Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Aerodynamic performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Experimental quiet engine program aerodynamic performance of fan A

The aerodynamic component test results are presented of fan A, one of two high-bypass-ratio, 1160 feet per second single-stage fans, which was designed and tested as part of the NASA Experimental Quiet Engine Program. This fan was designed to deliver a bypass pressure ratio of 1.50 with an adiabatic efficiency of 86.5% at a total fan flow of 950 lb/sec. It was tested with and without inlet flow distortion. A bypass total-pressure ratio of 1.52 and an adiabatic efficiency of 88.3% at a total fan flow of 962 lb/sec were actually achieved. An operating margin of 12.4% was demonstrated at design speed.

Giffin, R. G.

Aerodynamic performance of high turning core turbine vanes in a two dimensional cascade

Experimental and theoretical aerodynamic performance data are presented for four uncooled high turning core turbine vanes with exit angles of 74.9, 75.0, 77.5, and 79.6 degrees in a two dimensional cascade. Data for a more conservative 67.0 degree vane are included for comparison. Correction of the experimental aftermix kinetic energy losses to a common 0.100 centimeter trailing edge thickness yields a linear trend of increased loss from 0.020 to 0.025 as the vane exit angle increases from 67.0 to 79.6 degrees. The theoretical losses show a similar trend. The experimental and theoretical vane surface velocity distributions generally agree within approximately five percent, although the suction surface theoretical velocities are generally higher than the experimental velocities as the vane exit angle increases.

Schwab, J. R.

Cold-air annular-cascade investigation of aerodynamic performance of cooled turbine vanes. 2: Trailing-edge ejection, film cooling, and transpiration cooling

The aerodynamic performance of four different cooled vane configurations was experimentally determined in a full-annular cascade at a primary- to coolant-total-temperature ratio of 1.0. The vanes were tested over a range of coolant flow rates and pressure ratios. Overall vane efficiencies were obtained and compared, where possible, with the results obtained in a four-vane, annular-sector cascade. The vane efficiency and exit flow conditions as functions of radial position were also determined and compared with solid (uncooled) vane results.

Goldman, L. J.

Reasons for low aerodynamic performance of 13.5-centimeter-tip-diameter aircraft engine starter turbine

The reasons for the low aerodynamic performance of a 13.5 cm tip diameter aircraft engine starter turbine were investigated. Both the stator and the stage were evaluated. Approximately 10 percent improvement in turbine efficiency was obtained when the honeycomb shroud over the rotor blade tips was filled to obtain a solid shroud surface. Efficiency improvements were obtained for three rotor configurations when the shroud was filled. It is suggested that the large loss associated with the open honeycomb shroud is due primarily to energy loss associated with gas transportation as a result of the blade to blade pressure differential at the tip section.

Haas, J. E.

Aerodynamic performance of high turning core turbine vanes in a two-dimensional cascade

Experimental and theoretical aerodynamic performance data are presented for four uncooled high turning core turbine vanes with exit angles of 74.9, 75.0, 77.5, and 79.6 degrees in a two-dimensional cascade. Data for a more conservative 67.0 degree vane are included for comparison. Corection of the experimental aftermix kinetic energy losses to a common 0.100 centimeter trailing edge thickness yields a linear trend of increased loss from 0.020 to 0.025 as the vane exit angle increases from 67.0 to 79.6 degrees. The theoretical losses show a similar trend. The experimental and theoretical vane surface velocity distributions generally agree within approximately five percent, although the suction surface theoretical velocities are generally higher than the experimental velocities as the vane exit angle increases.

Schwab, J. R.

Cooled-turbine aerodynamic performance prediction from reduced primary to coolant total-temperature-ratio results

The prediction of the cooled aerodynamic performance, for both stators and turbines, at actual primary to coolant inlet total temperature ratios from the results obtained at a reduced total temperature ratio is described. Theoretical and available experimental results were compared for convection film and transpiration cooled stator vanes and for a film cooled, single stage core turbine. For these tests the total temperature ratio varied from near 1.0 to about 2.7. The agreement between the theoretical and the experimental results was, in general, reasonable.

Goldman, L. J.

Aerodynamic Performance and Acoustic Measurements of a High-Lift Propeller in an Isolated Configuration

A series of aerodynamic performance and acoustic measurements has been made on a high-lift propeller intended for utilization on a distributed electric propulsion (DEP) aircraft. Tests were performed in the NASA Langley Low Speed Aeroacoustic Wind Tunnel (LSAWT), which has recently undergone a capability enhancement for the testing of small propellers/rotors and small unmanned aircraft system (UAS) platforms. The objectives of this testing campaign are two-fold: first to demonstrate the facility capabilities for performing small propeller aeroacoustic testing, and second to compare experimental measurements with computational fluid dynamic (CFD) predictions and CFD-based acoustic predictions of the tested propeller configurations for tool development and validation purposes.

