Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Active Thermal Control Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,047 records · Page 4

Hydrofluoroether (HFE) Cleaning Fluid Replacement and Qualification

This NASA Engineering and Safety Center (NESC) Technical Assessment Report addresses the urgent need to identify, test, and qualify replacement cleaning solvents and technologies following 3M’s decision to discontinue production of hydrofluoroether (HFE) products, including Novec HFE-7100, by the end of 2025. HFE-7100 is widely used across NASA for precision cleaning of ground and flight hardware, especially in oxygen system components, and as a heat transfer fluid in high-power-density thermal control systems. The assessment evaluates commercially available replacement solvents, alternative cleaning technologies, and their compatibility with NASA’s operational requirements. Key findings include the identification of viable solvent replacements, their performance in contaminant removal, materials compatibility, and oxygen system safety. The report also explores novel cleaning approaches, including aqueous, supercritical CO₂, cryogenic aerosol, plasma, UV-ozone, magnetically optimized fluids, and induced charge active filtration, highlighting their merits, limitations, and readiness for NASA adoption. The NESC provides recommendations for solvent selection, facility adaptation, and continued technology maturation to ensure mission continuity and regulatory compliance.

Alternative Cleaning Technologies

Harness Thermal Heat Loss Measurement for a Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY

Evaluation of Long-Term Storage Stability and Operational Efficiency of Rapid Cycle Amine Adsorbents

With the recent incorporation of Mars Extravehicular Activity (EVA) into the 2025 NASA roadmap, Rapid Cycle Amine (RCA) technology advancement within the Exploration Extravehicular Mobility Unit (xEMU) applies to both the upcoming Lunar Artemis missions and future human exploration of Mars. The incorporation of commercial spacesuit vendors to service NASA’s crewed-space programs since 2021 has increased the demand for regenerable, RCA-based carbon dioxide (CO2) and humidity control adsorbents. The regenerable RCA subunit is the most advanced, long-term solution for CO2 removal and humidity control, enabling both lunar and Martian EVAs. The adsorbent selected for use within the RCA unit must exhibit sufficient storage stability and operational efficiency for prolonged missions. As XploSafe worked to simultaneously develop both a recirculating sub-atmospheric test rig and adsorbents for the RCA system within the xEMU, several novel adsorbents were evaluated for long-term storage stability in support of future extended-duration missions. The chosen materials were periodically evaluated by nuclear magnetic resonance (NMR) spectroscopy, thermal desorption-coupled with gas chromatography/mass spectrometry (TD-GC/MS), and CO2 adsorption to assess long-term storage efficacy across various environmental storage conditions. NMR spectroscopy was utilized by extracting the active CO2 adsorbing chemical from the solid support with deuterated solvent and comparing the spectra over time for degradation and change. The solid adsorbents were also analyzed via TD-GC/MS to reveal any potential off-gassing chemicals over time. Additionally, XploSafe’s breakthrough test rig was utilized to dose the solid adsorbents with a 585 BTU/h metabolic rate flow-equivalent CO2 stream and monitored for 0–99% CO2 breakthrough. The performance metrics from the breakthrough analysis were compared over the storage study duration for CO2 removal and humidity control. Xplo-SA9T was evaluated for 24 months, whereas two additional adsorbent variants, MMPA-Sorbent and LPEI-Sorbent, were each evaluated for 12 months.

John R Tidwell

Advanced Space Power PEM Fuel Cell Systems

A model showing mass and heat transfer in proton exchange membrane (PEM) single cells is presented. For space applications, stack operation requiring combined water and thermal management is needed. Advanced hardware designs able to combine these two techniques are available. Test results are shown for membrane materials which can operate with sufficiently fast diffusive water transport to sustain current densities of 300 ma per square centimeter. Higher power density levels are predicted to require active water removal.

