EVSE Characterization

NextGen Profiles' EVSE characterization efforts explored performance variability in production EVSE through the use of EV emulation equipment and assessed how different operational conditions influence charging behavior. Data were collected at a frequency of 10 Hz from both the EV emulator and EVSE during each charge session and stored in a time-series database for further analysis. As part of the NextGen Profiles project, characterization of high-power EVSE was performed on both conductive and wireless charging infrastructure; however, only conductive charging data are currently included in this repository. This EVSE characterization was performed over a range of DC output currents and voltages, covering both nominal and off-nominal test conditions. This EVSE characterization dataset includes high-power charging data from two types of 350-kW-capable EVSE using liquid-cooled Combined Charging System-1 (CCS1, North American version) cables and connectors. To protect confidentiality, all EVSE metadata are anonymized, and the publicly released datasets are metered at 10-Hz frequency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fleet Utilization

A key goal of NextGen Profiles' fleet utilization study was to conduct a comprehensive, strategic, and standardized assessment of the operational behavior and utilization patterns across EV and EVSE production-ready fleets. These data-driven insights were intended to inform current fleet management strategies and support future infrastructure planning, ensuring the effective adoption and adaptation of the growing EV fleet market. The study applied a series of metrics defined in NextGen Profiles to evaluate diverse fleet operations across various use cases, emphasizing trends in charging, routing, and other critical behaviors. The fleet utilization dataset includes these three sets of metrics from 17 EV fleets, each consisting of a wide range of vehicle types and operational categories, as well as two EVSE fleets. Data were collected from a variety of sources and reformatted into a unified structure before metric computation, ensuring consistency and comparability across all fleets. To protect confidentiality, all fleet metadata are anonymized, and the publicly released metric datasets are aggregated to an hourly cadence.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chelation Modeling of a Plutonium-238 Inhalation Incident Treated with Delayed DTPA

This work describes an analysis, using a previously established chelation model, of the bioassay data collected from a worker who received delayed chelation therapy following a plutonium-238 inhalation. The details of the case have already been described in two publications. The individual was treated with Ca-DTPA via multiple intravenous injections and then nebulizations beginning several months after the intake and continuing for four years. The exact date and circumstances of the intake are unknown. However, interviews with the worker suggested that the intake occurred via inhalation of a soluble plutonium compound. The worker provided daily urine and fecal bioassay samples throughout the chelation treatment protocol, including samples collected before, during, and after the administration of Ca-DTPA. Unlike the previous two publications presenting this case, the current analysis explicitly models the combined biokinetics of the plutonium-DTPA chelate. Further, using the previously established chelation model, it was possible to fit the data through optimizing only the intake (day and magnitude), solubility, and absorbed fraction of nebulized Ca-DTPA. This work supports the hypothesis that the efficacy of the delayed chelation treatment observed in this case results mainly from chelation of cell-internalized plutonium by Ca-DTPA (intracellular chelation). It also demonstrates the validity of the previously established chelation model. As the bioassay data were modified to ensure data anonymization, the calculation of the “true” committed effective dose was not possible. However, the treatment-induced dose inhibition (in percentage) was calculated.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

AmeriFlux US-EA5 Uvalde Ranch Mesquite Woodland

This is the AmeriFlux version of the carbon flux data for the site US-EA5 Uvalde Ranch Mesquite Woodland. Site Description - This tower was located on a private ranch located approximately 25 km northwest of Uvalde, TX. The tower was installed on a trailer and situated amongst primarily mesquite trees. The lat/long provided here is approximate as the landowner wishes to maintain anonymity.

McKinney, Tyson↗

AmeriFlux FLUXNET-1F US-EA5 Uvalde Ranch Mesquite Woodland

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-EA5 Uvalde Ranch Mesquite Woodland. This is the FLUXNET version of the carbon flux data for the site US-EA5 Uvalde Ranch Mesquite Woodland produced by applying the standard ONEFlux (1F) software. Site Description - This tower was located on a private ranch located approximately 25 km northwest of Uvalde, TX. The tower was installed on a trailer and situated amongst primarily mesquite trees. The lat/long provided here is approximate as the landowner wishes to maintain anonymity.

