Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Optical design for the single crystal neutron diffractometer Pioneer

Pioneer is a single-crystal neutron diffractometer optimized for small-volume samples and weak signals at the Second Target Station at Oak Ridge National Laboratory. This paper presents the preliminary optical design progress, focusing on the rationale behind key design choices. It covers the T 0 and bandwidth disk choppers, guide and beam control system, incident-beam polarizer, scattering beam collimators, and additional strategies. The chopper locations are selected to maximize neutron transport while taking advantage of standardized shielding structures. To accommodate the maintenance shield, operational shutter, and polarizing V-cavity, the guide design includes significant gaps. When these optical components are moved out of the beam path, oversized collimators, rather than guides, will be translated in. Pioneer will utilize slit packages to control beam size and divergence and a translatable polarizing V-cavity. Absorbing panels are strategically placed near the end station to minimize background. An oscillating radial collimator, operating in a shift mode, will be used with the vertical cylindrical detector, while a fixed multi-cone collimator will be used with the bottom flat detector. In conclusion, these collimators will enable the detection of weak signals when complex sample environments are used.

47 OTHER INSTRUMENTATION↗

Phase shifter for antenna beam steering

Wide band Array Antenna operates in Ku-band (10.7-12.7 GHz) frequency composed of N×N radiating elements. This antenna aims at the reception of television satellite signals. The goal of this research is to provide better possibility of electronic beam control instead of manual or mechanical control, and design compact and low cost phase shifters to be inserted in the feeding network of this antenna. The electronic control of the phase shifter will allow the control of beam steering. The emphasis of this project will be done at the beginning on the design of a good phase shifter in Ku band. The aim of this research is to define, simulate, release and measure a continuous phase shifter. Better reflection loss, low transmission loss, low Cost of array antennas, large range of phase-shifter, phase flatness and bandwidth will be achieved by providing better gain.

42 ENGINEERING↗

Realization of an all optical exciton-polariton router

We report on the experimental realization of an all optical router for exciton-polaritons. This device is based on the design proposed by Flayac and Savenko [Appl. Phys. Lett. 103, 201105 (2013)], in which a zero-dimensional island is connected through tunnel barriers to two periodically modulated wires of different periods. Selective transmission of polaritons injected in the island, into either of the two wires, is achieved by tuning the energy of the island state across the band structure of the modulated wires. We demonstrate routing of ps polariton pulses using an optical control beam which controls the energy of the island quantum states, thanks to polariton-exciton interactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam characteristics in two different proton uniform scanning systems: A side-by-side comparison

Purpose: To compare clinically relevant dosimetric characteristics of proton therapy fields produced by two uniform scanning systems that have a number of similar hardware components but employ different techniques of beam spreading. Methods: This work compares two technologically distinct systems implementing a method of uniform scanning and layer stacking that has been developed independently at Indiana University (IU) and by Ion Beam Applications, S. A. (IBA). Clinically relevant dosimetric characteristics of fields produced by these systems are studied, such as beam range control, peak-to-entrance ratio (PER), lateral penumbra, field flatness, effective source position, precision of dose delivery at different gantry angles, etc. Results: Under comparable conditions, both systems controlled beam range with an accuracy of 0.5 mm and a precision of 0.1 mm. Compared to IBA, the IU system produced pristine peaks with a slightly higher PER (3.23 and 3.45, respectively) and smaller, symmetrical, lateral in-air penumbra of 1 mm compared to about 1.9/2.4 mm in the inplane/crossplane (IP/CP) directions for IBA. Large field flatness results in the IP/CP directions were similar: 3.0/2.4% for IU and 2.9/2.4% for IBA. The IU system featured a longer virtual source-to-isocenter position, which was the same for the IP and CP directions (237 cm), as opposed to 212/192 cm (IP/CP) for IBA. Dose delivery precision at different gantry angles was higher in the IBA system (0.5%) than in the IU system (1%). Conclusions: Each of the two uniform scanning systems considered in this work shows some attractive performance characteristics while having other features that can be further improved. Overall, radiation field characteristics of both systems meet their clinical specifications and show comparable results. Most of the differences observed between the two systems are clinically insignificant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-BRD-03: Analysis of Accelerator Generated Text Logs for Preemptive Maintenance

