Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Adiabatic Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The density temperature and the dry and wet virtual adiabats

A density temperature is introduced to represent virtual temperature and potential temperature on thermodynamic diagrams. This study reviews how the dry and wet virtual adiabats can be used to represent stability and air parcel density for unsaturated and cloudy air, and present formula and tabulations.

Bartlo, J.↗

The effect of cycle variables on the emissions and performance of lean premixed gas turbine primary zone combustor

Experiments were conducted in which a stream of premixed propane and air was burned under conditions representative of gas-turbine operation. Emissions of NOx, CO, and unburned hydrocarbons were measured over a range of combustor inlet temperature (600-1000 K), pressure (5-30 atm), and residence time (1-3 msec) at equivalence ratios from 0.7 down to the lean stability limit. At inlet temperatures of 800 and 1000 K, NOx emissions displayed little sensitivity to pressure. At an inlet temperature of 600 K, observed NOx levels dropped markedly with decreasing pressure for pressures below 20 atm. NOx levels were proportional to combustor residence time, and formation rate was principally a function of adiabatic flame temperature. For adiabatic flame temperatures of 2050 K and higher, CO reached chemical equilibrium within 2 msec. Unburned hydrocarbon species dropped to a negligible level within 2 msec regardless of inlet temperature, pressure, or equivalence ratio. For a combustor residence time of 2.5 msec, combustion inefficiency became less than 0.01% at an adiabatic flame temperature of 2050 K. The maximum combustion inefficiency observed was of the order of 1% and corresponded to conditions near the lean stability limit.

Roffe, G.↗

The Thermal Balance of the Venus Atmosphere

Observations of the Venus thermal structure colledted during the first three decades of the space age reveal high surface temperatures, near-adiabatic vertical temperature gradients throughout the lower atmosphere, and a reversed pol-to-equator mesospheric thermal structure, with polar temperatures that are higher than those over the equator.

polar mesosphere↗

Correlations of catalytic combustor performance parameters

Correlations for combustion efficiency percentage drop and the minimum required adiabatic reaction temperature necessary to meet emissions goals of 13.6 g CO/kg fuel and 1.64 g HC/kg fuel are presented. Combustion efficiency was found to be a function of the cell density, cell circumference, reactor length, reference velocity, and adiabatic reaction temperature. The percentage pressure drop at an adiabatic reaction temperature of 1450 K was found to be proportional to the reference velocity to the 1.5 power and to the reactor length. It is inversely proportional to the pressure, cell hydraulic diameter, and fractional open area. The minimum required adiabatic reaction temperature was found to increase with reference velocity and decrease with cell circumference, cell density and reactor length. A catalyst factor was introduced into the correlations to account for differences between catalysts. Combustion efficiency, the percentage pressure drop, and the minimum required adiabatic reaction temperature were found to be a function of the catalyst factor. The data was from a 12 cm-diameter test rig with noble metal reactors using propane fuel at an inlet temperature of 800 K.

Bulzan, D. L.↗

Performance of J-33-A-21 Turbojet-Engine Compressor I - Over-All Performance Characteristics at Equivalent Impeller Speeds from 6000 to 13,400 RPM

The NACA is investigating a series of J-33 turbojet-engine compressors to determine the over-all and component performances and to improve theories of flow through large centrifugal compressors, The production model J-33-A-21 was operated over a range of inlet temperatures from 80 to -40 F and inlet pressures from 14 to 5 inches mercury absolute for equivalent impeller speeds from 6000 to 13,400 rpm. At the equivalent design speed of 11,500 rpm, the compressor had a peak pressure ratio of 3.98 at an equivalent weight flow of 73.4 pounds per second and an adiabatic temperature-rise , efficiency of 0.701. When the compressor speed was reduced from the design speed to 6000 rpm, the adiabatic temperature-rise efficiency increased to 0.747. At the maximum equivalent speed investigated (13,400 rpm), a peak pressure ratio of 5.09 was obtained at an adiabatic temperature-rise efficiency of 0.617 and an equivalent weight flow of 66.O pounds per second. An increase in inlet pressure from 5.5 to 14 inches mercury absolute, with a consequent increase in Reynolds number index, improved the pressure ratio but had no apparent effect on the ratio of temperature rise through the compressor to inlet temperature. The variation of the peak adiabatic temperature-rise efficiency with inlet pressure is in the direction that would be expected from a Reynolds number effect. Decrease in the inlet temperature from 80 to -40 F, with a consequent increase in Reynolds number index, resulted in scatter of the pressure-ratio data and increased values of temperature ratio. The variation of the adiabatic temperature-rise efficiency with inlet temperature is probably the result of heat-transfer effects and scatter in the pressure ratio.