McKinney, Tyson [The University of Texas at Austin↗

Neighborhood Keeper Program Review

Dragos provided INL access to their Neighborhood Keeper platform, which contains simulated data, sample reports given to utilities, and access to anonymized program data that is sent from utilities to the cloud. Dragos has specifically asked INL to review the available data and respond to the following questions: 1) What detections or combinations of detections are most useful? 2) What additional analysis would benefit the electricity subsector? 3) How could Neighborhood Keeper reporting be modified to benefit the electricity subsector? 4) What lessons learned from the Cybersecurity for the Operational Technology Environment (CyOTE) program could be provided? 5) Based on INL’s experience with utilities, are there lessons learned about data sharing that could be provided? 6) Are there recommendations that could benefit the electricity subsector?

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of BQ-9000 Biodiesel Properties for 2020 (CRADA CRD-15-593)

Biodiesel producers in the United States and Canada can voluntarily participate in the industry's BQ-9000 quality assurance program. This is the fourth in a series of reports documenting biodiesel quality from participating producers. Participants in the BQ-9000 program were requested to voluntarily provide data to a third-party team. This team anonymized and randomized the data prior to providing to the National Renewable Energy Laboratory (NREL) for analysis and reporting. The critical quality parameters analyzed are: sodium and potassium, calcium and magnesium, phosphorus, flash point and alcohol control, water and sediment, cloud point, acid number, free and total glycerin, monoglycerides, sulfur, oxidation stability, and cold soak filterability test (CSFT). The statistical analysis for these parameters is presented in Table ES-1.

09 BIOMASS FUELS↗

Foundations of Rigorous Cyber Experimentation

This report presents the results of the “Foundations of Rigorous Cyber Experimentation” (FORCE) Laboratory Directed Research and Development (LDRD) project. This project is a companion project to the “Science and Engineering of Cyber security through Uncertainty quantification and Rigorous Experimentation” (SECURE) Grand Challenge LDRD project. This project leverages the offline, controlled nature of cyber experimentation technologies in general, and emulation testbeds in particular, to assess how uncertainties in network conditions affect uncertainties in key metrics. We conduct extensive experimentation using a Firewheel emulation-based cyber testbed model of Invisible Internet Project (I2P) networks to understand a de-anonymization attack formerly presented in the literature. Our goals in this analysis are to see if we can leverage emulation testbeds to produce reliably repeatable experimental networks at scale, identify significant parameters influencing experimental results, replicate the previous results, quantify uncertainty associated with the predictions, and apply multi-fidelity techniques to forecast results to real-world network scales. The I2P networks we study are up to three orders of magnitude larger than the networks studied in SECURE and presented additional challenges to identify significant parameters. The key contributions of this project are the application of SECURE techniques such as UQ to a scenario of interest and scaling the SECURE techniques to larger network sizes. This report describes the experimental methods and results of these studies in more detail. In addition, the process of constructing these large-scale experiments tested the limits of the Firewheel emulation-based technologies. Therefore, another contribution of this work is that it informed the Firewheel developers of scaling limitations, which were subsequently corrected.

97 MATHEMATICS AND COMPUTING↗

Integration of Electric Power Infrastructure into the Drinking Water Shared Risk Framework: Prototype Development

An existing shared risk framework designed for assessing and comparing threat-based risks to water utilities is being extended to incorporate electric power. An important differentiating characteristic of this framework is the use of a system-centric rather than an asset-centric approach. This approach allows anonymous sharing of results and enables comparison of assessments across different utilities within an infrastructure sector. By allowing utility owners to compare their assessments with others, they can improve their self-assessments and identification of "unknown unknowns". This document provides an approach for extension of the framework to electric power, including treatment of dependencies and interdependencies. The systems, threats, and mathematical description of associated risks used in a prototype framework are provided. The method is extensible so that additional infrastructure sectors can be incorporated. Preliminary results for a proof of concept calculation are provided.

