Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Building Technologies Office 03.02.02.38 Milestone Report—Compressor Technology Development for Refrigerants with <150 Global Warming Potential

The major purpose of this project is to enable the development of compressors specifically designed for compatibility with low–global warming potential (GWP) refrigerants (with GWP values below 150). These compressors are intended for applications in residential and light commercial air-conditioning and heat pump systems. This report contains an exhaustive review of the existing literature with the intention of discerning the most efficacious methodologies currently in use for compressor modeling. This fundamental stage was designed to foster a comprehensive understanding of the intricate dynamics and mechanics of compressors. As a result, a model (PDSim) was selected to simulate scroll, rotary and linear compressor technologies.

42 ENGINEERING↗

Low-Cost Electrochemical Compressor (ECC) Utilizing Green Refrigerants for HVAC Applications [Slides]

HVAC systems account for approximately 14 Quads or primary energy annually, or nearly 30% of all energy used in the U.S. commercial and residential buildings. Electrochemical compression (ECC) is a transformative solid-state technology and ECC based HVAC systems could result in 40% less energy use. The goal of the project was to develop the most efficient, noiseless, and most environmentally friendly cooling system based on integrating 2 (two) technologies: a) electrochemical compressors (ECC) to replace mechanical compressors for use in building heating, ventilation, and air conditioning (HVAC) applications and b) Ionic Liquid Desiccant Systems. The overall objective was to develop and build a scalable ILD/ECC-based air conditioning system operating with a COP of 4.5, with a price premium of $70 installed per kBTU/hr.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Study of Liquid Piston Compression Using Large-Eddy Simulation and Volume-of-Fluid Approach

Efforts to increase the efficiency of residential and commercial air conditioners and heat pumps have demonstrated that the compressor accounts for most of the system’s electrical energy usage. Therefore, the efficiency of this component should be improved to reduce its energy usage. The US Department of Energy’s Oak Ridge National Laboratory developed a near-isothermal liquid piston compressor (LPC) that uses propylene glycol (PG) to compress CO2. This report presents numerical studies of the LPC in which the compression chamber fills with injected PG from the bottom inlet. Numerical simulations were performed using the large-eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) subgrid-scale model coupled with the multiphase volume-of-fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfer within the compression chamber. In this effort, effects of boundary conditions applied to the LES-VOF calculations (e.g., no wall, an adiabatic wall, and a wall with a heat flux subscribed) to the overall pressure and temperature of CO2 gas as well as the transient evolution of flow and heat transfer evolution within the compression chamber are investigated and discussed. It was found that the LES calculation with no wall have shown no dynamical flow patterns and the volume-averaged temperature of CO2 increased from 305 to 392.7 K, while LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO2 temperatures. Results of LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO2 gas layers and circulation flow patterns within the chamber that contribute to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor.

Nguyen, Thien D.↗

Low-cost Retrofit Kit for Integral Reciprocating Compressors (IRCs) to Reduce Emissions and Enhance Efficiency

Methane emissions from natural gas engines within the oil and gas industry pose a significant environmental challenge, contributing approximately 34.1 MMTCO2 eq to the total of 239 MMTCO2 eq of methane emissions in 2021, according to the EPA report. In response to this pressing issue, a collaborative effort involving the University of Oklahoma and key industry partners—WAGO Automation, Mid Continental Rental, Elipsa, and Perscient—has resulted in the development of a retrofit kit designed to reduce emissions from integral reciprocating compressors (IRCs), which are integrated compressors and engines. The retrofit kit developed comprises an Air Management System (AMS), Integrated Sensors, and a Cloud-Connected Control Unit with Graphical User Interface (GUI)/Human-Machine Interface (HMI). This solution enhances operational efficiency, reduces emissions, and expands the operational envelope of IRCs in the natural gas industry. The project successfully completed all tasks, including the installation of a full-size IRC at a designated site in Oklahoma, the development of an optimized AMS, integration of sensors, and implementation of a data acquisition system. Significant achievements include a notable reduction in CH 4 emissions, up to 84% at specific loads, and the successful deployment of the retrofit kit in diverse field conditions. The system's capabilities were enhanced through the creation of a feedback control algorithm for the AMS using a correlation matrix illustrating relationships between engine parameters, and the design of a predictive and preventive maintenance platform. The project concluded with the deployment of the entire retrofit kit to another location, confirming its effectiveness in reducing emissions and enhancing IRC performance. The comprehensive solution offers valuable benefits for IRCs, making them invaluable assets in the natural gas industry.

