Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BETA SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of geometrical configuration of radioactive sources on radiation intensity in beta-voltaic nuclear battery system: A preliminary result

It is known that one main problem in the application of beta-voltaic nuclear battery system is its low efficiency. The efficiency of the beta-voltaic nuclear battery system mainly depends on three aspects: source of radioactive radiation, interface between materials in the system and process of converting electron-hole pair to electric current in the semiconductor material. In this work, we show the effect of geometrical configuration of radioactive sources on radiation intensity of beta-voltaic nuclear battery system.

07 ISOTOPE AND RADIATION SOURCES↗

The Nanofocus Endstation of the MINAXS Beamline of PETRA III

The Micro- and Nanofocus X-ray Scattering Beamline (MINAXS) of the new 3rd generation source PETRA III is equipped with two endstations, out of which the farthest from the high beta undulator source is designed to provide a high flux, monochromatic X-ray beam focused to a size in the order of 100 nmx100 nm routinely used for microdiffraction experiments (nanofocus endstation). This contribution presents an overview on the current status of the nanofocus endstation and outlines the to-be-used experimental setup.

43 PARTICLE ACCELERATORS↗

Neutrons, gamma rays, and beta particles interactions with IIaO films flown on Astro I and Astro II and comparison with IIaO flown on the get-away-special STS-7

The current requirements for the Laboratory for Astronomy and Solar Physics, sends rocket satellites and in the near future will involve flights in the shuttle to the upper reaches of the Earth's atmosphere where they will be subjected to the atomic particles and electromagnetic radiation produced by the Sun and other cosmic radiation. It is therefore appropriate to examine the effect of neutrons, gamma rays, beta particles, and X-rays on the film currently being used by the Laboratory for current and future research requirements. It is also hoped by examining these particles in their effect that we will have simulated the space environment of the rockets, satellites, and shuttles. Several samples of the IIaO film were exposed to a neutron howitzer with a source energy of approximately 106 neutrons/steradians. We exposed several samples of the film to a 10 second blast of neutrons in both metal and plastic containers which exhibited higher density readings which indicated the possibility of some secondary nuclear interactions between neutrons and the aluminum container. The plastic container showed some variations at the higher densities. Exposure of the samples of IIaO film to a neutron beam of approximately 10 neutrons per steradians for eight minutes produces approximately a 13% difference in the density readings of the dark density grids. It is not noticeable that at the lighter density grid the neutrons have minimal effects, but on a whole the trend of the eight minute exposed IIaO film density grids at the darker end had a 7.1% difference than the control. Further analysis is anticipated by increasing the exposure time. Two sets of film were exposed to a beta source in a plastic container. The beta source was placed at the bottom so that the cone of rays striking the film would be conical for a period of seven days. It was observed in the films, designated 4a and 4b, a dramatic increase in the grid densities had occurred. The attenuation of beta particles due to the presence of air were observed. The darker density grids, whose positions were the furthest from the beta source, displayed minimal fluctuations as compared with the control. It is suspected that the orientation of the film in the cansister with the beta source is the key factor responsible for the dramatic increases of the lighter density grids. Emulsions 3a and 3b exposed for a period of six days with the grid orientation reserved produced substantial differences in the darker grids as shown in the graphs. There is a great deal of fluctuations in this sample between the beta exposed density grids and the control density grids. The lighter density grids whose orientations were reversed displays minimal fluctuations due to the presence of this beta source and the attenuation that is taking place.

Hammond, Ernest C., Jr.↗

Investigation of space-charge effects in gaseous tritium as a source of distortions of the beta spectrum observed in the Troitsk neutrino-mass experiment

Results of searches for effects of space-charge accumulation in the gaseous tritium source in the Troitsk neutrino-mass experiment are presented. The broadening and the shift of the L3 line of conversion electrons in a {sup 83m}Kr gaseous source circulating together with tritium was investigated. The attained limit on the magnitude of fluctuations of the space-charge potential makes it possible to set a limit on the negative neutrino mass squared in the Troitsk neutrino-mass experiment (-0.8 < {delta}m{sub {nu}}{sup 2} {<=} 0 eV{sup 2}), a spurious effect associated with this potential. A statistically reliable shift of the position of the L3 line is discovered. This indicates that processes of of space-charge accumulation do indeed proceed in the source at a level that is significant for the future experiment Katrin.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of space-charge effects in gaseous tritium as a source of distortions of the beta spectrum observed in the Troitsk neutrino-mass experiment