42 ENGINEERING↗

Bay Area Regional Energy: Network Integrated Commercial Retrofits (BRICR) Project. Final Report

The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessment of BQ-9000 Biodiesel Properties for 2021

This is the fifth in a series of reports documenting the quality of biodiesel from U.S. and Canadian-based producers that participate in the BQ-9000 program, the biodiesel industry voluntary quality assurance program. Participants agreed to provide monthly data on critical quality parameters for calendar year 2021. The quality data was provided to a team of experts, who removed any identifying company information and provided anonymized and randomized data to the National Renewable Energy Laboratory (NREL) for statistical analysis. The critical quality parameters analyzed were: sodium and potassium (Na+K); calcium and magnesium (Ca+Mg); phosphorus (P); flash point and alcohol control; water and sediment; cloud point; acid number; free and total glycerin; monoglycerides; sulfur; oxidation stability; and cold soak filterability test (CSFT). The data was not weighted for production volume.

09 BIOMASS FUELS↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Uncertainty of Fielded Photovoltaic Performance (Final Technical Report)

Improved analysis and reporting of photovoltaic (PV) field performance increases the certainty of owners and financiers that systems will perform as expected. Advanced module technologies (e.g., PERC, HJT, and bifacial) introduce new degradation mechanisms and performance characteristics. The FY19-21 Reducing Uncertainty project leveraged data from the ever-increasing PV fleet to develop models and understanding of the field performance of existing and new technologies. Specifically, we accomplished: report on field performance and degradation rates for high-efficiency silicon (HJT, PERC, IBC) and more conventional technologies; developed automated analysis techniques to quantify system performance (performance ratio, energy yield) and production shortfalls (soiling, degradation, availability); refined the RdTools software toolkit to bring standard, validated analysis techniques to bear on third-party data; analyzed and reported on large datasets including Treasury data and Lawrence Berkeley National Laboratory's Utility-Scale dataset to expand the high-quality degradation-rate histogram published previously; worked with industry partners and the DuraMAT data hub to enable private parties to share and aggregate PV production data anonymously, leveraging cloud-based data analysis infrastructure and publishing on US fleet-scale performance comprising over 7GW of operating systems. (https://www.nrel.gov/pv/fleet-performance-data-initiative.html). Through our industry collaborations we have engaged in NDA-covered data transfer with twelve PV fleet owners as of January 2022, with more agreements in negotiation. Our scalable cloud-based time series database contains over 30 billion rows (20TB) of PV time series data, representing over 1700 commercial and utility-scale systems, and over 7.2 GW of DC capacity (Fig 1). Initial field performance results have been distributed in several public reports. Because our fleet composition and data quality methods are continually improving, annual updates to these results are published to our PV Fleet webpage [ https://www.nrel.gov/pv/fleet-performance-data-initiative.html ] and DuraMAT data hub [DOI: 10.21948/1842958]. Another existing dissemination channel used for observed soiling losses is a map we maintain for soiling losses. Additional products developed include a report detailing fleet-wide performance index, availability, startup loss and snow loss factors, a detailed report on the 1603 grant dataset comprising over 100,000 PV systems with failure and performance details and a utility-scale report coauthored with LBNL on 31 GW of system performance.

14 SOLAR ENERGY↗

Analysis of Dust Samples Collected from a Near-Marine East Coast ISFSI Site ("Site C")

In June of 2022, dust samples were collected from the surface of an in-service spent nuclear fuel dry storage canister during an inspection at an Independent Spent Fuel Storage Installation. The site is anonymous but is a near-marine or brackish water east coast location referred to here as "Site C". The purpose of the sampling was to assess the composition and abundance of the soluble salts present on the canister surface, information that provides a metric for potential corrosion risks. Following collection, the samples were delivered to Sandia National Laboratories for analysis. At Sandia, the soluble salts were leached from the dust and quantified by ion chromatography. In addition, subsamples of the dust were taken for scanning electron microscopy to determine the particle sizes, morphology, and mineralogy of the dust and salts. The results of those analyses are presented in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SARS-CoV-2 transmission control in California correctional facilities

LBNL provided technical assistance to the CalPROTECT project, which is a collaboration between the University of California, Berkeley and the University of California, San Francisco. The CalPORTECT team provided support and guidance to the California Department of Corrections and Rehabilitation (CDCR) and the California Correctional Health Care Services (CCHCS) in their response to the COVID-19 pandemic. The CalPROTECT team provided recommendations to mitigate the risk posed to the residents and staff who live and work in CDCR prisons through considering scientific knowledge of the virus, analyzing anonymized resident and staff level data from CCHCS, evaluation of statewide and institution-level policies, and data collection during site visits to CDCR prisons during the pandemic.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of BQ-9000 Biodiesel Properties for 2022

This is the sixth in a series of reports documenting the quality of biodiesel from U.S. and Canadian-based producers that participate in the BQ-9000 program, the biodiesel industry voluntary quality assurance program. Participants agreed to provide monthly data on critical quality parameters for calendar year 2022. The quality data was provided to a team of experts, who removed any identifying company information and provided anonymized data to the National Renewable Energy Laboratory (NREL) for statistical analysis.

09 BIOMASS FUELS↗

Availability and Performance Loss Factors for U.S. PV Fleet Systems

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data and publish aggregated, anonymized results. This report is an update of our previous publications, specifically a FY 2021 performance index publication and a FY 2022 fleet degradation analysis. In this analysis, we have increased our data participants and system totals by around 10% to 8.5 GW and 24,000 separate inverter data channels. Four major analysis topics are considered in this report: Performance Index (PI) trends, PV system availability, soiling losses, and PV system degradation. Performance Index and inverter availability are assessed on a larger set of data from our FY 2021 report: 1,128 systems compared with 200 systems from before. The increased number of systems is due to an improved data quality methodology, as well as introducing new systems to the analysis. Overall results are similar to previously published values - overall inverter availability is low in the first six months of system performance before reaching steady-state by the end of the first year. Excluding this six-month startup period, system-level aggregated data shows a median (P50) system availability of 0.99 and a lower 10th percentile (P90) value of 0.95 (Figure ES-1). A dependence on system size is also demonstrated, with worse inverter availability results for larger PV systems. Causes of this effect are under investigation, but may be impacted by inverter size, which also show lower availability for larger inverter sizes. This report also investigates PI, correcting for degradation, soiling, snow, and availability. Following these corrections, the median system PI over its entire lifetime is 0.95. PI values reported here are approximately 3% lower than what we presented in our previous FY 2021 report. Soiling loss is assessed in a comprehensive way for the first time in this report. Results are presented using the COmbined Degradation and Soiling (CODS) method, as implemented in RdTools (v3.0.0a4). Soiling values are presented for 255 systems, which indicated irradiance-weighted soiling loss greater than 1%. The values have been published in an updated NREL soiling map at nrel.gov/pv/soiling.html. Finally, we investigated system degradation using three different data analysis techniques: conventional RdTools (year-on-year (YOY)), CODS, and Performance Loss Rate (PLR) analysis. Overall degradation results are consistent with our previous publications. Rerunning conventional RdTools on our updated fleet shows that some data partners have systematically fallen below the median system degradation rate (change over time) of -0.75 %/year. A comparison with PLR analysis, which looks at change in annual PI over time, shows that median system degradation is consistent with -0.5% to -0.75% per year change. However, at the P90 value, system degradation is substantially faster. These two results are consistent and indicate that resulting degradation statistics depend to a great degree on the population of PV systems making up the analysis cohort and whether soiling impacts the systems. The use of CODS for degradation analysis provides a different method for degradation assessment, which explicitly excludes the impact of recoverable soiling on degradation analysis. Excluding soiling effects yields an annual system degradation around -0.5% per year on average. This indicates that a portion of system performance loss may be attributed to periodic soiling that is not fully recovered. This report provides PV system owners/operators with background and methods to analyze PV system performance, give guidance for expected cohort performance, and performance loss values for use in pro-forma financial models, which guide new-build system design and bankability reports.

14 SOLAR ENERGY↗

PV System Availability from Commercial and Utility-Scale Systems [Slides]

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with worse inverter availability results for larger PV systems. Potential causes of this effect are under investigation.