03 NATURAL GAS↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units With Exhaust Air Energy Recovery

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. This measure replaces gas furnace and electric resistance rooftop units with high-efficiency variable speed heat pump rooftop units (HP-RTU) that include exhaust air heat or energy recovery. The measure uses the same assumptions and technology as the variable speed HP-RTU measure from EUSS 2023 release 1 but adds energy recovery to precondition outdoor ventilation air to reduce HVAC loads. The HP-RTU compressor lockout temperature is modeled as 0 degrees Fahrenheit; below this temperature, the heat pump is set to shut off. The unit is sized based on the design cooling loads, with backup electric resistance heating addressing any remaining loads including heating hours below the compressor lockout temperature when there is no heat pump heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Isothermal Compressor Computational Fluid Dynamics Simulations (Final Report)

Carnot Compression is a startup company developing an innovative technology for air and gas compression. This technology is inherently oil-free and isothermal due to the use of water to simultaneously compress and cool the gas throughout the process. Isothermal gas compression eliminates the need to cool the compressed gas so it may lead to significant energy savings. The development of Carnot’s isothermal compressor is limited by the lack of insight into the flow and detailed behavior of the fluids (water and air/gas) inside the air end. Previous and current attempts at Computational Fluid Dynamics (CFD) simulations by Carnot have been unable to provide the level of accuracy required to use simulations for technology development. In this Cooperative Research and Development Agreement (CRADA) project, Oak Ridge National Laboratory (ORNL) used the CFD package Star-CCM+ to successfully develop a CFD simulation, providing the much-needed insight required to speed up the development. The work is intended to enable Carnot Compression to unlock its technology potential to a level sufficient for commercialization of the intended first product. The work will also prepare Carnot to scale the technology to much larger and more energy intensive applications, positioning it to broaden the product applications. Successful development of the technology has the potential to result in 20% or more efficiency gains for compression processes, or about $3 billion in annual energy savings potential for the U.S. alone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nonlinear post-compression to sub-20 fs using a single-stage multipass cell filled with ambient air

Noble gas-filled multipass cells have proven to be very effective in compressing high-energy, hundreds-of-femtoseconds pulses down to tens of femtoseconds. Molecular gases can be an attractive alternative to noble gases since they provide additional Raman nonlinearities that can be much stronger than the electronic Kerr nonlinearity and can therefore enable more spectral broadening and shorter compressed pulses. Air at atmospheric pressure offers molecular gases in their simplest format, with both easy access and no costs for implementing a gas chamber. Here we demonstrate a single-stage, air-filled multipass cell that spectrally broadens 145- μ J, 185-fs pulses with >90% throughput, with a small fraction of the output compressed to sub-20 fs using a prism-pair compressor. The multipass cell uses standard broadband mirrors without dispersion engineering and ambient air as the nonlinear medium, making it the simplest and most cost-effective solution for generating few-cycle femtosecond pulses.

47 OTHER INSTRUMENTATION↗

Long-Term Monitoring the Damage Performance of Multilayer Dielectric Grating Samples Residing Inside the Compressor Chamber of the OMEGA EP Laser

Understanding of the laser-induced damage threshold and impact of air–vacuum cycling of the optical components in short-pulse laser systems is of fundamental importance. We report the results of a damage-testing campaign that monitored representative pulse compression grating samples that were positioned inside the OMEGA EP grating compressor vacuum chamber during normal operation and routinely damage tested on every quarterly vent for a period of about 10 years. Here, the evolution of their damage resistance under 10-ps and 100-ps pulse lengths are associated with a significant degradation of the laser-induced damage thresholds, which is comparatively larger at 100 ps, is described.

