Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Anion exchange membrane”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

2019 Anion Exchange Membrane Workshop Summary Report

The National Renewable Energy Laboratory, in coordination with the U.S. Department of Energy Fuel Cell Technologies Office, Advanced Research Projects Agency–Energy, and Los Alamos National Laboratory, hosted the 2019 Anion Exchange Membrane Workshop at the Sheraton Dallas Hotel in Dallas, Texas, on May 30, 2019. More than 50 industrial, academic, national laboratory, and government experts representing the needs of anion exchange membranes, membrane electrode assemblies, and system and stack components attended the workshop.

30 DIRECT ENERGY CONVERSION↗

Elucidating the degradation mechanisms of Pt-free anode anion-exchange membrane fuel cells after durability testing

The development of anion-exchange membrane fuel cells (AEMFCs) has recently accelerated due to synergistic improvements yielding highly conductive membranes, stable ionomers, and enhanced alkaline electrocatalysts. However, cell durability, especially under realistic conditions, still poses a major challenge. Herein, we employ low-loadings of Pt-free Pd-based catalysts in the anode of AEMFCs and elucidate potential degradation mechanisms impacting long-term performance under conditions analogous to the real-world (high current density, H 2 –air (albeit CO 2 -free), and intermittent operation). Our high-performing AEMFCs achieve impressive performance with power densities approaching 1 W cm —2 and current densities up to 3.5 A cm —2 . Over a 200 h period of continuous operation in H 2 –air at a current density of 600 mA cm —2 , our model Pd/C–CeO 2 anode cell exhibits record stability (~30 μV h —1 degradation) compared to the literature and up to 6× better stability than our Pd/C and commercial Pt/C anode cells. Following an 8 h shutdown, the Pd/C–CeO 2 anode cell was restarted and continued for an additional 300 h with a higher degradation rate of ~600 μV h —1 . Thorough in situ evaluations and post-stability analyses provide insights into potential degradation mechanisms to be expected during extended operation under more realistic conditions and provide mitigation strategies to enable the widespread development of highly durable AEMFCs.

08 HYDROGEN↗

Characterizing and modeling the mechanical behavior of an anion exchange membrane for carbon capture applications

A new direct air capture (DAC) technology uses a moisture swing (MS) process with anion exchange membranes, potentially offering a more energy-efficient way to remove CO₂ from the air. In this MS process, the membrane absorbs CO₂ as it dries and releases it when water is added. Understanding the mechanical behavior of these membranes is essential for improving the design and efficiency of DAC systems and prolonging sorbent lifetime. This study tested one anion exchange membrane, Fumasep’s FAA-3, under mechanical loading and various temperature and humidity conditions to measure its swelling, stiffness, strength, plastic deformation, and stress relaxation. Experimental results were used to identify a mechanical model for FAA-3 that can be used to predict the material’s nonlinear viscous behavior under various loads and environments. Unlike prior studies that assumed linear elastic behavior, this work incorporates humidity-dependent swelling, thermal expansion, and nonlinear viscoelasticity of FAA-3 in both the experiments and the model.

Direct air capture↗

Designing the Platinum Catalyst Layer for Improved Performance and Durability in Anion Exchange Membrane Water Electrolysis

To lower the cost of hydrogen produced by anion exchange membrane water electrolysis (AEMWE), it is critical to reduce the use of platinum group metal (PGM) catalysts within the device. While iridium has been successfully replaced with PGM-free catalysts at the anode, platinum-based (Pt) cathode catalysts are still required to meet the activity and durability targets. This study investigates the impact of commercial Pt/C catalyst loading, ionomer type and content, and electrode fabrication method on the cathode catalyst layer properties and AEMWE performance with the aim of determining the feasibility of reduced Pt loadings. While increased Pt loading is found to improve beginning-of-life performance, the effects are minimal above 0.6 mg/cm 2 . Ink characterization shows that ionomer type and content affect the ink stability, particle size, and percent of unbound ionomer, which further impact the homogeneity of the sprayed catalyst layers. The 5% PiperION cathode exhibited the highest performance, which may be attributed to a balance between the small particle size and the low proportion of unbound ionomer, minimizing kinetic and transport losses. Theoretical calculations show that the ionomers interact differently with the Pt surface, causing different surface charges and water adsorption strength and activating different mechanisms for hydrogen evolution. Pt-PiperION lowered the enthalpy of water-splitting by 0.1 eV compared to Pt alone and allowed for equal site access between adsorbed H* and OH* (both adsorbed at circa −2.2 eV). Although catalyst-coated membrane (CCM) fabrication techniques are desirable for scale-up, no performance enhancement is observed compared with the catalyst-coated substrate approach. Durability, as measured by degradation rates, Pt loss, and catalyst layer restructuring, was found to improve with increased Pt loadings, higher ionomer content, and CCM architectures. These findings provide important insight into the significant role of the cathode in AEMWE and strategies for maintaining the performance with low Pt loading or PGM-free catalysts.

08 HYDROGEN↗

Tuning Alkaline Anion Exchange Membranes through Crosslinking: A Review of Synthetic Strategies and Property Relationships

Alkaline anion exchange membranes (AAEMs) are an enabling component for next-generation electrochemical devices, including alkaline fuel cells, water and CO2 electrolyzers, and flow batteries. While commercial systems, notably fuel cells, have traditionally relied on proton-exchange membranes, hydroxide-ion conducting AAEMs hold promise as a method to reduce cost-per-device by enabling the use of non-platinum group electrodes and cell components. AAEMs have undergone significant material development over the past two decades; however, challenges remain in the areas of durability, water management, high temperature performance, and selectivity. In this review, we survey crosslinking as a tool capable of tuning AAEM properties. While crosslinking implementations vary, they generally result in reduced water uptake and increased transport selectivity and alkaline stability. We survey synthetic methodologies for incorporating crosslinks during AAEM fabrication and highlight necessary precautions for each approach.

08 HYDROGEN↗

Evaluating the effect of membrane-ionomer combinations and supporting electrolytes on the performance of cobalt nanoparticle anodes in anion exchange membrane electrolyzers

In low temperature polymer electrolyte membrane electrolyzers, component choices and membrane electrode assembly (MEA) fabrication have pivotal roles in determining cell performance. Here, cobalt anodes were used in combination with different ionomers, membranes, and supporting electrolytes to delineate their effect on MEA performance in anion exchange membrane (AEM) based electrolyzers. Changes to the ionomer type suppress or enhance catalyst redox and were found to alter the resulting exchange current densities and Tafel slopes. Changes in membrane conductivity account for large differences in performance and overpotential losses among the different MEAs, with higher conductivity minimizing ohmic losses. Within supporting electrolytes, lower concentration results in lower conductivity and lower MEA performance; the performance, however, is higher in potassium hydroxide than bicarbonate. These experiments address the influence of individual components and their integration on cell-level performance, to help develop a pathway to an electrolyte free system while providing a foundation for studying electrode composition and component incorporation into MEAs.

25 ENERGY STORAGE↗

Analytical-based simulation approach for an anion exchange membrane fuel cell

An analytical and empirical-based 1-D, non-isothermal, steady-state model for anion exchange membrane fuel cell capable of capturing two-phase phenomena is presented in this study. Coupled multi-physics including mass and charge transport, electrochemical reactions, heat transfer, and two-phase water transport are considered in the model and the simulated results are compared to experimental data. To better represent actual material properties and localized conditions, the model applies multilayer discretization in the gas diffusion electrode to enhance prediction accuracy. The model successfully predicts the baseline performance at 70 °C, 131 kPa abs., 92% RH with pure H 2 /O 2 gas as well as the limiting current at 10% H 2 . The robust simulation approach allows for simplistic and accurate estimation of cell performance without the complications of applying two-phase parameters and expensive computational need for numerical models. In addition, the results from the sensitivity studies of material properties and operating conditions provide valuable insights on water management strategies and optimal component design for advancing anion exchange membrane fuel cell technology.