Results of searches for effects of space-charge accumulation in the gaseous tritium source in the Troitsk neutrino-mass experiment are presented. The broadening and the shift of the L3 line of conversion electrons in a {sup 83m}Kr gaseous source circulating together with tritium was investigated. The attained limit on the magnitude of fluctuations of the space-charge potential makes it possible to set a limit on the negative neutrino mass squared in the Troitsk neutrino-mass experiment (-0.8 < {Delta}m{sub {nu}}{sup 2} {<=} 0 eV{sup 2}), a spurious effect associated with this potential. A statistically reliable shift of the position of the L3 line is discovered. This indicates that processes of of space-charge accumulation do indeed proceed in the source at a level that is significant for the future experiment Katrin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Betavoltaics with absorber layer containing coated scintillating particles

A beta-voltaic device made up of silica covered scintillating particles incorporated within an isotope absorbing layer to produce an improved power source. Lost beta particles are converted to UV light which is also converted to power in a beta-voltaic converter. The addition of the scintillating particles effectively increases the power efficiency of a BV device while maintaining the slim profile and smaller size of the power source. This arrangement makes possible implementation in space, defense, intelligence, medical implants, marine biology and other applications.

Hubbard, Lance R.↗

The Einstein observatory medium sensitivity survey - The quasars sample

A complete sample of X-ray-selected quasars and Seyfert galaxies extracted from the Einstein Observatory Medium Sensitivity Survey is described, and their physical characteristics are discussed. A Hubble constant of 50 km/s per Mpc and a Friedmann universe with a deceleration parameter of q(0)=0 are assumed throughout the survey, and the sample of X-ray sources was selected according to the following criteria: the significance of the detection exceeds a confidence level of 5 beta; the source is physically unrelated to the target of the IPC observation; and that the source is at a galactic latitude higher than 20 deg. The redshift and optical luminosity distributions of 55 Active Galactic Nuclei (AGNs) detected in the survey are discussed. A number flux relation for the different classes of extragalactic objects are analyzed in detail, using a Maximum Likelihood method and the assumption that the relation can be represented as a power law.

Gioia, I. M.↗

Offsite Source Recovery Program; High Activity Beta Gamma Removal, Transport and Disposition - 19663

The Department of Energy's (DOE) National Nuclear Security Administration's (NNSA) Office of Radiological Security's (ORS) Off-Site Source Recovery Program (OSRP) has been tasked with the removal and disposition of radioactive sealed sources in the interest of national security and public health and safety. It is the mission of the program to recover radioactive sources to prevent them from falling into the hands of individuals who would use this material for malicious intent. OSRP is a collaborative effort involving Los Alamos National Laboratory (LANL), Idaho National Laboratory (INL), and Lawrence Livermore National Laboratory (LLNL). At the inception of the program, Pu-239 was the only isotope acceptable for recovery. As a wider security scope developed, OSRP expanded its mission to include the recovery of other sources that posed a potential risk to national security, health, and safety. Starting in 2004, OSRP began recovering cesium and cobalt devices, largely from medical, research, and industrial facilities. These disused higher-activity devices present a burden to licensees in terms of security, and demand for OSRP's assistance in removing them has been high. Today, OSRP removes around 40 high-activity devices per year in support of domestic demand as well as ORS's Cesium Irradiator Replacement Project (CIRP). This represents an average of over 50,000 Ci of Cs-137 and Co-60 removed from the private sector each year for permanent disposition. A major component of this effort is the use of the proper shipping container to transport the devices. As a way to increase transportation capabilities ORS has developed two new Type B containers. The most recently completed of these containers, the 435-B, is currently certified to transport Gammators and Gammacell-1000, -3000, and -40 irradiators in an overpack configuration. This provides greater capacity and flexibility to safely and effectively transport these devices, for which acceptable shipping configurations had been previously limited. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Li+ alumino-silicate ion source development for the Neutralized Drift Compression Experiment (NDCX-II)

