Energy Savings Potential and Research, Development, & Demonstration Opportunities for Residential Building Heating, Ventilation, and Air Conditioning Systems

This report is an assessment of 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, descriptions of technical maturity, descriptions of non-energy benefits, descriptions of current barriers for market adoption, and descriptions of the technology's applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential emission savings from refrigeration and air conditioning systems by using low GWP refrigerants

Refrigeration and air conditioning systems have high, negative environmental impacts due to refrigerant charge leaks from the system and their corresponding high global warming potential. Thus, many efforts are in progress to obtain suitable low GWP alternative refrigerants and more environmentally friendly systems for the future. In addition, the system’s life cycle climate performance (LCCP) is a widespread metric proposed for the evaluation of the system’s environmental impact.

54 ENVIRONMENTAL SCIENCES↗

Numerical Simulation Studies of Ultrasonic De-Icing for Heating, Ventilation, Air Conditioning, and Refrigeration Structures

Ice accumulation on heating, ventilation, air conditioning, and refrigeration (HVACR) structures presents significant operational challenges. These challenges include reduced efficiency, increased energy consumption, and potential damage to equipment. Traditional de-icing methods, such as chemical treatments, mechanical scraping, or heating-based techniques, are often labor-intensive, costly, and environmentally harmful. Here, this study uniquely investigates ultrasonic de-icing as an energy-efficient alternative for HVACR applications, focusing on the specific structural geometries found in these systems. A comprehensive numerical simulation framework was developed using finite element analysis to explore ultrasonic wave propagation across four distinct HVACR structures. Key parameters such as ultrasonic frequency, power levels, and the number and placement of actuators were examined for their impact on ice detachment efficiency. Results from simulations on a plate structure reveal that ultrasonic excitation can propagate effectively across large areas (at least 150 × 150 mm), enhancing the de-icing coverage. Lower frequency (e.g., 30 to 45 kHz) excitation results in greater displacement, improving de-icing performance, while increased actuator numbers with the same total power input also enhance effectiveness. Two actuators seem sufficient for the de-icing of a 300 × 300 mm plate. For tube-and-fin structures, specific high-power ultrasonic frequencies selectively excite the fin plates, demonstrating efficient ice removal when actuated on the tube. However, optimal performance requires careful design of actuator placement and vibration modes to accommodate the irregular shapes of these structures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

This paper presents a freely available Modelica library for building heating, ventilation and air conditioning systems. The library is based on the Modelica.Fluid library. It has been developed to support research and development of integrated building energy and control systems. The primary applications are controls design, energy analysis and model-based operation. The library contains dynamic and steady-state component models that are applicable for analyzing fast transients when designing control algorithms and for conducting annual simulations when assessing energy performance. For most models, dimensional analysis is used to compute the performance for operating points that differ from nominal conditions. This allows parameterizing models in the absence of detailed geometrical information which is often impractical to obtain during the conceptual design phase of building systems. In the first part of this paper, the library architecture and the main classes are described. In the second part, an example is presented in which we implemented a model of a hydronic heating system with thermostatic radiator valves and thermal energy storage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Conditioning Systems Fault Detection and Diagnosis-Based Sensing and Data-Driven Approaches

The air conditioning (AC) system is the primary building end-use contributor to the peak demand for energy. The energy consumed by this system has grown as fast as it has in the last few decades, not only in the residential section but also in the industry and transport sectors. Therefore, to combat energy crises, urgent actions on energy efficiency should be taken to support energy security. Consequently, the faults in AC system components increase energy consumption due to the degradation of the system’s performance and the losses in the energy conversion procedure. In this work, AC system fault detection and diagnosis (FDD) methods are investigated to propose analytic tools to identify faults and provide solutions to those problems. The analysis of existing work shows that data-driven approaches are more accurate for both soft and hard fault detection and diagnosis in AC systems. Therefore, the proposed methods are not accurate for simultaneous fault detection, while in some works, authors tested the method with several faults separately without investigating scenarios that combine more than one fault. Moreover, this study shows that integrating data-driven approaches requires deploying an optimal sensing and measurement architecture that can detect a maximum number of faults with minimally deployed sensors. The new sensing, information, and communication technologies are discussed for their integration in AC system monitoring in order to optimize system operation and detect faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Contact Resistance and Fin Effectiveness of Enhanced, Brazed "Dogbone" Fin and Serpentine Tube Heat Exchangers for Air Conditioning and Heat Pump Applications