Beede, William L.↗

Jet array impingement flow distributions and heat transfer characteristics. Effects of initial crossflow and nonuniform array geometry

Two-dimensional arrays of circular air jets impinging on a heat transfer surface parallel to the jet orifice plate are considered. The jet flow, after impingement, is constrained to exit in a single direction along the channel formed by the jet orifice plate and the heat transfer surface. The configurations considered are intended to model those of interest in current and contemplated gas turbine airfoil midchord cooling applications. The effects of an initial crossflow which approaches the array through an upstream extension of the channel are considered. Flow distributions as well as heat transfer coefficients and adiabatic wall temperatures resolved to one streamwise hole spacing were measured as a function of the initial crossflow rate and temperature relative to the jet flow rate and temperature. Both Nusselt number profiles and dimensionless adiabatic wall temperature (effectiveness) profiles are presented and discussed. Special test results which show a significant reduction of jet orifice discharge coefficients owing to the effect of a confined crossflow are also presented, along with a flow distribution model which incorporates those effects. A nonuniform array flow distribution model is developed and validated.

Florschuetz, L. W.↗

The effect of catalyst length and downstream reactor distance on catalytic combustor performance

A study was made to determine the effects on catalytic combustor performance which resulted from independently varying the length of a catalytic reactor and the length available for gas-phase reactions downstream of the catalyst. Monolithic combustion catalysts from three manufacturers were tested in a combustion test rig with no. 2 diesel fuel. Catalytic reactor lengths of 2.5 and 5.4 cm, and downstream gas-phase reaction distances of 7.3, 12.4, 17.5, and 22.5 cm were evaluated. Measurements of carbon monoxide, unburned hydrocarbons, nitrogen oxides, and pressure drop were made. The catalytic-reactor pressure drop was less than 1 percent of the upstream total pressure for all test configurations and test conditions. Nitrogen oxides and unburned hydrocarbons emissions were less than 0.25 g NO2/kg fuel and 0.6 g HC/kg fuel, respectively. The minimum operating temperature (defined as the adiabatic combustion temperature required to obtain carbon monoxide emissions below a reference level of 13.6 g CO/kg fuel) ranged from 1230 K to 1500 K for the various conditions and configurations tested. The minimum operating temperature decreased with increasing total (catalytic-reactor-plus-downstream-gas-phase-reactor-zone) residence time but was independent of the relative times spent in each region when the catalytic-reactor residence time was greater than or equal to 1.4 ms.

Anderson, D.↗

Cryogenic wind tunnels: Problems of continuous operation at low temperatures

The design of a cryogenic wind tunnel which operates continuously, and is capable of attaining transonic speeds at generating pressures of about 3 bars is described. Its stainless steel construction with inside insulation allows for very rapid temperature variations promoted by rapid changes in the liquid nitrogen flow. A comparative study of temperature measuring probes shows a good reliability of thin sheet thermocouples. To measure fluctuations, only a cold wire makes it possible to record frequencies of about 300 Hz. The use of an integral computer method makes it possible to determine the impact of the wall temperature ratio to the adiabatic wall temperature for the various parameters characterizing the boundary layer. These cases are processed with positive and negative pressure gradients.

Faulmann, D.↗

LES-Based Analysis of Film Cooling in a High-Pressure Turbine Rotor Including Effects of Purge and Tip Flow

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Secondary Flows↗

A GPU-based Approach for Turbomachinery Application

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Gas Turbine↗

A Compact, Continuous Adiabatic Demagnetization Refrigerator with High Heat Sink Temperature

In the continuous adiabatic demagnetization refrigerator (ADR), the existence of a constant temperature stage attached to the load breaks the link between the requirements of the load (usually a detector array) and the operation of the ADR. This allows the ADR to be cycled much faster, which yields more than an order of magnitude improvement in cooling power density over single-shot ADRs. Recent effort has focused on developing compact, efficient higher temperature stages. An important part of this work has been the development of passive gas-gap heat switches that transition (from conductive to insulating) at temperatures around 1 K and 4 K without the use of an actively heated getter. We have found that by carefully adjusting available surface area and the number of He-3 monolayers, gas-gap switches can be made to operate passively. Passive operation greatly reduces switching time and eliminates an important parasitic heat load. The current four stage ADR provides 6 micro W of cooling at 50 mK (21 micro W at 100 mK) and weighs less than 8 kg. It operates from a 4.2 K heat sink, which can be provided by an unpumped He bath or many commercially available mechanical cryocoolers. Reduction in critical current with temperature in our fourth stage NbTi magnet presently limits the maximum temperature of our system to approx. 5 K. We are developing compact, low-current Nb3Sn magnets that will raise the maximum heat sink temperature to over 10 K.