To heat targets to electron-volt temperatures for the study of warm dense matter with intense ion beams, low mass ions, such as lithium, have an energy loss peak (dE/dx) at a suitable kinetic energy. The Heavy Ion Fusion Sciences (HIFS) program at Lawrence Berkeley National Laboratory will carry out warm dense matter experiments using Li{sup +} ion beam with energy 1.2-4 MeV in order to achieve uniform heating up to 0.1-1 eV. The accelerator physics design of Neutralized Drift Compression Experiment (NDCX-II) has a pulse length at the ion source of about 0.5 {micro}s. Thus for producing 50 nC of beam charge, the required beam current is about 100 mA. Focusability requires a normalized (edge) emittance {approx}2 {pi}-mm-mrad. Here, lithium aluminosilicate ion sources, of {beta}-eucryptite, are being studied within the scope of NDCX-II construction. Several small (0.64 cm diameter) lithium aluminosilicate ion sources, on 70%-80% porous tungsten substrate, were operated in a pulsed mode. The distance between the source surface and the mid-plane of the extraction electrode (1 cm diameter aperture) was 1.48 cm. The source surface temperature was at 1220 C to 1300 C. A 5-6 {micro}s long beam pulsed was recorded by a Faraday cup (+300 V on the collector plate and -300 V on the suppressor ring). Figure 1 shows measured beam current density (J) vs. V{sup 3/2}. A space-charge limited beam density of {approx}1 mA/cm{sup 2} was measured at 1275 C temperature, after allowing a conditioning time of about {approx} 12 hours. Maximum emission limited beam current density of {ge} 1.8mA/cm{sup 2} was recorded at 1300 C with 10-kV extractions. Figure 2 shows the lifetime of two typical sources with space-charge limited beam current emission at a lower extraction voltage (1.75 kV) and at temperature of 1265 {+-} 7 C. These data demonstrate a constant, space-charge limited beam current for 20-50 hours. The lifetime of a source is determined by the loss of lithium from the alumino-silicate material either as ions or as neutral atoms. Our measurements suggest that for the low duty factor ({approx}10{sup -8}) required for NDCX-II, the lifetime of an emitter depends mostly on the duration that the emitter spends at elevated temperature, that is, at {ge} 1250 C. At this temperature, lithium loss is due mostly to neutral loss (not charged ion extraction). Extension of the lifetime of the source may be possible by lowering the temperature between beam pulses, when the idling time is sufficiently long between shots. The NDCX-II design seeks to operate the ion source at the maximum current density without running into heat management and lifetime problems. In preparation to fabricate a large (10.9 cm in diameter) source for the NDCXII experiment, recently a 7.6 cm diameter source has been fabricated. The method of fabrication of this larger source is similar to that of fabrication of a 6.3mm diameter source, except a longer furnace heating time was used due to mass differences. NDCX-II construction is in progress. Progress of lithium source study for NDCX-II is available in literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of commercial proton exchange membrane materials after exposure to beta and gamma radiation

Proton Exchange Membrane (PEM) type electrolysis cells have a potential use for tritium removal and heavy water upgrading. AECL is currently exposing various commercial PEM materials to both gamma (Cobalt-60 source) and beta (tritiated water) radiation to study the effects of radiation on these materials. This paper summarizes the testing methods and results that have been collected to date. The PEM materials that are or have been exposed to radiation are: Nafion 112, 212, 117 and 1110. Membrane characterization pre- and post- exposure consists of non-destructive inspection (FTIR, SEM/XPS), mechanical (tensile strength, percentage elongation, and modulus), electrical (resistance), or chemical (ion-exchange capacity - IEC). It has appeared that the best characterization techniques to compare exposed versus unexposed membranes were IEC, ultimate tensile strength and percent elongation. These testing techniques are easy and cheap to perform. The non-destructive tests, such as SEM and FTIR did not provide particularly useful information on radiation-induced degradation. Where changes in material properties were measured after radiation exposure, they would be expected to result in poorer cell performance. However, for modest γ-radiation exposure, all membranes showed a slight decrease in cell voltage (better performance). In contrast, the one β-radiation exposed membrane did show the expected increase in cell voltage. The counterintuitive trend for γ-radiation exposed membranes is not yet understood. Based on these preliminary results, it appears that γ- and β-radiation exposures have different effects.

