Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Angular Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Speckle interferometry of Hipparcos link stars. III

A third list of stars is presented which have been tested by speckle interferometry for use in the Hubble Space Telescope link between the Hipparcos astrometric reference frame and the extragalactic VLBI reference frame. Structural information on angular scales of 0.15-1.2 arcsec for 34 Southern Hemisphere stars is reported from observations made with the Imperial College Speckle Interferometer mounted on the Mount Stromlo 1.9-m telescope. Twenty-four percent of the stars (8 out of the 34) show evidence of multiplicity, in agreement with previous observations in this program.

White, Graeme L.↗

Calibrating Airplane Instrumentation To Measure Winds

Elaborate combination of techniques used to calibrate wind-measuring instrumentation aboard F104 airplane. Obtains wind profiles more rapidly. Airplane equipped with standard NACA research nose boom, including pressure probes and flow vanes yielding data on static and total pressures, angle of attack, and angle of sideslip. Has ring-laser-gyroscope inertial reference unit, giving linear and angular velocities, linear acceleration, and orientation of airplane. Body-mounted total-temperature sensor also used. Improved method of calibration devised to determine whether winds aloft at and shortly after time of measurement allow safe launch of Space Shuttle. Proves beneficial in other safety- or research-oriented applications in which wind velocities over range of altitudes must be determined in nearly real time.

Haering, Edward A., Jr.↗

Angular diameters as a probe of a cosmological constant and Omega

The lensing effect of curved space, which can cause the angular diameter of a fixed reference length seen on the sky to reach a minimum and then increase with redshift, has recently been claimed to provide evidence, using compact radio sources, for a q sub 0 = 1/2 expansion. We show here that this relation, in particular the position of the observed minimum, depends sensitively on the value of the cosmological constant, Lambda, in a flat universe. The sensitivity to a nonzero Lambda in a flat universe is compared to the sensitivity to q sub 0 in an open universe without a cosmological constant. The reported results could provide the strongest available limit on the cosmological constant in a flat universe (and on Omega in an open universe) and so we explore how uncertainties in distance measures and evolution of the sources can affect the results. Evolution of less than 30 percent in source size for z of less than 2 can completely alter the results, and so must be convincingly ruled out if this technique is to provide a new tool for cosmology.

Krauss, Lawrence M.↗

Determination of launch conditions for Spacelab satisfying the constraints of an absorption spectroscopy project

The conditions for absorption spectroscopy of the homosphere between 20 and 100 km from a space platform such as Spacelab are considered. Using nominal orbital elements, and taking launch data and time as parameters of the problem, formula were established that give the data necessary for determining the flight plan. The geographical coordinates of the tangential points of the solar illumination boundaries were also calculated. It is shown that the latitude coverage of the observation is closely related to launch conditions. Expressions for the pointing angles referred to an instantaneous terrestrial trihedron are given. These angular elements are needed to determine the real pointing angles in a reference system linked to Spacelab.

Vercheval, J.↗

Comet whole-core solution to a stylized 3-dimensional pressurized water reactor benchmark problem with UO{sub 2}and MOX fuel

A stylized pressurized water reactor (PWR) benchmark problem with UO{sub 2} and MOX fuel was used to test the accuracy and efficiency of the coarse mesh radiation transport (COMET) code. The benchmark problem contains 125 fuel assemblies and 44,000 fuel pins. The COMET code was used to compute the core eigenvalue and assembly and pin power distributions for three core configurations. In these calculations, a set of tensor products of orthogonal polynomials were used to expand the neutron angular phase space distribution on the interfaces between coarse meshes. The COMET calculations were compared with the Monte Carlo code MCNP reference solutions using a recently published an 8-group material cross section library. The comparison showed both the core eigenvalues and assembly and pin power distributions predicated by COMET agree very well with the MCNP reference solution if the orders of the angular flux expansion in the two spatial variables and the polar and azimuth angles on the mesh boundaries are 4, 4, 2 and 2. The mean and maximum differences in the pin fission density distribution ranged from 0.28%-0.44% and 3.0%-5.5%, all within 3-sigma uncertainty of the MCNP solution. These comparisons indicate that COMET can achieve accuracy comparable to Monte Carlo. It was also found that COMET's computational speed is 450 times faster than MCNP. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New Possibilities of Positron-Emission Tomography