PEM

Controls for Electrified Aircraft Propulsion

Advanced electrified aircraft propulsion (EAP) concepts with integrated power, propulsion, and thermal systems require the development of equally sophisticated controllers to fly safe and efficient missions. Hybrid electric aircraft utilize electric machines mechanically coupled to the engine shafts to extract and insert power for a variety of purposes. Additionally, electric machines may drive propulsive fans pulling from a combination of on-board energy storage devices and engine extracted power. NASA’s investment in hybrid electric aircraft hardware-in-the-loop testing enables controls research on representative engine models using a novel emulation and scaling methodology. High-voltage, high-power electrical powertrain presents several technical risks at altitude. High-power requires high efficiency to minimize losses. Superconducting electric machines and power distribution research at NASA has identified key challenges with potential controls solutions. These risks necessitate the development of controllers robust to model uncertainty, disturbances, and fault conditions. System health management and fault detection schemes play an important role in a multi-layer controls approach that utilizes a supervisor which oversees inner loops for the highly coupled power, propulsion, and thermal systems. Such a supervisory controller enables coordinates energy transfer between engines, energy storage devices, electric machines, propulsors, and heat exchangers. Existing methods have shown an improvement in engine operability using the hybrid electric powertrain.

Halle E Buescher

Nuclear Safety [Vol. 33, No. 1, January-March 1992]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 Technical Note: A New Approach to Fission Reactor Safety, Yu. V. Petrov; 5 Erratum; ACCIDENT ANALYSIS: 6 Analysis and Modeling of Fission Product Release from Various Uranium-Aluminum Plate-Type Reactor Fuels, R. P. Taleyarkhan; CONTROL AND INSTRUMENTATION: 23 Applications of a Surveillance and Diagnostics Methodology Using Neutron Noise From a Pressurized-Water Reactor, R. T. Wood, L. F. Miller, and R. B. Perez; DESIGN FEATURES: 36 Westinghouse Advanced Passive 600 Plant, B. A. McIntyre and R. K. Beck; 47 System 80+™ PWR Safety Design, C. W. Bagnal, R. A. Matzie, and R. S. Turk; ENVIRONMENTAL EFFECTS: 58 The MATS Experiments—Mesoscale Atmospheric Transport Studies at the Savannah River Site, A. H. Weber, S. Berman, R. J. Kurzeja, and R. P. Addis; 75 Book Review: Environmental Radioactivity in the European Community 1984-1985-1986, C. A. Little; WASTE AND SPENT FUEL MANAGEMENT: 76 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver; OPERATING EXPERIENCES: 87 Aging Assessment of BWR Control Rod Drive Systems, R. H. Greene; 100 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 103 Selected Safety-Related Events, Compiled by G. A. Murphy; 110 Operating U.S. Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver; RECENT DEVELOPMENTS: 129 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 139 Reports, Standards, and Safety Guides, D. S. Queener; 143 Proposed Rule Changes as of Sept. 30 1991; ANNOUNCEMENTS: 128 Harvard School of Public Health Announces Short Courses; 128 16th Biennial ANS Topical Meeting on Reactor Operating Experience: Present and Future Technologies—Applying Lessons Learned (Call for Papers); 147 The Authors; 150 Indexes to Nuclear Safety, Volume 32; 154 Errata.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Thermal Disorder‐Induced Strain and Carrier Localization Activate Reverse Halide Segregation

The reversal of halide ions is studied under various conditions. However, the underlying mechanism of heat-induced reversal remains unclear. This work finds that dynamic disorder-induced localization of self-trapped polarons and thermal disorder-induced strain (TDIS) can be co-acting drivers of reverse segregation. Localization of polarons results in an order of magnitude decrease in excess carrier density (polaron population), causing a reduced impact of the light-induced strain (LIS – responsible for segregation) on the perovskite framework. Meanwhile, exposing the lattice to TDIS exceeding the LIS can eliminate the photoexcitation-induced strain gradient, as thermal fluctuations of the lattice can mask the LIS strain. Under continuous 0.1 W cm -2 illumination (upon segregation), the strain disorder is estimated to be 0.14%, while at 80 °C under dark conditions, the strain is 0.23%. However, in situ heating of the segregated film to 80 °C under continuous illumination (upon reversal) increases the total strain disorder to 0.25%, where TDIS is likely to have a dominant contribution. Therefore, the contribution of entropy to the system's free energy is likely to dominate, respectively. Various temperature-dependent in situ measurements and simulations further support the results. These findings highlight the importance of strain homogenization for designing stable perovskites under real-world operating conditions.

