Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Angular Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Long-lived qubit from three spin-(1/2) atoms

A system of three spin-(1/2) atoms allows the construction of a reference-frame-free (RFF) qubit in the subspace with total angular momentum j=1/2. The RFF qubit stays coherent perfectly as long as the spins of the three atoms are affected homogeneously. The inhomogeneous evolution of the atoms causes decoherence, but this decoherence can be suppressed efficiently by applying a bias magnetic field of modest strength perpendicular to the plane of the atoms. The resulting lifetime of the RFF qubit can be many days, making RFF qubits of this kind promising candidates for quantum information storage units. Specifically, we examine the situation of three {sup 6}Li atoms trapped in a CO{sub 2}-laser-generated optical lattice and find that, with conservatively estimated parameters, a stored qubit maintains a fidelity of 0.9999 for two hours.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360 Degree-Sign through anthropomorphic voxelized female chest and head (0 Degree-Sign and 30 Degree-Sign tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tables of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI{sub vol} and multiplying by a physical CTDI{sub vol} measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30 Degree-Sign relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results indicate total organ doses calculated using our database are within 1% of those calculated using Monte Carlo simulations with the same geometry and scan parameters for all organs except red bone marrow (within 6%), and within 23% of published estimates for different voxelized phantoms. Results from the example of using the database to estimate organ dose for coronary angiography CT acquisitions show 2.1%, 1.1%, and -32% change in breast dose and 2.1%, -0.74%, and 4.7% change in lung dose for reduced kVp, tube current modulated, and partial angle protocols, respectively, relative to the reference protocol. Results show -19.2% difference in dose to eye lens for a tilted scan relative to a nontilted scan. The reported relative changes in organ doses are presented without quantification of image quality and are for the sole purpose of demonstrating the use of the proposed database. Conclusions: The proposed database and calculation method enable the estimation of organ dose for coronary angiography and brain perfusion CT scans utilizing any spectral shape and angular tube current modulation scheme by taking advantage of the precalculated Monte Carlo simulation results. The database can be used in conjunction with image quality studies to develop optimized acquisition techniques and may be particularly beneficial for optimizing dual kVp acquisitions for which numerous kV, mA, and filtration combinations may be investigated.

60 APPLIED LIFE SCIENCES↗

White organic light-emitting diodes with 4 nm metal electrode

We investigate metal layers with a thickness of only a few nanometers as anode replacement for indium tin oxide (ITO) in white organic light-emitting diodes (OLEDs). The ultrathin metal electrodes prove to be an excellent alternative that can, with regard to the angular dependence and efficiency of the OLED devices, outperform the ITO reference. Furthermore, unlike ITO, the thin composite metal electrodes are readily compatible with demanding architectures (e.g., top-emission or transparent OLEDs, device unit stacking, etc.) and flexible substrates. Here, we compare the sheet resistance of both types of electrodes on polyethylene terephthalate for different bending radii. The electrical performance of ITO breaks down at a radius of 10 mm, while the metal electrode remains intact even at radii smaller than 1 mm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new generation of x-ray spectrometry UHV instruments at the SR facilities BESSY II, ELETTRA and SOLEIL

A novel type of ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation (SR) has been constructed and commissioned at BESSY II. This versa-tile instrument was developed by the PTB, Germany’s national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, it integrates a rotational and translational movement of several photodiodes as well as a translational movement of a beam-geometry-defining aperture system. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors such as reference-free X-Ray Fluorescence (XRF) analysis, total-reflection XRF, grazing-incidence XRF, in addition to optional X-Ray Reflectometry (XRR) measurements or polarization-dependent X-ray absorption fine structure analyses (XAFS). Samples having a size of up to (100 × 100) mm{sup 2}; can be analyzed with respect to their mass deposition, elemental, spatial or species composition. Surface contamination, nanolayer composition and thickness, depth pro-file of matrix elements or implants, nanoparticles or buried interfaces as well as molecular orientation of bonds can be accessed. Three technology transfer projects of adapted instruments have enhanced X-Ray Spectrometry (XRS) research activities within Europe at the synchrotron radiation facilities ELETTRA (IAEA) and SOLEIL (CEA/LNE-LNHB) as well as at the X-ray innovation laboratory BLiX (TU Berlin) where different laboratory sources are used. Here, smaller chamber requirements led PTB in cooperation with TU Berlin to develop a modified instrument equipped with a 7-axis manipulator: reduced freedom in the choice of experimental geometry modifications (absence of out-of-SR-plane and reference-free XRS options) has been compensated by encoder-enhanced angular accuracy for GIXRF and XRR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A search for warm/hot gas filaments between pairs of SDSS Luminous Red Galaxies