07 ISOTOPE AND RADIATION SOURCES↗

Ophthalmic applicators: An overview of calibrations following the change to SI units

Since the NIST dose to water standard for {sup 90}Sr/{sup 90}Y ophthalmic applicators was introduced, numerous sources have undergone calibration either at NIST or at the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL). From 1997 to 2008, 222 of these beta-emitting sources were calibrated at the UWADCL, and prior reference source strength values were available for 149 of these sources. A survey of UWADCL ophthalmic applicator calibrations is presented here, demonstrating an average discrepancy of -19% with a standard deviation of {+-}16% between prior reference values and the NIST-traceable UWADCL absorbed dose to water calibrations. Values ranged from -49% to +42%.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-D-BRE-01: A Sr-90 Irradiation Device for the Study of Cutaneous Radiation Injury

Purpose: To determine dosimetric character for a custom-built Sr-90 beta irradiator designed for the study of Cutaneous Radiation Injury (CRI) in a porcine animal model. In the event of a radiological accident or terrorist event, Sr-90, a fission by-product, will likely be produced. CRI is a main concern due to the low energy and superficial penetration in tissue of beta particles from Sr-90. Seven 100 mCi plaque Sr-90 radiation sources within a custom-built irradiation device create a 40 mm diameter region of radiation-induced skin injury as part of a larger project to study the efficacy of a topical keratin-based product in CRI healing. Methods: A custom-built mobile irradiation device was designed and implemented for in vivo irradiations. Gafchromic™ EBT3 radiochromic film and a PTW Markus chamber type 23343 were utilized for dosimetric characterization of the beta fluence at the surface produced by this device. Films were used to assess 2-dimensional dose distribution and percent depth dose characteristics of the radiation field. Ion chamber measurements provided dose rate data within the field. Results: The radiation field produced by the irradiation device is homogeneous with high uniformity (∼5%) and symmetry (∼3%) with a steep dose fall-off with depth from the surface. Dose rates were determined to be 3.8 Gy/min and 3.3 Gy/min for film and ion chamber measurements, respectively. A dose rate of 3.4 Gy/min was used to calculate irradiation times for in vivo irradiations. Conclusion: The custom-built irradiation device enables the use of seven Sr-90 beta sources in an array to deliver a 40 mm diameter area of homogeneous skin dose with a dose rate that is useful for research purposes and clinically relevant for the induction of CRI. Doses of 36 and 42 Gy successfully produce Grade III CRI and are used in the study of the efficacy of KeraStat™. This project has been funded in whole or in part with Federal funds from the Biomedical Advanced Research and Development Authority, Office of the Assistant Secretary for Preparedness and Response, Office of the Secretary, Department of Health and Human Services, under Contract No. HHSO100201200007C.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-193: FMEA Severity Scores - Do We Really Know?

Purpose: Mycosis fungoides is a common form of cutaneous T-cell lymphoma which generally affects the skin. A typical course of treatment may include fractionated total skin electron beam therapy. Given the difficulties in uniformly irradiating some regions of the body and the need for frequent visits within the context of a fractionated protocol, this study investigated the feasibility of delivering the dose using form-fitting cloth which contained phosphorous-32 as a source for beta particle irradiation. Methods: A piece of fabric (0.97 g) consisting of a blend of spandex and flame retardant material impregnated with phosphorus-31 (2000 ppm) was bombarded with neutrons to produce phosphorus-32. The cloth was then laid flat and a stack of radiochromic film placed on top. Sheets of film and tissue equivalent plastic were layered to form a stack measuring a total of 1 cm thickness and remained sandwiched for 77.3 hr. Results: The initial activity of the activated cloth was 44 μCi of P-32. The absorbed dose was uniform within planes parallel to the cloth and exponentially dependent on depth, delivering 560cGy at 0.3mm and falling to 20cGy at 3mm. Conclusion: The total dose prescribed for a typical course of TSET for mycosis fungoides is 36Gy delivered over 9 weeks and is expected to treat to at least 5mm depth. Therefore, the P-32 impregnated cloth may not be clinically indicated to treat this disease given the unfavorable depth-dose characteristics. However, a major advantage of using form-fitting cloth is the uniformity with which the dose could be delivered over the skin in areas which are not flat. Increasing the distance between cloth and skin could improve the depth-dose characteristics.

07 ISOTOPE AND RADIATION SOURCES↗

A Multi-Layer Phoswich Radioxenon Detection System (7th Qtr Report), Reporting Period 10/01/07 - 12/31/07

Description of activities conducted this report period: (1) Electronics Development--To improve the overall performance of the two-channel digital pulse processor (DPP2), the PCB has been redesigned and the new printed board is now under assembly. The system is enhanced with two new fast ADCs from Analog Devices (AD9230-250), each with a sampling rate of 250 MHz and a resolution of 12 bits. The data bus uses a high performance Low Voltage Differential Signaling (LVDS) standard. The offset and gain of each channel are separately controlled digitally by the GUI software. (2) GUI Software Development--A GUI is being developed using the Python programming language. All functions from the preceding MATLAB code have been re-implemented including basic waveform readout, pulse shape discrimination, and plotting of energy spectra. In addition, the GUI can be used to control sampling runs based on the number of pulses captured, either in real or live time. Calibration coefficients and pulse shape discrimination boundaries can be changed on the fly so that the detector may be characterized experimentally. Plots generated by the GUI can be exported as graphic data. At present, the software has only been tested using one channel, pending availability of the new DPP board (DPP2). However, the functions have been written to allow easy expansion to two channels. (3) Light Collection Modeling--The XEPHWICH design has been modeled to determine its light capture efficiency. Research in the 7th quarter includes additional simulations representing significant increase in data resolution, well over an order of magnitude greater than previous simulations. The final data set represents approximately 11 billion visible photons divided equally among 110 thousand data points. A laboratory experiment is being designed and executed to experimentally determine light capture efficiency as a function of position within the scintillators. (4) Radioxenon Fission Source--We have designed and constructed a fission chamber to be used for the collection of radioxenon gases following neutron bombardment of HEU in the Oregon State University TRIGA reactor. The aluminum housing and all vacuum fittings have been assembled, awaiting an HEU transfer from PNNL. Students have worked closely with PNNL and OSU Radiation Safety personnel to facilitate transfer of the HEU. The OSU TRIGA Reactor Operations Committee has approved the experiment. (5) Spectral (beta) Recognition--Spectral identification by a neural network developed in our laboratory was compared to that of solvers of a linear system of equations. Data indicate that our neural network is capable of identifying three beta emission sources ({sup 14}C, {sup 36}Cl, and {sup 99}Tc) simultaneously with reliability to within 3%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flow Rate Measurement Using {sup 99m}Tc Radiotracer Method in a Pipe Installation

Flow rate is a significant parameter for managing processes in chemical processing plants and water processing facility. Accurate measurement of the flow rate allows engineers to monitor the delivery of process material, which in turn impacts a plant's capacity to produce their products. One of the available methods for determining the flow rate of a process material is by introducing a radiotracer to the system that mimics the material's flow pattern. In this study, a low activity Technetium-99m radioisotope was injected into a water piping setup and the 2'' x 2'' NaI (Tl) detectors were calibrated to detect spectrum peaks at specific points of the pipe installation. Using pulse velocity method, water flow rate was determined to be 11.3 litres per minute. For the sampling method, at different pump capacity, the flow rate was 15.0 litres per minute.

07 ISOTOPE AND RADIATION SOURCES↗

Instrument Efficiencies and ISO-7503 - 16525

The International Standard for the Evaluation of Surface Contamination provides guidance on evaluating surface contamination, and is used to document clearance of buildings, materials, and equipment. A key component of the guidance is the determination of instrument efficiency based on the 2-pi emission rate of a traceable radiation source. Many projects implement portions of this guidance or apply the guidance incorrectly. These errors generally result in an overestimate of the instrument efficiency, resulting in an underestimate of the activity being measured and overly optimistic estimates of detectability. A review of the recommendations for developing instrument efficiencies is provided, and the aspects of the guidance that are most often neglected are identified. The impact of failing to properly determine the instrument efficiency is demonstrated using experimental data. Data were collected using traceable alpha and beta radiation sources at multiple source-to-detector distances using gas-proportional and dual-phosphor detectors. The results of these measurements demonstrate the importance of proper implementation of the guidance for determining instrument efficiency and assist reviewers in identifying situations where the guidance was not properly implemented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