Zawodny, Nikolas S.

Aerodynamic performance of a 1.35-pressure-ratio axial-flow fan stage

The overall blade element performances and the aerodynamic design parameters are presented for a 1.35-pressure-ratio fan stage. The fan stage was designed for a weight flow of 32.7 kilograms per second and a tip speed of 302.8 meters per second. At design speed the stage peak efficiency of 0.879 occurred at a pressure ratio of 1.329 and design flow. Stage stall margin was approximately 14 percent. At design flow rotor efficiency was 0.94 and the pressure ratio was 1.360.

Osborn, W. M.

Off-design computer code for calculating the aerodynamic performance of axial-flow fans and compressors

An off-design axial-flow compressor code is presented and is available from COSMIC for predicting the aerodynamic performance maps of fans and compressors. Steady axisymmetric flow is assumed and the aerodynamic solution reduces to solving the two-dimensional flow field in the meridional plane. A streamline curvature method is used for calculating this flow-field outside the blade rows. This code allows for bleed flows and the first five stators can be reset for each rotational speed, capabilities which are necessary for large multistage compressors. The accuracy of the off-design performance predictions depend upon the validity of the flow loss and deviation correlation models. These empirical correlations for the flow loss and deviation are used to model the real flow effects and the off-design code will compute through small reverse flow regions. The input to this off-design code is fully described and a user's example case for a two-stage fan is included with complete input and output data sets. Also, a comparison of the off-design code predictions with experimental data is included which generally shows good agreement.

Schmidt, James F.

The Effect of Bypass Nozzle Exit Area on Fan Aerodynamic Performance and Noise in a Model Turbofan Simulator

The design of effective new technologies to reduce aircraft propulsion noise is dependent on identifying and understanding the noise sources and noise generation mechanisms in the modern turbofan engine, as well as determining their contribution to the overall aircraft noise signature. Therefore, a comprehensive aeroacoustic wind tunnel test program was conducted called the Fan Broadband Source Diagnostic Test as part of the NASA Quiet Aircraft Technology program. The test was performed in the anechoic NASA Glenn 9- by 15-Foot Low Speed Wind Tunnel using a 1/5 scale model turbofan simulator which represented a current generation, medium pressure ratio, high bypass turbofan aircraft engine. The investigation focused on simulating in model scale only the bypass section of the turbofan engine. The test objectives were to: identify the noise sources within the model and determine their noise level; investigate several component design technologies by determining their impact on the aerodynamic and acoustic performance of the fan stage; and conduct detailed flow diagnostics within the fan flow field to characterize the physics of the noise generation mechanisms in a turbofan model. This report discusses results obtained for one aspect of the Source Diagnostic Test that investigated the effect of the bypass or fan nozzle exit area on the bypass stage aerodynamic performance, specifically the fan and outlet guide vanes or stators, as well as the farfield acoustic noise level. The aerodynamic performance, farfield acoustics, and Laser Doppler Velocimeter flow diagnostic results are presented for the fan and four different fixed-area bypass nozzle configurations. The nozzles simulated fixed engine operating lines and encompassed the fan stage operating envelope from near stall to cruise. One nozzle was selected as a baseline reference, representing the nozzle area which would achieve the design point operating conditions and fan stage performance. The total area change from the smallest to the largest nozzle was 12.9 percent of the baseline nozzle area. The results will show that there are significant changes in aerodynamic performance and farfield acoustics as the fan nozzle area is increased. The weight flow through the fan model increased between 7 and 9 percent, the fan and stage pressure dropped between 8 and 10 percent, and the adiabatic efficiency increased between 2 and 3 percent--the magnitude of the change dependent on the fan speed. Results from force balance measurements of fan and outlet guide vane thrust will show that as the nozzle exit area is increased the combined thrust of the fan and outlet guide vanes together also increases, between 2 and 3.5 percent, mainly due to the increase in lift from the outlet guide vanes. In terms of farfield acoustics, the overall sound power level produced by the fan stage dropped nearly linearly between 1 dB at takeoff condition and 3.5 dB at approach condition, mainly due to a decrease in the broadband noise levels. Finally, fan swirl angle survey and Laser Doppler Velocimeter mean velocity and turbulence data obtained in the fan wake will show that the swirl angles and turbulence levels within the wake decrease as the fan nozzle area increases, which helps to explain the drop in the fan broadband noise at all fan speeds.

Hughes, Christopher E.