36 MATERIALS SCIENCE

Thermal Vacuum Testing of the Cryostat Heat Removal System for COSI SMEX

The Cryostat Heat Removal System (CHRS) of the Compton Spectrometer and Imager (COSI) consists of cryocooler, three transport aluminum ammonia Constant Conductance Heat Pipes (CCHP), three radiators with CCHP spreaders and Cryocooler Control Electronics (CCE) attached to a separate radiator. A Thermal Vacuum (TVAC) test was conducted at NASA Goddard Space Flight Center to characterize the integrated COSI CHRS in the flat configuration. This presentation summarizes the measured COSI CHRS performance along with lessons learned.

Pipes

Enhanced Catalytic Dechlorination of Polyvinyl Chloride (PVC) and H2 Production Enabled by Synergistic Gaδ+/Ga0 Active Sites in Liquid Metal Particles

Polyvinyl chloride (PVC) is ubiquitous yet challenging to recycle due to its tendency to thermally decompose above 250 °C, releasing toxic, corrosive chlorinated compounds, and its inability to melt. Here, we report a catalytic strategy for PVC upcycling at 160 °C using gallium liquid metal particles (Ga-LMP) featuring a dynamic Ga-GaOOH core–shell architecture. These catalysts enable concurrent dechlorination and hydrogen evolution, yielding up to 7% H2 (based on initial hydrogen atoms in PVC) along with a highly dechlorinated (>95%) carbonaceous solid and aqueous HCl. Mechanistic investigations combining X-ray photoelectron spectroscopy, infrared spectroscopy, solid-state NMR, inelastic neutron scattering, and ab initio molecular dynamics reveal a synergistic interplay between Gaδ+ sites in the GaOOH shell and metallic Ga0 in the core. Cationic Ga initiates C–Cl bond activation and HCl formation, while progressive reduction of the shell exposes Ga0 sites that promote C–H activation and H2 evolution. Control experiments with a Ga salt and bulk Ga liquid metal confirmed that neither oxidation state alone can achieve both transformations efficiently. This work establishes a dynamic dual-site paradigm for liquid metal catalysis, in which the in situ evolution and coexistence of oxidized and metallic species enable sequential and cooperative bond activation pathways. These findings provide a general design principle for novel liquid metal catalysts that target challenging polymer transformations under mild conditions.

Zingg, Benjamin [ORNL] (ORCID:0009000914530153)

Solar Absorptance and Thermal Emittance of Some Common Spacecraft Thermal-Control Coatings

Solar absorptance and thermal emittance of spacecraft materials are critical parameters in determining spacecraft temperature control. Because thickness, surface preparation, coatings formulation, manufacturing techniques, etc. affect these parameters, it is usually necessary to measure the absorptance and emittance of materials before they are used. Absorptance and emittance data for many common types of thermal control coatings, are together with some sample spectral data curves of absorptance. In some cases for which ultraviolet and particle radiation data are available, the degraded absorptance and emittance values are also listed.

John H Henninger

Transit Thermal Control Design for Galileo Entry Probe for Planet Jupiter

A totally passive design was completed for the thermal control of the Galileo entry probe during its transit to the planet Jupiter. The design utilizes radio isotope heater units, multilayer insulation blankets and a thermal radiator in conjunction with a design conductance support structure to achieve both the required storage and critical initial planet atmosphere entry temperatures. The probe transit thermal design was completed and verified based on thermal vacuum testing of a prototype probe thermal test model.

George C. Haverly

Simulated Lunar Gravity Testing of VIPER Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) mission consists of a rover designed to explore the lunar south pole. One of the main challenges faced by the rover during the lunar polar exploration is the adverse thermal environment. Temperatures can fluctuate more than a 100°C between day and night; potentially dropping to −246°C in permanent shadow regions. To maintain the rover components within temperature limits, VIPER’s Thermal Management System (TMS) relies heavily on Loop Heat Pipes (LHPs). To assist the design of the thermal management system, an Engineering Design Unit (EDU) LHP has been tested in several opportunities under thermal vacuum (TVAC) environment. Of particular interest was the LHP performance in lunar gravity. To that end, the EDU LHP was tested at the nominal orientation within the rover assembly, vertical, and inclined such that the gravitational component acting on the LHP evaporator and condenser was 1/6g (lunar gravity is 1/6 of Earth gravity) when compared to the vertical configuration. This paper will examine the LHP conductance as one the key parameters to assess the effect of the gravity on the LHP performance.

Loop Heat Pipe

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer