Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

R & D of a Gas-Filled RF Beam Profile Monitor for Intense Neutrino Beam Experiments

We report the R&D of a novel radiation-robust hadron beam profile monitor based on a gas-filled RF cavity for intense neutrino beam experiments. An equivalent RF circuit model was made and simulated to optimize the RF parameter in a wide beam intensity range. As a result, the maximum acceptable beam intensity in the monitor is significantly increased by using a low-quality factor RF cavity. The plan for the demonstration test is set up to prepare for future neutrino beam experiments.

43 PARTICLE ACCELERATORS↗

Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid monitor for both beam position and tilt of pulsed high-current beams

A Hybrid beam monitor, integrated with both azimuthal and axial B-dot probes, was designed for simultaneous measurement of both beam position and beam angle for pulsed high-current beams at the same location in beam pipe. The output signals of axial B-dot probes were found to be mixed with signals caused by transverse position deviation. In order to eliminate the unwanted signals, an elimination method was developed and its feasibility tested on a 50-Ω coaxial line test stand. By this method, a waveform, shape-like to that of input current and proportional to the tilt angle, was simulated and processed by following integration step to achieve the tilt angle. The tests showed that the measurement error of displacement and tilt angle less than 0.3 mm and 1.5 mrad, respectively. The latter error could be reduced with improved probes by reducing the inductance of the axial B-dot probe, but the improvement reached a limit due to some unknown systemic mechanism.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electro-optic sampling beam position monitor for relativistic electron beams

Here, an electro-optic sampling beam position monitor for installation at the SLAC National Accelerator Laboratory FACET-II facility is described. Simulations of the detector signal were performed using realistic electron beam current profiles, demonstrating that this single-shot, non-destructive, compact detector is capable of resolving the relative transverse offset and longitudinal separation of an ultra-relativistic, two-bunch electron beam to order 1 μm and 10 fs, respectively. A design study was performed to optimize the detector’s response to the ultra-relativistic two-bunch electron beam utilized in plasma wakefield accelerator experiments. In addition, the expected sensitivity to beam tilt is studied for typical electron beams used in free electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Noise estimation of beam position monitors at RHIC

Beam position monitors (BPM) are used to record the average orbits and transverse turn-by-turn displacements of the beam centroid motion. The Relativistic Hadron Ion Collider (RHIC) has 160 BPMs for each plane in each of the Blue and Yellow rings: 72 dual-plane BPMs in the insertion regions (IR) and 176 single-plane modules in the arcs. Each BPM is able to acquire 1024 or 4096 consecutive turn-by-turn beam positions. Inevitably, there are broadband noisy signals in the turn-by-turn data due to BPM electronics as well as other sources. A detailed study of the BPM noise performance is critical for reliable optics measurement and beam dynamics analysis based on turn-by-turn data.

43 PARTICLE ACCELERATORS↗

A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic-Field Diffusion Effects in Beam Position Monitors I: Theory

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam position monitor for energy recovered linac beams

A method of determining the beam position in an energy recovered linac (ERL). The method makes use of in phase and quadrature (I/Q) demodulation techniques to separate the pickup signal generated by the electromagnetic fields generated by the first and second pass beam in the energy recovered linac. The method includes using analog or digital based I/Q demodulation techniques in order to measure the relative amplitude of the signals from a position sensitive beam pickup such as a button, strip line or microstripline beam position monitor.

47 OTHER INSTRUMENTATION↗

Progress on the development of the next generation x-ray beam position monitors at the advanced photon source

Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source (APS). The next generation XBPMs for high heat load front ends (HHL FEs) have been designed to meet these requirements by utilizing Cu K-edge x-ray fluorescence (XRF) from a pair of copper absorbers and have been installed at the front ends (FEs) of the APS. Commissioning data showed a significant performance improvement over the existing photoemission-based XBPMs. While a similar design concept can be applied for the canted undulator front ends, where two undulator beams are separated by 1.0-mrad, the lower beam power (< 10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from the diamond blades placed edge-on to the x-ray beam. A prototype of the Compton scattering XBPM system was installed at 24-ID-A in May 2015. In this report, the design and test results for XRF-based XBPM and Compton scattering based XBPM are presented. Ongoing research related to the development of the next generation XBPMs on thermal contact resistance of a joint between two solid bodies is also discussed.

