescribed exercise countermeasures for bone loss during long-term space flights.

Cavanagh, Peter R.

A Biomechanical Comparison of 1-G and Fully-Loaded Simulated Zero-Gravity Locomotion

Exercise will almost certainly play an integral part in minimizing the bone mineral loss and muscular atrophy that occur during spaceflight. It has been hypothesized that an effective exercise regimen can be developed to elicit loads on the lower extremities and require muscle actions which resemble those encountered on Earth. The Penn State Zero-Gravity Simulator (PSZS) is a device which suspends subjects horizontally from multiple latex cords, with each cord negating the weight of a limb segment. A treadmill mounted on the wall under the PSZS enables subjects to run in simulated 0G. Subjects wear a harness to which a number of springs, which provide a gravity replacement load, are connected. The opposite end of each spring is connected to the side of the treadmill. During exercise, astronauts currently wear a similar harness in which the spring tethering load pulls at both the waist and shoulders. Ground reaction forces, muscular activations, and joint angles of the left leg during overground, treadmill, and fully-loaded zero-gravity simulated (ZLS) locomotion were assessed in order to gain insight into the effectiveness of the exercise regimen used by NASA to prevent the muscular atrophy and bone demineralization which occur in weightlessness. There were three hypotheses to this research. It was hypothesized that there will be no differences in peak ground reaction forces and peak loading rates between overground gait and gait in the full body weight loaded conditions in the ZLS. A second hypothesis was that that there will be no differences in hip, knee, and ankle joint positions between walking or running overground, on a standard treadmill, and in full bodyweight loaded conditions in the ZLS. The third hypothesis was that the muscular activations, as a percentage of maximal voluntary contraction, will be similar between walking or running overground, on a standard treadmill, and in full body-weight loaded conditions in the ZLS.

McCrory, Jean L.

Biomechanical Evaluation of Russian BD-1 Treadmill during Non-Motorized Treadmill Locomotion in a Weightless Environment (KC-135)

Subjects are able to successfully perform locomotion exercise on the BD-1 treadmill in weightlessness. The BD-1 bungee system has limited adjustability and provides higher loading for small subjects and lower loading for larger subjects. Some subjects have difficulty reaching and maintaining higher speeds starting at around 14 km/h. The ground reaction force profile for BD-1 locomotion shows peak propulsive forces comparable to 1g, but the heel strike peak appears to be absent during running on the BD-1 in weightlessness. These observations have implications for exercise prescriptions for BD-1 treadmill use on-board ISS.

Schaffner, Grant

An Integrated Biomechanical Model for Microgravity-Induced Visual Impairment

When gravitational unloading occurs upon entry to space, astronauts experience a major shift in the distribution of their bodily fluids, with a net headward movement. Measurements have shown that intraocular pressure spikes, and there is a strong suspicion that intracranial pressure also rises. Some astronauts in both short- and long-duration spaceflight develop visual acuity changes, which may or may not reverse upon return to earth gravity. To date, of the 36 U.S. astronauts who have participated in long-duration space missions on the International Space Station, 15 crew members have developed minor to severe visual decrements and anatomical changes. These ophthalmic changes include hyperopic shift, optic nerve distension, optic disc edema, globe flattening, choroidal folds, and elevated cerebrospinal fluid pressure. In order to understand the physical mechanisms behind these phenomena, NASA is developing an integrated model that appropriately captures whole-body fluids transport through lumped-parameter models for the cerebrospinal and cardiovascular systems. This data feeds into a finite element model for the ocular globe and retrobulbar subarachnoid space through time-dependent boundary conditions. Although tissue models and finite element representations of the corneo-scleral shell, retina, choroid and optic nerve head have been integrated to study pathological conditions such as glaucoma, the retrobulbar subarachnoid space behind the eye has received much less attention. This presentation will describe the development and scientific foundation of our holistic model.

Nelson, Emily S.

Characterization of the Biomechanical Behavior of the Optic Nerve Sheath

A major priority in current space medicine research is to characterize the mechanisms in Visual Impairment and Intracranial Pressure (VIIP) syndrome, a group of ophthalmic changes that occur in some astronauts following long-duration spaceflight [1]. It is hypothesized that microgravity-induced cephalad fluid shifts lead to increases in intracranial pressure (ICP), which drives maladaptive remodeling of the optic nerve sheath (ONS). In this study, we investigated the effects of mechanical loading on the porcine ONS to better understand the mechanical response of the ONS to increased ICP.

fluid shift (biological)

Anthropometry and Biomechanics Facility Presentation to Open EVA Research Forum

NASA is required to accommodate individuals who fall within a 1st to 99th percentile range on a variety of critical dimensions. The hardware the crew interacts with must therefore be designed and verified to allow these selected individuals to complete critical mission tasks safely and at an optimal performance level. Until now, designers have been provided simpler univariate critical dimensional analyses. The multivariate characteristics of intra-individual and inter-individual size variation must be accounted for, since an individual who is 1st percentile in one body dimension will not be 1st percentile in all other dimensions. A more simplistic approach, assuming every measurement of an individual will fall within the same percentile range, can lead to a model that does not represent realistic members of the population. In other words, there is no '1st percentile female' or '99th percentile male', and designing for these unrealistic body types can lead to hardware issues down the road. Furthermore, due to budget considerations, designers are normally limited to providing only 1 size of a prototype suit, thus requiring other possible means to ensure that a given suit architecture would yield the necessary suit sizes to accommodate the entire user population. Fortunately, modeling tools can be used to more accurately model the types of human body sizes and shapes that will be encountered in a population. Anthropometry toolkits have been designed with a variety of capabilities, including grouping the population into clusters based on critical dimensions, providing percentile information given test subject measurements, and listing measurement ranges for critical dimensions in the 1st-99th percentile range. These toolkits can be combined with full body laser scans to allow designers to build human models that better represent the astronaut population. More recently, some rescaling and reposing capabilities have been developed, to allow reshaping of these static laser scans in more representative postures, such as an abducted shoulder. All of the hardware designed for use with the crew must be sized to accommodate the user population, but the interaction between subject size and hardware fit is complicated with multi-component, complex systems like a space suit. Again, prototype suits are normally only provided in a limited size range, and suited testing is an expensive endeavor; both of these factors limit the number and size of people who can be used to benchmark a spacesuit. However, modeling tools for assessing suit-human interaction can allow potential issues to be modeled and visualized. These types of modeling tools can be used for analysis of a larger combination of anthropometries and hardware types than could feasibly be done with actual human subjects and physical mockups.

Rajulu, Sudhakar