Shirron, P. J.↗

Qualitative Assessment of the Acoustic Disturbance Environment in the NASA LaRC 20-Inch MACH 6 Wind Tunnel

An experimental investigation was conducted on a 5-degree-half-angle cone with a flare in a conventional Mach 6 wind tunnel to examine the effect of facility noise on boundary layer transition. The effect of tunnel noise was inferred by comparing transition onset locations determined from the present test to that previously obtained in a Mach 6 quiet tunnel. Together, the two sets of experiments are believed to represent the first direct comparison of transition onset between a conventional and a quiet hypersonic wind tunnel using a common test model. In the present conventional hypersonic tunnel experiment, adiabatic wall temperatures were measured and heat transfer distributions were inferred on the cone flare model at zero degree angle of attack over a range of length Reynolds numbers (2 x 10(exp 6) to 10 x 10(exp 6)) which resulted in laminar and turbulent flow. Wall-to-total temperature ratio for the transient heating measurements and the adiabatic wall temperature measurements were 0.69 and 0.86, respectively. The cone flare nosetip radius was varied from 0.0001 to 0.125-inch to examine the effects of bluntness on transition onset. At comparable freestream conditions the transition onset Reynolds number obtained on the cone flare model in the conventional "noisy" tunnel was approximately 25% lower than that measured in the low disturbance tunnel.

Horvath, Thomas J.↗

Boundary Layer Transition on Slender Cones in Conventional and Low Disturbance Mach 6 Wind Tunnels

An experimental investigation was conducted on a 5-degree half-angle cone and a 5-degree half-angle flared cone in a conventional Mach 6 wind tunnel to examine the effects of facility noise on boundary layer transition. The influence of tunnel noise was inferred by comparing transition onset locations determined from the present test to that previously obtained in a Mach 6 low disturbance quiet tunnel. Together, the two sets of experiments are believed to represent the first direct comparison of transition onset between a conventional and a low disturbance wind tunnel using a common test model and transition detection technique. In the present conventional hypersonic tunnel experiment, separate measurements of heat transfer and adiabatic wall temperatures were obtained on the conical models at small angles of attack over a range of Reynolds numbers, which resulted in laminar, transitional, and turbulent flow. Smooth model turbulent heating distributions are compared to that obtained with transition forced via discrete surface roughness. The model nosetip radius was varied to examine the effects of bluntness on transition onset. Despite wall to total temperature differences between the transient heating measurements and the adiabatic wall temperature measurement, the two methods for determining sharp cone transition onset generally yielded equivalent locations. In the 'noisy' mode of the hypersonic low disturbance tunnel, transition onset occurred earlier than that measured in the conventional hypersonic tunnel, suggesting higher levels of freestream acoustic radiation relative to the conventional tunnel. At comparable freestream conditions, the transition onset Reynolds number under low disturbance conditions was a factor of 1.3 greater than that measured on flared cone in the LaRC conventional hypersonic tunnel and a factor of 1.6 greater that the flared cone run in the low disturbance tunnel run 'noisy'. Navier-Stokes mean flow computations and linear stability analysis were conducted to assess the experimental results and have indicated N factors associated with sharp flared cone transition onset to be approximately a factor of 2 lower than that inferred from the corresponding low disturbance tunnel measurements.