Abstract We search the Planck data for a thermal Sunyaev–Zel’dovich (tSZ) signal due to gas filaments between pairs of Luminous Red Galaxies (LRGs) taken from the Sloan Digital Sky Survey Data Release 12 (SDSS/DR12). We identify ∼260 000 LRG pairs in the DR12 catalogue that lie within 6–10 $h^{-1} \, \mathrm{Mpc}$ of each other in tangential direction and within 6 $h^{-1} \, \mathrm{Mpc}$ in radial direction. We stack pairs by rotating and scaling the angular positions of each LRG so they lie on a common reference frame, then we subtract a circularly symmetric halo from each member of the pair to search for a residual signal between the pair members. We find a statistically significant (5.3σ) signal between LRG pairs in the stacked data with a magnitude Δy = (1.31 ± 0.25) × 10−8. The uncertainty is estimated from two Monte Carlo null tests which also establish the reliability of our analysis. Assuming a simple, isothermal, cylindrical filament model of electron overdensity with a radial density profile proportional to rc/r (as determined from simulations), where r is the perpendicular distance from the cylinder axis and rc is the core radius of the density profile, we constrain the product of overdensity and filament temperature to be $\delta _\mathrm{ c} \times (T_{\rm e}/10^7 \, {\rm K}) \times (r_\mathrm{ c}/0.5h^{-1} \, {\rm Mpc}) = 2.7 \pm 0.5$. To our knowledge, this is the first detection of filamentary gas at overdensities typical of cosmological large-scale structure. We compare our result to the BAHAMAS suite of cosmological hydrodynamic simulations (McCarthy et al. 2017) and find a slightly lower, but marginally consistent Comptonization excess, Δy = (0.84 ± 0.24) × 10−8.

Tanimura, Hideki↗

Spatial locality of electronic correlations in LiFeAs

In this work, we address the question of the degree of spatial nonlocality of the self-energy in the iron-based superconductors, a subject which is receiving considerable attention. Using LiFeAs as a prototypical example, we extract the self-energy from angular-resolved photoemission spectroscopy data. We use two distinct electronic structure references: density functional theory in the local density approximation and linearized quasiparticle self-consistent GW (LQSGW). We find that with the LQSGW reference, spatially local dynamical correlations provide a consistent description of the experimental data, and account for some surprising aspects of the data such as the substantial out-of-plane dispersion of the electron Fermi surface having dominant xz/yz character. Hence, correlations effects can be separated into static nonlocal contributions well described by LQSGW and dynamical local contributions. Hall effect and resistivity data are shown to be consistent with this description.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-494: Influence of Proton Track-Cell Nucleus Incidence Angle On Relative Biological Effectiveness

