Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Active Power Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Molten Chloride Thermophysical Properties, Chemical Optimization, and Purification

Next-generation concentrating solar power (CSP) technology requires high-temperature heat-transfer fluids and thermal energy storage that can operate in the temperature range of 500°–720°C. This high temperature demands a new chemistry for the heat-transfer fluids that must have high-temperature thermal and chemical stabilities, high energy density, and low corrosion rate on metallic materials used in the heat exchangers, piping, and thermal energy storage tanks. A ternary MgCl 2 -KCl-NaCl chloride-salt system has been proposed to achieve such goals, given its high-temperature thermal stability. The chloride-salt-based systems have been used by the metallurgy industry as the electrolyte to electrolytically extract metallic magnesium. They have also attracted attentions from the nuclear industry for developing the molten salt fast reactors that can operate at close to atmospheric pressure and at higher temperature than traditional light-water reactors. However, the corrosion properties of the ternary salt are not well known. The corrosion mechanism is believed to be correlated to the presence of MgOHCl impurity at the operation temperature. MgOHCl is fundamentally caused by the hygroscopic nature of the MgCl 2 component. Therefore, the first key objective of this project is to understand the nature of the corrosiveness of the ternary chloride-salt system and its prevention by designing new lab-scale purification processes. Because of its importance, a working group called the Chloride Salt Collective across multiple U.S. Department of Energy national laboratories is established to gain experimental agreement on the corrosion behaviors. In addition, water generation during salt dehydration could lead to highly corrosive HCl/water mixture via a hydrolysis process between water and anhydrous MgCl 2 or MgCl 2 hydrates. MgOHCl will eventually be converted to MgO particulates regardless of the chemical path chosen (i.e., by thermal decomposition, chemical purification with an active metal, or electrochemical purification utilizing the reduction power of electron flows). Large MgO particles with high hardness can wear out bearing and bushing and even clog the delicate channels in the primary heat exchanger. Because of this, a second objective is to understand the chemistry behind salt purification and transfer the scientific understanding to a set of engineering know-how for large-scale salt melter design. Because there is limited information on the thermophysical properties and the sensitivity of these properties around the targeted salt composition, a third objective is to measure thermophysical properties relevant to system and component design and support Topic 1 Liquid Pathway development. For example, composition shift due to salt reaction with water can be a potential issue because it can lead to changes of thermophysical properties, such as (1) melting point (or freeze point), which can jeopardize safe operation of the supercritical CO 2 power cycle proposed for next-generation CSP, and (2) heat capacity and density, which can decrease the overall power-generation capability of the plants. The value of the thermal conductivity of the selected salt composition is also a critical criterion for the solar receiver design.

14 SOLAR ENERGY↗

Orbital period variability in the eclipsing pulsar binary PSR B1957+20: Evidence for a tidally powered star

Recent observations indicate that the eclipsing pulsar binary PSR B1957+20 undergoes alternating epochs of orbital period increase and decrease. We apply a model developed to explain orbital period changes of alternating sign in other binaries to the PSR B1957+20 system and find that it fits the pulsars observations well. The novel feature of the PSR B1957+20 system is that the energy flow in the companion needed to power the orbital period change mechanism can be supplied by tidal dissipation, making the companion the first identified tidally powered star. The flow of energy in the companion drives magnetic activity, which underlies the observed orbital period variations. The magnetic activity and the wind driven by the pulsar irradiation results in a torque on the spin of the companion. This torque holds the companion out of synchronous rotation, causing tidal dissipation of energy. We propose that the progenitor had a approximately 2 hr orbital period and a companion mass of 0.1-0.2 solar mass, and the system is evolving to longer orbital periods by mass and angular momentum loss on a timescale of 10(exp 8) yr.

Applegate, James H.↗

The vestibulosympathetic reflex in humans: neural interactions between cardiovascular reflexes

1. Over the past 5 years, there has been emerging evidence that the vestibular system regulates sympathetic nerve activity in humans. We have studied this issue in humans by using head-down rotation (HDR) in the prone position. 2. These studies have clearly demonstrated increases in muscle sympathetic nerve activity (MSNA) and calf vascular resistance during HDR. These responses are mediated by engagement of the otolith organs and not the semicircular canals. 3. However, differential activation of sympathetic nerve activity has been observed during HDR. Unlike MSNA, skin sympathetic nerve activity does not increase with HDR. 4. Examination of the vestibulosympathetic reflex with other cardiovascular reflexes (i.e. barorereflexes and skeletal muscle reflexes) has shown an additive interaction for MSNA. 5. The additive interaction between the baroreflexes and vestibulosympathetic reflex suggests that the vestibular system may assist in defending against orthostatic challenges in humans by elevating MSNA beyond that of the baroreflexes. 6. In addition, the further increase in MSNA via otolith stimulation during isometric handgrip, when arterial pressure is elevated markedly, indicates that the vestibulosympathetic reflex is a powerful activator of MSNA and may contribute to blood pressure and flow regulation during dynamic exercise. 7. Future studies will help evaluate the importance of the vestibulosympathetic reflex in clinical conditions associated with orthostatic hypotension.