The energy consumption due to air conditioning is projected to increase by 1.3 and 4.5 times by 2050 compared to 2010 for members and non-members of the Organization of Economic Coordination and Development (OECD), respectively. Greenhouse Gas (GHG) emissions must be carefully managed to minimize their hazardous contribution to climate change. Air conditioners (AC) and heat pumps (HP) contribute with direct GHG emissions through systemic refrigerant leakage, which consequently degrades the system’s performance and therefore increases its indirect GHG emissions as well. To address this issue, the goals of new systems include minimizing leakage risk, using low global warming potential (GWP) refrigerants such as natural refrigerants, and increasing system efficiency. This paper presents part of the efforts in the development of a brazed “dogbone” fin to continuous serpentine tube heat exchanger (HX) for AC/HP applications. The main advantages of such technology are: 1) The potential to reduce 90% or more of the tube return-bends brazed joints compared to conventional tube-fin heat exchangers, thus minimizing leakage vulnerability, enabling the use of natural refrigerants like Propane and Ammonia that carry other concerning risks of flammability and toxicity ; and 2) The brazed fin to the tube joints should yield very low contact resistance. In order to quantify and estimate the impacts of contact resistance and fin effectiveness, a numerical-experimental study is investigated. The novel enhanced brazed “dog-bone” fin is compared to an equivalent pressure expanded fin. The results showed that the expanded fin has consistently greater effective heat transfer but greater contact resistance as well. Furthermore, the brazed fins have up to 20% lower pressure drop. The trade-off comparison shows that the thermal-hydraulic ratio between the two fins is equivalent for air velocities below 2m/s; for greater velocities, however, the expanded fin is favored since it has less fin efficiency penalty. For HVAC&R applications, the air velocities are typically low which makes the proposed technology competitive and a viable option in the pursuit of refrigerant leakage reduction.

30 DIRECT ENERGY CONVERSION↗

Reduction of Eu{sup 3+} to Eu{sup 2+} in MAl{sub 2}Si{sub 2}O{sub 8} (M=Ca, Sr, Ba) in air condition

In general, the reduction of Eu{sup 3+} to Eu{sup 2+} in solids needs an annealing process in a reducing atmosphere. In this paper, it is of great interest and importance to find that the reduction of Eu{sup 3+} to Eu{sup 2+} can be realized in a series of alkaline-earth metal aluminum silicates MAl{sub 2}Si{sub 2}O{sub 8} (M=Ca, Sr, Ba) just in air condition. The Eu{sup 2+}-doped MAl{sub 2}Si{sub 2}O{sub 8} (M=Ca, Sr, Ba) powder samples were prepared in air atmosphere by Pechini-type sol-gel process. It was found that the strong band emissions of 4f{sup 6}5d{sup 1}-4f{sup 7} from Eu{sup 2+} were observed at 417, 404 and 373 nm in air-annealed CaAl{sub 2}Si{sub 2}O{sub 8}, SrAl{sub 2}Si{sub 2}O{sub 8} and BaAl{sub 2}Si{sub 2}O{sub 8}, respectively, under ultraviolet excitation although the Eu{sup 3+} precursors were employed. In addition, under low-voltage electron beam excitation, Eu{sup 2+}-doped MAl{sub 2}Si{sub 2}O{sub 8} also shows strong blue or ultraviolet emission corresponding to 4f{sup 6}5d{sup 1}-4f{sup 7} transition. The reduction mechanism from Eu{sup 3+} to Eu{sup 2+} in these compounds has been discussed in detail. - Graphical abstract: It is of great importance to find that the reduction of Eu{sup 3+} to Eu{sup 2+} can be realized in a series of alkaline-earth metal aluminum silicates MAl{sub 2}Si{sub 2}O{sub 8} (M=Ca, Sr, Ba) just in air condition.

36 MATERIALS SCIENCE↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aggregated Modeling and Control of Air Conditioning Loads for Demand Response

Demand response is playing an increasingly important role in the efficient and reliable operation of the electric grid. Modeling the dynamic behavior of a large population of responsive loads is especially important to evaluate the effectiveness of various demand response strategies. In this paper, a highly-accurate aggregated model is developed for a population of air conditioning loads. The model effectively includes statistical information of the population, systematically deals with load heterogeneity, and accounts for second-order dynamics necessary to accurately capture the transient dynamics in the collective response. Based on the model, a novel aggregated control strategy is designed for the load population under realistic conditions. The proposed controller is fully responsive and achieves the control objective without sacrificing end-use performance. The proposed aggregated modeling and control strategies are validated through realistic simulations using GridLAB-D. Extensive simulation results indicate that the proposed approach can effectively manage a large number of air conditioning systems to provide various demand response services, such as frequency regulation and peak load reduction.