1-D model↗

The Impact of Operational Strategies and Load Fluctuations on Anion Exchange Membrane Water Electrolyzer Degradation

This study reports on the durability of anion exchange membrane water electrolyzers (AEMWEs) at the cell level in a supporting electrolyte (1 M) and the impact of operational profiles on cell degradation. While constant load shows significant voltage loss, including a current hold at 1 A cm −2 and a potential hold at 2 V, it generally occurs in the first 70 h of testing. These losses are likely due to passivation altering site reactivity and cell kinetics, and are largely recoverable upon load cycling and diagnostics at the end of test. Furthermore, square and triangular-wave cycling do not show cell degradation and indicate that AEMWEs are not vulnerable to load cycling. When operating outside of this potential window (1.45–2 V), cell voltage decay rates markedly increase and the losses are not recoverable. This includes a current density hold at 4.0 A cm −2 with high cell voltages (>2.4 V for test duration) and cycling between 0 and 2 V to simulate start–stop, where more than a 50% loss in current density occurs over 50 h. The findings presented here demonstrate the high durability of AEMWEs, particularly when operating with load fluctuations, and may allow for durability advantages compared to iridium and proton exchange membrane systems.

08 HYDROGEN↗

Ionomer Optimization for Water Uptake and Swelling in Anion Exchange Membrane Electrolyzer: Oxygen Evolution Electrode

Water electrolysis using an anion conductive, solid polymer electrolyte is an attractive method for point-of-use hydrogen production. Recent advances in catalysts and anion exchange membranes (AEM) have made alkaline devices increasingly competitive with their acidic counterparts. However, less attention has been paid to the anion conductive ionomers (ACI) used in the fabrication of electrodes for AEM electrolyzers. The ACI contributes to ion conduction between the catalyst and bulk electrolyte and serves as a binder for adhering the catalyst to the gas diffusion layer and AEM. Ionic conductivity, water uptake and ionomer swelling are critical properties for electrode performance. High ion exchange capacity (IEC) in the ionomer is desired for reduced electrode resistance, however, it can lead to excess water uptake (WU) and disruptive ACI swelling. In this study, a series of poly(norbornene)-based ionomers were synthesized, characterized and used to fabricate oxygen evolving anodes for low-temperature AEM water electrolysis. The IEC of the ionomers (0 to 4.73 meq g −1 ) was adjusted by controlling the ratio of ion conducting to non-ion conducting norbornene monomers in the ACI tetrablock copolymers. Low conductivity ionomers are shown to yield the best-performing oxygen evolution electrodes, in the absence of ACI polymer cross-linking because they do not experience excessive water swelling. Light cross-linking within the anode ACI was used as a means to independently lower WU of the ionomer without compromising ionic conductivity. This control over water swelling allows higher ionic conductivity within the ACI to be used in water-fed electrolyzer applications. Other methods of water management were compared including the use of hydrophobic additives and adjustment of the ionomer concentration in the electrode. As a result, it was shown that the cell performance greatly benefits from a highly conductive ionomer in the oxygen evolution reaction electrode if the WU is managed.

08 HYDROGEN↗

Effects of the Hydrophobic Block Length Ratio of Poly(vinylbenzyl N -methylpiperidinium carbonate)- b -polyethylene- b -poly(vinylbenzyl N -methylpiperidinium carbonate) Block Copolymers for Anion Exchange Membrane Electrolysis

Electrolysis of water to produce hydrogen from renewable electricity is an extremely attractive strategy to reduce energy dependence on fossil fuels. Development of membrane and ionomer materials that maintain high performance with long lifetimes is needed. We developed and investigated the performance and durability of a series of polyethylene-based ABA triblock copolymer anion exchange ionomer and membrane (AEI, AEM) materials for anion exchange membrane water electrolysis. Poly(vinylbenzyl N-methylpiperidinium carbonate)-b-polyethylene-b-poly(vinylbenzyl N-methylpiperidinium carbonate) was synthesized with different hydrophobic/hydrophilic block ratios (1.02:1, 2.58:1, and 4.46:1) resulting in a range of ion exchange capacities (1.1–1.8 meq g –1 ) and water swelling (23–154%) characteristics. All AEMs showed full anionic dissociation, as evidenced by linear Arrhenius correlations, and excellent carbonate conductivity of 8–94 mS cm –1 at 50 °C. Hydrophilic phase separation may offer superior chemical durability by only wetting the ion-conducting region of the polymer and avoiding attack at the nonwetted backbone. We evaluated the performance and durability of these AEMs as a function of hydrophobic polyethylene (PE) content. The AEM containing the least amount of PE displayed the highest performance of 1 A cm –2 at 2.3 V but degraded at 40 mV h –1 before catastrophically failing after <3 h at 0.5 A cm –2 . With greater PE-containing AEMs, the degradation rate was reduced by 3 orders of magnitude with only a 0.2 V increase in voltage. Constant current electrolysis for 50 h resulted in a voltage change of 0.3 mV h –1 in a single-cell water electrolyzer and 1 M potassium carbonate. In a 600 h test, the voltage change in the final 200 h was impressively low for an experimental film, 58 μV h –1 . Postmortem analysis indicated that the membrane did not thin and that water becomes more tightly hydrogen-bound in the polymer after electrolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imidazolium-Type Anion Exchange Membranes for Improved Organic Acid Transport and Permselectivity in Electrodialysis