Review↗

Analysis of Lobe Power Calculator and Indication System with Physics and Cycle Based Models

The Advanced Test Reactor (ATR) at INL measures reactor power through two methods, thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine the thermal quadrant powers. The N-16 system utilizes a beta chamber detector that outputs reactivity levels to calculate lobe power through an algorithm called lobe power calculation and indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. This is crucial for maintaining safety limits. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have assisted system engineers at INL with the objective to reach a more dynamic system. In return the system demonstrates an increase in the accuracy of power reading while maintaining safety margins. The new proposed coefficient and multiple method implements a cycle specific, and a physics-based model intended for changing coefficients during operation. This calibration experiment focuses on power splitting, outer shim and neck shim, as well as fuel burning into the RDAS weighting factors. Results show that the Physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. This proved true for both constrained and unconstrained testing. This is most likely due to the physics data fitting approach that resulted in favorable coefficients and multipliers for 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Decentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration: Preprint

This paper introduces a fully decentralized control strategy that allows for individualized active and reactive power control of H-bridge inverters connected in series. After formulating a model of the system power flows, we outline a communications-free approach where each inverter can act on independent commands. Inverter-level feedback is accomplished locally via a measurement of current flowing through the stack. A key feature is the lack of any centralized control routines or phase-locked loop. In this framework, the reactive power control loops achieve voltage synchronization among the converters and the grid, and the active power control loops modulate the terminal voltage amplitudes that influence power delivery. Furthermore, pole placement via state feedback is used to ensure stability of voltage synchronization while also enabling tracking of bidirectional power commands. Simulations are presented to validate the proposed approach.

communication-free modular converter control↗

Rectified Rotational Dynamics of Mobile Inclusions in Two-Dimensional Active Nematics

We investigate the dynamics of mobile inclusions embedded in 2D active nematics. The interplay between the inclusion shape, boundary-induced nematic order, and autonomous flows powers the inclusion motion. Disks and achiral gears exhibit unbiased rotational motion, but with distinct dynamics. In comparison, chiral gear-shaped inclusions exhibit long-term rectified rotation, which is correlated with dynamics and polarization of nearby +1/2 topological defects. Furthermore, the chirality of defect polarities and the active nematic texture around the inclusion correlate with the inclusion’s instantaneous rotation rate. Inclusions provide a promising tool for probing the rheological properties of active nematics and extracting ordered motion from their inherently chaotic motion.

36 MATERIALS SCIENCE↗

Novel Active Combustion Control Valve

This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

Caspermeyer, Matt↗

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupled Reactor Multiphysics and Mass Scalability Assessment for Crewed Megawatt-Class NEP System Architectures

Nuclear Electric Propulsion (NEP) is an in-space propulsion technology capable of enabling opposition and conjunction class crewed Mars missions. NEP subsystems include the reactor for heat generation, a power conversion system (PCS), power management and distribution, electric propulsion system, and heat rejection system. Specific mass, or α (kg/kWe), is a key performance parameter (KPP) of the propulsion system which is directly scalable with the performance and mass predictions for each individual component. To inform technology maturation planning activities, full system and component level parametric modeling is ongoing to explore the design trade space and illustrate the effect of subsystem design choices on the system KPPs. In this study, scaling of high-assay, low-enriched uranium reactor designs is assessed through coupled reactor physics and thermal hydraulics analyses. Scaling analyses evaluate the impact of system performance parameters (power level, interface temperatures) on mass for direct gas cooled, pumped liquid metal, and passively-cooled heat pipe reactor concepts. Each concept requires specific geometries, fluids, and power conversion interface conditions (temperature, pressure, flow rate) to meet desired performance and mass. The reactor assembly includes the active core (fuel, moderator, cladding, working fluid), axial and radial neutron reflectors, control drums, structural support / pressure vessel, and external radiation shielding. Each of these components are parametrically sized based on performance parameters for a megawatt-class power cycle. Results of this scaling analysis increase NEP propulsion system modeling fidelity and ultimately aim to support concept down-selection along with related technology development planning. The reactor and shield α are a function of several PCS and heat rejection system design choices, and reactor scaling with these parameters must be considered to enable an informed decision on an optimal reactor geometry and working fluid combination.