Horvath, Thomas J.↗

Optimization of a 10–Step Reduced CH₄/O₂ Combustion Mechanism for RDRE Applications

A 10-step, 9-species reduced mechanism for methane/oxygen combustion is evaluated and optimized for use in rotating detonation rocket engine (RDRE) simulations at an operating pressure of 10 bar. The mechanism is assessed against GRI-Mech 3.0 for ignition delay times, adiabatic equilibrium temperature and species, Chapman-Jouguet (CJ) detonation parameters, and laminar flame speed. A sequential Nelder–Mead optimization procedure is applied to the rate constants of reactions R1, R4, and R5, targeting ignition delay agreement over the equivalence ratio range φ = 1.0–1.4 and temperature range T = 1400–2000 K. The optimized mechanism achieves ignition delay agreement within 28% of GRI-Mech 3.0 for the temperature range relevant to RDRE operation (τ ≥ 5 μs). Adiabatic equilibrium temperatures and CJ detonation parameters are reproduced within 0.15% of GRI-Mech 3.0 values, confirming thermodynamic consistency of the mechanism. Laminar flame speed predictions deviate significantly from GRI-Mech 3.0, which is attributed to the absence of HO₂ chemistry in the reduced mechanism; this limitation does not affect RDRE simulation fidelity since laminar flame propagation is of secondary importance in RDREs.

Computational Fluid Dynamics↗

Unsteady Analysis of Blade and Tip Heat Transfer as Influenced by the Upstream Momentum and Thermal Wakes

The effect of the upstream wake on the blade heat transfer has been numerically examined. The geometry and the flow conditions of the first stage turbine blade of GE s E3 engine with a tip clearance equal to 2 percent of the span was utilized. Based on numerical calculations of the vane, a set of wake boundary conditions were approximated, which were subsequently imposed upon the downstream blade. This set consisted of the momentum and thermal wakes as well as the variation in modeled turbulence quantities of turbulence intensity and the length scale. Using a one-blade periodic domain, the distributions of unsteady heat transfer rate on the turbine blade and its tip, as affected by the wake, were determined. Such heat transfer coefficient distribution was computed using the wall heat flux and the adiabatic wall temperature to desensitize the heat transfer coefficient to the wall temperature. For the determination of the wall heat flux and the adiabatic wall temperatures, two sets of computations were required. The results were used in a phase-locked manner to compute the unsteady or steady heat transfer coefficients. It has been found that the unsteady wake has some effect on the distribution of the time averaged heat transfer coefficient on the blade and that this distribution is different from the distribution that is obtainable from a steady computation. This difference was found to be as large as 20 percent of the average heat transfer on the blade surface. On the tip surface, this difference is comparatively smaller and can be as large as four percent of the average.

Ameri, Ali A.↗

Emissions and Flame Structure Assessment of Aeroengine Micromixing Injectors for Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blends

Abstract The present study focuses on whether adapting low emissions liquid fuel injection concepts can be applied to gaseous mixtures. The goal is to develop an injector with specific geometric characteristics that will achieve the lowest emissions. This is conducted by evaluating emissions and flame diagnostics on a set of test hardware that has been developed for combustion of pure hydrogen and hydrogen/methane mixtures. The current test hardware adapts lean direct injection concepts from aeroengine injectors to a ground-based engine based on target flows associated with a Solar Turbines Industrial Engine gas turbine. A statistical test plan was developed to assess these geometric characteristics using a three level Box Behnken design. The test plan investigates the effect of injector flow splits, air swirl, fuel swirl, pressure drop, preheat temperature, fuel composition, and the adiabatic flame temperature on the flame structure and emissions performance. A total of 16 injectors were considered for a total of 688 test points for emission and imaging data. Emissions data were reported on a mass basis in ng/J and chemical reactor network analysis were conducted to further interpret emissions behavior. Images were also captured to analyze the flame structure features of interest including reaction volume, flame length, flame spread, and flame width. With these results, a predictive model for emissions was made to conclude the most optimal injector configuration is to have the highest level of air split (more volume of air through the injector plate versus the injector) and air swirl angle for both methane and hydrogen gas mixtures. The predictive emissions level for all of these cases were below 10 ng/J.

08 HYDROGEN↗

Effects of preferential diffusion on the burning intensity of curved flames

Using the Bunsen flame as a model curved flame, the coupled influence of preferential diffusion and flame stretch on the burning intensity of lean and rich mixtures of methane, propane, butane, ethylene, and hydrogen with air has been experimentally studied. The results substantiate theoretical predictions and quantify previous experimental observations that, for mixtures whose effective Lewis numbers (Le) are less than unity, the flame temperature is less than the adiabatic flame temperature. This temperature also decreases towards the flame tip, which has the largest curvature and therefore may locally extinguish. The dominance of diffusional transport in influencing the intensity of curved flames is demonstrated by showing that the tip opening of the highly diffusive hydrogen/air flames occurs at constant hydrogen equivalence ratios of about 1.15 to 1.20, being almost independent of the flow intensity and uniformity.

Mizomoto, M.↗