Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Atomic techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Laser-excitation technique for the measurement of absolute transition probabilities of weak atomic lines

A new technique is presented for the measurement of transition probabilities for weak allowed, intersystem, and forbidden lines. The method exploits the fact that oscillator strength is proportional to the number of stimulated absorptions and emissions produced by a narrow-band laser pulse of known energy which is in resonance with an atomic transition. The method is tested for a particular transition of Mg I with a known oscillator strength value and of appropriate magnitude. The number densities are measured using a Mach-Zehnder interferometer and the hook method for the lower level population and by measuring an absorption-equivalent width for the other. The apparatus consisted of a high-power tunable laser and a magnesium oven to produce excited Mg vapor, and a laser-plasma background continuum. The results are in good agreement with theoretical and other experimental data.

Kwong, H. S.↗

A laser-based sizing/velocimetry technique to investigate the secondary atomization of aluminum gel propellants

A laser-based, forward-scatter diagnostic technique, employing a single laser sheet, has been developed to simultaneously measure the size and velocity of individual 10-150 micron droplets in a dilute polydisperse droplet stream (less than 1000 particles/cc) and to detect the presence of burning aluminum in these same droplets. Spectral emission from aluminum vapor in the 390-400 nm wavelength region is used as an indication of burning aluminum. The technique utilizes a 4-mm uniformly illuminated probe volume, eliminating trajectory-dependent particle sizing and size-dependent system detection bias. Particle sizing is based on a correlation of particle size with near-forward scattered light intensity. Calculations show average particle sizing variation to be within 3.5% over the expected range of refractive indices. Calibrations using a range of optical pinholes (10-100 micron) were used to verify the above sizing correlation.

Mueller, D. C.↗

Machine learning in analytical spectroscopy for nuclear diagnostics [Invited]

Analytical spectroscopy methods have shown many possible uses for nuclear material diagnostics and measurements in recent studies. In particular, the application potential for various atomic spectroscopy techniques is uniquely diverse and generates interest across a wide range of nuclear science areas. Over the last decade, techniques such as laser-induced breakdown spectroscopy, Raman spectroscopy, and x-ray fluorescence spectroscopy have yielded considerable improvements in the diagnostic analysis of nuclear materials, especially with machine learning implementations. These techniques have been applied for analytical solutions to problems concerning nuclear forensics, nuclear fuel manufacturing, nuclear fuel quality control, and general diagnostic analysis of nuclear materials. The data yielded from atomic spectroscopy methods provide innovative solutions to problems surrounding the characterization of nuclear materials, particularly for compounds with complex chemistry. Implementing these optical spectroscopy techniques can provide comprehensive new insights into the chemical analysis of nuclear materials. In particular, recent advances coupling machine learning methods to the processing of atomic emission spectra have yielded novel, robust solutions for nuclear material characterization. This review paper will provide a summation of several of these recent advances and will discuss key experimental studies that have advanced the use of analytical atomic spectroscopy techniques as active tools for nuclear diagnostic measurements.

Rao, Ashwin P. (ORCID:0000000319312568)↗

Interfacial oxide and other species in trimethylaluminum-pretreated atomic layer deposition-Al 2 O 3 /GaN characterized by sputter-assisted ToF-SIMS

Deposition techniques, like atomic layer deposition (ALD), are used to form high-quality dielectrics for GaN-based metal–oxide–semiconductor (MOS) gate structures due to the lack of a reliable thermal oxide in GaN. Moreover, interfacial GaO x from pre-existing native oxides is thought to adversely impact channel carrier dynamics and induce undesired threshold voltage shifts in GaN-based MOS gate structures. Exposure of the GaN surface to the trimethylaluminum (TMA) precursor prior to standard alumina ALD decreases the native oxide layer on GaN, but the extent of chemical modification has not been well studied in the context of interface composition in a MOS gate structure. Herein, we compare annealed 55 nm Al 2 O 3 dielectric films on GaN grown using either a water-first ALD process or a process including sequential pulses of TMA immediately before the initiation of Al 2 O 3 ALD. Time-of-Flight Secondary Ion Mass Spectrometry measures differences in the interfacial GaO x content between each ALD film. Here, it also detects surface contaminant species like Si, F, S, and C. Furthermore, we report the formation of an AlN species at the Al 2 O 3 /GaN interface, which is more prominent for the film grown using the TMA pre-pulse step. In general, this work demonstrates that the TMA pre-pulse step is an effective strategy for cleaning substrate surfaces prior to ALD.