Aerodynamic performance of a fully film cooled core turbine vane tested with cold air in a two-dimensional cascade

The aerodynamic performance of a fully film cooled core turbine vane was investigated experimentally in a two-dimensional cascade of 10 vanes. Three of the 10 vanes were cooled; the others were solid (uncooled) vanes. Cold air was used for both the primary and coolant flows. The cascade test covered a range of pressure ratios corresponding to ideal exit critical velocity ratios of 0.6 to 0.95 and a range of coolant flow rates to 7.5 percent of the primary flow. The coolant flow was varied by changing the coolant supply pressure. The principal measurements were cross-channel surveys of exit total pressure, static pressure, and flow angle. The results presented include exit survey data and overall performance in terms of loss, flow angle, and weight flow for the range of exit velocity ratios and coolant flows investigated. The performance of the cooled vane is compared with the performance of an uncooled vane of the same profile and also with the performance obtained with a single cooled vane in the 10-vane cascade.

Stabe, R. G.

Aerodynamic performance of a ceramic-coated core turbine vane tested with cold air in a two-dimensional cascade

The aerodynamic performance of a core turbine vane with a ceramic coating was investigated experimentally in a two-dimensional cascade of 10 vanes. The vane was first tested with a rough coating and then retested after the coating had been smoothed. The test fluid was atmospheric air. The cascade tests covered a range of pressure ratios corresponding to ideal exit critical velocity ratios of 0.6 to 0.95. The principal measurements were cross-channel surveys of exit total pressure, static pressure, and flow angle. The results presented include exit survey results and overall performance in terms of flow angle, weight flow, and kinetic energy loss. The performance of the ceramic-coated vanes is compared with the performance of an uncoated vane having a similar profile.

Stabe, R. G.

Cold-air annular-cascade investigation of aerodynamic performance of core-engine-cooled turbine vanes. 2: Pressure surface trailing edge ejection and split trailing edge ejection

The aerodynamic performance of two trailing edge ejection cooling configurations of a core-engine stator vane were experimentally determined in an ambient inlet-air full-annular cascade where three-dimensional effects could be obtained. The tests were conducted at the design mean-radius ideal aftermixed critical velocity ratio of 0.778. Overall vane aftermixed thermodynamic and primary efficiencies were obtained over a range of coolant flows to about 10 percent of the primary flow at a primary to coolant total temperature ratio of 1.0. The radial variation in efficiency and the circumferential and radial variations in vane-exit total pressure were determined. Comparisons are made with the solid (uncooled) vane.

Mclallin, K. L.

Measured aerodynamic performance of a swept wing with a simulated ice accretion

The effect of a simulated glaze ice accretion on the aerodynamic performance of a three-dimensional swept wing is studied experimentally. A semispan wing of effective aspect ratio four was mounted from a splitter plate in the OSU subsonic wind tunnel. The model uses a NACA 0012 airfoil section on a rectangular planform with interchangeable tip and root pieces to allow for 0- and 30-degree sweep. Surface pressures were measured at 5 semispan locations on the swept-wing model. The section lift data for the 5 semispan locations are presented and compared with theory and zero-sweep model results. In addition, previously unpublished roughness data from the zero-sweep model is presented here. These data show a large drag and maximum lift penalty due to rough simulated glaze ice. The effect of wing-sweep is seen through a decrease in wing lift performance for both the clean and iced wing.

Khodadoust, A.

Experimental investigation of aerodynamic performance of cooled turbine vanes at gas- to collant-temperature ratios up to 2.75

The results of an experimental investigation of the aerodynamic performance of two geometrically similar turbine vanes with different cooling designs are presented. The test vanes were a convection-film-cooled vanes and a transpiration-cooled vane. A solid uncooled vane with the same aerodynamic profile as the cooled vane was also tested. Four vanes of each type were tested in an annular sector cascade. The cooled vanes were tested at primary to coolant temperature ratios of 1.0, 1.75, and 2.75 and a coolant to primary pressure ratios of 1.0, 1.2, and 1.5. This resulted in coolant flows up to about 10 percent of the primary flow. The principal measurements were surveys of vane exit total pressure, total temperature, and static pressure. The report includes a brief description of the test facility and the design of the test vanes. The test results presented include weight flow and efficiency data for the uncooled vanes and coolant flow, primary flow, and efficiency data as functions of the cooling variables for the cooled vanes.

Stabe, R. G.

Aerodynamic performance of scarf inlets

A scarf inlet is characterized by having a longer lower lip than upper lip leading to both aerodynamic and acoustic advantages. Aerodynamically, a scarf inlet has higher angle of attack capability and is less likely to ingest foreign objects while the aircraft is on the ground. Acoustically, a scarf inlet provides for reduced inlet radiated noise levels below the engine as a result of upward reflection and refraction of inlet radiated noise. Results of a wind tunnel test program are presented which illustrate the aerodynamic performance of two different scarf inlet designs. Based on these results, scarf inlet performance is summarized in a way to illustrate the advantages and limitations of a scarf inlet compared to an axisymmetric inlet.

Abbott, J. M.