Nuclear Electric Propulsion↗

Cyber Resilient Flexible Alternating Current Transmission Systems (XFACTS)

This report summarizes the activities conducted under the DOE-OE funded project DEOE0000897, Cyber Attack Resilient Flexible AC Systems – XFACTS. Hitachi Energy (HE), in collaboration with ABB Inc. (ABB), Bonneville Power Administration (BPA), University of Illinois at Urbana-Champaign (UIUC), Iowa State University (ISU), and University of Idaho (UI) pursued the development of a system of defense for Flexible Alternating current Transmission Systems against cyber-attacks (XFACTS). A FACTS substation enhanced with XFACTS defense mechanisms will be capable of mitigating cyberattacks especially those that seek to control electrical parameters like voltage or current and interrupt the power flow in AC lines. It empowers existing FACTS controllers and associated intelligent electronic devices to detect and mitigate malicious intents to depress system voltages, destabilize power flows, trip AC circuit breakers, corrupt currents, and voltages, even if the malicious commands and the measurements have correct syntax. The XFACTS functions utilize the physics of active power electronic systems, control and protection, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected FACTS substation devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strain-rate/temperature behavior of high density polyethylene in compression

The compressive strain rate/temperature behavior of highly linear, high density polyethylene was analyzed in terms of the predictive relations developed for metals and other crystalline materials. For strains of 5 percent and above, the relationship between applied strain rate, dotted epsilon, and resulting flow stress, sigma, was found to be: dotted epsilon exp times (Q sub f/RT) = k'(sigma/sigma sub c) to the nth power; the left-hand side is the activation-energy-compensated strain rate, where Q sub f is activation energy for flow, R is gas constant, and T is temperature; k is a constant, n is temperature-independent stress exponent, and sigma/sigma sub c is structure-compensated stress. A master curve resulted from a logarithmic plot of activation-energy-compensated strain rate versus structure-compensated stress.

Clements, L. L.↗

Thermo-Hydro-Mechanical Modeling of Brine Migration in a Heated Borehole Test in Bedded Salt

Abstract This research paper focuses on the thermo-hydro-mechanical (THM) modeling of brine migration in a heated borehole test conducted as part of the ongoing Brine Availability Test in Salt (BATS) at the Waste Isolation Pilot Plant (WIPP) in New Mexico. It is a component of the international collaboration project DECOVALEX-2023 (DEvelopment of COupled models and their VALidation against EXperiments), which aims to understand the THM processes governing brine flow in heated rock salt repositories through collaborative analysis by multiple research teams. Using the TOUGH–FLAC simulator, THM simulations were performed and compared with data from the BATS phase 1a. This experiment involved two identical horizontal-borehole arrays, one heated and one serving as a control, both equipped with sensor arrays. Analysis of measurements revealed water flow rate surges during heater power transitions, with the highest jump observed during cooling. Acoustic emission activity exhibited distinct patterns in response to heater power changes, suggesting that damage to rock salt is particularly pronounced during the cooling phase. The THM simulations successfully captured these phenomena, highlighting the significance of thermal effects, brine migration, and mechanical behavior in predicting brine availability in heated and damaged rock salt. Our modeling also revealed the critical interplay between heating and cooling-induced damage and its influence on flow properties, particularly affecting brine inflow estimation. Notably, we found that cooling-induced brine inflow spikes result from increased permeability due to tensile dilatancy. These findings have important implications for the development of robust containment strategies and enhance our understanding of the complex processes involved in repository performance.

58 GEOSCIENCES↗

MIDAS-DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution (MIDAS-DC2AC)

MIDAS DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

Tan, Jin↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

Assessment of the Use of Nanofluids in Spacecraft Active Thermal Control Systems

The addition of metallic nanoparticles to a base heat transfer fluid can dramatically increase its thermal conductivity. These nanofluids have been shown to have advantages in some heat transport systems. Their enhanced properties can allow lower system volumetric flow rates and can reduce the required pumping power. Nanofluids have been suggested for use as working fluids for spacecraft Active Thermal Control Systems (ATCSs). However, there are no studies showing the end-to-end effect of nanofluids on the design and performance of spacecraft ATCSs. In the present work, a parametric study is performed to assess the use of nanofluids in a spacecraft ATCSs. The design parameters of the current Orion capsule and the tabulated thermophysical properties of nanofluids are used to assess the possible benefits of nanofluids and how their incorporation affects the overall design of a spacecraft ATCS. The study shows that the unique system and component-level design parameters of spacecraft ATCSs render them best suited for pure working fluids. The addition of nanoparticles to typical spacecraft thermal control working fluids actually results in an increase in the system mass and required pumping power.