Atomic layer deposition↗

Surface conversion techniques for low energy neutral atom imagers

This investigation has focused on development of key technology elements for low energy neutral atom imaging. More specifically, we have investigated the conversion of low energy neutral atoms to negatively charged ions upon reflection from specially prepared surfaces. This 'surface conversion' technique appears to offer a unique capability of detecting, and thus imaging, neutral atoms at energies of 0.01 - 1 keV with high enough efficiencies to make practical its application to low energy neutral atom imaging in space. Such imaging offers the opportunity to obtain the first instantaneous global maps of macroscopic plasma features and their temporal variation. Through previous in situ plasma measurements, we have a statistical picture of large scale morphology and local measurements of dynamic processes. However, with in situ techniques it is impossible to characterize or understand many of the global plasma transport and energization processes. A series of global plasma images would greatly advance our understanding of these processes and would provide the context for interpreting previous and future in situ measurements. Fast neutral atoms, created from ions that are neutralized in collisions with exospheric neutrals, offer the means for remotely imaging plasma populations. Energy and mass analysis of these neutrals provides critical information about the source plasma distribution. The flux of neutral atoms available for imaging depends upon a convolution of the ambient plasma distribution with the charge exchange cross section for the background neutral population. Some of the highest signals are at relatively low energies (well below 1 keV). This energy range also includes some of the most important plasma populations to be imaged, for example the base of the cleft ion fountain.

Quinn, J. M.↗

Continuum ionization transition probabilities of atomic oxygen

The technique of photoelectron spectroscopy was employed in the investigation. Atomic oxygen was produced in a microwave discharge operating at a power of 40 W and at a pressure of approximately 20 mtorr. The photoelectron spectrum of the oxygen with and without the discharge is shown. The atomic states can be clearly seen. In connection with the measurement of the probability for transitions into the various ionic states, the analyzer collection efficiency was determined as a function of electron energy.

Samson, J. A. R.↗

Impact of krypton irradiation on a single crystal tungsten: Multi-modal X-ray imaging study

Understanding microstructural and strain evolutions induced by noble gas production in the nuclear fuel matrix or plasma-facing materials is crucial for designing next generation nuclear reactors, as they are responsible for volumetric swelling and catastrophic failure. In this paper we describe a multimodal approach combining synchrotron-based nanoscale X-ray imaging techniques with atomic-scale electron microscopy techniques for mapping chemical composition, morphology and lattice distortion in a single crystal W induced by Kr irradiation. We report that Kr-irradiated single crystal W undergoes surface deformation, forming Kr containing cavities. Furthermore, positive strain fields are observed in Kr-irradiated regions, which lead to compression of underlying W matrix.

36 MATERIALS SCIENCE↗

Stabilization of Cu 2 O through Site-Selective Formation of a Co 1 Cu Hybrid Single-Atom Catalyst

Single-atom catalysts (SACs) consist of a low coverage of isolated metal atoms dispersed on a metal substrate, called single-atom alloys (SAAs), or alternatively single metal atoms coordinated to oxygen atoms on an oxide support. We present the synthesis of a new type of Co 1 Cu SAC centers on a Cu 2 O(111) support by means of a site-selective atomic layer deposition technique. Isolated metallic Co atoms selectively coordinate to the native oxygen vacancy sites (Cu sites) of the reconstructed Cu 2 O(111) surface, forming a Co 1 Cu SAA with no direct Co–O x bonds. The centers, here referred to as Co 1 Cu hybrid SACs, are found to stabilize the active Cu + sites of the low-cost Cu 2 O catalyst that otherwise is prone to deactivation under reaction conditions. The stability of the Cu 2 O(111) surface was investigated by synchrotron radiation-based ambient-pressure X-ray photoelectron spectroscopy under reducing CO environment. The structure and reduction reaction are modeled by density functional theory calculations, in good agreement with experimental results.

36 MATERIALS SCIENCE↗

In Situ Solid Particle Generator

Particle seeding is a key diagnostic component of filter testing and flow imaging techniques. Typical particle generators rely on pressurized air or gas sources to propel the particles into the flow field. Other techniques involve liquid droplet atomizers. These conventional techniques have drawbacks that include challenging access to the flow field, flow and pressure disturbances to the investigated flow, and they are prohibitive in high-temperature, non-standard, extreme, and closed-system flow conditions and environments. In this concept, the particles are supplied directly within a flow environment. A particle sample cartridge containing the particles is positioned somewhere inside the flow field. The particles are ejected into the flow by mechanical brush/wiper feeding and sieving that takes place within the cartridge chamber. Some aspects of this concept are based on established material handling techniques, but they have not been used previously in the current configuration, in combination with flow seeding concepts, and in the current operational mode. Unlike other particle generation methods, this concept has control over the particle size range ejected, breaks up agglomerates, and is gravity-independent. This makes this device useful for testing in microgravity environments.