Purpose: To develop a model to analyze medical accelerator generated parameter and performance data that will provide an early warning of performance degradation and impending component failure. Methods: A robust 6 MV VMAT quality assurance treatment delivery was used to test the constancy of accelerator performance. The generated text log files were decoded and analyzed using statistical process control (SPC) methodology. The text file data is a single snapshot of energy specific and overall systems parameters. A total of 36 system parameters were monitored which include RF generation, electron gun control, energy control, beam uniformity control, DC voltage generation, and cooling systems. The parameters were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and the parameter/system specification. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: the value of 1 standard deviation from the mean operating parameter of 483 TB systems, a small fraction (≤ 5%) of the operating range, or a fraction of the minor fault deviation. Results: There were 34 parameters in which synthetic errors were introduced. There were 2 parameters (radial position steering coil, and positive 24V DC) in which the errors did not exceed the limit of the I/MR chart. The I chart limit was exceeded for all of the remaining parameters (94.2%). The MR chart limit was exceeded in 29 of the 32 parameters (85.3%) in which the I chart limit was exceeded. Conclusion: Statistical process control I/MR evaluation of text log file parameters may be effective in providing an early warning of performance degradation or component failure for digital medical accelerator systems. Research is Supported by Varian Medical Systems, Inc.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental study of the persistent current in RHIC superconducting dipole

The first goal [1] of this study is to reduce the high order magnetic component (mostly sextupole component) generated by persistent current in RHIC superconducting dipoles [2]. For Beam Energy Scan Phase II (BES-II) [3,4], reduction of lattice non-linearity is desirable for better beam control and beam lifetime. The sextupole component from RHIC dipole persistent current was too strong to be compensated at low operating current. The store length demonstrated in 2010 low energy operation at 3.85 GeV [5] was 10 minutes partially due to the lattice non -linearity. The measurement and compensation of lattice non-linearity were very difficult with such a short lifetime.

43 PARTICLE ACCELERATORS↗

Development and fabrication of a solar cell junction processing system

Experiments were completed which indicate that single-pulse, liquid-phase epitaxial regrowth is the optimum technique for pulsed electron beam annealing of ion implantation damage in silicon wafers. An electron beam which covers the entire area of the wafer was chosen for the solar cell processor. Beam control experiments to improve beam propagation and to test the concept of partial space charge and current neutralization were initiated. The electrical parameters of the pulsed electron beam subsystem were chosen on the basis of computer calculations and past experience in pulsed electron accelerator design and operation. The pulser, designated SPI-PULSE 7000, is designed to anneal 10 cm diameter silicon wafers at a rate of 30 per minute. The preliminary design of the major elements of the SPI-PULSE 7000 was completed, and the detailed design of many of the components begun. These elements include a capacitive energy store and charging system, an electron accelerator, a beam control system, a wafer handling system and pressure and vacuum assemblies.

Halvason, W.↗

New concepts in deployable beam structures

The design of deployable structures involves a complicated tradeoff of packaging efficiency, the overall mechanism associated with deploying and latching beam joints, and the requirements and complexity of the beam deployer/repacker. Three longeron deployable beams, controllable geometry beams, and hybrid deployable/erectable beam concepts are evaluated.

Rhodes, M. D.↗

Conceptual design of hollow electron lenses for beam halo control in the Large Hadron Collider

Collimation with hollow electron beams is a technique for halo control in high-power hadron beams. It is based on an electron beam (possibly pulsed or modulated in intensity) guided by strong axial magnetic fields which overlaps with the circulating beam in a short section of the ring. The concept was tested experimentally at the Fermilab Tevatron collider using a hollow electron gun installed in one of the Tevatron electron lenses. We are proposing a conceptual design for applying this technique to the Large Hadron Collider at CERN. A prototype hollow electron gun for the LHC was built and tested. The expected performance of the hollow electron beam collimator was based on Tevatron experiments and on numerical tracking simulations. Halo removal rates and enhancements of halo diffusivity were estimated as a function of beam and lattice parameters. Proton beam core lifetimes and emittance growth rates were checked to ensure that undesired effects were suppressed. Hardware specifications were based on the Tevatron devices and on preliminary engineering integration studies in the LHC machine. Required resources and a possible timeline were also outlined, together with a brief discussion of alternative halo-removal schemes and of other possible uses of electron lenses to improve the performance of the LHC.