42 ENGINEERING↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

Bahar, Bamdad↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of powertrain system decarbonization using electrically assisted turbocharging and hybridization in off-road vehicles

In recent years, the causes, effects, and existential threat of a global anthropogenic climate shift have drawn significant attention and stimulated mitigation efforts from all genres of scientific, political, and industrial bodies. The greenhouse effect and the detrimental environmental impact of excess greenhouse gas (GHG) emissions, like carbon dioxide, is well studied and targeted as the primary culprit for aversive action. However, some fields exist where reducing GHG emissions is met by considerable challenges. One such field is the production and operations of off-road vehicles. Applications of these vehicles are highly diverse and are often characterized by rugged, especially transient, and power intensive duty cycles that make one-fits-all vehicle configuration solutions impractical. This research surveys existing literature to identify the modern technologies packages and challenges that face development and configuration of powertrain systems which currently navigate the regulated emissions and unique duty cycle requirements of this market space. A novel powertrain concept is proposed and evaluated with respect to the pinnacle objectives of load performance improvement, criteria pollutant reduction, and reducing the life cycle GHG intensity of its operation. A sure-fire path to vehicular GHG reduction is through improving the fuel efficiency of internal combustion engines (ICEs), an entrenched component of the off-road vehicle sector. Unfortunately, this is more easily said than done. An approach that has proven successful in this endeavor is engine downsizing and turbocharging, where a larger engine is replaced with a smaller one with added air system boosting via turbocharger to reduce frictional and pumping losses while also enabling access to additional fuel energy. However, practical realization of these potential benefits is often impeded by the transient response capability of the smaller engine across the operating space. For this reason, downsized ICE powertrains have turned to electrified forced induction systems (EFISs) for a decoupling of exhaust energy and engine speed from boost capability. Platformed on 48V hybrid technology, these systems introduce the need for more sophisticated controls around the engine gas-exchange process for the management of boost performance and exhaust gas emissions. On this account, simulation studies utilizing a GT-POWER model of a turbocharged 4.5 L engine outfit with an EFIS using an electrically driven compressor (eBooster®) are conducted to provide insight into the performance of this air handling architecture on an off-road engine. The results show that improvement in transient torque response time in sync with reduction in engine-out soot and NOx emissions are possible with an engine recalibration that leverages the transient air-fuel ratio authority of the eBooster®. Benefits are further demonstrated when duty cycle simulations of the 48V mild-hybrid engine concept are exercised, showing an acute decrease in cumulative fuel usage and soot production. Powertrain hybridization is another technological pathway achieving pronounced GHG reduction successes in modern on-road vehicle applications through integration of Li-ion battery technology. In the off-road vehicle segment, a review of available literature concludes that hybridized architectures are present but generally lack the depth of technologies that have both high specific energy and power capabilities, and thus are limited in their inclusion of Li-ion batteries for ICE assistance and enhanced energy storage capability. Therefore, building on the mild-hybrid engine results, the downsized and eBoosted engine concept was integrated into a larger high-voltage battery-hybrid series-electric powertrain system. Hybrid powertrain parameter sensitivity studies were carried out in a numerical charge-sustaining framework, providing novel insights into power flows between the battery and the engine and how their respective capabilities and operation contribute to GHG and criteria pollutant emissions of diverse duty cycles. Application of supervisory power management introduced robustness into the power sourcing and battery SOC control process and showed that optimum specification of battery properties can yield synergies between GHG emissions and battery energy capacity. Furthermore, examination of recent literature on Li-ion batteries has shown that pack manufacturing is a highly energy intensive process, thereby producing considerable quantities of GHGs that scale with energy storage capacity. Also scaling with a battery’s energy storage capacity is its investment cost. In consideration of these factors, an inclusive technoeconomic and GHG life cycle analysis is conducted. This analysis systematically compares the carbon footprint and total cost of ownership associated with the proposed hybrid powertrain concept to reference and alternative powertrain configurations, facilitating a thorough evaluation of the decarbonization effectiveness and economic viability.