Agui, Juan H.↗

Methods to Create Novel La 2- x Sr x CuO 4 Devices with Multiple Atomically Sharp Interfaces

We present methods to create devices that utilize the high-temperature superconductor La 2-x Sr x CuO 4 grown by atomic layer-by-layer molecular beam epitaxy (ALL-MBE). The ALL-MBE synthesis technique provides atomically precise interfaces necessary for the tunnel junctions, Josephson junctions, and dyon detection devices that will be considered. A series of microfabrication processing steps using established techniques are given for each device, and their details are discussed. These procedures are easily extended to generate more complex designs and could be suitable for a wider variety of materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonequilibrium in a low power arcjet nozzle

Emission spectroscopy measurements were made of the plasma flow inside the nozzle of a 1 kW class arcjet thruster. The thruster propellant was a hydrogen-nitrogen mixture used to simulate fully decomposed hydrazine. The 0.25 mm diameter holes were drilled into the diverging section of the tungsten thruster nozzle to provide optical access to the internal flow. Atomic electron excitation, vibrational, and rotational temperatures were determined for the expanding plasma using relative line intensity techniques. The atomic excitation temperatures decreased from 18,000K at a location 3 mm downstream of the constrictor to 9,000K at a location 9 mm from the constrictor, while the molecular vibrational and rotational temperatures decreased from 6,500K to 2,500K and from 8,000K to 3,000K, respectively, between the same locations. The electron density measured using hydrogen H line Stark broadening decreased from about 10(exp 15) cm(-3) to about 2 times 10(exp 14) cm(-3) during the expansion. The results show that the plasma is highly nonequilibrium throughout the nozzle, with most relaxation times equal or exceeding the particle residence time.

Zube, Dieter M.↗

Cleaning of Fire Damaged Watercolor and Textiles Using Atomic Oxygen

A noncontact technique is described that uses atomic oxygen generated under low pressure in the presence of nitrogen to remove soot from the surface of a test watercolor panel and strips of cotton, wool and silk. The process, which involves surface oxidation, permits control of the amount of surface material removed. The effectiveness of soot removal from test panels of six basic watercolors (alizarin crimson, burnt sienna, lemon yellow, yellow ochre, cerulean blue and ultramarine blue) and strips of colored cotton, wool and silk was measured using reflectance spectroscopy. The atomic oxygen removed soot effectively from the treated areas and enabled partial recovery of charred watercolors. However, overexposure can result in removal of sizing, bleaching, and weakening of the structure. With the proper precautions, atomic oxygen treatment appears to have great potential to salvage heavily smoke damaged artworks which were previously considered unrestorable.

Rutledge, Sharon K.↗

Recirculation of Laser Power in an Atomic Fountain

A new technique for laser-cooling atoms in a cesium atomic fountain frequency standard relies on recirculation of laser light through the atom-collection region of the fountain. The recirculation, accomplished by means of reflections from multiple fixed beam-splitter cubes, is such that each of two laser beams makes three passes. As described below, this recirculation scheme offers several advantages over prior designs, including simplification of the laser system, greater optical power throughput, fewer optical and electrical connections, and simplification of beam power balancing. A typical laser-cooled cesium fountain requires the use of six laser beams arranged as three orthogonal pairs of counter-propagating beams to decelerate the atoms and hold them in a three-dimensional optical trap in vacuum. Typically, these trapping/cooling beams are linearly polarized and are positioned and oriented so that (1) counter-propagating beams in each pair have opposite linear polarizations and (2) three of the six orthogonal beams have the sum of their propagation directions pointing up, while the other three have the sum of their propagation directions pointing down. In a typical prior design, two lasers are used - one to generate the three "up" beams, the other to generate the three "down" beams. For this purpose, the output of each laser is split three ways, then the resulting six beams are delivered to the vacuum system, independently of each other, via optical fibers. The present recirculating design also requires two lasers, but the beams are not split before delivery. Instead, only one "up" beam and one oppositely polarized "down" beam are delivered to the vacuum system, and each of these beams is sent through the collection region three times. The polarization of each beam on each pass through the collection region is set up to yield the same combination of polarization and propagation directions as described above. In comparison with the prior design, the present recirculating design utilizes the available laser light more efficiently, making it possible to trap more atoms at a given laser power or the same number of atoms at a lower laser power. The present design is also simpler in that it requires fewer optical fibers, fiber couplings, and collimators, and fewer photodiodes for monitoring beam powers. Additionally, the present design alleviates the difficulty of maintaining constant ratios among power levels of the beams within each "up" or "down" triplet.