Zhang, Wei↗

Colonization by Cladosporium spp. of painted metal surfaces associated with heating and air conditioning systems

Cladosporium cladosporioides and C. hebarum colonized painted metal surfaces of covering panels and register vents of heating, air conditioning and ventilation systems. Hyphae penetrated the paint film and developed characteristic conidiophores and conidia. The colonies were tightly appressed to the metal surface and conidia were not readily detectable via standard air sampling procedures.

NASA Program Environmental Health↗

Technology evaluation of heating, ventilation, and air conditioning for MIUS application

Potential ways of providing heating, ventilation, and air conditioning for a building complex serviced by a modular integrated utility system (MIUS) are examined. Literature surveys were conducted to investigate both conventional and unusual systems to serve this purpose. The advantages and disadvantages of the systems most compatible with MIUS are discussed.

Gill, W. L.↗

Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere,1 mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-Cab Air Quality of Trucks Air Conditioned and Kept in Electrified Truck Stop

At night, long-haul truck drivers rest inside the cabins of their vehicles. Therefore, the in-cab air quality while air conditioning (A/C) is being provided can be a great concern to the drivers health. The effect of using different A/C methods [truck's A/C, auxiliary power unit (APU), and truck stop electrification (TSE) unit] on in-cab air quality of a heavy-duty diesel vehicle was investigated at an electrified truck stop in the El Paso, Texas, area. The research team measured the in-cabin and the ambient air quality adjacent to the parked diesel truck as well as emissions from the truck and an APU while it was providing A/C. The measured results were compared and analyzed. On the basis of these results, it was concluded that the TSE unit provided better in-cab air quality while supplying A/C. Furthermore, the truck and APU exhaust emissions were measured, and fuel consumption of the truck (while idling) and the APU (during operation) were compared. The results led to the finding that emissions from the APU were less than those from the truck's engine idling, but the APU consumed more fuel than the engine while providing A/C under given conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Light-Duty Vehicle Air Conditioning Fuel Use and Impact of Solar/Thermal Control Technologies

To reduce fuel consumption and carbon dioxide (CO2) emissions from mobile air conditioning (A/C) systems, 'U.S. Light-Duty Vehicle Greenhouse Gas Emissions and Corporate Average Fuel Economy Standards' identified solar/thermal technologies such as solar control glazings, solar reflective paint, and active and passive cabin ventilation in an off-cycle credit menu. National Renewable Energy Laboratory (NREL) researchers developed a sophisticated analysis process to calculate U.S. light-duty A/C fuel use that was used to assess the impact of these technologies, leveraging thermal and vehicle simulation analysis tools developed under previous U.S. Department of Energy projects. Representative U.S. light-duty driving behaviors and weighting factors including time-of-day of travel, trip duration, and time between trips were characterized and integrated into the analysis. In addition, U.S. weather conditions weighted based on light-duty vehicle registrations were generated and used for the analysis. Three representative vehicle types for the light-duty fleet were selected based on registration data containing vehicle size information. These key inputs were used to support a weighted parametric analysis that quantified vehicle thermal load, vehicle accessory load, and vehicle fuel use. This analysis estimates that 7.6 billion gallons of fuel a year are used in the United States for vehicle A/C, equivalent to 6.1% of the total national light-duty vehicle fuel use. This equates to 30.0 gallons/year per vehicle or 23.5 grams CO 2 per mile (g/mi) for an average U.S. light-duty vehicle. A/C is a significant contributor to national fuel use; therefore, technologies that reduce A/C loads have an opportunity to reduce fuel consumption, reduce imported oil, and improve energy security. Implementing solar control glass reduced the CO 2 emissions by 2.0 g/mi and the reduction due to solar reflective paint was 0.8 g/mi. The active and passive ventilation strategies as defined in this analysis only reduced emissions by 0.1 and 0.2 g/mi, respectively. This analysis shows the potential to reduce operational costs, A/C fuel use, and CO 2 emissions by implementing advanced vehicle climate control technologies including the solar/thermal technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Heating, Ventilating, and Air-Conditioning: Recent Advances in Diagnostics and Controls to Improve Air-Handling System Performance

The performance of air-handling systems in buildings needs to be improved. Many of the deficiencies result from myths and lore and a lack of understanding about the non-linear physical principles embedded in the associated technologies. By incorporating these principles, a few important efforts related to diagnostics and controls have already begun to solve some of the problems. This paper illustrates three novel solutions: one rapidly assesses duct leakage, the second configures ad hoc duct-static-pressure reset strategies, and the third identifies useful intermittent ventilation strategies. By highlighting these efforts, this paper seeks to stimulate new research and technology developments that could further improve air-handling systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Heating, Ventilation, and Air Conditioning Systems

This report covers an assessment of 182 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, description of technical maturity, description of non-energy benefits, description of current barriers for market adoption, and description of the technology’s applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

aerosol duct sealing↗