43 PARTICLE ACCELERATORS↗

Effect of actuator dynamics on control of beam flexure during nonlinear slew of SCOLE model

The effect of actuator dynamics on the control of beam flexure during nonlinear slewing of the SCOLE model is discussed. Two aspects of physical limitations on the regulation of beam flexure are similated, i.e., (1) a one foot travel limitation of displacement of proof-mass actuators; and (2) a time delay of 0.1 secs. in application of controls. The goal was to assess the magnitude of induced errors and, comparing the results to the ideal, and to determine how much flexure there is during slew and settling.

Fisher, Shalom↗

Beam current controller for laser ion source

The present invention relates to the design and use of an ion source with a rapid beam current controller for experimental and medicinal purposes. More particularly, the present invention relates to the design and use of a laser ion source with a magnetic field applied to confine a plasma flux caused by laser ablation.

42 ENGINEERING↗

Angular dependence of the transverse Raman scattering in KDP and DKDP in geometries suitable for beam polarization control

The angular dependance of the transverse Raman scattering in potassium dihydrogen phosphate (KDP) and its deuterated analogue (DKDP) for the entire range of crystal configurations suitable for laser beam polarization control has been investigated via experimental and modeling tools. This work was made possible by simultaneously rotating a spherical sample and the pump polarization to effectively measure the angular dependance of the transverse Raman signal in 360°. This novel method, which is applicable for the investigation of the Raman scattering in optically anisotropic materials, demonstrates that the spontaneous Raman scattering signal exhibits strong angular dependence that is modulated by depolarization and polarization rotation effects generated as the Raman signal traverses the material due to its birefringence. The results show that the total signal generated by the pump beam is the sum of the signals generated by the two components that have polarization parallel and orthogonal to the optic axis. The peak signal intensity, which is of importance for high-power laser applications, depends on the orientation of the optic axis and can vary by a factor of about 2. The excellent agreement between experimental data and modeling results validates the associated models and enables one to consider optimal crystal cut designs for specific applications.

47 OTHER INSTRUMENTATION↗

Statistics of scattered photons from a driven three-level emitter in 1D open space

We derive the statistics of scattered photons from a Λ- or ladder-type three-level emitter (3LE) embedded in a 1D open waveguide. The weak probe photons in the waveguide are coupled to one of the two allowed transitions of the 3LE, and the other transition is driven by a control beam. This system shows electromagnetically induced transparency (EIT) which is accompanied with the Autler-Townes splitting (ATS) at a strong driving by the control beam, and some of these effects have been observed recently. We show that the nature of second-order coherence of the transmitted probe photons near two-photon resonance changes from bunching to antibunching to constant as strength of the control beam is ramped up from zero to a higher value where the ATS appears.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new experiment to investigate the origin of optical activity using a low energy positron beam of controlled helicity

Previous experiments undertaken in search of a correlation between the origin of optical activity in biological molecules and the helicity of beta particles emitted in nuclear beta decay have not provided any useful results. A description is presented of an experiment in which a low energy polarized positron beam of controlled helicity interacts with an optically active material to form positronium in vacuum. Advantages of the current study compared to the previous experiments are mainly related to a much greater sensitivity. Initially, it will be possible to detect a helicity-dependent asymmetry in triplet positronium formation of 1 part in 10,000. Improvements to better than 1 part in 100,000 should be attainable.

Gidley, D. W.↗

Optical technology for spacecraft antennas

The issues involved in the design and implementation of high-speed fiberoptic distribution networks for spacecraft antennas are examined. The phased array antennas and antenna remoting are considered. The system requirements for these two generic system types are summarized, and their architectures are described. Optical beamforming of phased arrays is discussed, including beam control at the T/R module level, optical beam control on the fiber optic distribution network, and optical beamforming in free space.

Herczfeld, P. R.↗

Ultra-fast transverse beam orbit control in LCLS copper linac. Part I

We report current and future experiments at LCLS require x-ray pulse trains of variable time separation on the nanosecond scale. For instance, the cavity-based XFEL (CBXFEL) will use up to 4 pulses separated by 218.5 ns, the X-ray Laser Oscillator (XLO) will use 15 to 25 ns spaced pulses, and the Matter under Extreme Conditions (MEC) experiments use pulse trains separated by 5 nanoseconds or less. In this paper, we demonstrate an ultra-fast e-beam trajectory control method based on transverse electro-magnetic (TEM) striplines and state-of-the-art power sources, to enhance LCLS operations in these regimes.

47 OTHER INSTRUMENTATION↗

Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron

The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of a beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