The reasons for the emergence of the angular distribution of photons generated as a result of annihilation of an electron and a positron in a positron-emission tomograph are investigated. It is shown that the angular distribution of the radiation intensity (i.e., the probability of photon emission at different angles) is a consequence of the Doppler effect in the center-of-mass reference system of the electron and the positron. In the reference frame attached to the electron, the angular distribution of the number of emitted photons does not exists but is replaced by the Doppler shift of the frequency of photons. The results obtained in this study make it possible to extend the potentialities of the positron-emission tomograph in the diagnostics of diseases and to obtain additional mechanical characteristics of human tissues, such as density and viscosity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crossed-beam experiment for the scattering of low- and intermediate-energy electrons from BF{sub 3}: A comparative study with XF{sub 3} (X = C, N, and CH) molecules

Absolute differential cross sections (DCSs) for electron interaction with BF{sub 3} molecules have been measured in the impact energy range of 1.5–200 eV and recorded over a scattering angle range of 15°–150°. These angular distributions have been normalized by reference to the elastic DCSs of the He atom and integrated by employing a modified phase shift analysis procedure to generate integral cross sections (ICSs) and momentum transfer cross sections (MTCSs). The calculations of DCSs and ICSs have been carried out using an independent atom model under the screening corrected additivity rule (IAM-SCAR). The present elastic DCSs have been found to agree well with the results of IAM-SCAR calculation above 20 eV, and also with a recent Schwinger multichannel calculation below 30 eV. Furthermore, in the comparison with the XF{sub 3} (X = B, C, N, and CH) molecules, the elastic DCSs reveal a similar angular distribution which are approximately equal in magnitude from 30 to 200 eV. This feature suggests that the elastic scattering is dominated virtually by the 3-outer fluorine atoms surrounding the XF{sub 3} molecules. The vibrational DCSs have also been obtained in the energy range of 1.5–15 eV and vibrational analysis based on the angular correlation theory has been carried out to explain the nature of the shape resonances. Limited experiments on vibrational inelastic scattering confirmed the existence of a shape resonance with a peak at 3.8 eV, which is also observed in the vibrational ICS. Finally, the estimated elastic ICSs, MTCSs, as well as total cross sections are compared with the previous cross section data available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stabilization of gaze during circular locomotion in light. I. Compensatory head and eye nystagmus in the running monkey

1. A rhesus and cynomolgus monkey were trained to run around the perimeter of a circular platform in light. We call this "circular locomotion" because forward motion had an angular component. Head and body velocity in space were recorded with angular rate sensors and eye movements with electrooculography (EOG). From these measurements we derived signals related to the angular velocity of the eyes in the head (Eh), of the head on the body (Hb), of gaze on the body (Gb), of the body in space (Bs), of gaze in space (Gs), and of the gain of gaze (Gb/Bs). 2. The monkeys had continuous compensatory nystagmus of the head and eyes while running, which stabilized Gs during the slow phases. The eyes established and maintained compensatory gaze velocities at the beginning and end of the slow phases. The head contributed to gaze velocity during the middle of the slow phases. Slow phase Gb was as high as 250 degrees/s, and targets were fixed for gaze angles as large as 90-140 degrees. 3. Properties of the visual surround affected both the gain and strategy of gaze compensation in the one monkey tested. Gains of Eh ranged from 0.3 to 1.1 during compensatory gaze nystagmus. Gains of Hb varied around 0.3 (0.2-0.7), building to a maximum as Eh dropped while running past sectors of interest. Consistent with predictions, gaze gains varied from below to above unity, when translational and angular body movements with regard to the target were in opposite or the same directions, respectively. 4. Gaze moved in saccadic shifts in the direction of running during quick phases. Most head quick phases were small, and at times the head only paused during an eye quick phase. Eye quick phases were larger, ranging up to 60 degrees. This is larger than quick phases during passive rotation or saccades made with the head fixed. 5. These data indicate that head and eye nystagmus are natural phenomena that support gaze compensation during locomotion. Despite differential utilization of the head and eyes in various conditions, Gb compensated for Bs. There are various frames of reference in which an estimate of angular velocity that drives the head and eyes could be based. We infer that body in space velocity (Bs) is likely to be represented centrally to provide this signal.