Ungar, Eugene K.↗

A low power flexible dielectric barrier discharge disinfects surfaces and improves the action of hydrogen peroxide

There is an urgent need for disinfection and sterilization devices accessible to the public that can be fulfilled by innovative strategies for using cold atmospheric pressure plasmas. Here, we demonstrate a successful novel combination of a flexible printed circuit design of a dielectric barrier discharge (flex-DBD) with an environmentally safe chemical reagent for surface decontamination from bacterial contaminants. Flex-DBD operates in ambient air, atmospheric pressure, and room temperature without any additional gas flow at a power density not exceeding 0.5 W/cm 2 . The flex-DBD activation of a 3% hydrogen peroxide solution results in the reduction in the bacterial load of a surface contaminant of > 6log 10 in 90 s, about 3log 10 and 2log 10 better than hydrogen peroxide alone or the flex-DBD alone, respectively, for the same treatment time. We propose that the synergy between plasma and hydrogen peroxide is based on the combined action of plasma-generated OH · radicals in the hydrogen peroxide solution and the reactive nitrogen species supplied by the plasma effluent. A scavenger method verified a significant increase in OH · concentration due to plasma treatment. Novel in-situ FTIR absorption spectra show the presence of O 3 , NO 2 , N 2 O, and other nitrogen species. Ozone dissolving in the H 2 O 2 solution can effectively generate OH · through a peroxone process. The addition of the reactive nitrogen species increases the disinfection efficiency of the hydroxyl radicals and other oxygen species. Hence, plasma activation of a low concentration hydrogen peroxide solution, using a hand-held flexible DBD device results in a dramatic improvement in disinfection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space shuttle guidance, navigation, and control design equations. Volume 3: Guidance

Space shuttle guidance, navigation, and control design equations are presented. The space-shuttle mission includes three relatively distinct guidance phases which are discussed; atmospheric boost, which is characterized by an adaptive guidance law; extra-atmospheric activities; and re-entry activities, where aerodynamic surfaces are the principal effectors. Guidance tasks include pre-maneuver targeting and powered flight guidance, where powered flight is defined to include the application of aerodynamic forces as well as thruster forces. A flow chart which follows guidance activities throughout the mission from the pre-launch phase through touchdown is presented. The main guidance programs and subroutines used in each phase of a typical rendezvous mission are listed. Detailed software requirements are also presented.

Source record↗

Ammonia Vent of the External Active Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS)

The External Active Thermal Control System (EATCS) provides cooling for all pressurized modules and the main Power Distribution Electronics (PDE) on the International Space Station (ISS). There are 2 EATCS loops (Loop A and Loop B) which includes 3 deployable radiators. Each deployable radiator contains 2 flow paths to provide heat rejection.Telemetry monitoring identified a coolant (liquid ammonia) leak in EATCS Loop B. Robotic External Leak Locator (RELL) scans found higher concentrations of vaporous ammonia near the EATCS Loop B Radiator #3 Flow Path #2. On May 3, 2017, the EATCS Loop B Radiator #3 Flow Path #2 was isolated and vented. As of the data to date, the ammonia leak has ceased. The purpose of this presentation is to discuss the analysis for venting the EATCS Loop B Radiator #3 Flow Path #2. Venting analysis is performed to determine the worst case time to empty the flow path and maximum thrusts imposed on the ISS. Flight controllers and engineers in the Mission Control Center (MCC) uses this data to develop operational procedures and perform the vent safely. It was predicted that the worst case time to empty the EATCS Loop B Radiator #3 Flow Path #2 was ~ 60 minutes. The predicted maximum thrusts were ~ 11 lbf (49 N) at the start of the vent and ~10 lbf (45 N) after the system reaches saturation.The vent was successfully performed and took ~ 20 minutes to empty the EATCS Loop B Radiator #3 Flow Path #2. Using telemetry from the day of the vent, analysis determined the time to empty the EATCS Loop B Radiator #3 Flow Path #2 would be ~13 minutes. The predictive analysis used worst case inputs and assumptions which bounded the actual results. Telemetry is not available to correlate actual thrust with the predicted maximum thrusts. However, by using Russian Thrusters for ISS attitude control, attitude control telemetry indicated the flight attitude was maintained.

Cowan, Darnell T.↗