43 PARTICLE ACCELERATORS↗

Thin conductive diamond films as beam intensity monitors for soft x-ray beamlines

Quantitative analysis of X-ray absorption and dichroism data requires knowledge of the beamline photon flux during the measurements. We show that thin conductive (B-doped) diamond thin films can be an alternative to the widely used gold meshes for monitoring the beam intensity of soft X-ray beamlines in situ. Limited by the carbon extended x-ray absorption fine structure oscillations, the diamond films become applicable beginning from about 600 eV photon energy, where the important transition metal edges and the rare-earth edges are found. The 100 nm and 250 nm thick free-standing diamond films were grown and tested against standard gold meshes in real-life dichroism experiments performed at beamline ID08 of the European Synchrotron Radiation Facility, Grenoble, France. Quantitative agreement was found between the two experimental data sets. The films feature an extremely high transmission of about 90% and, at the same time, yield a sufficiently strong and clean reference signal. Furthermore, the thin films do not affect the shape of the transmitted beam. X-rays passing mesh-type monitors are subject to diffraction effects, which widen the beam and become particularly disturbing for small beamsizes in the micrometer range.

36 MATERIALS SCIENCE↗

Emittance and lifetime measurement with damping wigglers

National Synchrotron Light Source II (NSLS-II) is a new third-generation storage ring light source at Brookhaven National Laboratory. The storage ring design calls for small horizontal emittance (<1 nm-rad) and diffraction-limited vertical emittance at 12 keV (8 pm-rad). Achieving low value of the beam size will enable novel user experiments with nm-range spatial and meV-energy resolution. The high-brightness NSLS-II lattice has been realized by implementing 30-cell double bend achromatic cells producing the horizontal emittance of 2 nm rad and then halving it further by using several Damping Wigglers (DWs). This paper is focused on characterization of the DW effects in the storage ring performance, namely, on reduction of the beam emittance, and corresponding changes in the energy spread and beam lifetime. The relevant beam parameters have been measured by the X-ray pinhole camera, beam position monitors, beam filling pattern monitor, and current transformers. In this paper, we compare the measured results of the beam performance with analytic estimates for the complement of the 3 DWs installed at the NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

Toward High-Intensity Ionization Chamber Beam Intensity Monitors in Switchyard

Beam intensity in the Switchyard beamlines is monitored by Secondary Emission Monitors ("SEMs") and Ionization Chambers ("ICs"). While less-expensive and easier to calibrate than SEMs, IC performance has typically degraded at higher beam intensities. This paper describes a proof-of-principle modification to a standard IC and associated electronics to increase the upper dynamic range of the system, showing that it is feasible to use ICs for high-intensity beamlines.

43 PARTICLE ACCELERATORS↗

Fermilab Switchyard Resonant Beam Position Monitor Electronics Upgrade Results

The readout electronics for the resonant beam position monitors (BPMs) in the Fermilab Switchyard (SY) have been upgraded, utilizing a low noise amplifier transition board and Fermilab designed digitizer boards. The stripline BPMs are estimated to have an average signal output of between -110 dBm and -80 dBm, with an esti-mated peak output of -70 dBm. The external resonant circuit is tuned to the SY machine frequency of 53.10348 MHz. Both the digitizer and transition boards have vari-able gain in order to accommodate the large dynamic range and irregularity of the resonant extraction spill. These BPMs will aid in auto-tuning of the SY beamline as well as enabling operators to monitor beam position through the spill.

43 PARTICLE ACCELERATORS↗

Design and Development of the PIP-II Stripline Beam Position Monitor

• Designed a stripline Beam Position Monitor (BPM) for the PIP-II accelerator to ensure precise proton beam alignment under ultra-high vacuum (UHV) conditions • Developed a mechanically robust and manufacturable assembly, including a cylindrical housing, electrodes, flange interfaces, and internal supports • Achieved high safety margins under pressure loading, using finite element analysis (FEA), while

Avalos Angel, Alejandro [Northern Illinois U.]↗