Non-NASA Center↗

SU-E-T-631: Commissioning and Comprehensive Evaluation of the ArcCHECK Cylindrical Diode Array for VMAT QA

Purpose: Commissioning and comprehensive evaluation of ArcCHECK phantom for dosimetry of VMAT QA, using 6MV photon beam with and without the flattening filter. Methods: ArcCHECK was evaluated for response dependency on linac dose rate, instantaneous dose rate, radiation field size, beam angle and couch insertion. Scatter dose characterization, consistency and symmetry of response, dosimetric accuracy of fixed aperture arcs and clinical VMAT plans were investigated. Measurements were done using TrueBeam™ STx accelerator (Console version 1.6) with a 6 MV beam with and without flattening filter. Reference dose-grids were calculated using Eclipse TPS Analytical Anisotropic Algorithm (AAA version 10.0.39). Planned doses were calculated using symmetric 2mm 3D dose grids with 4 degree angular resolution defaulted to each control point. Gamma evaluations were performed in absolute dose mode, with default normalization to maximum dose in the curved plane and a low dose threshold of 10% to restrict the analysis to clinically relevant areas. Global and local gamma indices at 3mm/3% and 2mm/2% level were computed using SNC software (version 6.0). Results: Results of gamma analysis demonstrated an overall agreement between ArcCHECK measured and TPS calculated reference doses. Field size dependency was within 0.5% of the reference. Dose-rate based dependency was well within 1% of the TPS reference and the angular dependency was ±3% of the reference, as tested for BEV angles. At the level of 3%/3mm, narrow and wide open arcs as well as clinical VMAT cases demonstrated high level of dosimetry accuracy in global gamma passing rates for both 6X and 6F beams. At the level of 2%/2mm two VMAT cases involving the narrow heavily modulated arcs demonstrated lower passing rates. Conclusion: ArcCHECK phantom with latest software and hardware upgrades is suitable for VMAT QA. For higher sensitivity of 2%/2mm gamma analysis, we intend to use it as one of the VMAT QA evaluation metrics.

07 ISOTOPE AND RADIATION SOURCES↗

Use of a Position-Sensitive Multi-Anode Photomultiplier Tube for Finding Gamma-Ray Source Direction

In an urban environment where gamma-ray background counts vary rapidly, it is important to determine the angle (with respect to the detector system) of a discrete gamma-ray–emitting source for localization purposes. We have recently developed a handheld gamma-ray detection system that provides gamma-ray energy spectral data and angular position of the target source. Careful placement and orientation of individual detectors with reference to other detectors in an array can provide improved angular resolution for determining the source position by occlusion mechanism. The objectives of this project were to design and build a prototype, light-weight, hand-held, gamma-ray spectrometer with directional sensitivity. It is important for first responders in a radiological emergency to have an easy-to-use gamma spectrometric detection system that determines the incident gamma-ray energy along with the relative angular position of a point-like radioactive source in a near-field measurement (≤3 meters from the source). The technical challenge of this project, driven by search scenarios for monitoring crowds in a national special security events was to determine the relative angle of a gamma-ray–emitting source (50 μCi strong) at a distance of 3 meters from the detector in 3 minutes. We designed and built small, portable, light-weight directional gamma energy spectrometers using a position-sensitive multi-anode photomultiplier. All of three spectrometers showed remarkable (ΔΘ = ± 2°) sensitivity to relative angular position of the source in near-field laboratory measurements.