Purpose: To explain a Monte Carlo (MC) simulation artifact whereby differences in relative biological effectiveness (RBE) in the induction of initial double strand breaks are observed as a function of the proton track incidence angles in a geometric cell nucleus model. Secondly, to offer an alternative isotropic irradiation procedure to mitigate this effect. Methods: MC tracks of 1 MeV protons were generated in an event-by-event mode. They were overlaid on a cylindrical model of a cell nucleus containing 6×109 nucleotide base pairs. The tracks incidence angle θ with respect to the cell nucleus’s axis was varied in 10 degrees intervals, each time generating one hundred fractions of ∼2 Gy. Strand breaks were scored in the modeled DNA sugar-phosphate groups and further sub-classified into single or double strand breaks (ssbs or dsbs). For each angle, an RBE for the induction of initial dsbs with reference to Co-60 was calculated. Results: Our results show significant angular dependencies of RBE, with maximum values for incidence angles parallel to the nucleus central axis. Further examination shows that the higher cross-sections for the creation of dsbs is due to the preferential alignment of tracks with geometrical sub-parts of the cell nucleus model, especially the nucleosomes containing the sugar-phosphate groups. To alleviate the impact of this simulation artifact, an average RBE was calculated with a procedure based on a weighted sampling of the angular data. Conclusion: This work demonstrates a possible numerical artifact in estimated RBE if the influence of the particle incidence angle is not correctly taken into account. A correction procedure is presented to better conform the simulations to real-life experimental conditions. We would like to acknowledge support from the Fonds de recherche du Quebec Sante (FRQS), from the CREATE Medical Physics Research Training Network grant (number 432290) of NSERC, support from NSERC under grants RGPIN 397711-11 and RGPIN-2014-06475 and support from the CIHR under grants MOP-114910, MOP-136774 and MOP-102550.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRA-01: A Novel 3D Registration Method for Multiparametric Radiological Images

Purpose: Multiparametric and multimodality radiological imaging methods, such as, magnetic resonance imaging(MRI), computed tomography(CT), and positron emission tomography(PET), provide multiple types of tissue contrast and anatomical information for clinical diagnosis. However, these radiological modalities are acquired using very different technical parameters, e.g.,field of view(FOV), matrix size, and scan planes, which, can lead to challenges in registering the different data sets. Therefore, we developed a hybrid registration method based on 3D wavelet transformation and 3D interpolations that performs 3D resampling and rotation of the target radiological images without loss of information Methods: T1-weighted, T2-weighted, diffusion-weighted-imaging(DWI), dynamic-contrast-enhanced(DCE) MRI and PET/CT were used in the registration algorithm from breast and prostate data at 3T MRI and multimodality(PET/CT) cases. The hybrid registration scheme consists of several steps to reslice and match each modality using a combination of 3D wavelets, interpolations, and affine registration steps. First, orthogonal reslicing is performed to equalize FOV, matrix sizes and the number of slices using wavelet transformation. Second, angular resampling of the target data is performed to match the reference data. Finally, using optimized angles from resampling, 3D registration is performed using similarity transformation(scaling and translation) between the reference and resliced target volume is performed. After registration, the mean-square-error(MSE) and Dice Similarity(DS) between the reference and registered target volumes were calculated. Results: The 3D registration method registered synthetic and clinical data with significant improvement(p<0.05) of overlap between anatomical structures. After transforming and deforming the synthetic data, the MSE and Dice similarity were 0.12 and 0.99. The average improvement of the MSE in breast was 62%(0.27 to 0.10) and prostate was 63%(0.13 to 0.04;p<0.05). The Dice similarity was in breast 8%(0.91 to 0.99) and for prostate was 89%(0.01 to 0.90;p<0.05) Conclusion: Our 3D wavelet hybrid registration approach registered diverse breast and prostate data of different radiological images(MR/PET/CT) with a high accuracy.