Most commercial anion exchange membranes (AEMs) deploy quaternary ammonium moieties. Alternative cation moieties have been explored in AEMs for fuel cells, but there are no studies focused examining alternative tethered cations in AEMs for ionic separations—such as organic acid anion transport via electrodialysis. H-cell and conductivity experiments demonstrate that tethered benzyl 1-methyl imidazolium groups in polysulfone AEMs enhance lactate conductivity by 49% and improved lactate anion flux by 24x when compared to a quaternary benzyl ammonium polysulfone AEM. An electrodialysis demonstration with the imidazolium-type AEM showed a 2x improvement in lactate anion flux and 20% improvement in permselectivity when benchmarked against the quaternary ammonium AEM. Molecular dynamics and 2D NOESY NMR revealed closer binding of lactate anions to the imidazolium cations when compared to the quaternary ammonium cation. It is posited that this closer binding is responsible to greater flux values observed with imidazolium-type AEM.

36 MATERIALS SCIENCE↗

Probing Anion Exchange Membrane Fuel Cell Cathodes by Varying Electrocatalysts and Electrode Processing

To date, several high-performing anion exchange membrane fuel cells (AEMFCs) have been demonstrated, but most these studies have focused on Pt containing cathodes with high loadings. Here, we explore and compare the performance and perform electrochemical diagnostics on three leading AEMFC cathode electrocatalysts: Pt/C, Ag/C, and Fe–N–C with electrodes that have been processed with either powder or dispersion-based ionomers using perfluorinated anion exchange polymers. Pt/C had the highest performance but also showed a strong dependence on ionomer type, with powder ionomer exhibiting much higher performance. These results were consistent with the observations for Ag/C but did not hold for the Fe–N–C catalyst where almost no change was observed between powder and dispersion-based ionomers. This is the first-time the impact of powder and dispersion ionomer with different classes of cathode electrocatalysts on the fuel cell performance have been compared, and the results have strong implications for the ability to achieve high performance at low loadings and for better understanding catalyst-ionomer interactions within AEMFCs.

30 DIRECT ENERGY CONVERSION↗

Degradation of Anion Exchange Membranes by Cation Elimination: Impact on Water Uptake, Nanostructure, and Ionic Mobility

Anion exchange membranes (AEMs) are an attractive platform for fuel cell and electrolysis technologies since they enable the use of cheaper, nonplatinum group metal electrodes and components. However, the widespread adoption of AEM-based devices is limited by chemical degradation of the AEM in the highly alkaline medium of operation. Experimental studies report three major pathways of degradation, including substitution (S N 2), elimination (E2), and backbone cleavage. The decline in membrane performance is likely due to a cumulative effect of several pathways, which has proven to be difficult to disentangle through experiments. Here we use coarse-grained molecular simulations to isolate the impact of E2 degradation, where cationic sites are replaced by an alkene group, on AEM water uptake, nanoscale morphology, structure of the ion-conducting channels, water mobility, and ionic conductivity. Our studies focus on the well-studied model AEM polyphenylene oxide with tetraalkylammonium cationic sites (PPO-TMA). We find that about half of the hydrophobic groups resulting from the degradation retract into the hydrophobic domains of the membrane. The reduction in ion exchange capacity (IEC) and the hydrophobicity of the alkene groups decrease both the equilibrium water uptake (%WU) and the number of water molecules per cation (λ) of the membrane. Interestingly, the evolution of λ with the IEC seems to follow that of undegraded PPO-TMA membranes. Additionally, we ascribe this to the similarity between the structure of the degraded monomer and the neutral one in the polymer. We conclude that most of the performance losses originate in the lower hydration of the degraded membrane.