Enzer, Daphna G.↗

Generation of a Cold Atom Beam from a Pyramidal Magneto-Optical Trap

Techniques to generate cold atom beams are of great interest in a variety of applications, from atomic frequency standards and atom optics to experimental studies of Bose-Einstein condensation. Cold atom beams have been produced by slowing thermal atomic beams using the Zeeman-slowing technique or chirped lasers, or using laser-cooling techniques to extract a slow atomic beam from the background gas in a low-pressure vapor cell. These laser-cooling techniques include "atomic funnels" or two-dimensional magneto-optical traps, as well as a variation of the conventional vapor cell magneto-optical trap called the "low-velocity intense source" (LVIS). Variations of the LVIS have been realized with unique trap geometries such as conical or pyramidal mirror traps. The present work implements a simple and robust design based on the pyramidal trap geometry and allows use of a single large diameter (<less than or = 20 cm) laser beam to obtain large capture rates of atoms from the background vapor. The four 45 deg mirrors are truncated just before the apex of the pyramid, and the 1 sq cm region at the center of the incident laser beam is retro-reflected by lambda /4 plate with a high-reflectance gold coating on the second surface. A small (1 mm diameter) hole in this retro-optic forms an extraction column for the atoms while maintaining a low conductance between the source region and an adjacent UHV chamber.

Kohel, J.↗

Nonequilibrium in a low power arcjet nozzle

Emission spectroscopy measurements were made of the plasma flow inside the nozzle of a 1-kW-class arcjet thruster. The thruster propellant was a hydrogen-nitrogen mixture used to simulate fully decomposed hydrazine. Atomic electron-excitation, vibrational, and rotational temperatures were determined for the expanding plasma using relative line intensity techniques. The atomic excitation temperature decreased from 18,000 K at a location 3 mm downstream of the constrictor to 9000 K at a location 9 mm from the constrictor, while the molecular vibrational and rotational temperatures decreased from 6500 K to 2500 K and from 8000 K to 3000 K, respectively, between the same locations. The electron density, measured using hydrogen H-beta line Stark broadening, decreased from about 10 to the 15th cu cm to about 2 x 10 to the 14th cu cm during the expansion. The results show that the plasma is highly nonequilibrium throughout the nozzle, with most relaxation times equal or exceeding the particle residence time.

Myers, Roger M.↗

Continuum ionization transition probabilities of atomic oxygen

The technique of photoelectron spectroscopy was used to obtain the relative continuum transition probabilities of atomic oxygen at 584 A for transitions from 3P ground state into the 4S, D2, and P2 states of the ion. Transition probability ratios for the D2 and P2 states relative to the S4 state of the ion are 1.57 + or - 0.14 and 0.82 + or - 0.07, respectively. In addition, transitions from excited O2(a 1 Delta g) state into the O2(+)(2 Phi u and 2 Delta g) were observed. The adiabatic ionization potential of O2(+)(2 Delta g) was measured as 18.803 + or - 0.006 eV.

Samson, J. R.↗

Direct Observation of Twin van der Waals Molecular Chains

The van der Waals (vdW) assemblies are the most common structures of materials. However, directly mapping intermolecular electron clouds of a vdW assembly has never been obtained, even though the intramolecular electron clouds were visualized by atomic-resolution techniques. In this report, we unprecedently mapped the intermolecular electron cloud of the assembles of ethanol molecules via ethyl groups with noncontact atomic force microscopy at 5 K, leading to the first visualization of vdW molecular chains, in which ethanol molecules assemble into twin vdW molecular chains in a reverse parallel configuration on Ag(111) plane. Furthermore, spontaneous order-disorder transitions in the chain were dynamically observed, suggesting its unusual properties different from 2D vdW materials. In conclusion, these findings provide an "eye" to see the atomic world of vdW materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