60 APPLIED LIFE SCIENCES↗

Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques

Purpose: To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. Methods: The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch distance and a sensitive volume of about 4 mm{sup 3}. The detector has been characterized with {sup 60}Co radiation and MV x rays from different linear accelerators (with flattened and unflattened beam qualities). Sensitivity dependence on dose per pulse has been evaluated under MV x rays by changing both the source to detector distance and the beam quality. Bias voltage has been varied in order to evaluate the charge collection efficiency in the most critical conditions. Relative dose profiles have been measured for both flattened and unflattened distributions with different field sizes. The reference detectors were a commercial array of ionization chambers and an amorphous silicon flat panel in direct conversion configuration. Profiles of dose distribution have been measured also with intensity modulated radiation therapy (IMRT), stereotactic radiosurgery (SRS), and volumetric modulated arc therapy (VMAT) patient plans. Comparison has been done with a commercial diode array and with Gafchromic EBT3 films. Results: Repeatability and stability under continuous gamma irradiation are within 0.3%, in spite of low active volume and sensitivity (∼200 pC/Gy). Deviation from linearity is in the range [0.3%, −0.9%] for a dose of at least 20 cGy, while a worsening of linearity is observed below 10 cGy. Charge collection efficiency with 2.67 mGy/pulse is higher than 99%, leading to a ±0.9% sensitivity change in the range 0.09–2.67 mGy/pulse (covering all flattened and unflattened beam qualities). Tissue to phantom ratios show an agreement within 0.6% with the reference detector up to 34 cm depth. For field sizes in the range 2 × 2 to 15 × 15 cm{sup 2}, the output factors are in agreement with a thimble chamber within 2%, while with 25 × 25 cm{sup 2} field size, an underestimation of 4.0% was found. Agreement of field and penumbra width measurements with the flat panel is of the order of 1 mm down to 1 × 1 cm{sup 2} field size. Flatness and symmetry values measured with the 1D array and the reference detectors are comparable, and differences are always smaller than 1%. Angular dependence of the detector, when compared to measurements taken with a cylindrical chamber in the same phantom, is as large as 16%. This includes inhomogeneity and asymmetry of the design, which during plan verification are accounted for by the treatment planning system (TPS). The detector is capable to reproduce the dose distributions of IMRT and VMAT plans with a maximum deviation from TPS of 3.0% in the target region. In the case of VMAT and SRS plans, an average (maximum) deviation of the order of 1% (4%) from films has been measured. Conclusions: The investigated technology appears to be useful both for Linac QA and patient plan verification, especially in treatments with steep dose gradients and nonuniform dose rates such as VMAT and SRS. Major limitations of the present prototype are the linearity at low dose, which can be solved by optimizing the readout electronics, and the underestimation of output factors with large field sizes. The latter problem is presently not completely understood and will require further investigations.

60 APPLIED LIFE SCIENCES↗

Scattering Angular Distributions in the ENDF/B Nuclear Data Library

Nuclear reactors function by controlling the chain reaction of fission events in a fissile material. Understanding the gain and loss of neutrons is crucial for controlling this chain reaction. The role of fission in liberating neutrons from nuclei is well known. The fact that neutrons can scatter out of a reactor and therefore be lost is less well appreciated. Scattering can happen within fissile fuel or off of any number of the non-fissile structural components holding a reactor together. The scattering angular distributions for reactor material are the quantity that give the probability for a particle (usually a neutron) to scatter off a nucleus into a given angle. The Evaluated Nuclear Data File/B (ENDF/B) nuclear data library is the most complete and authoritative reference for neutron scattering data, containing reaction cross sections and outgoing particle distributions (including scattering angular distributions). In this project, we will compare the scattering angular distributions given in these ENDF/B data sets with those that can be derived using the Blatt-Biedenharn formalism and the resolved resonance data also in the ENDF/B files. More comparisons between the scattering angular distributions of relevant isotopes will help identify and correct any errors in the ENDF/B files. The results of this study will be an important component of the next major release of the ENDF/B library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Four-year Cosmology Large Angular Scale Surveyor (CLASS) Observations: On-sky Receiver Performance at 40, 90, 150, and 220 GHz Frequency Bands

