Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Adhesion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Importance of corners in fracture of highly crosslinked polymeric adhesives

In this study, very large molecular dynamics simulations with open ends between two solid adherends have been performed treating tensile deformation of coarse-grained, highly crosslinked polymer networks modeling epoxy systems. The open boundary and the presence of corners dramatically alter the fracture behavior. In contrast to systems with periodic boundaries, the failure strain decreases with increasing system size until a critical size is reached. This decrease greatly reduces the difference in the crack initiation strains between simulation and experiment. In the open geometry, the sides of the polymer network contract inward forming wedge shaped corners. The stress and strain are concentrated in the corners where the shear component is present and large. The nonuniformity of the strain results in accumulation of bond breaking in the corners and crack initiation there. Lastly, t the corner strain is system size dependent, which results in a system size dependence of the failure strain.

36 MATERIALS SCIENCE↗

Urethane/Silicone Adhesives for Bonding Flexing Metal Parts

Adhesives that are blends of commercially available urethane and silicone adhesives have been found to be useful for bonding metal parts that flex somewhat during use. These urethane/silicone adhesives are formulated for the specific metal parts to be bonded. The bonds formed by these adhesives have peel and shear strengths greater than those of bonds formed by double-sided tapes and by other adhesives, including epoxies and neat silicones. In addition, unlike the bonds formed by epoxies, the bonds formed by these adhesives retain flexibility. In the initial application for which the urethane/silicone adhesives were devised, there was a need to bond spring rings, which provide longitudinal rigidity for inflatable satellite booms, with the blades that provide the booms axial strength. The problem was to make the bonds withstand the stresses, associated with differences in curvature between the bonded parts, that arose when the booms were deflated and the springs were compressed. In experiments using single adhesives (that is, not the urethane/ silicone blends), the bonds were broken and, in each experiment, it was found that the adhesive bonded well with either the ring or with the blade, but not both. After numerous experiments, the adhesive that bonded best with the rings and the adhesive that bonded best with the blades were identified. These adhesives were then blended and, as expected, the blend bonded well with both the rings and the blades. The two adhesives are Kalex (or equivalent) high-shear-strength urethane and Dow Corning 732 (or equivalent) silicone. The nominal mixture ratio is 5 volume parts of the urethane per 1 volume part of the silicone. Increasing the proportion of silicone makes the bond weaker but more flexible, and decreasing the proportion of silicone makes the bond stronger but more brittle. The urethane/silicone blend must be prepared and used quickly because of the limited working time of the urethane: The precursor of the urethane adhesive is supplied in a two-part form, comprising a resin and a hardener that must be mixed. The resulting urethane adhesive has a working time of 3 to 5 minutes. To prepare the urethane/silicone blend, one must quickly add the silicone to the urethane adhesive and mix it in thoroughly within the working time of the urethane. Once the urethane/silicone blend has been mixed and applied to the bond surfaces, it takes about 2 hours for the adhesive to cure under pressure. However, it takes about 24 hours for the adhesive to reach full strength.

Edwards, Paul D.↗

Thermal Characterization of Adhesive

The current Space Shuttle Reusable Solid Rocket Motor (RSRM) nozzle adhesive bond system is being replaced due to obsolescence. Down-selection and performance testing of the structural adhesives resulted in the selection of two candidate replacement adhesives, Resin Technology Group's Tiga 321 and 3M's EC2615XLW. This paper describes rocket motor testing of these two adhesives. Four forty-pound charge motors were fabricated in configurations that would allow side by side comparison testing of the candidate replacement adhesives and the current RSRM adhesives. The motors provided an environment where the thermal performance of adhesives in flame surface bondlines was compared. Results of the FPC testing show that: 1) The phenolic char depths on radial bond lines is approximately the same and vary depending on the position in the blast tube regardless of which adhesive was used; 2) The adhesive char depth of the candidate replacement adhesives is less than the char depth of the current adhesives; 3) The heat-affected depth of the candidate replacement adhesives is less than the heat-affected depth of the current adhesives; and 4) The ablation rates for both replacement adhesives are slower than that of the current adhesives.

Spomer, Ken A.↗

Thermal Characterization of Epoxy Adhesive by Hotfire Testing

This paper describes subscale solid-rocket motor hot-fire testing of epoxy adhesives in flame surface bondlines to evaluate heat-affected depth, char depth and ablation rate. Hot-fire testing is part of an adhesive down-selection program on the Space Shuttle Solid Rocket Motor Nozzle to provide additional confidence in the down-selected adhesives. The current nozzle structural adhesive bond system is being replaced due to obsolescence. Prior to hot-fire testing, adhesives were tested for chemical, physical and mechanical properties, which resulted in the selection of two potential replacement adhesives, Resin Technology Group's TIGA 321 and 3M's EC2615XLW. Hot-fire testing consisted of four forty-pound charge (FPC) motors fabricated in configurations that would allow side-by-side comparison testing of the candidate replacement adhesives with the current RSRM adhesives. Results of the FPC motor testing show that: 1) the phenolic char depths on radial bondlines is approximately the same and vary depending on the position in the blast tube regardless of which adhesive was used, 2) the replacement candidate adhesive char depths are equivalent to the char depths of the current adhesives, 3) the heat-affected depths of the candidate and current adhesives are equivalent, and 4) the ablation rates for both replacement adhesives were equivalent to the current adhesives.

Spomer, Ken A.↗

Glass-particle adhesion-force-distribution on clean (laboratory) and contaminated (outdoor) surfaces

This article explores whether laboratory-clean samples are representative of real outdoor surfaces – often covered in dust and other contaminants – with respect to adhesion properties, which ultimately affect particle resuspension. In this study, Atomic Force Microscopy (AFM) was used to measure the adhesion force between a clean, smooth glass particle (5 µm in diameter) and two glass slides, one prepared according to common laboratory practices (hereafter, clean glass) and a second one left outdoors for six weeks (hereafter, contaminated glass). It was found that the adhesion force distribution was bimodal for the clean glass while it showed three peaks for the contaminated glass. For both surfaces, the adhesion force showed a peak at very low adhesion values (< 100 nN) representing 1.2% of the measurements for the clean glass and 58% for the contaminated glass. This low-adhesion peak is important because it represents the particles that would be resuspended first even in light winds. The low adhesion-force measurements were associated with the presence of contaminants on the surface. Another notable difference between the adhesion force distributions was a long tail at high adhesion forces for clean glass (up to ~1900 nN) and the absence of the tail for the contaminated glass, which had a maximum adhesion force of 950 nN. The mean adhesion force on the contaminated glass was also lower than on the clean glass (206 ± 240 nN vs. 516 ± 354 nN). These observations indicate that the adhesion force distribution between a 5-µm smooth and clean glass sphere and the outdoor contaminated glass surface is quite different from that of the clean glass surface. Hence, one should be cautious when using adhesion force measurements from clean surfaces to estimate particle resuspension from outdoor surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