99 GENERAL AND MISCELLANEOUS↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding airflow pattern and temperature distribution in domestic refrigerators – A review analyzing recent developments and bridging knowledge gaps

Refrigerators have become an essential appliance in every household, and they consume approximately 30% of total electricity among other domestic appliances such as clothes washers, dryers, and air conditioners. With the refrigerator’s comparatively high energy consumption compared with other appliances, existing research has mainly focused on improving the energy efficiency of refrigerators by changing the design of the compressor, heat exchanger, refrigerant, and insulation. However, previous studies have paid very little attention to the research and development of the temperature distribution in the refrigerator, which is a key parameter in determining energy consumption and food safety. Therefore, this review aims to present an overview of recent design developments to improve the temperature distribution and air circulation in domestic refrigerators, including static refrigerators and no-frost refrigerators. Herein, this review article discusses the various operation and design factors that can affect the air circulation and temperature uniformity of the refrigerator, including shelf arrangement, the compressor on/off cycle, thermostat settings, evaporator design, ambient conditions, door opening frequency, and product loading temperatures. Additionally, this review provides a summary of the advanced vapor compression cycle based refrigerators that are expected to provide better energy efficiency and independent temperature control in freezer and refrigerator compartments. This review elaborates on the significance of improving the performance of the domestic refrigerator in terms of temperature distribution and air circulation.

42 ENGINEERING↗

Enabling off-highway diesel engine downsizing and performance improvement using electrically assisted turbocharging

Internal combustion engine (ICE) downsizing through various turbocharging configurations is generally known by the powertrain design community as an effective means to reduce frictional losses, increase waste heat recovery, and improve fuel efficiency while increasing engine power density. However, often is the case that turbocharging strategies, including variable geometry turbochargers, and regulated two-stage turbochargers, incur the performance tradeoff between transient response and fuel economy (pumping losses) at high engine speeds. For off-highway vehicles having particularly transient and high-powered duty cycles, efforts to improve this tradeoff and increase operational flexibility have turned to evaluating various electrified air system architectures. In this study, a 4.5 L diesel-ICE configured with an electrically driven compressor (eBooster ® ) is placed in series with a conventional turbocharger and integrated into a 48 V mild-hybrid powertrain architecture. The objective of this powertrain configuration is to enable engine downsizing by 34%, replacing the current 6.8 L ICE platform with the hybridized 4.5 L ICE concept. The commercial 1-D simulation software GT-SUITE is used for powertrain system development and system optimization. Development and validation of the GT-SUITE model and air system controls is concurrently supported through experimental data collection. The simulation model development includes using machine learning methods for optimizing exhaust gas dilution, injection timing, and eBooster ® power to improve steady-state and transient brake-specific fuel consumption while minimizing criteria pollutant emissions. It was found that total specific fluid consumption over the standardized non-road transient engine duty cycle could be reduced by 18% over the current 6.8 L engine by using an optimized eBoosted 4.5 L engine. The hybridized 4.5 L engine concept concurrently showed sufficient transient response capability and nearly an order of magnitude reduction in duty cycle total soot production.

25 ENERGY STORAGE↗

Analysis of Energy Savings and CO2 Emission Reduction Contribution for Industrial Facilities in USA

Abstract Energy audits can identify energy consumptions, energy costs of the facility and evolve to develop measures to maximize efficiency, optimize supply energy, and eliminate waste. This paper investigates the potential energy savings at 20 different industrial sectors with 152 assessments for various facilities in Wisconsin, USA. On average, eight energy recommendations were suggested and applied in each facility. This paper provides a detailed guideline for each industry in terms of eight different energy categories: heating, ventilation, and air conditioning (HVAC) systems, heat recovery systems, electrical demand management, and utility bills, motors, compressors, waste management, and productivity enhancement, lighting, besides building envelope. In total, the energy savings were as follows: 98 million kWh in the shape of electricity, 561 billion British thermal units (BTUs) gas savings, 44 million gallons water savings, and 2-million-pound solid waste savings. Based on these savings, a 100-thousand-ton reduction in carbon dioxide emissions was obtained.

Energy & Fuels↗