36 MATERIALS SCIENCE↗

The Role of Water Volume Fraction on Water Adsorption in Anion Exchange Membranes

Water absorption plays a key role in the performance of polymeric anion exchange membranes. It influences important properties such as ionic conductivity and mechanical strength and alters their performance as solid electrolytes in hydrogen electrochemical devices for energy conversion. However, computational approaches that address the relationship between the polymer design and the absorption process are scarce. In this work, we introduce a simple thermodynamic model to predict the water absorption isotherms of polyelectrolyte membranes in contact with a water vapor reservoir that incorporates the specific chemical design of the polymers. The model accurately predicts the water content and macrostructural properties of polynorbornene membranes as a function of the water activity and successfully captures the effect of various polymer design parameters. The energy of pairwise attractive interactions predicted by our model provides a means to interpret the absorption process at the molecular level. The model also reveals the most significant favorable and unfavorable contributions to the free energy and indicates that their balance is solely governed by the water volume fraction, regardless of the polymer design. This universal behavior leads to important implications in the search for better ion exchange membranes.

Zaldivar, Gervasio [New York University, Brooklyn,↗

Elucidating the Role of Hydroxide Electrolyte on Anion-Exchange-Membrane Water Electrolyzer Performance

Many solid-state devices, especially those requiring anion conduction, often add a supporting electrolyte to enable efficient operation. The prototypical case is that of anion-exchange-membrane water electrolyzers (AEMWEs), where addition of an alkali metal solution improves performance. However, the specific mechanism of this performance improvement is currently unknown. This work investigates the functionality of the alkali metal solution in AEMWEs using experiments and mathematical models. The results show that additional hydroxide plays a key role not only in ohmic resistance of the membrane and catalyst layer but also in the reaction kinetics. The modeling suggests that the added liquid electrolyte creates an additional electrochemical interface with the electrocatalyst that provides ion-transport pathways and distributes product gas bubbles; the total effective electrochemical active surface area in the cell with 1 M KOH is 5 times higher than that of the cell with DI water. In the cell with 1 M KOH, more than 80% of the reaction current is associate with the liquid electrolyte. These results indicate the importance of high pH of electrolyte and catalyst/electrolyte interface in AEMWEs. The understanding of the functionality of the alkali metal solution presented in this study should help guide the design and optimization of AEMWEs.

25 ENERGY STORAGE↗

Anion-exchange membrane water electrolysis: insights from round-robin testing

As research and industrial interest in anion-exchange membrane water electrolysis (AEMWE) grows, there is an increasing need for reliable baselines and cross-lab validation of results. The wide variety of material sets and operating conditions under consideration for AEMWE has thus far limited efforts for standardization. In this study, round-robin testing was conducted in deionized water and KOH-based supporting electrolyte by 5 institutions from academia, national laboratories, and industry to provide baseline performance data and identify sources of cross-lab variability. Baseline membrane electrode assemblies were fabricated with commercial catalysts, membranes, and transport layers using standard techniques and tested using reagent-grade electrolytes, aiming for accessibility rather than state-of-the-art performance. From all tests, the average voltage at 1 A/cm 2 was 2.72 ± 0.17 V and 1.87 ± 0.03 V in deionized water and 0.1 M KOH, respectively. The maximum in-house and cross-lab variations at this current density were 118 mV and 476 mV in water and 60 and 88 mV in 0.1 M KOH. The KOH purity, station contamination, and temperature control were identified as possible factors affecting performance between labs, with in-house specific variation attributed to sample-to-sample differences in fabrication, cell assembly, and station contamination. This work provides a commercial baseline for the field and highlights the need for improved standardization and reproducibility in AEMWE research.

08 HYDROGEN↗