The Cosmology Large Angular Scale Surveyor (CLASS) observes the polarized cosmic microwave background (CMB) over the angular scales of 1° ≲ θ ≤ 90° with the aim of characterizing primordial gravitational waves and cosmic reionization. We report on the on-sky performance of the CLASS Q-band (40 GHz), W-band (90 GHz), and dichroic G-band (150/220 GHz) receivers that have been operational at the CLASS site in the Atacama desert since 2016 June, 2018 May, and 2019 September, respectively. We show that the noise-equivalent power measured by the detectors matches the expected noise model based on on-sky optical loading and lab-measured detector parameters. Using Moon, Venus, and Jupiter observations, we obtain power to antenna temperature calibrations and optical efficiencies for the telescopes. From the CMB survey data, we compute instantaneous array noise-equivalent-temperature sensitivities of 22, 19, 23, and 71 $\mu {{\rm{K}}}_{\mathrm{cmb}}\sqrt{{\rm{s}}}$ for the 40, 90, 150, and 220 GHz frequency bands, respectively. These noise temperatures refer to white noise amplitudes, which contribute to sky maps at all angular scales. Future papers will assess additional noise sources impacting larger angular scales.

Observational cosmology↗

Angular momentum of elliptically polarised cnoidal waves and breathers in a nonlinear gyrotropic medium with frequency dispersion

We have analysed expressions for the spin part of the density vector of the angular momentum (moment of momentum) of elliptically polarised cnoidal waves and breathers propagating in an isotropic gyrotropic medium with second order frequency dispersion and spatial cubic nonlinearity dispersion. We have found that, due to nonlinear gyration, the density of the angular momentum depends on time and propagation coordinates. The bibliography includes 25 references. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Isospin effects in N ≈ Z nuclei in extended density functional theory

This paper overviews various phenomena related to the concept of isospin symmetry. The focus is on N ≈ Z nuclei, which are excellent laboratories of isospin physics. The theoretical framework applied is nuclear density functional theory and its isospin- and angular-momentum projected extensions, as well as symmetry-projected multi-reference models. The topics covered include: isospin impurities, superallowed beta decays, beta-transitions in mirror nuclei, isospin breaking hadronic interactions, mirror and triplet binding energy differences, and isoscalar pairing.

Physics↗

Phonon Helicity Induced by Electronic Berry Curvature in Dirac Materials

In two-dimensional insulators with time-reversal (TR) symmetry, a nonzero local Berry curvature of low-energy massive Dirac fermions can give rise to nontrivial spin and charge responses, even though the integral of the Berry curvature over all occupied states is zero. In this Letter, we present a new effect induced by the electronic Berry curvature. By studying electron-phonon interactions in BaMnSb2, a prototype two-dimensional Dirac material possessing two TR-related massive Dirac cones, we find that the nonzero local Berry curvature of electrons can induce a phonon angular momentum. The direction of this phonon angular momentum is locked to the phonon propagation direction, and thus we refer to it as “phonon helicity” in a way that is reminiscent of electron helicity in spin-orbit-coupled electronic systems. We discuss possible experimental probes of such phonon helicity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gravitational radiation and angular momentum flux from a slowly rotating dynamical black hole

A four-dimensional asymptotic expansion scheme is used to study the next-order effects of the nonlinearity near a spinning dynamical black hole. The angular-momentum flux and energy flux formula are then obtained by constructing the reference frame in terms of the compatible constant spinors and the compatibility of the coupling leading-order Newman-Penrose equations. By using the slow rotation and small-tide approximation for a spinning black hole, the horizon cross-section we chose is spherical symmetric. It turns out the flux formula is rather simple and can be compared with the known results. Directly from the energy flux formula of the slow-rotating dynamical horizon, we find that the physically reasonable condition on requiring the positivity of the gravitational energy flux yields that the shear will monotonically decrease with time. Thus a slow-rotating dynamical horizon will asymptotically approach an isolated horizon during late time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Errors introduced in fission neutron spectrum measurements using a single reference

Measurements of physical quantities are often made relative to a reference quantity, simplifying the interpretation of the measurement and its uncertainties. However, if applied without careful considerations, this technique can carry with it a significant and complex systematic error that is usually ignored. For example, measurements of continuous neutron spectra relative to a reference spectrum yield a result that does not properly include the important effects of neutron scattering in the experimental environment. These effects act to distort the measured spectrum shape and create notable errors in spectrum-integrated quantities. While this effect is one of a series of known potential sources of systematic error including, but not limited to target impurities, angular distributions, incident beam flux, and others, the error introduced from differences in environmental scattering effects between the reference and desired spectra are frequently overlooked. In this work, we demonstrate the origin of this error using simulated data corresponding to measurements of the neutron-induced prompt fission neutron spectra of 233 U, 235 U, 238 U, and 239 Pu as well as the spontaneous fission neutron spectrum of 252 Cf. Errors in the spectrum shape can be as high as 10%–15% depending on the combination of incident and outgoing neutron energy. The spectrum integral and average spectrum energy also contain errors that change with incident neutron energy and can be as high as ~2%. Although this study is based on simulated data, we also show a method for proving that this error exists in an experimental data set and we show a correction that can be applied to results of this type to obtain a more accurate result, thereby largely removing systematic errors from environmental scattering effects. The potential for these kinds of errors should be considered in measurements producing continuous neutron spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric characterization of a synthetic single crystal diamond detector in clinical radiation therapy small photon beams

Purpose: To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams. Methods: The dosimetric properties of a diamond-based detector were assessed by comparison with a reference microionization chamber. The diamond device was operated at zero bias voltage under irradiation with high-energy radiotherapic photon beams. The stability of the detector response and its dose and dose rate dependence were measured. Different square field sizes ranging from 1 Multiplication-Sign 1 cm{sup 2} to 10 Multiplication-Sign 10 cm{sup 2} were used during comparative dose distribution measurements by means of percentage depth dose curves (PDDs), lateral beam profiles, and output factors. The angular and temperature dependence of the diamond detector response were also studied. Results: The detector response shows a deviation from linearity of less than {+-}0.5% in the 0.01-7 Gy range and dose rate dependence below {+-}0.5% in the 1-6 Gy/min range. PDDs and output factors are in good agreement with those measured by the reference ionization chamber within 1%. No angular dependence is observed by rotating the detector along its axis, while {approx}3.5% maximum difference is measured by varying the radiation incidence angle in the polar direction. The temperature dependence was investigated as well and a {+-}0.2% variation of the detector response is found in the 18-40 Degree-Sign C range. Conclusions: The obtained results indicate the investigated synthetic diamond-based detector as a candidate for small field clinical radiation dosimetry in advanced radiation therapy techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Separated fringe packet observations with the Chara Array. II. ω Andromeda, HD 178911, and ξ Cephei

When observed with optical long-baseline interferometers, components of a binary star that are sufficiently separated produce their own interferometric fringe packets; these are referred to as separated fringe packet (SFP) binaries. These SFP binaries can overlap in angular separation with the regime of systems resolvable by speckle interferometry at single, large-aperture telescopes and can provide additional measurements for preliminary orbits lacking good phase coverage, help constrain elements of already established orbits, and locate new binaries in the undersampled regime between the bounds of spectroscopic surveys and speckle interferometry. In this process, a visibility calibration star is not needed, and the SFPs can provide an accurate vector separation. In this paper, we apply the SFP approach to ω Andromeda, HD 178911, and ξ Cephei with the CLIMB three-beam combiner at the CHARA Array. For these systems we determine component masses and parallax of 0.963 ± 0.049 M {sub ☉} and 0.860 ± 0.051 M {sub ☉} and 39.54 ± 1.85 mas for ω Andromeda, for HD 178911 of 0.802 ± 0.055 M {sub ☉} and 0.622 ± 0.053 M {sub ☉} with 28.26 ± 1.70 mas, and masses of 1.045 ± 0.031 M {sub ☉} and 0.408 ± 0.066 M {sub ☉} and 38.10 ± 2.81 mas for ξ Cephei.

79 ASTRONOMY AND ASTROPHYSICS↗