position-sensitive photomultiplier tube (PMT), mul↗

Role of higher-multipole deformations in exotic {sup 14}C cluster radioactivity

We have studied nine cases of spontaneous emission of {sup 14}C clusters in the ground-state decays of the same number of parent nuclei from the trans-lead region, specifically from {sup 221}Fr to {sup 226}Th, using the preformed cluster model (PCM) of Gupta and collaborators, with choices of spherical, quadrupole deformation ({beta}{sub 2}) alone, and higher-multipole deformations ({beta}{sub 2}, {beta}{sub 3}, {beta}{sub 4}) with cold ''compact'' orientations {theta}{sup c} of decay products. The calculated {sup 14}C cluster decay half-life times are found to be in nice agreement with experimental data only for the case of higher-multipole deformations ({beta}{sub 2}-{beta}{sub 4}) and {theta}{sup c} orientations of cold elongated configurations. In other words, compared to our earlier study of clusters heavier than {sup 14}C, where the inclusion of {beta}{sub 2} alone, with ''optimum'' orientations, was found to be enough to give the best comparison with data, here for {sup 14}C cluster decay the inclusion of higher-multipole deformations (up to hexadecapole), together with {theta}{sup c} orientations, is found to be essential on the basis of the PCM. Interestingly, whereas both the penetration probability and assault frequency work simply as scaling factors, the preformation probability is strongly influenced by the order of multipole deformations and orientations of nuclei. The possible role of Q value and angular-momentum effects are also considered in reference to {sup 14}C cluster radioactivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Chip-Scale Oscillation-Mode Optomechanical Inertial Sensor Near the Thermodynamical Limits

Modern navigation systems integrate the global positioning system (GPS) with an inertial navigation system (INS), which complement each other for correct attitude and velocity determination. Here, the core of the INS integrates accelerometers and gyroscopes used to measure forces and angular rate in the vehicular inertial reference frame. With the help of gyroscopes and by integrating the acceleration to compute velocity and distance, precision and compact accelerometers with sufficient accuracy can provide small–error location determination. Solid–state implementations, through coherent readout, can provide a platform for high performance acceleration detection. In contrast to prior accelerometers using piezoelectric or capacitive readout techniques, optical readout provides narrow–linewidth high–sensitivity laser detection along with low–noise resonant optomechanical transduction near the thermodynamical limits. Here an optomechanical inertial sensor with an 8.2 µg Hz –1/2 velocity random walk (VRW) at an acquisition rate of 100 Hz and 50.9 µg bias instability is demonstrated, suitable for applications, such as, inertial navigation, inclination sensing, platform stabilization, and/or wearable device motion detection. Driven into optomechanical sustained–oscillation, the slot photonic crystal cavity provides radio–frequency readout of the optically–driven transduction with an enhanced 625 µg Hz –1 sensitivity. Measuring the optomechanically–stiffened oscillation shift, instead of the optical transmission shift, provides a 220× VRW enhancement over pre–oscillation mode detection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Detection of correlated fragments in a sequence of images by superimposed Fourier holograms

The problem of detecting correlated fragments in a sequence of images recorded by the superimposing holograms within the Fourier holography scheme with angular multiplication of a spatially modulated reference beam is considered. The approach to the solution of this problem is based on the properties of the variance of the image sum. It is shown that this problem can be solved by providing a constant distance between the signal and reference images when recording superimposed holograms and a partial mutual correlatedness of reference images. The detection efficiency is analysed from the point of view of estimated image data capacity, the degree of mutual correlation of reference images, and the hologram recording conditions. The results of a numerical experiment under the most complicated conditions (representation of images by realisations of homogeneous random fields) confirm the theoretical conclusions. (holographic memory)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear Diffusion Acceleration of the Least-Squares Transport Equation in Geometries with Voids

In this paper we show the extension of the Nonlinear-Diffusion Acceleration (NDA) to geometries containing small voids using a weighted least-squares (WLS) high order equation. Even though the WLS equation is well defined in voids, the low-order drift diffusion equation was not defined in materials with a zero cross section. This paper derives the necessary modifications to the NDA algorithm. We show that a small change to the NDA closure term and a non-local definition of the diffusion coefficient solve the problems for voids regions. These changes do not affect the algorithm for optical thick material regions, while making the algorithm well defined in optically thin ones. We use a Fourier analysis to perform an iterative analysis to confirm that the modifications result in a stable and efficient algorithm. Numerical results of our method will be presented in the second part of the paper. We test this formulation with a small, one-dimensional test problem. Additionally we present results for a modified version of the C5G7 benchmark containing voids as a more complex, reactor like problem. We compared our results to PDT, Texas A&M’s transport code, utilizing a first order discontinuous formulation as reference and the self-adjoint angular flux equation with void treatment (SAAFτ ), a different second order form. The results indicate, that the NDA WLS performed comparably or slightly worse then the asymmetric SAAFτ , while maintaining a symmetric discretization matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the accuracy of Hipparcos using binary stars as a calibration tool

Stellar binary systems, specifically those that present the most accurate available orbital elements, are a reliable tool to test the accuracy of astrometric observations. We selected all 35 binaries with these characteristics. Our objective is to provide standard uncertainties for the positions and parallaxes measured by Hipparcos relative to this trustworthy set, as well as to check supposed correlations between several parameters (measurement residuals, positions, magnitudes, and parallaxes). In addition, using the high-confidence subset of visual–spectroscopic binaries, we implemented a validation test of the Hipparcos trigonometric parallaxes of binary systems that allowed the evaluation of their reliability. Standard and non-standard statistical analysis techniques were applied in order to achieve well-founded conclusions. In particular, errors-in-variables models such as the total least-squares method were used to validate Hipparcos parallaxes by comparison with those obtained directly from the orbital elements. Previously, we executed Thompson's τ technique in order to detect suspected outliers in the data. Furthermore, several statistical hypothesis tests were carried out to verify if our results were statistically significant. A statistically significant trend indicating larger Hipparcos angular separations with respect to the reference values in 5.2 ± 1.4 mas was found at the 10{sup −8} significance level. Uncertainties in the polar coordinates θ and ρ of 1.°8 and 6.3 mas, respectively, were estimated for the Hipparcos observations of binary systems. We also verified that the parallaxes of binary systems measured in this mission are absolutely compatible with the set of orbital parallaxes obtained from the most accurate orbits at least at the 95% confidence level. This methodology allows us to better estimate the accuracy of Hipparcos observations of binary systems. Indeed, further application to the data collected by Gaia should yield a standard procedure to compare both data sets.

79 ASTRONOMY AND ASTROPHYSICS↗

Observations of heavy energetic ions far upstream from Comet Halley

On March 25, 1986, when the ICE spacecraft came within 28 million km of the nucleus of comet Halley, and for several days around this time, bursts of heavy ions were observed by the ICE energetic ion experiment. The bursts were observed only during periods when the solar wind velocity was considerably higher than its nominal value. The characteristics of these ions, in particular their anisotropies, were examined. Using the well known formulae for transformation of distributions from the solar wind frame of reference to the spacecraft frame, the angular distributions expected from either protons, or heavy ions from the water group, were studied, showing that the measurements are consistent with heavy ions, and not with protons. Other sources of heavy ions are considered, and the most likely source of these ions is comet Halley.

Sanderson, T. R.↗

Differential CCD photometry of faint asteroids in crowded star fields and nonphotometric sky conditions

It is demonstrated that the use of an imaging CCD detector array allows photometric observations of comparatively faint asteroids moving rapidly through a complex background of star images. The shortage of observing time is alleviated by taking advantage of the presence of comparison stars that are observed simultaneously on the CCD imaging area and at small angular separations from the asteroid. These reference stars allow the effects of thin cirrus clouds or haze to be compensated to a degree adequate for the acquisition of scientifically original data.

Wisniewski, W. Z.↗

A Proposed Frequency Synthesis Approach to Accurately Measure the Angular Position of a Spacecraft

This article describes an approach for measuring the angular position of a spacecraft with reference to a nearby calibration source (quasar) with an accuracy of a few tenths of a nanoradian using a very long baseline interferometer of two antennas that measures the interferometer phase with a modest accuracy. It employs (1) radio frequency phase to determine the spacecraft position with high precision and (2) multiple delay measurements using either frequency tones or telemetry signals at different frequency spacings to resolve ambiguity of the location of the fringe (cycle) containing the direction of the spacecraft.

Bagri, D. S.↗